| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 LAccepted-AOC AT GORANGO COLONY PO PHUSRO DISTT BOKARO JHARKHAND 829144 | PHUSRO | BOKARO | JHARKHAND | 829144 | ₹1.8 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹2.8 LRejected-Finance AT CHALKARI BASTI PO JARIDIH BAZAR DISTT BOKARO JHARKHAND 829114 | BOKARO | BOKARO | JHARKHAND | 829114 | ₹2.8 L | L2 | Rejected-Finance As per Approved TCR |
| 3 | L3₹3.6 LRejected-Finance | ₹3.6 L | L3 | Rejected-Finance As per Approved TCR |
| 4 | L4₹3.6 LRejected-Finance AT SELECTED DHORI COLLIERY POST PHUSRO BAZAR DIST BOKARO JHARKHAND 829144 | PHUSRO BAZAR | BOKARO | JHARKHAND | 829144 | ₹3.6 L | L4 | Rejected-Finance As per Approved TCR |
| 5 | L5₹3.6 LRejected-Finance | ₹3.6 L | L5 | Rejected-Finance As per Approved TCR |
Tender Value
₹3.3 L
EMD Value
₹4,200
Closing Date
27 Dec 2025, 4:00 pmClosed
P E (Civil) G M Unit, BnK Area, Kargali
P E (Civil) G M Unit, BnK Area, Kargali, P.O.-BERMO, DIST.-BOKARO (JHARKHAND)-829104
Providing shade in front of Community Centre at Pichhari under GM Unit BnK Area
2025_CCL_349568_1
PE(C)/GMU/E -Tender/25-26/15, dt. - 17.12.2025
Open Tender
Civil Works - Others
30 days
GM Unit
As per NIT
3 documents required · 3 mandatory
₹4,200
24 Apr 2026
17 Dec 2025
29 Dec 2025
18 Dec 2025
27 Dec 2025
18 Dec 2025
18 Dec 2025 - 22 Dec 2025
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling / self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter .(600 mm over all girth)
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Shoe (Plain) 110 mm Shoe
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend
Total impact of GST for the purpose of CTC
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_362313.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.23 MB
BOQ_362313.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid