Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.5 LAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹49.9 L+₹5.4 L (12.2%)Rejected-Finance NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹57.8 L+₹13.4 L (30.0%)Rejected-Finance SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASAPURA CV RAMAN NAGAR PO BANGALORE 560 093 | BANGALORE | BANGALORE | KARNATAKA | 560093 | L3 | Rejected-Finance NOT LOWEST |
Tender Value
₹57.5 L
EMD Value
₹1.1 L
Closing Date
5 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE ARMY BANGALORE
HQ CWE ARMY BANGALORE 101 Dickenson Road Bangalore 560042
Provision of Power Supply 180 KVA For NFS Composit Node Under GE (South) Bangalore
2020_MES_352395_1
85974 / E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bangalore
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE South
₹1.1 L
Yes
HQ CWE ARMY BANGALORE
14 Aug 2020
8 Jul 2020
7 Aug 2020
8 Jul 2020
5 Aug 2020
22 Jul 2020
8 Jul 2020 - 14 Jul 2020
15 Jul 2020
60 days
Amount
Excavation in trenches not exe. 1.5 M deep and not exec 1.5 M wide and getting out in hard / dense soil complete all as directed.
Excavation in trenches exceeding 1.5 M but n exc 3 M deep and not exceeding 1.5 M wide and getting out in hard / dense soil complete all as directed.
Excavating in post holes (or similar holes) each N exc 0.5 Cum, in hard / dence soil getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 Cm, complete all as diretced.
Surface excavation in hard / dence soil N. exc 300 mm deep (averaging 150 mm) and getting out complete all as directed.
Returning, filling in including spreading, levelling, watering, ramming, consolidating etc. of each layer N exc 250 mm thick complete all as directed.
Removing excavated meterial to a distance N exceeding 50 M and depositing where directed at a level N exceeding 1.5 M above the starting point complete all as directed.
Unreinforced precast cable covers class LV, Type-I, flat size 250 x 150 x 40 mm, factory made, laid in trenches for cable protection complete all as directed.
Reinforced precast concrete cable cover, class HV, type-I, flat, size 300 x 180 x 40 mm complete all as directed.
River sand including cleaning, spreading, levelling, punning for laying as in cussioning of cables complete all as directed. Note:- For purpose of payment punned thickness only will be measured.
Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
Hardcore of gauge N exc. 63 mm, deposited, spread and levelled in layers n exc. 150 mm thick, watered and rammed to a true surface complete all as directed.
PCC (1:4:8) type D-2 by using 40 mm graded stone aggregate as in mass concrete for sub base of poles / panels, repair to road surface etc. complete all as directed.
Plain Cement Concrete (1:2:4) type B-1 by using 20 mm graded stone aggregate as in coping of poles etc. including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as directed.
PCC 1:3:6 Type C2 by using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as directed.
PCC 1:3:6 type C1 using, 20 mm graded stone aggregate as in making good the road surfaces, hard standing etc complete all as directed.
Supply, Laying, connecting, commissioning and testing XLPE insulated, earthed, screened, PVC bedded, galvanised steel strip or wire armoured electrical power cable (heavy duty) with stranded aluminium conductor 11000 Volts grade of size 3 core 95 sqmm, ISI marked, conforming to IS 7098 Part-II, BESCOM approved, complete all as directed. Note:- (a) Excavation, earthwork and cable protection measured separately. (b) High voltage test shall be conducted at site with suitable voltage after laying of HT cables in presence of Engineer-in-Charge, JE & reading shall be recorded jointly and test report to be submitted in triplicate. The cost of the same deemed to be included in the unit rate.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as directed.
Supply only Chain link MS galvanisd fencing, 4 mm dia and 50 x 50 mm size complete all as directed.
Mild steel frame work conforming to Fe-410-0 or Fe 310-0 such as doors or gates of angle iron or other section including braces rails etc. complete drilled for fixing of steel sheeting or other covering doors etc. prepared for hanging or sliding with including either hooks and hinges or steel hanging door devices complete all as specified and as directed including painting with two coat of synthetic enameled paint over a coat of red oxide primer complete all as directed.
Applying two coats of synthetic enamel paint over a coat of red oxide primer including preperation of surface complete all as directed.
Boring holes under road pavement hard standing by trenchless technology using ultra sound technic and necessary machine with and including HDPE pipe of 150 mm dia suitable for 0.4 Mpa working pressure complete all as directed Note:- Quoted rates deems to be inclusive of transportation charges of drilling machine, connected accessories, HDPE pipe, Statutory charges for road cutting (getting necessary road cutting permission from BBMP / BESCOM / Traffic police authorities)
Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sq mm complete all as directed.
Cable jointing kit for 11 KV grade for indoor termination (earthed system), heat shrinkable type complete with all necessary jointing material and accessories suitable for 3 core XLPE armoured aluminimum conductor cable of size 95 sqmm complete all as directed.
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connecting with steel GI strip 32 x 6 mm as earthing lead by means of bolt nut check nuts and washers including PCC pit with 1:2:4 type B-1 using 20 mm graded stone aggregate and frame cover of angle iron 25 x 25 x 6 mm, MS sheet 3 mm thick and handle of 6 mm dia MS bar made to shape, GI medium grade 40 mm bore pipe for watering common salt chorcoal funnel wiremesh earth work in any type of soil returning filling in and removal of soil to a distance n.exc 50 mtr including earth test point and making connections testing on completion all as per electric plate No 3 of SSR Part-I, complete all as directed.
GI strip 32 x 6 mm for earth lead connection fixed on wall / pole with suitable clamps, screws etc., complete all as directed.
Supply, Installation, testing and commissioning of outdoor, Non walk in type 200 KVA Compact Sub Station, Type tested 11KV/433 V transformer and HT/LT Panels etc in one outer enclosure (with base frame) incl PCC foundation (as per Mfr recommendation) complete all as per following specfications :-
HT SWITCHGEAR:- 11 KV 630 A 21 KA for 3 sec SF6 insulated Extensible compact switchgear (Type DV) consisting of one No. Direct Module and one No. Fixed manual Vacuum Circuit Breakers in SF6 insuated Stainless steel enclosure with series trip, self powered microprocessor based numerical over current and Earth Fault (IDMT + Inst.) relay protection 01 No., Protection CT, 40 / 1 Amps, 2.5 VA, 5 P10 (For Protection) - 03 Nos, Manometer - 01 No. and Interconnection between HT switchgear and transformer shall be using 1C x 3 x 95 Sq.mm, Aluminium unarmoured XLPE Cable.
TRANSFORMER:- 200 KVA capacity with copper windings 11 / 0.433 KV DYN 11 ONAN hermetically sealed transformer with corrugated tank, top bushing on HV & LV side, temperature rise 40-45 degree centigrade(oil/binding) of circuit tapping +5% to -5% @ 2.5% per step. Total losses at 50% load 670 Watts and total losses at 100% load 2100 watts. Technical parameters as per IS : 1180-2014 EEL-3, impedence 4.5% (subjected to IS tol) (Make :- as per OEM) -01 No, Oil temperature indicator with Alarm and Trip Contact - 01 No, Winding temperature Indicator with Alarm and Trip Contact - 01 No. Door interlock with breaker 01 No.
LVS PANEL:- 400 Amp Aluminium Bus bar (for Phase 100% and Neutral 50%) Current density of Al shall be 1 A / sq.mm, LT panel shall be made up of 2 mm thick CRCA sheet. INCOMER:- (a) 400 Amp 433 V 4P / TPN 35 KA Manual Fixed (MF) type Moulded Case Circuit Breaker (MCCB) with Thermal Magnetic Based over current, short circuit and earth fault Release (LSIG). (Make:- as per OEM Recommendation) - 01 No. (b) LED Type Indicating Lamps - R,Y,B Phase and ON - OFF, TRIP - 01 Set (c) Multi function meter - 01 Set (d) LT Current Transformer - 400 / 5 Amps, 5 VA, Class - 1.0 (Make:- as per OEM Recommendation) - 04 Nos.
OUTGOING:- (a) 250 Amps 433 V 4P 35 KA Manual Fixed (MF) type Moulded Case Circuit Breaker (MCCB) with Thermal Magnetic Based over current, short circuit Release (LS) - 02 Nos (b) 160 Amps 433 V 4P 25 KA Manual Fixed (MF) type Moulded Case Circuit Breaker (MCCB) with Thermal Magnetic Based over current, short circuit Release (LS) - 02 Nos (c) 32 Amps 433 V 4P 16 KA Manual Fixed (MF) type Moulded Case Circuit Breaker (MCCB) with Thermal Magnetic Based over current, short circuit Release (LS) - 02 Nos APFC PANEL 70 KVAR Automatic power factor correction panel with Aluminium Busbar in 6 steps (25 KVAR x 2 + 5 KVAR x 4) consisting of following:- (a) 100 A 433V 3P 50Hz 35KA Manually Fixed Manual Type Moulded Case Circuit Breaker (MCCB) with Thermal Magnetic based release for overcurrent and Magnetic short circuit Protection - 01 No. (Make:- as per OEM) +B44
(b) APFC RVC Relay for 6 steps - 01 No. (c) 25 KVAR metallised polypropelen capacitor bank - 02 Nos (d) Capacitor duty contactor for switching on and switching off 25 KVAR bank - 02 Nos (e) 36A 3P Miniature circuit breaker (MCB) for 25 KVAR Capacitor bank - 02 Nos (f) 5 KVAR metallised polypropelen capacitor bank - 04 Nos (g) Capacitor duty contactor for switching on and switching off 5 KVAR bank - 04 Nos (h) 10 A 3P Miniature circuit breaker (MCB) for 5 KVAR Capacitor bank - 04 Nos
OUTDOOR ENCLOSURE:- Outdoor type enclosure having construction of Galvanised Sheet Steel of thickness 3 mm for Load bearing member and 1.5 mm for Non Load bearing member. The Enclosure shall have IP 54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure exterior shall be Powder coated (Colour Light Gray & D.A.Gray ). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV and LV compartment. For entire enclosure minimum spacing between equipments and compartment wall as per IEC / IS standards to be maintained and all equipments / panel should have easy access and minimum specified clearance of space for maintenance and repairs / replacement complete all as directed:- 1 Set.
INTERCONNECTION AND EARTHING:- Interconnection Between HT switchgear & Transformer using 1C x 3 x 95 Sq.mm Aluminium unarmorured XLPE Cable. & Interconnection between Transformer & LT switchgear using Aluminium Busbar. Internal earthing connections by using 50 x 6 GI strips. Transformer Neutral earthing with 25 x 6 mm Copper strips.and control wiring with multistrand 1.5 Sqmm copper conductor PVC insulated and sheathed cables with color coding complete all as directed and as approved - 1 set.
Notes:- (a) Contractor shall obtain prior approval of make (OEM) and drawing from the GE before commencement of work. (b) Manufacturer's test certificate shall be submitted. (c) The quoted rate shall be inclusive of construction of Platform of suitable size as per OEM specification for installing the Package Sub Station, Erection, Commissiong. Make of OEM:- ABB / Schneider / Crompton
Supply, fixing, commissioning and testing 11 KV, Air Insulated HT Metering cubicle of different CT ratio, both side cable entry type without load break switch (LBS), DLMS features with resin cast 11 KV CT ratio / 1A, 2.5 VA, class 0.2, STC 20 KA / 1sec, ILV : 12/28/75 KVP and PT or ration 11 KV / Root 3 and 110 / Root 3 Burden 25 VA complete with transparent cover TTB, 30 x 8 mm copper busbars and two Nos of meters for 3 phase 4 wire metering, panel fabricated out of 3 mm MS sheet duly epoxy powder coated including PCC foundation for mounting the metering cubicle all as per latest BESCOM specifications including GSM Modem Model No. ARG 45 of AMI Tech (India) Pvt. Ltd. / BESCOM Approved and as directed. Make of CT/ PT : Schnieder / ABB / Siemens / BESCOM Approved Make of Meter : C&S / Secure / L&T / BESCOM Approved
Supplying, fixing, testing and commissioning of 3 way out door type RMU (Ring Main Unit) with copper bus bar, 350 MVA, 630 A as per IEC - 62271 / IS-3427 with DAS specification of 2 OD + 1 VL Right side extensible (compatible to BESCOM configuration including DAS) consisting of 2 Nos load break switch of 630 A and 01 No. 400 A, VCB and metering panel with protection and metering CTs, complete with PCC foundation for mounting including lettering the breaker with enamel paint and writing single line daigram for each panel and as per followings specifications complete all as directed.
(i) Type - Out door type RMU (ii) Operating Voltage - 11 KV (iii) Rated Frequency - 50 HZ (iv) Rated start time current - 21 KA (v) Operation - Motorized (vi) VCB - 400 Amp (Fixed type) (vii) Load break system - 630 A (Fixed type) (viii) Protection - Self powered O/C and E/F Relay protection with suitable protector CTs for distribution transformer. (ix) Bus Bar - 630 Amps (x) Class of protection - (a) IP 67 for SF6 Gas Tank (SS) (b) IP 2X for front cover (c) IP 54 for outdoor enclosure Make:- Schneider / ABB / Siemens/BESCOM approved
Supplying, laying, testing and commissioning of cable, XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sq mm 3.5 core complete all as directed
Supplying, laying, testing and commissioning of cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sq mm, 4 core Note for Item No. 29 & 30:- Excavation, earth work, cable covers and cable protection will be measured separately.
Steel tubular Swaged poles, type 410SP-31 (9.0 meter long) Swan Neck Type complete with CI base plate, finial and single swan neck including two coats of painting with black bituminous through out internally / externally up to the planting depth and remaining portion of the exterior to be painted with two coats of synthetic enamel aluminum paint over a coat of red oxide primer including three runs of PVC insulated 1100 V multi stranded copper wire of size 1.5 Sqmm from the junction box to the fitting complete all as directed. Note:- Excavation / earth work and PCC for foundation and coping will be measured and paid seperately. Make:- Bombay Tubes / India Electric / Kalinga Tubes
Time switch distribution board with time switch analog type ( with battery backup) 3 pole module, current capacity 16 A including suitable contactor and MCB duly wired and fitted in steel enclosure factory fabricated powder coated complete all as directed Make: Indo Asian Cat NO : TL016ABO / Equivalent in Haveels / Crompton.
LED street light with not less than 10800 lumen and CCT 5700K (+/-) 300 K made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 / IK07 protection complete all as directed. Make:- Bajaj Cat No BRTFG 90W LED CR / Equivalent in Cropmton / Havells
GI tube "light grade" 80 mm dia for cable protection in trenches / walls, ceiling, floors etc. complete all as directed.
GI tube "light grade" 50 mm dia for cable protection in trenches / walls, ceiling, floors etc complete all as directed.
Cable route indicator made out of round CI disc embosed LT / HT cable, of size 160 mm dia, 6 mm thick duly revited with angle of size 50 x 50 x 4 mm and 600 mm long incuding PCC 1:2:4 type B2 using 20 mm graded stone aggreate, 150 x 150 x 150 mm for grouting the same all as directed.
Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters figures and convensional skull and bone in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT 250 x 200 mm size complete all as directed.
Shiva Shakthi Electrical Enterprises
B5BUILDING SOLUTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .