Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.7 LAccepted-AOC 8 51 PLOT NO 6 LIC COLONY SUJATA NAGAR PENDURTHY MANDAL VISAKHAPATNAM 530042 AP | 530042 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.0 L+₹3.1 L (9.71%)Rejected-AOC FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹37.2 L+₹5.3 L (16.5%)Rejected-AOC | L3 | Rejected-AOC Not being L1 | |
| 4 | L4₹37.5 L+₹5.5 L (17.4%)Rejected-AOC | L4 | Rejected-AOC Not being L1 | |
| 5 | L5₹39.6 L+₹7.7 L (24.0%)Rejected-AOC | L5 | Rejected-AOC Not being L1 |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
22 Mar 2022, 6:00 pmClosed
GARRISON ENGINEER UTILITY SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
PROVISION OF 40 X 90 W LED STREET LIGHTS WITH POLES AT VARIOUS LOCATIONS OF MCEME UNDER GE (U) SECUNDERABAD AND SPECIAL REPAIRS FOR REPLACEMENT OF OLD VINTAGE WATER PIPE LINE AND ALLIED WORKS AT MILKA SINGH COLONY, NML AND ADJOINING AREAS UNDER GE (U
2022_MES_510193_1
GE (U) /SEC/TOKEN/70 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Works
180 days
SECUNDERABAD
AS PER NIT
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER UTILITY SECUNDERABAD
₹77,000
Yes
1 Sept 2022
24 Feb 2022
29 Mar 2022
24 Feb 2022
22 Mar 2022
10 Mar 2022
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in Hard / Dense soil complete all as specified and directed.
All as per item No 1 above but depth exc 1.5 mtr but not exc 3 mtr.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Spreading riddled earth ( after preparation of excavated earth) in Cable duct for cushioning of cable laid in trenches complete all as directed by Engineer-in-Charge Note:- Punned thickness 18 CM( 6.25 Cm below cale and 11.75 cm above cale) will be measured for payment purpose. The earth removed during excavation to be used as rddled earth after crushing and sieving. Quoted rate inclusive of all arrangement as mentioned.
Supply and Laying bricks, common burnt clay building bricks, sub class 'B' of old size 230 x 115 x 75 mm laid across in trenches for cable protection complete all as specified and directed.
Cutting the existing road straight by manual, depth and width not less than 0.75 mtr below ground level for passing of underground cable and filling back with excavated soil up to 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed.
M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregate for filling & foundation of mass complete all as directed
M&L PCC 1:3:6 type C2 using 40 mm graded stone aggregate for filling & foundation of pole & stay complete all as directed
M&L PCC 1:2:4 type B2 using 20 mm graded stone aggregate for coping of pole complete all as directed
Supply , laying, CONNECTING BY USING LUGS , NUT& BOLTS , testing LTUG cable XLPE insulated 1100 volts grade heavy duty 4 core 10 Sqmm with aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanized steel strip and overall PVC sheathed, nominal cross sectional area incl connecting and testing, complete all as specified and as directed. Note : (i) Earthwork, cable protection, pipe etc shall be measured and paid for separately under relevant items.
S&F LED Street light fixture 90 watt made of pressure die-cast aluminium alloy for housing (heat sink) for effective thermal management, sturdiness, excellent corrosion resistant, cable gland is used for maintaining ingress protection, epoxy powder coated siemens grey finish after phosphochromate treatment, tempered protective toughened glass, thermal shock and impact resistant fixed to the housing with SS screws, high efficiency long life LED chip in modules with lumen efficacy of >110 lm/W with PC lens and system lumen 9000 (system efficacy>100 lm/W). Powered by built in electronic LED driver with APFC (SMPS) based constant current supply), lower THD, Open Circuit protection, Phase to Phase protection, Over voltage protection, surge voltage protection, CCT 5700, CRI>70, THD<10%, PF>95, IP66, IK07 life class of 50,000 hrs @ L70, Operating Temperature : 10 to +10 Deg.C, Input Rated voltage : 240 VAC/50 Hz, Driver safety requirement standards : IS 15885-2-13, Test report to be submitted, driver performance requirements : IS 16104, Test report to be submitted, Photo biological safety norms : IS 16108, test certificate to be submitted, certification : LM 79 for luminaries LM 80 for LED Source, Make : sURYA MODEL NO : SLEUL90W IP66(LXN)/ BAJAJ CAT NUMBER : BRTFG 90W LED/ PHILIPS CAT NO: Wipro cat No. LR02-102-XXX-57-XX/ equyivalent in havells/ as approved by GE
Supply and laying GI tubing light grade of size 40 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm. Make : TATA/Jindal/Bansal with ISI marked.
Supplying, erecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 mtrs long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed. Note: i)Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule. ii) Quoted rates inclusive of 2 nos holes ( one near Junction box and one near buttom of the bracket) to be provided for entry and exit of street light connection cable
All as per item No. 12 here-in-before but Flood light of high power LED as light source of capacity 120 watts.. Make: Make : Havells Model Number JETAIRISFLS 120WLED757APWBLT G, SURYA CAT NO SLEFL120 W IP66 LUMOS MAX or Wipro cat No. LF20-132-060-57-G2 OR CG MODEL nO LFLN-120-CDL/60-M / as approved by GE
All as per item No. 12 here-in-before but Flood light of high power LED as light source of capacity 150 watts.. Make: Make : Bajaj Cat No.BARFEG 150W LED or Havells Cat No. JETAIRISFLS150WLED757PSYMLTG, SURYA CAT NO SLEFL150 W IP66 LUMOS MAX or Wipro cat No. LF20-192-060-57-G2 OR CG MODEL nO LFLN-150-CDL/60-M/as approved by GE
All as per item No. 12 here-in-before but Flood light of high power LED as light source of capacity 200 watts.. Make: Make : Havells Model Number JETA VALOURFL200WLED757PINTWBLT G, SURYA CAT NO SLEFL200 WATT IP66 LUMOS II or Wipro cat No. LF20-272-060-57-G2 OR CG MODEL nO LFLN-200-CDL/60-M/as approved by GE
Supply and fixing lantren of dia 60 CM for fixing of flood light, cap type to be fixed on the top of 9 m SP-31 Steel pole / SP -55 11 m steel pole , made of MS pip medium grade dia greater than the top dia of the pole of length 0.35 M supported by MS flat iron of size 50X6 mm 8 nos including two coat of aliminium painting over a coat of redoxide primer complete all as directed
Supply and lay PVC Insulated , PVC sheathed industrial HV round multicore flexible cable with copper conductor THREE core 2.5 sqmm including PVC flexible conduit 20 mm dia( for entry and exit point of pole) medium grade and necessary bends, fittings and fixtures as required for connection of light fittings . ( Used for connection of street light from JB through inside the pole)
S&F hot press moulded SMC junction/terminal box of size with internal diamensions of 200 x 140 x 95 mm with hinged door, incl provision of 4 way connector 415 Volts, 32 AMPS made out of polycarbonate or bakelite and 1 No MCB SP of 10 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs AND pvc glands, fixed on pole by means of 2 SETS OF clamps made out of MS flat iron of size 25mm x 3 mm COMPLETE all as specified and as directed. Make : Syntex/C&S/Havells.
M&L for street light bracket made out of 40 mm dia GI pipe medium grade 1.2 mtr long complete with 2 sets of FI clamps made out of 40x5 MS flat & nuts, bolts & washer including painting to clamp two coat of aluminium silver paint over a coat of primer complete all as specified and as directed.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including welding, bending cold or hot, drilling holes for hinged, in any shape or size as required for laying / protection of cable , fixing of light etc and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
S&F galvasised steel strip 32X6 mm as Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and directed. by Engr-in-Charge.
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. The earting pit cover should be factorty built ( size TOP- 10 Inch, Bottom -13 Inch, Height 10.25 Inch ) made of heavy duty Polypropylene complete all as specified and directed make ASHLOK / INDELEC/JMV /TERCEL/TRUE POWER
Supply and Lay Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed. Note: This wire to be laid along with UG Cable through trenches for earth continuity
M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by haidrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, HDPE pipe upto 110 mm dia of max length 15 m including jointing materials to carry LT UG cables of size upto 240 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed including refilling and making good of disturbed surface . Note : Quoted rate exclusive of HDPE pipe but including of necessary machinaries required for the above work
Supplying and laying of following size HDPE pipe pn 10 ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground , wall , floor complete all as directed
Taking up or down steel tubing laid in trenches, on wall/in floor, in plinth protection of Bldg including segregation of serviceable pipes and keep in safe custody for reuse, complete with all fittings and connections of the following sizes:-
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Refixing of old steel tubing after cleaning and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Notes for item No 9.01 to 9.06 :- (a) Excavation and Earth work shall be measured and paid separately.
Refixing of old steel tubing after cleaning and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in floors, walls and ceilings and testing for leakages complete all as specified and directed for the following sizes:- NOTE : rate quoted by the contractor incluisive of all kind of fittings, bends, flenge , thread cutting, scaffolding, , roof / wall drilling as required for crossing / passing of pipes etc as required for proper fixing of pipe
20 mm dia
25 mm dia
Supply and laying steel water tubing medium grade, galvanised with all fitting, laid in trenches and testing for leakages complete all as specified and directed for the following sizes:- NOTE : rate quoted by the contractor incluisive of all kind of fittings, bends, flenge , thread cutting etc as required for proper fixing of pipe
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Notes for item No 11.01 to 11.06 :- (a) Excavation and Earth work shall be measured and paid separately.
Supply and laying steel water tubing medium grade, galvanised with all fitting, fixed to wall and ceilings or laid in floor and testing for leakages complete all as specified and directed for the following sizes:- NOTE : rate quoted by the contractor incluisive of all kind of fittings, bends, flenge , thread cutting, scaffolding , roof / wall drilling as required for crossing / passing of pipes etc as required for proper fixing of pipe
20 mm dia
25 mm dia
Notes for item No 12.01 to 12.02 :- (a) Excavation and Earth work shall be measured and paid separately.
Cutting existing CI / di / gi pipe line for insertion of new tees, collars for branch connections complete all as specified and directed for the following sizes:- Note: CI /DI specials, GI fittings ,Joints and Earth work shall be measured and paid sperately under relevant items of this schedule.
50 mm Dia
80 mm Dia
Supply and fix in replacement of unserviceable Gun metal, globe or gate valves, with brass ball valve , screwed both ends for GI pipes including making necessary arrangements and fixed complete all as specified and directed for the following sizes:-
20mm dia bore
25mm dia bore
40mm dia bore
50mm dia bore
Note for Sl item No 14.01 to 14.04 , Make : Zoloto / RAMCO/Karter
Construction of valve chamber of size 1200 x 1200 mm (Internal size) 900 mm deep with 200mm thick PCC block masonary walls built in CM 1:6 over 100 mm thick foundation concrete in PCC 1:4:8 type D2, (Using 40 mm graded coarse aggregate) with 100 mm off set, 15mm thick complete internal plaster and external plaster up to a depth of 15 cm below GL in CM (1:6), 3 mm thick MS sheet cover, double door welded to 50 mm x 50 mm x 6mm MS angle frame fixed with hold fasts in PCC 1:2:4 type B1 coping 50 mm thick in PCC (1:2:4) type B-1, 20mm x 6mm flat iron hinges with locking arrangement including lock sixty five mm, brassd and keys(Godrej/Shell), MS handles and applying two coats of synthetic eanmel paint over a coat of red oxide zinc chrome primer to all steel surfaces including excavation & earth work in any type of soil /soft disintegrated rock and disposal of surplus soil to a distance not exceeding 50 Mtr complete all as specified and directed
M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by haidrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock,for passing of GI Pipe of diia up to 80mm and other required materials in co-ordination with the concerned authorites complete all as specified and as directed. Note : GI Pipe will be measured and paid separately under relivent items.
Cutting the existing road straight by manual, depth not less than 0.75 meter and width as required for pipes up to 100 mm dia and refill the same with excavated soil up to 80 % road portion and 20 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate complete all as specified and directed.
Cutting the existing building plinth protection by manual, depth and width as required for replacement of GI /any kind of pipes pipes up to 50 mm dia and refill the same with excavated soil up to 80 % plinth portion and 20 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) and making good of all disturbed surface complete all as specified and directed.
Supply and installation CPRI approved pump starter electric control panel board, for out door use, DOUBLE door ( BOTH DOOR HAVING LOCKING ARRANGEMENT) dust & vermin proof floor mounted made out of CRCA steel sheet of 3.00 mm thick angle iron legs of size50x50x5mm, having electrolytic high conductivity insulated bus bar made out of aluminium strips of rating 100 Amps for 3 phase, 415 Volts, 50 C/S 4 wire system, with cable enty jprovision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly powder coated complete all as including necessary PCC work of height 300 cm from the ground level including disconnecting/taking out old existing unsv pump panel complete all as specified and directed of the following( Leg of the panel should not be less than 0.75 M and size of the panel should not be less than 70CmX60CMX30CM)) :- INCOMMING :- (a) MCB, 4 pole, 415 Volt, 32 Amps, 10 KA - 01 No (d) LED Indicator lamp in three colour RYB - 01 Set OUTGOING :- (a) MCB, 3 pole, 10 KA c Curve 415 volts, 32 Amps -01 No (b) Submerceable pump controller 7.5 hp along with ammeter , voltmeter , on/off pushbutton, indicatoir lamp -01 No. (c) Single hase preventor realy type Sz% (6wire), 415 volts -01 No (d) Connector 4 way 32 amps - 2 Nos
Supply and installation CPRI approved pump starter electric control panel board, wall mounted ,dust & vermin proof made out of CRCA steel sheet of 2 mm thick , having electrolytic high conductivity insulated bus bar made out of aluminium strips of rating 100 Amps for 3 phase, 415 Volts, 50 C/S 4 wire system, with cable enty jprovision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly painted with two coats of stove enameled power coated paint over a coat of red oxide primer complete all as including necessary fixing arrangements including disconnecting/taking out old existing unsv pump panel complete all as specified and directed of the following and size of the panel should not be less than 70CmX80CMX30CM)) :- INCOMMING :- (a) MCCB, 4 pole, 415 Volt, 40 Amps, 16 KA - 01 No (b) 3 Phase LED Voltmeter, class - 0.5 - 01 No (c) 3 Phase LED Ammeter, class -0.5 - 01 No (d) LED Indicator lamp in three colour RYB - 01 Set OUTGOING :- (a) MCCB, 3 pole, 10 KA c Curve 415 volts, 25 Amps -02 No (b) DOL starter in sheet enclosure type MK-1, Motar rating AC-3 duty, 415 volts, 50 Hz suitable FOR 7.5 HP relay max rang 15-25 Amps-02 No. (c) Single hase preventor realy type Sz% (6wire), 415 volts -02 No (d) Connector 4 way 32 amps - 2 Nos
supply and fix submerceable pump controller fully automatic DOL starter AC 3 duty 415 volt suitable for 6 HP motor relay range 9-14 Amps complete all including necessary connections complete all as directed. Make L&T model number ss97756/equivalent from siemens /abb/schneider
supply and fix submerceable pump controller fully automatic DOL starter AC 3 duty 415 volt suitable for 10 HP motor relay range 13-21 Amps complete all including necessary connections complete all as directed. Make L&T model number ss95983/equivalent from siemens /abb/schneider
supply and fix DOL starter AC 3 duty 415 volt suitable for 10 HP motor relay range 09-15 Amps with single phase protection complete all including necessary connections complete all as directed. Make L&T model number ss94351/equivalent from siemens /abb/schneider
supply and fix DOL starter AC 3 duty 415 volt suitable for 10 HP motor relay range 09-15 Amps with single phase protection complete all including necessary connections complete all as directed. Make L&T model number ss94351/equivalent from siemens /abb/schneider
Supply and replace unserviceable GI fittings with new GI fittings ( Nipple of any length up to 25 cm , elbo,bend,socket,union , tee, reducer, plug etc) in cluding making necessary threads in existing pipe as per requirements of any kind ( medium grade suitable for medium grade GI pipe of of size up to 25 mm complete all as directed
Supply and replace unserviceable GI fittings with new GI fittings ( Nipple of any length up to 25 cm , elbo,bend,socket,union , tee, reducer, plug etc) in cluding making necessary threads in existing pipe as per requirements of any kind ( medium grade suitable for medium grade GI pipe of of sizefrom 40 mm to 50 mm complete all as directed
Supply and replace unserviceable GI fittings with new GI fittings ( Nipple of any length up to 25 cm , elbo,bend,socket,union , tee, reducer, plug etc) in cluding making necessary threads in existing pipe as per requirements of any kind ( medium grade suitable for medium grade GI pipe of of sizefrom 65 mm to 80 mm complete all as directed
Supply and replace NRV made of bronze of dia 50 mm complete all as specified and directed
Supply and replace NRV made of bronze of dia 40 mm complete all as specified and directed
Supply and fix in replacement of unserviceable ball brass valves, high pressure with polythene float and fly nut alongwith socket/reducer/nipple of suitable size, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed for the following sizes:-
20mm dia bore
25mm dia bore
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .