Loading…
Loading…
Tender Value
₹2.1 Cr
EMD Value
₹4.1 L
Closing Date
18 Sept 2026, 2:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
S AND T
14 conditions · 2 needing a document upload
For works amounting Rs.50 lakhs and above: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Any work of Signal or Telecom involving trenching, laying & testing of Signal or Telecom cables OR Any other miscellaneous outdoor S&T work.
9 conditions · 2 needing a document upload
Demand for the Financial Criteria, Association of Railway Officers, List of Arbitration cases, Court cases and Mandate for NEFT are to be uploaded with a scanned copy duly filled in and signed as per annexure no. IV, V, VI, VII, VIII, IX, XI, VIA, VIB, VI and Annexure-V and Annexure -V(A) of GCC-2022 respectively. These Annexures are available in View Document menu at Home page and is downloadable. The details of the uploaded documents should be produced whenever demanded for verification on written request at any point of time of the tender and contract within 7 days.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderers are requested to go through the following documents which are available in upload/View Documents in Home page of IREPS portal for works tenders before submitting the e-tender. 1. General Instruction for E-Tenders on works contract--Chapter- I 2. Special Condition-General- Chapter-II
Opening of e-tender : 1. The e-tenders will be opened online using the IREPS portal anytime after tender closing time. No representative is required to be present for opening of e-tender and taking notes of rates quoted and ranking as the complete details of rates etc. of all the bidders shall be available to the bidders through the website after the opening of the tender. 2. The earnest money cost is to be paid through online banking facilities through the online portal and by giving the other details online on website www.ireps.gov.in. Note: For more details refer to Cl: 4 & 12 of General Instruction-Chapter-I for Submission of EMD, Cost of Tender Document and opening of e- tender.
Asansol Division: Improvement of signal visibility and reliable functioning of Fire Alarm systems in ASN Divn.
51-SDSTE-ASN-2026-27~ER
51-SDSTE-ASN-2026-27
Open
Works - General
18 Months
Paschim Bardhaman, West Bengal
₹0
₹4.1 L
18 Sept 2026
26 Aug 2026
4 Sept 2026
140 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,19,25,047 | ||
| — | 40.00 | — | — | ||
| Supply of color light signal post 5.5 mtr. as per RDSO SPEC. NO. IRS:S-6-81 (or latest) and Drg. No. SA-23156 (ADV), Alt-1 or latest. Materials to be procured only from RDSO approved list of firms for manufacture & supply of mechanical signaling items. Inspection: RITES/Consignee. | — | — | — | 5,55,160 | |
| — | 40.00 | — | — | ||
| Supply of 5.5 meter Ladder for Color Light Signal as per RDSO Drawing No. SA-23156 (Adv.) o r latest a n d Stage with Ladder as per Drawing No. S-2033/M (IRS) or latest & as per Specification No. IRS:S-10/78 & IS:210 or latest. Inspection: RITES/Consignee. | — | — | — | 4,85,760 | |
| — | 40.00 | — | — | ||
| Supply of 140 mm diameter Cast Iron (Grade-20) Signal base as per Drawing No. S- 2011/M and as per Specification No. IRS:S-10/78 & IS:210 or latest. Inspection: RITES/Consignee. | — | — | — | 2,52,800 | |
| — | 40.00 | — | — | ||
| Casting, concreting & curing of foundation for Main signal including c o s t o f all materials required for casting and concreting. All materials required for execution will be supplied by the contractor including cement, sand & stone chips, Foundation Bolts, PVC Pipe, shuttering etc. as per Drg. No. S&T/C-42(NKG). | — | — | — | 4,06,640 | |
| — | 40.00 | — | — | ||
| Erection of surface base, signal post, mounting of Color Light Signal up to 4 aspects complete o n signal post, offset bracket, L E D fixing, plumbing o f t h e signal through sealing gap between Surface base and signal post, fixing of ladder with platform complete and concreting of ladder shoe, fixing o f number plates, marker board, termination tail cables, wiring o f signal unit, fixing of EWS locks, and painting of one coat of red oxide and two coats of aluminium/enamel paints , black paint on post, ladder, Platform, ladder shoe a s per practice. When the aspect is fixed on an offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling a hole in the signal pole to prevent the offset bracket from sliding down. Painting of Signal unit with two coats of white inside and Black outside (Supply o f surface base, offset bracket, CLS pole, CLS aspects complete, ladder with shoes and platform, LED aspects, and wire coils will be supplied by Railways). (through bolts and nuts, cement, stone jelly 20/25mm dia. river sand, Signal Color Rings, all fixing bolts and nuts, teak wood, paints PVC/Nylon sleeves and all other miscellaneous materials for the work shall be supplied by the contractor) | — | — | — | 5,32,560 | |
| — | 15.00 | — | — | ||
| Supply o f F R P type color light signal unit 4 aspect complete a s p e r Drg. N o . SA 23001/NM with Latest amendments and as per RDSO Spec.no. RDSO/SPN/194/2006 Rev.2.0 or latest. Inspection: RITES/Consignee. | — | — | — | 5,91,690 | |
| — | 15.00 | — | — | ||
| Supply o f F R P type color light signal unit 3 aspect complete a s p e r Drg. N o . SA- 23002/AIM with Latest amendment a n d a s p e r RDSO Spec. no. RDSO/SPN/194/2006 Rev. 2.0 or latest. Inspection: RITES/Consignee. | — | — | — | 5,23,440 | |
| — | 10.00 | — | — | ||
| "Supply o f FRP type color light signal unit 2 aspect complete a s p e r Drg. N o . SA- 23003/AIM with latest amendments a n d a s p e r RDSO Spec. no. RDSO/SPN/194/2006 Rev. 2.0 or latest. Inspection: RITES/Consignee." | — | — | — | 3,23,740 | |
| — | 10.00 | — | — | ||
| "Supply of 1 WAY FRP TYPE JUNCTION ROUTE INDICATOR as per RDSO Drg. No. SA- 23401(Adv.)/ (Alt.2). Inspection: RITES/Consignee." | — | — | — | 3,35,970 | |
| — | 10.00 | — | — | ||
| "Supply of 2 WAY FRP TYPE JUNCTION ROUTE INDICATOR as per RDSO Drg. No. SA- 23402(Adv.)/ (Alt.2). Inspection: RITES/Consignee." | — | — | — | 4,22,600 | |
| — | 5.00 | — | — | ||
| "Supply of 3 WAY FRP TYPE JUNCTION ROUTE INDICATOR as per RDSO Drg. No. SA- 23403(Adv.)/ (Alt.2). Inspection: RITES/Consignee." | — | — | — | 2,06,485 | |
| — | 10.00 | — | — | ||
| "Fixing of junction type route indicator - 1 way - complete / fixing of additional limb to the existing route indicators, termination of tail cables, wiring, fixing of required number of EWS locks, wire mesh and painting. [Fixing bolts and nuts, wire mesh, PVC / Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor]." | — | — | — | 21,360 | |
| — | 10.00 | — | — | ||
| Fixing of junction type route indicator - 2 way - complete / fixing of additional limb to the existing route indicators, termination of tail cables, wiring, fixing of required number of EWS locks, wire mesh and painting. [Fixing bolts and nuts, wire mesh, PVC / Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor]. | — | — | — | 25,300 | |
| — | 5.00 | — | — | ||
| Fixing of junction type route indicator - 3 way - complete / fixing of additional limb to the existing route indicators, termination of tail cables, wiring, fixing of required number of EWS locks, wire mesh and painting. [Fixing bolts and nuts, wire mesh, PVC / Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor]. | — | — | — | 14,615 | |
| — | 30.00 | — | — | ||
| Supply of cast iron offset bracket for Main Signal with U clamps, nuts, washers complete Drg. No. SA- 23080/ADV/Alt-1. RDSO Spec. No. IRS-S-10/78. Inspection: RITES/Consignee. | — | — | — | 95,040 | |
| — | 5.00 | — | — | ||
| Supply of Shunt Signal Position Light type complete with base, post etc. as per Drg. No.SA-23840 (Adv.) Alt '1' or latest, S-23203 or latest and Drg. No. SA-23845(Adv.) or latest for 90 m m . dia. mounting socket a s p e r Specification No. IRS:S-10/78 w ith Rev.8 o r latest. Inspection: RITES/Consignee. | — | — | — | 42,745 | |
| — | 5.00 | — | — | ||
| Casting, concreting and curing o f foundation f o r Shunt signal including cost of all materials required for casting and concreting. All materials required for execution will be supplied by the contractor, including holding down galvanised bolts & nuts with washers, cement, sand, stone chips, PVC pipe, shuttering etc. As per Drg. No. SK/5/95/NKG. | — | — | — | 25,760 | |
| — | 5.00 | — | — | ||
| Erection of Ground type shunt signal complete including surface base, signal post, LED aspects, number plate, termination of tail cables, wiring of signal unit, provision of EWS locks and painting of one coat of red oxide and two coats of Aluminium / enamel paint, (Supply of Ground type shunt signal complete including surface base, signal post, LED unit i s t o b e supplied b y Railways). (EWS locks, enameled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the contractor). | — | — | — | 13,480 | |
| — | 10.00 | — | — | ||
| "Supply of dependent/position light type Shunt Signal complete as per Drawing No. SA-23840(Adv.) Alt.2 or latest, S-23023 or latest with offset bracket to Drg. No. SA23080 Adv. Alt. 1 o r latest t o suit 140 mm. dia. post complete as per Specification No. IRS:S-10/78 Rev.8 or latest. Inspection: RITES/Consignee." | — | — | — | 69,880 | |
| — | 10.00 | — | — | ||
| "Supply of offset bracket for position light shunt signal (90 mm. outside Dia.) post with U clamps, nuts, washers complete as per RDSO Drg. No. SA-23080/ADV/ALT-1 all drawings should be as per latest. Inspection: RITES/Consignee." | — | — | — | 25,730 | |
| — | 6.00 | — | — | ||
| Supply of Calling ON/Guard Repeater Signal Unit with Brackets & Fixing accessories. Calling ON / Guard Repeater Signal Unit shall conform to RDSO Drg. No. 24351(Adv.) Alt1. suitable for LED Signal Lighting Unit. Inspection: RITES/Consignee. | — | — | — | 19,158 | |
| — | 6.00 | — | — | ||
| Fixing o f Calling-on Signal / A-Sign / AG-Sign unit on signal post including Guard Repeater Signal. The item includes fixing of Co-On signal / 'A' sign / 'AG' sign unit on signal post with bracket, hood etc. Item includes supply of bracket & fixing materials etc. by the contractor. The item also includes termination o f cables & wiring inside Co-On signal / 'A' sign / 'AG' sign unit as per standard practice. | — | — | — | 17,658 | |
| — | 330.00 | — | — | ||
| Painting o f existing color light Signals a s per standard practice. T h e work involves scraping of old paint and two coats of aluminium enamel paint on the Signals & White paint inside signal unit a n d X mark o n signal unit backside with white paint, Painting of Signal Unit, ladder, platform etc. complete a s instructed b y Railway representative a t site (Paint and all other miscellaneous materials required for the work shall be supplied by the Contractor). | — | — | — | 6,04,230 | |
| — | 400.00 | — | — | ||
| Painting o f existing FULL SIZE apparatus cases without disturbing t h e terminations and equipments inside. The work involves scraping o f old paint, applying two coats of Aluminium paint outside & two coats of white paint inside apparatus cases, painting of termination, equipment and number particulars on apparatus cases a s instructed by Railway representative a t site (Paints and all other miscellaneous materials required for the work shall be supplied by the Contractor) Note: Item applicable for alterations and maintenance works. | — | — | — | 7,09,600 | |
| — | 30.00 | — | — | ||
| Supply of LED signal lamps for Main color light Signal RED Aspect, 1 1 0 V AC retrofittable i n existing C L S housing and compatible w ith A C L E D E C R a s p e r R DSO Spec. No. RDSO/SPN/199/2025 Revision.1.2 with Amendment - 1 or latest. Inspection: RDSO. | — | — | — | 2,77,140 | |
| — | 20.00 | — | — | ||
| Supply o f L E D signal lamps f o r Main color light Signal YELLOW Aspect, 1 1 0 V AC retrofittable i n existing CLS housing a n d compatible w ith A C L E D E C R a s p e r RDSO Spec. No. RDSO/SPN/199/2025 Revision.1.2 with Amendment - 1 or latest. Inspection: RDSO. | — | — | — | 1,89,080 | |
| — | 20.00 | — | — | ||
| Supply o f L E D signal lamps f o r M ain color light Signal GREEN Aspect, 1 1 0 V AC retrofittable i n existing CLS housing a n d compatible w i t h A C L E D E C R a s p e r RDSO Spec. RDSO/SPN/199/2025 Revision.1.2 with Amendment - 1 or latest. Inspection: RDSO. | — | — | — | 2,08,280 | |
| — | 50.00 | — | — | ||
| "Supply of LED signals for Route Aspect (Subsidiary Signal), 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Spec. No. RDSO/SPN/153/2023 Revision.5.0 or latest. Inspection: RDSO." | — | — | — | 2,93,200 | |
| — | 25.00 | — | — | ||
| Supply o f L E D signals f o r S h u n t Signal Aspect "(Subsidiary Signal), 1 1 0 V AC retrofittable i n existing CLS housing a n d compatible w ith A C L E D E C R a s p e r RDSO Spec. No. RDSO/SPN/153/2023 Revision.5.0 or latest. Inspection: RDSO." | — | — | — | 1,60,625 | |
| — | 10.00 | — | — | ||
| Supply o f L E D signals f o r Calling O N Signal Aspect (Subsidiary Signal), 1 1 0 V AC retrofittable i n existing CLS housing a n d compatible w ith A C L E D E C R a s p e r RDSO Spec. No. RDSO/SPN/153/2023 Revision.5.0 or latest. Inspection: RDSO. | — | — | — | 76,930 | |
| — | 10.00 | — | — | ||
| "Provision o f SCREEN o n signals w h e n t h e y f a l l within 2 meters from the live conductor by expanding metal (size 20 mm. x 60 mm. strand 3.25 mm. wide and 1.6 mm. thick) as per t h e instruction o f t h e site engineer i n charge. This includes supply o f a l l materials including connection with earth electrode. Provision of SCREEN on signals when they fall within 2 meters from the live conductor by expanding metal (size 20 mm. x 60 mm. strand 3.25 mm. wide and 1.6 mm. thick) a s p e r t h e instruction o f t h e site engineer in charge. This includes supply o f a l l materials including connection with earth electrode. Inspection: Consignee." | — | — | — | 41,550 | |
| — | 20.00 | — | — | ||
| Fabrication, S u p p l y a n d fi x i n g o f C A L L I N G ON instruction b o a r d s , STOP boards/BSLB/Shunting Limit Board/Auto section board o r a n y other board with engineering grade reflective sticker of size 600 X 1000 mm. GI sheet, with MS angle of 75 mm. X 75 mm. X 6 mm. with 6 meter length including paint, excavation of pit and concrete foundation etc. as per the instructions of sight in-charge. All necessary materials to be arranged by the contractor). Inspection: Consignee. | — | — | — | 1,45,340 | |
| — | 20.00 | — | — | ||
| Provision o f foundation for the signal warning boards/calling o n boards/all types of boards. (A pit of size 400 mm. x 400 mm. x 1500 mm. is to be dug and cement concrete foundation in the pit in the ratio 1:3:6 to be casted. T h e rail post/MS angle i s t o b e erected u p right in the foundation. | — | — | — | 30,960 | |
| — | 6.00 | — | — | ||
| Excavation of trench at a of Depth of 1200 mm. and width of 300 mm., including marking of cable alignment, clearing of jungle, roots of trees, bushes, refilling with excavated soil, ramming and consolidation after laying of cables complete to the finished item of work in all type of Soil. NOTE: In case 1.2 m. depth of the trench i s not achievable due t o site conditions approval of officer in charge is to be obtained and payment shall be made on a prorate basis. | — | — | — | 5,86,932 | |
| — | 10000.00 | — | — | ||
| L a y i n g o f S & T C a b l e s o f vario us cores/pairs/quads in trenches/GI pipes/RCC pipes/DWC pipes/Trunking. | — | — | — | 70,000 | |
| — | 300.00 | — | — | ||
| "Trenching under Rails for crossing the track (Track Crossing) and refilling of trenches. The track crossing shall be done at right angles. The depth o f the cable trench shall be 1.2 meter below the rail flange. The ballast shall be stacked separately while making the trench and the earth soil shall be stacked separately. While re-filling the trench, the earth soil has to be filled first to the ground level and the ballast has to be properly put in the track. This work has to be done under supervision of the supervisor of S&T." | — | — | — | 3,38,400 | |
| — | 200.00 | — | — | ||
| "Cutting of platform surface (tile/slab/concrete) for a depth of 20 cm. & width o f 10 cm. & refilling /reconditioning/ repairing the platform after laying pipe & cable. Cutting should be done with marble cutting machine in proper manner & restore the same as before in such a manner that the aesthetic of PF is not disturbed." | — | — | — | 87,400 | |
| — | 600.00 | — | — | ||
| "Supply of Light class GI pipes 100 mm. dia. (thickness 3.6 mm.) as per IS 1239 (Part- 1):2004 or Latest with socket & coupling. Inspection: RITES/Consignee." | — | — | — | 7,95,600 | |
| — | 0.30 | — | — | ||
| Laying of HDPE/DWC/GI Pipes. | — | — | — | 2,277 | |
| — | 300.00 | — | — | ||
| Laying & Fixing of GI pipes 50 mm./100 mm. as per IS 1239 (Part1):2004 with socket & coupling o n culverts and bridges. I t includes installation o f a l l material required for fixing arrangement. The contractor will install a flexible/corrugated HDPE pipe at the end of the GI pipe along with any masonry work (if required) to protect the cables from sharp edges and sudden bends. | — | — | — | 1,08,000 | |
| — | 20.00 | — | — | ||
| Supply of full size apparatus case (GKP type) (as per Drawing No. SW SK NO. 4/90 & other applicable GKP SW Drawing). This includes supply of a location box (GKP type) with 'E' type lock & key, fitted on the location door on both side, E Type lock (ward No. will be specified by Engineer-in Charge) as per RDSO Drg. No. SA-3376 and Key to Drg. No. SA-3377 as per RDSO Drawing No. S- 11500. Inspection: RITES/Consignee. | — | — | — | 3,50,860 | |
| — | 20.00 | — | — | ||
| Casting, concreting and curing o f concrete foundation (in ratio 1:3:6), erection and installation of full size apparatus case as per Drg. No. S&T/C-6/98(NKG). This includes the cost of all materials required for fixing holding down bolts, casting, concreting. Note: Bolts, nuts and washers, bitumen compound t o b e supplied b y contractor a n d bitumen compound t o b e used i n between apparatus case and foundation. This also includes the bottom of apparatus cases filled with sand and the outside covered with masonry work and neat cement plastering. Note: Painting the apparatus case inside and outside with one coat of red oxide, two coats of aluminium paints outside and white paint inside. | — | — | — | 2,74,100 | |
| — | 20.00 | — | — | ||
| relays, fuses with base, fixing of HDHMR shelves for full size apparatus case with Termination & Earthing o f cables and wiring w ith lettering both inside a n d outside a s required including supply of slotted angles, ferrules for marking and miscellaneous materials per location to be supplied by contractor (all materials except Wires, relay, terminal strips, Bakelite strip, fuses with base and HDHMR shelves to be supplied by the contractor). It includes letter painting both inside and outside as per ER practice. NB- Multi strand cables and power cable t o b e terminated with proper lugs and required buss bar etc. to be supplied by the contractor. Inspection: Consignee. | — | — | — | 1,21,780 | |
| — | 20.00 | — | — | ||
| Alteration/modification in the existing location boxes (full size), fixing of equipment's, cable insertion, termination, wiring, testing & commissioning, two coat painting, lettering to suit the circuits as per approved wiring diagrams. This includes filling with sand and plastering the same. | — | — | — | 70,140 | |
| — | 16.00 | — | — | ||
| Supply of Phenolic laminated Sheet/Hylam sheet, grade P3 in standard size of 1220 X 1220 x 10 mm. as per Spec. No. IS 2036 of 1995 or latest. Test report of manufacture to be supplied. Inspection: RITES/Consignee. | — | — | — | 88,832 | |
| — | 1000.00 | — | — | ||
| "Supply of Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) as per RDSO Spec. No. RDSO/SPN/189/2004 With latest amendments. The color will be decided by the Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3) Inspection: RDSO" | — | — | — | 69,000 | |
| — | 100.00 | — | — | ||
| S u p p l y o f E n d p l a t e 2 . 5 m m . / 0 . 0 9 1 i n t h i c k a s per RDSO/SPN/189/2004 With latest amendments. Inspection: RDSO. | — | — | — | 1,300 | |
| — | — | — | RDSO | ||
| — | 100.00 | — | — | ||
| Supply of End Stopper 10 mm./0.0394 in RDSO/SPN/189/2004 With latest amendments. Inspection: RDSO. | — | — | — | 1,300 | |
| — | — | — | RDSO | ||
| — | 20.00 | — | — | ||
| Supply of Carrier Rails for above 35 mm. x 7.5 mm., 1 mm./0.039 i n thickness un- slotted type as per site requirement. Inspection: Consignee. | — | — | — | 2,560 | |
| — | 60.00 | — | — | ||
| "Supply o f earth electrode (GI PIPE) a s per CSTE/ER's (Drg. N o . SI/TYP/0097 dated 25.03.25). Inspection: By RITES [for value of material above Rs.5.0 lakhs]. Inspection: RITES/Consignee." | — | — | — | 1,13,160 | |
| — | 250.00 | — | — | ||
| "Supply of MS FLAT (Spec. No.226 STD or latest) of size 35 mm. x 6 m m . a s per CSTE/ER'S DRG. NO. S&T- 1/2007 (or latest). (STANDARD MINIMUM LENGTH OF 5M OR MULTIPLE OF 5M) Inspection: Consignee." | — | — | — | 67,500 | |
| — | 60.00 | — | — | ||
| "Fixing of earth electrode including laying and installation of MS flat of size 35 mm. x 6 mm. with length 5 mtr. or as per extant practice of Eastern Railway. A s per PCSTE/ER's Drg. No. SI/TYP/0097 dated 25.03.2025 or latest. For apparatus cases, signal post & other equipment as per instruction o f s i t e engineer. Provision f o r fixing MS flat at apparatus cases/ signal post/other equipment should be made by the firm at site. Where required necessary holes to be drilled on the MS Flat. Full threaded bolts of 10 mm. dia. and length 4 0 m m should b e welded i n the apparatus cases in such a way that the MS flat at the apparatus case end can b e fixed from outside o r from inside (bolts o f 1 0 m m . dia. a n d length 4 0 m m . should be supplied b y t h e contractor). Welding arrangement with accessories and welding materials should be arranged by the contractor for fixing of bolts at equipment end where required as per instruction of site engineer. All hardware and other miscellaneous materials required f o r installation to b e supplied b y t h e contractor except earth electrodes and MS flat. Sig. Cable as provided by Railway is also" | — | — | — | 87,840 | |
| — | 60.00 | — | — | ||
| Provision of cement concrete enclosure for earth electrodes as per CSTE/ER's (Drg. No. SI/TYP/0097 dated 25.03.25). Inspection: Consignee. | — | — | — | 43,200 | |
| — | 40.00 | — | — | ||
| Dismantling and releasing of existing Color light Signals complete (up t o 4 aspects) with or without Route Indicators, calling on signals, shunt signals etc., carefully without any damage t o t h e gadgets, accounting and stacking them neatly at a place as instructed b y Railway representative at site. The work includes breaking the concrete foundation, closing the resultant pit and resurfacing it by ramming and levelling. | — | — | — | 92,440 | |
| — | 10.00 | — | — | ||
| Supply of PVC insulated multi strand, single core copper conductor of size 16/0.2 mm as per RDSO Spec. No. IRS:S-76/89 (Amdt.-3) or latest. Each coil should be of Minimum 100 meters length. The color of the wire which is required will be specified by the Engineer in charge. Inspection: RDSO. | — | — | — | 1,06,330 | |
| — | 10.00 | — | — | ||
| — | — | — | 86,12,112.7 | ||
| — | 10.00 | — | — | ||
| Installation, erection and paying out of tail cable from location box and wiring of dependent shunt signal, LED unit on the same post below the main signal as per technical specification and as per Eastern Railway practice. | — | — | — | 5,208.3 | |
| — | 700.00 | — | — | ||
| Supply of 2 Aspect weather proof rain protection covers. Inspection: Consignee. | — | — | — | 1,51,039 | |
| — | 500.00 | — | — | ||
| Supply of 3 Aspect weather proof rain protection covers. Inspection: Consignee. | — | — | — | 1,31,155 | |
| — | 400.00 | — | — | ||
| Supply of 4 Aspect weather proof rain protection covers. Inspection: Consignee. | — | — | — | 1,05,964 | |
| — | 10.00 | — | — | ||
| Supply of underground, unscreened, PVC insulated, PVC inner sheathed armoured and PVC outer jacket railway signalling cable with high conductivity copper conductor of size 12 core x 1.5 sq mm as per Specn. No. IRS:S-63/2014( Rev. 4.0) or latest. Inspection : RDSO | — | — | — | 26,54,976.4 | |
| — | 70.00 | — | — | ||
| Supply of Power card for Ravel make automatic fire alarm and detection system (AFDAS) as per RDSO Spec. No. RDSO/SPN/217/2025 ver.-3.1. Note: The item should be compatible with existing AFDAS in this division. | — | — | — | 8,73,600 | |
| — | 40.00 | — | — | ||
| Supply of Display card for Ravel make automatic fire alarm and detection system (AFDAS) as per RDSO Spec. No. RDSO/SPN/217/2025 ver.-3.1. Note: The item should be compatible with existing AFDAS in this division. | — | — | — | 6,60,000 | |
| — | 70.00 | — | — | ||
| Supply of Mother card for Ravel make automatic fire alarm and detection system (AFDAS) as per RDSO Spec. No. RDSO/SPN/217/2025 ver.-3.1. Note: The item should be compatible with existing AFDAS in this division. | — | — | — | 15,26,700 | |
| — | 70.00 | — | — | ||
| Supply of Loop card for Ravel make automatic fire alarm and detection system (AFDAS) as per RDSO Spec. No. RDSO/SPN/217/2025 ver.-3.1. Note: The item should be compatible with existing AFDAS in this division. | — | — | — | 16,35,480 | |
| — | 100.00 | — | — | ||
| Supply of Multi-sensor for Ravel make automatic fire alarm and detection system (AFDAS) as per RDSO Spec. No. RDSO/SPN/217/2025 ver.-3.1. Note: The item should be compatible with existing AFDAS in this division. | — | — | — | 2,42,500 | |
| — | 20.00 | — | — | ||
| Supply of Hooter/Sounder for Ravel make automatic fire alarm and detection system (AFDAS) as per RDSO Spec. No. RDSO/SPN/217/2025 ver.-3.1. Note: The item should be compatible with existing AFDAS in this division. | — | — | — | 2,87,600 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022.pdf
ATTACHMENT
GCC Correction Slip 1
ATTACHMENT
GCC Correction Slip 2
ATTACHMENT
mergedGCCCorrectionslip3456.pdf
ATTACHMENT
MergedGCCCorrectionSlip78910.pdf GCC Correction Slip 7 8 9 10
ATTACHMENT
GCCCorrectionslip11..pdf
ATTACHMENT
2018-CE-I-CT-9dtd.pdf
ATTACHMENT
Annexure-C.pdf
ATTACHMENT
2022_CE-I_CT_GCC-2022Policy14.07.2022.pdf
ATTACHMENT
ACS-2toGCC-2022_2022-CE-1-CT-GCC-2022-POLICY_13.12.20221.pdf
ATTACHMENT
MergedGCCCorrectionSlip78910.pdf
ATTACHMENT
CheckList.pdf
ATTACHMENT
ALLANNEXURENEW.pdf
ATTACHMENT
Modified_Cable_cut_JPO_NO._941.pdf
ATTACHMENT
sigvisibilityfireAlarm.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .