| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.5 LAccepted-AOC ATAL JI KI GALI SHINDE KI CHHAWANI LASHKAR GWALIOR MADHYA PRADESH 474009 | GWALIOR | MADHYA PRADESH | 474009 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹42.4 L+₹3.5 L (9.00%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹43.1 L+₹4.2 L (10.8%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹43.3 L+₹4.4 L (11.2%)Rejected-Finance VILL PO MANOHAR CHHAPRA MOTIPUR DISTT MUZAFFARPUR PIN 843111 | MOTIPUR | MUZAFFARPUR | BIHAR | 843111 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹43.6 L+₹4.6 L (11.9%)Rejected-Finance SULTANPUR NEAR POLICE CHAUKI DANAPUR CANTT PATNA 801503 | PATNA | PATNA | BIHAR | 801503 | L5 | Rejected-Finance OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | RAJ AND SONS L1 | ANAHITAS INFOSOLUTIONS PRIVATE LIMITED L9 | M/S ANAND MOHAN ENTERPRISES L4 | jaglalchoudharyandsons L5 | SINHA CONSTRUCTION L7 | RADHESHYAM PASWAN L2 | VAISHNAVI CONSTRUCTION L6 | HARINANDAN RAI SONS L3 | M/S SAROJ KUMAR SINGH L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00M&L for attending, repair and rectification of external LT electric supply complaints up to 1100 Volts grade, over head/underground system alongwith necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:- | ||||||||||||
| 1.01 | Replacement of worn out jumpers, jointing and tightening with new ACSR conductor.
Note:- Single phase/two wire or 3 phase/4 wire system will be considered as one job for payment purpose. | 10 | Each Job | 850 ₹8,500 Lowest | 1,020 ₹10,200 | 3,500 ₹35,000 | 900 ₹9,000 | 950 ₹9,500 | 915 ₹9,150 | 905 ₹9,050 | 920 ₹9,200 | 900 ₹9,000 |
| 1.02 | Disconnecting from over head conductor, cutting worn out portion of LT cables of any type and size, carry out repairs including taking out cables from under ground loop line and rejoining the same to restore electric supply.
Note :- (i) LT Jointing Kits, Cable protection Pipe if required at site will be measured and paid separately.
(ii) Quoted rate is deemed to be inclusive of cutting and removing the pole coping and inserting the cable alongwith protection pipes. | 10 | Each Job | 1,000 ₹10,000 Lowest | 1,200 ₹12,000 | 5,500 ₹55,000 | 1,250 ₹12,500 | 1,260 ₹12,600 | 1,230 ₹12,300 | 1,245 ₹12,450 | 1,260 ₹12,600 | 1,300 ₹13,000 |
| 1.03Notes for Item Nos 1.01 to 1.02 :- (a) The contractor will be allotted complaints at MES complaint cell on daily basis on all working days and sufficient resources will be deployed by him/her for completion of day to day complaint within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consultation with Engr-in-Charge or JE E&M as detailed. (c) The contractor will make suitable arrangement for emergency complaints and will notify auth rep/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard. (d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Danapur. (f) The contractor will maintain location wise record of each spare utilized as per inventory format given by AGE E/M, Danapur Cantt and the same shall be submitted to E/M No II store on daily basis. | ||||||||||||
| 2.00 | M/L in replacement of cross arms, bracing, supports clamps and back plates fabricated from structural steel section incl nuts, bolts washers, welding, bending cold or hot drilling holes for bolts in any shapes or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including disconnecting/taking out old existing unsv cross arms complete all as specified and directed. | 0.5 | Qtl | 11,000 ₹5,500 | 13,200 ₹6,600 | 15,000 ₹7,500 | 11,000 ₹5,500 | 11,000 ₹5,500 | 10,150 ₹5,075 Lowest | 10,750 ₹5,375 | 11,000 ₹5,500 | 12,000 ₹6,000 |
| 3.00 | Supply & Replace MCCB along with both side spreader link and nut bolts of appropriate size (Conforms to IEC:60947-II/IS:13947-II) in exisitng LT Panel box/Feeder Pillar boxes (KIOSK),in MCCB DBs of capacity 315-400 Amps, 4 Pole, 36KA, 415 Volt including disconnecting/ taking out existing old unsv/burned MCCB complete all as specified and directed. | 2 | Each | 38,000 ₹76,000 | 45,600 ₹91,200 | 7,000 ₹14,000 Lowest | 42,500 ₹85,000 | 42,150 ₹84,300 | 42,350 ₹84,700 | 41,450 ₹82,900 | 42,150 ₹84,300 | 45,000 ₹90,000 |
| 3.01 | All as per item No-3 here in before but of capacity 250 Amps, 4 pole, 36 KA | 2 | Each | 28,000 ₹56,000 | 33,600 ₹67,200 | 6,000 ₹12,000 Lowest | 30,500 ₹61,000 | 32,000 ₹64,000 | 30,200 ₹60,400 | 31,600 ₹63,200 | 32,000 ₹64,000 | 35,000 ₹70,000 |
| 3.02 | All as per item No-3 here in before but of capacity 160 Amps, 4 pole, 36KA | 4 | Each | 12,000 ₹48,000 | 14,400 ₹57,600 | 5,000 ₹20,000 Lowest | 15,500 ₹62,000 | 16,000 ₹64,000 | 15,600 ₹62,400 | 15,450 ₹61,800 | 16,000 ₹64,000 | 20,000 ₹80,000 |
| 3.03 | All as per item No-3 here in before but of capacity 100 Amps, 4 pole, 25 KA | 4 | Each | 10,000 ₹40,000 | 12,000 ₹48,000 | 4,000 ₹16,000 Lowest | 12,500 ₹50,000 | 18,000 ₹72,000 | 12,400 ₹49,600 | 12,750 ₹51,000 | 11,000 ₹44,000 | 15,000 ₹60,000 |
| 4.00 | S&F MCB, SP 10-32 Amps, 'C' Curve with breaking capacity 10 KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed. | 5 | Each | 500 ₹2,500 | 600 ₹3,000 | 800 ₹4,000 | 660 ₹3,300 | 450 ₹2,250 Lowest | 625 ₹3,125 | 615 ₹3,075 | 450 ₹2,250 Lowest | 800 ₹4,000 |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
7 Jul 2026, 6:00 pmClosed
GE DANAPUR
DANAPUR CANTT
REPAIR MAINT OF LT POLE LT OH LINE UG CABLE BUNCH CABLE AND CONNECTED WORKS AT DANAPUR UNDER GE DANAPUR CANTT
2026_MES_772643_1
CA NO GE/DNR/T-21 of 2026-27
Open Tender
Civil Works
Item Rate
180 days
DANAPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE DANAPUR
₹76,000
Yes
5 Aug 2026
16 Jun 2026
14 Jul 2026
16 Jun 2026
7 Jul 2026
1 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1M&L for attending, repair and rectification of external LT electric supply complaints up to 1100 Volts grade, over head/underground system alongwith necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:- | |||||
| 1.01 | Replacement of worn out jumpers, jointing and tightening with new ACSR conductor.
Note:- Single phase/two wire or 3 phase/4 wire system will be considered as one job for payment purpose. | 10 | Each Job | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
BOQ_865178.xls
BOQ • 0.72 MB
Tender9057.pdf
Tender Documents • 0.52 MB
Credit9057.pdf
Additional Documents • 0.21 MB
ParticularSpecification9057.pdf
Additional Documents • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .