Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹5.1 LAccepted-AOC | L-1 | Accepted-AOC Tender accepted due to the lowest tenderer | |
| 2 | L-2₹5.9 L+₹55,998 (10.6%)Rejected-Finance 88 GIRRAJ NAGAR KALWAD ROAD JOTHWARA JAIPUR 302012 JAIPUR CITY NORTH RAJASTHAN 302012 | JAIPUR | RAJASTHAN | 302012 | L-2 | Rejected-Finance Not being L1 | |
| 3 | L-3₹5.9 L+₹61,788 (11.7%)Rejected-Finance | L-3 | Rejected-Finance Not being L1 | |
| 4 | L-4₹6.3 L+₹96,303 (18.2%)Rejected-Finance | L-4 | Rejected-Finance Not being L1 | |
| 5 | L-5₹9.0 L+₹3.7 L (70.1%)Rejected-Finance C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L-5 | Rejected-Finance Not being L1 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
27 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Niwaru
AGE (I) Niwaru
AGE (I)/N-39 OF 2022-23 REPAIR AND MAINT TO SECURITY LIGHTS AT MUNDOTA AND NIWARU MIL STN UNDER AGE I NIWARU
2023_MES_578398_1
AGE(I)/N-39 of 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) Niwaru
CLASS
6 documents required · 6 mandatory
₹500
Yes
AGE (I) Niwaru
₹20,000
Yes
6 Mar 2023
1 Feb 2023
1 Mar 2023
1 Feb 2023
27 Feb 2023
14 Feb 2023
Amount
Disconnecting old existing non functional street light, flood light & Post top lantern/gardenlight fitting of any size/type complete from poles/High Mast/Bldgs as directed by engineer in charge in AOR of AGE E/M Niwaru.
Fixing only LED street light/Flood light of any capacity/make to extg poles/bldgs/High mast light and connecting with existing cable, including nuts, bolts and washer etc complete all as specified & as directed. Note:- LED street light/flood light will be issued under Sch ‘B’ free for fixing only.
Supply and fix 1.5 Sqmm 3 core cable, PVC insulated and PVC round sheathed, copper conductor (flexible) industrial cable, 1100 volt, confirming to IS :694 including replacement of old unsv cable. Note- (i) Cable is reqd to be connected from street light to junction box with proper lugs.
Supply and fixing street light fitting LED type of capacity 45 Watt with PDC aluminium body and toughened glass visor fittted in frame, secondary optical lens for superior light distribution, Efficacy>= 110 Lm/W, 5700K, driver efficiency>= 85%,Power factor>=0.95 IP66 protected to be fixed in existing bracket at extg poles/bldgs all as specified & as directed. Make- Polyca cat part No-PCGLS T1 45 N or equivalent in Surya, Crompton, Havells, C&S
S&F drivers in repairs for LED street light 45 watt to 90 watt complete all as directed by EIC.
S&F drivers in repairs for LED flood light 50 watt to 150 watt complete all as directed by EIC.
Note for Item No 1 to 6 :- (i) T&P required for above work such as ladder, Crane vehicle, menpower etc, are inclusive in the item rate. (ii) Rate of necessary arrangement for fixing LED light on existing bracket like reducer or extention of pipe by suitable size of GI pipe as per dia of LED light by welding etc are inclusive in the item rate.
S& F in replacement cable junction box of size 350x250x150 for outdoor installation IP-65 protected made of poly carbonate with necessary clamps (2 Nos) for mounting on poles, comprising with copper bus bar for 3 phases and neutral of required amps capacity for cable size 16/35 sqmm 4 core, phase and neutral fixed on porcelain insulator and MCB, SP 0.5 to 6 amps, 10 KA - 01 Nos complete including taking down old unsv junction box complete. Make- Hensel cat part K8350 or equivalent in Sintex/ legrand/indokop
S& F in replacement digital time switch 110- 240 V AC 1 C/O Base /DIN 25 ON/OFF all as specified and directed by engineer in charge.
S& F in replacement contactor 22 Amp for street light timer, three phase 415 V AC 50 Hz (contactor will be as per sample) all as specified and directed by engineer in charge.
S& F in replacement contactor 40 Amp for street light timer, three phase 415 V AC 50 Hz (contactor will be as per sample) all as specified and directed by engineer in charge.
Supply and fix in repairs MCB’s single pole with neutral, 6 Amps,10KA, 250 volts with ‘C’ curve, fixed in existing PVC box including connecting complete.
Taking out & rewinding the existing unserviceable burnt induction motor 1.5 HP, 3phase, 50 cycles by disconnecting electrically and mechanically and transporting to the locally contractors workshop. Dismantling the motor and removing the old burnt copper winding & demoisturise, cleaning, rewinding the coils with same gauge supper enamelled copper wire, with suitable F class paper insulation, varnishing, and reassembling by replacing bearings,Remetalling of armature shaft and turning on lathe to give proper size for bearing fittings,Replacement of terminal plate and reinstalling at the installation and testing, commissioning etc complete. Note - Before rewinding the existing motor, contractor must show the burnt motor/winding to the EIC. Old unserviceable copper retrieved will be property of contractor.
Supply and Laying Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armoured, cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade and connecting and testing in trenches, under floors/ roads or on walls in repair and incl taking down of following sizes :- (Note 1.: Earth work, excavation shall be measured & paid separately under respective item of Schedule). make- Havells/Gloster/Polycab
(a) 10 Sqmm, 2 core cable
(b) 16 Sqmm, 4 core cable
Laying only in trenches, in trenches, under floors/ roads or on walls/poles in repair and incl taking down of cable XLPE insulated armoured cables with stranded aluminium conductor, 1100 volts grade and connecting and testing of following sizes :- Note:- (i) Earth work, excavation shall be measured & paid separately under respective item of Schedule). (ii) Cables will be issued under Sch ‘B’ free for fixing only.
16 Sqmm, 2 core cable
35 Sqmm, 3.5 core cable
M&L for excavating in trenches n. exc 1.5m wide for laying of cables not exceeding 10 Sqm area on plan and not exceeding 1.5 meters in depth and getting out in soft/loose soil.
M&L for removing excavated material n.exc 50m and deposting where directed at a level n.exc 1.5 m above the starting point.
M&L for returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm.
M&L for sand cushioning to under ground cable screened and washed sand and punning down in trench all as directed (punning thickness will be measured for payment).
M&L for brick with sub class 'B' laid flat and dry aboutting each other with gap between adjacent bricks not exc. 10mm, over UG cable for protection.
M&L for GI tubing, light grade including all fittings for protection of under ground cable on poles/ walls/ under road crossing etc. complete all as diected.
(a) 40mm dia
(b) 50mm dia
Shree Karni Electrovision
M/S TRADE LINKERS
S.R.Enterprises
Ms Kamal Kant Agarwal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .