Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance NO 86 V O C STREET MALAIKOVIL THIRUVERUMBUR TRICHY 620 013 | TRICHY | TRICHY | TAMIL NADU | 620013 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹4,900
Closing Date
8 Aug 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Director, NIOT
NIOT CAMPUS, CHENNAI - 600100
Building renovation work at CEE Store room in NIOT campus
2024_NIOT_816319_1
NIOT/SnP/EnM/29811/2024-25
Open Limited
Civil Works
Works
NIOT CAMPUS, CHENNAI
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹4,900
8 Aug 2024
12 Jul 2024
8 Aug 2024
12 Jul 2024
8 Aug 2024
12 Jul 2024
12 Jul 2024 - 7 Aug 2024
Amount
Removing white or colour wash by scrapping by wall into sand papering/machine scrapping and preparing the surface smooth including necessary repairs to scratches etc. Complete
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. two or more coats
Wall painting with Interior wall primer paint of approved brand and manufacture to give an shade: one or more coats. Note: apcolite advanced heavy duty emulsion appropriate priming coat or equivalent
Wall painting with External wall primer paint of approved brand and manufacture to give an shade: one or more coats. Note: apcolite advanced heavy duty emulsion appropriate priming coat or equivalent
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on old work Note: apcolite advanced heavy duty emulsion or equivalent
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on old work
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand)
TERRACE WATER PROOFING (ROOFSEAL ULTRA) Prepare the surface thoroughly by cleaning, washing and removing dust, dirt, oil grease and loose particles. Surface cracks must be filled with Crack-X Powder or polymer-modified mortar in case of wider cracks and joint between the existing blocks. Apply one coat of Dr. FIXIT PRIMESEAL (dilute with water in the ration 2:1). Allow it to dry for 2-3 hours. Laying one coat of Fiber Gloss mesh. Apply the first coat of High Solid, UV resistant, PU Membrane waterproof coating of Dr. Fixit ROOFSEAL ULTRA and allow it to dry before taking up the second and Third coats. The sequence of colors viz. White, top coat colour. This would ensure correct consumption of material that will deliver a total DFT of 1 mm. Drying time between coats will be 6 - 8 hours. Ensure that the primer and the 3 coats of Dr. Fixit ROOFSEAL ULTRA totally achieve a minimum thickness of 1 mm DFT. Allow the system to air cure for 7 days. Note:Warranty of 5 years should be provided by contracter for water proofing work as prescribed performa by Niot
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
TOTAL WITHOUT GST
GST at 18%
SEENU HARI ENTERPRISES
Mahilnivasini Constructions and Transport
JPS CONSTRUCTIONS
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .