Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC | L1 | Accepted-AOC Accepted |
Tender Value
₹6.1 L
EMD Value
₹12,300
Closing Date
20 Jul 2020, 5:00 pmClosed
Executive Engineer
EE WSS DIVN. No. 1 Amritsar
Providing House Connection for Existing Pipe Line and New Pipe Line Prov. Laying Jointing Testing PVC pipe Specials for Distribution System Sluice valve Painting of sign board Providing and Fixing Submersible Cable New Control Panel Repair of Pump
2020_WB_48638_1
Sarangra 2042-93 Dated 02-06-2020
Open Tender
Civil Works
Item Wise
90 days
Amritsar
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
TIA
₹12,300
26 Aug 2020
11 Jun 2020
21 Jul 2020
11 Jun 2020
20 Jul 2020
11 Jun 2020
Amount
Cost of Providing & fixing submersible cable complete in all respects as per standard Specifications.
Providing and Fixing of new Control Panel consisting of electric appliances such as automatic Star Delta Push Button or oil immersed Starter, Main Switch, VM, Ampere Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc. (reputed make) complete in all respects as per standard Specifications.
REPAIR OF PUMP CHAMBER
Congolmerate floor 40mm thick cement concrete 1:2:4 on 100mm thick cement concrete 1:8:16 and 100mm sand as stone filling usinf mechanical mixers for mixing of materials.
Providing and fixing of Glass strips 4mm thick in floors
50mm wide
40mm wide
Hollock wood doors shutter windows including Hinges, Screws, Chocks Cleats, Stops and Cords etc. complete fixed in position (double Leaf) @ Paneled glazed or glazed and paneled i) 40mm thick Door, Windows
Distempering with dry distemper of approved manufacture two coats over old distempered surface
Finishing walls with exterior decorative cement based paint such as snowcem robbiacem etc. on old work one coat to give an even shade
Applying Pink Primer or aluminium priming coat on wood work including preparation of surface With special quality paint
Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. With special quality paint
Wiring fan point without fan box in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with step type electronic fan regulator 100watts (socket size). ( as per ac slip no. 3 on CSR Amendments)
Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade. ( as per ac slip no. 3 on CSR Amendments)
Wiring 3 Pin 6 Amp. Plug control comprising wall socket and switch including bonding to existing earth with PVC insulated copper conductor single core FR cable (ISI marked) overall 1 sq. mm, 1100volts grade complete. ( as per ac slip no. 3 on CSR Amendments)
Wiring 3 pin 16/20 amp. power plug control and switch.
REPAIR OF OHSR 150000 LTR CAPACITY
Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B-Class Premium make such as (Jindal/Hisar) Including cost of specials (such as Tees, bends, sockets, elbows etc.) painting with anti corrosive bitumastic paint, testing, cutting threading inside building/railing for staircase (OHSR) 40mm i/d
Providing & fixing Manhole Cover Size MS 560mmx560mm manhole cover and made of 50x50x8mm angle frame fitted with MS sheet hinged cover of 6 mm thickness, Jali, Gauge 15cm width & lightning conductor of GI 7/10” SWG (10mm) dia. standard wire with lightning rod of 25mm. Dia 0.9 m. Long with earth electrode 25mm dia. 2.75mtrs. long GI pipe from ground level connecting 50mm dia 1.40 m long perforated GI pipe including fixing of clamps as per IS:2309-1969 Complete in all respects.
Repair of Expansion joint Complete in all respects.
Providing & fixing of OHSR ladder from parapet to top of OHSR complete in all respects.
Providing & Fixing Aluminium Ladder Inside the tank shall be 60cm wide made from Aluminium section LS 974 size, 66.68x31.75x4mm, weight 1.27 kg/m with steps made out of Aluminium section H, SP 3024 size 35x16.70x1.60mm, weight 0.362kg/m to be fixed on side in the top dome and other side in the bottome dome
DEVELOPMENT OF WATER WORKS
Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing.
Providing & Fixing PCC Fencing Poles With 6' height, 3" x 3" Top & 4" x 3" Base provided with 3 nos. hooks complete in all respects
Providing & Fixing D hook complete with MS bolt size 300 mm x18 mm as per standard drawing D-7 & Analysis of Rates A-9 complete in all respects.
Construction of masonry Corner pillar including cost of cement pointing as per standard drawing & Analysis of Rates complete in all respects(Including Carriage).
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) Class PN-1 as per ISI 150 mm i/d Sluice Valves flanged
Supplying and laying C.I. specials as per IS:1538 complete as desired by Engineer-in-Charge conforming to ISI specifications. CI Specials upto 300 mm i/d
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department(Including Carriage). Size 0.6m x 0.6m
Construction of foot paths with masonry toe wall& earth filling & concrete topping; inside water works as per standard drawing D-10 & Analysis of Rates A-11 complete in all respects.(Including Carriage)
Providing & Installing Testing & Commissioning of One No. Electrically driven diaphragm opreated metering system chemical dosing chlorinator suitable for for delivering 0.5 to 6 liters of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg/cm2 and suction left not less than 1.5 mtr., as per DWSS standard specifations.
Minor Repair & replacement of pipe associated with repair complete in all respects (90 mm pvc pipe)
Provoding & Fixing automated Water Controller complete in all respects as per standard Specifications.
Providing and fixing in position CI Bib Cock(tap)(15 mm i/d)as per IS:210 with stainless steel spindle of approved make and Fixng of Nozzle to contro flow of water(to the approval of Enginer-in-charge Complete in all respect
Providing proposed water connections to household up to wall with providing ,laying, jointing, fixing, testing MDPE pipe line 15 mm i/d = 2.00 mtr(Below GL) and ISI Marked G.I. Pipe 15 mm i/d (As per IS 1239) B-Class approved make = 2.50 mtr (Above GL) including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground and ISI marked 15 mm i/d GM Ferrule as per IS:2692 and 3" i/d clamp with CI Bib Cock 15 mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b) complete in all respects. (Connection at Existing pipe line) = 255
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) Class PN-1 as per ISI
80 mm i/d Sluice Valves flanged
100 mm i/d Sluice Valves flanged
Painting of MS Sign Board
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .