Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC | L1 | Accepted-AOC accept | |
| 2 | L2₹35.6 L+₹13,726 (0.39%)Rejected-AOC | L2 | Rejected-AOC reject | |
| 3 | L3₹36.1 L+₹65,280 (1.84%)Rejected-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-AOC reject | |
| 4 | L4₹36.5 L+₹1.1 L (2.97%)Rejected-AOC PLOT NO 8 PREMA APARTMENT VEDANTNAGAR CHHATRAPATI SAMBHAJINAGAR 431 007 M S | CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | 431007 | L4 | Rejected-AOC reject | |
| 5 | L5₹41.4 L+₹5.9 L (16.6%)Rejected-AOC | L5 | Rejected-AOC reject |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
12 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Provision of certain sanctioned works (01) of E/M nature under GE (N) Ahmednagar
2022_MES_552672_1
8677 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Cat b(i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹76,000
Yes
17 Oct 2022
17 Sept 2022
14 Oct 2022
17 Sept 2022
12 Oct 2022
30 Sept 2022
Amount
Supply,installation,testing and commissioining factory made LT feeder pillar panel CPRI approved, size of panel as per CPRI Specification,double door floor mounted outdoor type,as per IP-65 grade,made out of CRCA sheet 3.15 mm thick of outer body of suitable size with aluminium bus bar 600 Amps,4 strip,(3 phase & Neutral) complete drilled,insulated with colour coaded insulation tape,mounted on insulators etc with RYB indicater,internal wiring with suitable size of copper wire,panel should be dust proof,vermin proof,powder coated,locking should be screw type,mechanical type,inter locking,should have danger notice for 415 volt,AC,mounted on 50 x50 x6 mm angle iron frame having minimum 2 feet ground clearanceduly embedded in and including PCC block(1:2:4) type B1 using graded stone aggregates as in foundation for fixing of panel complete including ternination of all incoming and outgoing cables with suitable size thimbles/lugs and glands Nuts & Bolts (HCOM) etc complete all as specifid and directed by Engineer-in-Charge.
Incoming : - (i) MCCB 250 Amp Thermal & Magnetic adjustable type with , 4 Pole,36KA - 01 No. (Ics=100% Icu) (ii) KWH meter CT operated as per suitable capacity of LT Panel (iii) Amp meter square flush pattern 0 to 400 Amps digital type -01 No. (iv) Indicating lamp LED type one set in incoming phases. (v) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs (vii) MCCB shall be provided with suitable spreader of aluminium conductor for fixing of incoming cable (viii) KWH meter CT operated as per suitable capacity of LT Panel Outgoing ways :- (i) MCCB 160 Amps Thermal and magnetic adjustable type ,4 pole,25 KA-03 Nos(Ics=100% Icu) (i) MCCB 100 Amps Thermal and magnetic adjustable type ,4 pole,16 KA-02 Nos(Ics=100% Icu)
Notes:- 1. The Panel Shall be approved by CPRI. 2. The rates Quoted shall include for earth work,Plinth protection around the panel apprx 75cm and excavation for angle iron frame for foundation of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 using graded stone aggregate filling in foundation. The ground clearance of panel board shall be 0.40 M from GL to the bottom of panel board. 3. ALL MCCBs should be handle operated and outgoing MCCBs are connected through HRC Fuse 4.Make of MCCBs - L&T,Legrand,ABB,Simens,Havells 5.All incoming power MCCBs and outgoing MCCBs connected through busbar and control wiring connected through copper cable
Supply,installation,testing and commissioining factory made LT feeder pillar box ( bus bar chamber) , size of bus bar 600 x 600 x350 mm,double door floor mounted outdoor type,as per IP-65 grade,made out of CRCA sheet 3 mm thick of outer body of suitable size with aluminium bus bar 500 Amps,4 strip,(3 phase & Neutral) complete drilled,insulated with colour coaded insulation tape,mounted on insulators etc with RYB indicater,panel should be dust proof,vermin proof,powder coated,locking should be screw type,mechanical type,inter locking,should have danger notice for 415 volt,AC,mounted on 50 x50 x6 mm angle iron frame having minimum 2 feet ground clearanceduly embedded in and including PCC block(1:2:4) type B1 using graded stone aggregate foundation for fixing of panel complete including ternination of all incoming and outgoing cables with suitable size thimbles/lugs and glands Nuts & Bolts etc complete all as specifid and directed by Engineer-in-Charge. (a) Aluminium Bus-bar 4 Strip, 450mm long, 500 Amp, 415 Volt - 01 Set (b) Incomong MCCB 4 Pole 160 Amps()Ics=100% Icu) - 01 Nos for control (B) Outgoing ways 4 nos of LT cables provision of size 50 to 120 Sq mm
Material and labour for street light control board / box of size 0.50 X 0.50 X 0.20 m made out of 1.60 mm thick MS sheet fixed / mounted on pole by means of 2 Nos of FT clamps of size 25 X 3 mm comprising the following enclousers and connecting with suitable size of copper cable all as directed:- a) MCB, TPN, 63 Amps, - 01 No b) Timer switch (01 Nos), eletronic, ET 100 operating on 110 / 240 / 415 Volts, 50 Hz MAKE: CAT No SE92006 OF L&T OR equivalent in makes mentioned in list of makes in Appendix `C' c) Contactor ML 2, 63 Amps,415 Volt - 02 No MAKE: CAT No SS90701 OF L&T OR equivalent in makes mentioned in list of makes in Appendix `C' d) All outgoing MCbs,TPN,contractor contected through HRC fuse of suitable capacity etc complete all as specifid and directed by Engineer-in-Charge.
M&L Street Light Fitting Bracket made out from GI Pipe 40 mm Bore (dia), Light Grade, not exc. 1.20 Metre long, bend to required shape and fixing to Poles, etc. with and including Mild Steel Flat Iron Clamps 40x5mm of suitable Length, 2 No. Nuts, Bolts, Washers, etc. including Painting with One coat of Red Oxide Zinc Chrome Primer and Two coats of Aluminium Paint to all Mild Steel Works etc complete all as specifid and directed by Engineer-in-Charge.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing of any description, etc complete all as specifid and directed by Engineer-in-Charge.
Dismantling carefully the existing LT overhead line ACSR conductor with cross arm of any size from its position by necessary disconnecting of conductor and removing etc complete all as specifid and directed by Engineer-in-Charge.
S&F Shock Proof, Rust Proof, Fire Retradrant, Non-transparent Kiosks Pole Box of size 200x175x100mm made of Engineering Plastic on Piece moulding for Outdoor type, Heavy duty with 4 No. insulated Alunminium Bus-bar of 60 Amp capacity, mounted on Unbreakable Insulators MCB SP, 10 Amp, complete with Aluminium Lugs of suitable size upto 50 Sqmm including 2 No. Flat Iron 40x3mm Clamps with suitable size Mild Steel Bolts, Nuts & Washers, etc. and duly Painted on Both Sides with Two Coats of Synthetic Enemel Paint over a Coat of Red Oxide Zinc Chrome Primer Pole Box of any description from any Height, etc complete all as specifid and directed by Engineer-in-Charge.
Dismantling of unserviceable existing cross arms made from channels, angles and unserviceable FI clamps, nuts, bolts etc from OH line and removing etc complete all as specifid and directed by Engineer-in-Charge.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:-
(a) 10 sqmm, 4 Core
(b) 16 sqmm, 4 core
(c) 35 Sqmm, 31/2 core
(d) 50 Sqmm, 31/2 core
(e) 70 Sqmm, 31/2 core
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor 95 sqmm 3.5 core after removing old unserviceable cable etc complete all as specifid and directed by Engineer-in-Charge.
Excavating in trenches n exc 1.5 mtr wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out on soft/ lose soil etc complete all as specifid and directed by Engineer-in-Charge.
Returning, filling in, including spreading , levelling , watering and well ramming in layers not exc 25cm of any soil etc complete all as specifid and directed by Engineer-in-Charge.
Removing excavated materials(soils) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point etc complete all as specifid and directed by Engineer-in-Charge.
M & L for PCC(1:2:4) type C-2 using 40mm grade stone aggregates for coping and similar work etc complete all as specifid and directed by Engineer-in-Charge.
M&L for laying GI pipe light grade of size 40 mm dia to pass LT cables acoss road/drain/culvert/along wall etc complete all as specifid and directed by Engineer-in-Charge.
All as per Item No 22 (here-in-before) but 80 mm dia tubes
Demolation of u/s cement concrete in coppings etc complete all as specifid and directed by Engineer-in-Charge.
Supply & laying of Telerex DWC(Double wall corrugated) HDPE pipe ISI marked ( Pipe colour orange) of outer dia 63 mm and Inner dia 50 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable icluding coupler and bends etc complete all as specifid and directed by Engineer-in-Charge.
Supply & laying of Telerex DWC(Double wall corrugated) HDPE pipe ISI marked ( Pipe colour orange) of outer dia 110 mm and Inner dia 95 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable icluding coupler and bends complete all as specified and directed.
Material and labour for spray painting the LT Steel tubular pole,9 mtr long with applying one coat of red oxide and two coats of synthetic enamel paint including prepartion of surfaces,Scraping the old paint and writing pole No in Black letter under yellow circle etc complete all as specifid and directed by Engineer-in-Charge.
M&L for road cutting upto 300mm deep and 200mm wide for crossing GI pipe line through road including making good the disturbed surface by filling mass concrete complete all as specified and directed.Note : Rate of mass concrete included in quated rate etc complete all as specifid and directed by Engineer-in-Charge.
S&F LT cable route indicator of Cast iron not less than 100 mm dia fixed through welding angle iron supoort of size 25 mm x 25mmx5mm thick ,600mm long including two coats of synthetic enamel paint (yellow in colour) over a coat of red oxide primer planted in a PCC foundation (PCC 1:3:6) type C2 using graded stone aggregate The whole assembly of PCC iron will be planted in ground upto 30 cm complete all as specified and directed.Note : Rate of PCC foundation included in quated rate etc complete all as specifid and directed by Engineer-in-Charge.
Dismaintling of unserviceable Street light fitting of any capacity and S&F new street light fitting (LED) of capacity 60 W, 6000-6500 Lumen- 6000 Lm, 10 KV in build surg protection IP-66, die cast aluminium housing and 4 Sqmm service wire for necessary connection etc complete all as specified and directed by Engineer-in-Charge. Make : Havells cat part no ; ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent makes mentioned in list of makes in Appendix `C'
Supply & fixing FRLS PVC insulated cables aluminium conductor, standard 4 Sqmm 2 Core, etc complete all as specifid and directed by Engineer-in-Charge.
Supply and fixing sintex box of size 200x175x100mm with suitable size of clamp for street ligt control box including 10 Amps SP, MCB etc complete all as specified and directed by Engineer-in-Charge.
M&L Street Light Fitting Bracket made out from GI Pipe 50 mm Bore (dia), Light Grade, not exc. 1.20 Metre long, bend to required shape and fixing to Poles, etc. with and including Mild Steel Flat Iron Clamps 40x5mm of suitable Length, 2 No. Nuts, Bolts, Washers, etc. including Painting with One coat of Red Oxide Zinc Chrome Primer and Two coats of Aluminium Paint to all Mild Steel Works etc complete all as specifid and directed by Engineer-in-Charge.
Taking down carefully copper/aluminum point wiring (light/fan/bell/socket, power point etc) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors etc complete all as specified and directed Engineer-in-Charge
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories PVC boxes (upto 12 module suitble for Britez series of Legrand including white plates with frame upto 12 module of make suitable for Mylinc Series ) for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed. Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, ceiling lights, bulkhead lights, bldg security light etc
One light point controlled by switch 5 Amp single pole one way
One fan point controlled by switch 5 Amp single pole one way
One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch
One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board
All as per Item No 35 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase , Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board
M&L for Modular point wiring complete concealed type with two runs of 1.5 Sqmm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH stranded cable drawn through and including PVC rigid conduit not less than 20 mm dia with its accessories and provn of PVC terminal switch box powder coated with and including 3mm thick white bakelite plastic laminated top sheet cover and fixed with brass screws, cup washer for fixing switches / socket / regulators etc with and including 1.5 Sqmm, Single Core, multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH stranded cable as earth continuity conductor to common earth & connecting to earth dolly for the following etc complete all as specified and directed by Engineer-in-Charge. Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black). 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, ceiling lights, bulkhead lights, bldg security light etc
One light point controlled by switch 5 Amp single pole one way
One fan point controlled by switch 5 Amp single pole one way
One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch
One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board
One bell point controlled by switch 5 Amp single pole one way
All as per Item No 41 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase , Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board
S&F Modular Switch, 6 Amp, one way, one Module. etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Switch, 16 Amp, on way, one Module. etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Socket Outlet 6 Amp, 2/3 pin, combined two module etc complete all as specified and directed by Engineer-in-Charge.
S&F Modular Socket Outlet 6 Amp / 16 Amp - 2/3 pin combined two module etc complete all as specified and directed by Engineer-in-Charge
S&F Modular bell Switch, 6 Amp, one way, one Module. etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified and directed by Engineer-in-Charge
M&L ceiling rose 3 terminal / PVC / polycarbonate, isolated body etc complete all as specified and directed by Engineer-in-Charge
S & F in replacement double door Sheet metal enclosures factory made Vertical DBs Concealed in wall 4 way TPN, 415 volts ,protection class IP-42, including 63 Amps MCCBs Input and suitable for fixing of outgoing MCBs, etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet etc complete all as specified and directed by Engineer-in-Charge
S & F in replacement double door Sheet metal enclosures factory made DBs SPN, 8 way ,240 volts ,protection class IP-42,Concealed in wall suitable for fixing of MCBs,, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet etc complete all as specified and directed by Engineer-in-Charge
S & F in replacement double door Sheet metal enclosures factory made DBs SPN, 4 way ,240 volts ,protection class IP-42, suitable for fixing of MCBs,, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCB , SP, AC, 240 Volts of 06 to 40 Amp capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCBs, TPN, AC, 415 volts of 63 Amps capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCBs, SPN, AC, 240 volts of 40 Amps capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply and fix Industrial type ultra slim square profile LED lighting fixture, environmental friendly, energy efficient ready to use pack Industrial type LED Tube light fitiing 20 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Engineer-in-Charge
S&F Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitiing 10 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with 2 core seathed copper conductor cable of size 0.5 Sqmm with etc complete all as specified and directed by Engineer-in-Charge
Supply & fix in replacement energy saving and environmental friendly long life LED street light 25 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK07 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230V , 50 HZ etc complete all as specified and directed by Engineer-in-Charge
S&F sub main wiring with two single core PVC insulated,unsheathed, FRLS stranded copper conductor cable 4 Sqmm with 4 Sqmm PVC insulated, unsheathed, FRLSH stranded copper conductor cable as earth wire drawn through and including PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. Two run of 4 Sqmm cable i.e for one run for phase, one run for neutral with one run of 4 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit
S&F sub main wiring with two single core PVC insulated,unsheathed, FRLSH stranded copper conductor cable 6 Sqmm with 6 Sqmm PVC insulated, unsheathed, FRLSH stranded copper conductor cable as earth wire drawn through and including PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge (Make of Cable : Finolex/RR Cable/Havells & Make for PVC Casing & Caping : AKG / PRESTOPLAST /PRECISION): - Note : 1. Porper colour coding must be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. Two run of 6 sq.mm cable i.e for one run for phase, one run for neutral with one run of 6 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit
Supply &lay HDPE pipe 40 mm bore light weight with 0.95 gm/cm2 IS: 4984(1995) PN 2.5 for laying of LT cable complete with all accessores etc complete all as specified and directed by Engineer-in-Charge
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, including Flexible pipe 2 set , fastner fixed in wall etc complete all as specified and directed by Engineer-in-Charge
Supply and fix of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches/walls complete all as specified with all fittings and joints etc complete all as specified and directed by Engineer-in-Charge
Supply and fix Bib taps, cast copper alloy with screwed for iron pipe of for brass ferrule and fixed of size 15 mm bore etc complete all as specified and directed by Engineer-in-Charge
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300msweep with, blades, and frame and louvers with nut bolts fixed in wall including Cemnent work for fixing Exhaust fan etc complete all as specified and directed by Engineer-in-Charge
Supply & fix replacemnt industrial type switch socket for Geyser/heater with 20 Amp MCB etc complete all as specified and directed by Engineer-in-Charge
An amount of Rs 34,643.00 shall be deducted from BOQ on account of schedule of credit
Mahindra Electric Stores
metro electrical services
ASHWAMEDH ENGINEERS
Ms. S.K. ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .