Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹37.7 L+₹76,097.26 (2.06%)Accepted-AOC | L2 | Accepted-AOC Other than lowest bid | |
| 3 | L3₹39.2 L+₹2.3 L (6.20%)Accepted-AOC | L3 | Accepted-AOC Other than lowest bid | |
| 4 | L4₹39.5 L+₹2.6 L (6.94%)Accepted-AOC | L4 | Accepted-AOC Other than lowest bid |
Tender Value
Refer Docs
EMD Value
₹82,680
Closing Date
29 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 874 EWS
GE 874 EWS c/o 56 APO
SPL REPAIR TO PERIMETER SECURITY WALL, RECREATION ROOM AND CERTAIN BUILDINGS UNDER THE AOR OF GE 874 EWS.
2024_MES_657297_1
GE 874/EWS-35/2024-25
Open Tender
Civil Works
Works
180 days
Kupwara
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Baramulla
₹82,680
Yes
26 Oct 2024
1 Jun 2024
1 Jul 2024
1 Jun 2024
29 Jun 2024
17 Jun 2024
Amount
Dismantling plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering complete all as specified and directed.
S & F for Pre- painted galvanlume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Taking down chowkat with shutters exc.1.5 Sqm but n exc.4 Sqm(w/o taking off shutters from chowkhat) complete all as specified and directed.
Taking down chowkat with shutters n. exc.1.5Sqm (w/o taking off shutters from chowkhat) complete all as specified and directed.
S & F 2nd class soft wood plain solid straight chowkkats and frames wrought framed, rebated on the solid complete all as specified and directed.
S & F plain framed, panelled shutters 35mm thick 2nd class softwood, (any numbers of panels), with panels of timber flats on both sides of veneered particle board med density, wood particle board with commercial face fitted to chowkhat complete all as specified and directed.
S & F glazed & skeleton shutters 35mm thick 2nd class softwood, open rebated and prepared to receive glass, gauze, etc.(without sash bars), edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part I Section 8 clause 8.20 (a) fitted to chowkhats complete all as specified and directed.
Dismantling timber scantling 40 Sqcm and over in section in any position in unframed work complete all as specified and directed. .
S&F mild steel framed work such as in roof trusses(framed), trusses purlins, crane gantries , rails and fastenings and heavy bracket framing(beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe-410-W(Gde E-250) Quality A complete all as specified and directed.
S&F mild steel framed work for such as brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and directed.
Dismantling of boarding of any description fitted in any position with nails complete all as specified and directed.
S & F 2nd class softwood weather boarding clean sawn, plain, 20 thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps complete all as specified and directed..
S & F 20 mm thick 2nd class soft wood boarding, planed one side, with butt joints and fixed with nails in facia eaves boarding complete all as specified and directed.
M&L for preparation of newly wooden un treated surfaces and applying two coat of synthetic enamel paint over a coat of pink primer of any description not other wise described over 10 cm width or girth etc complete all as specified and as directed.
Dismantling wall and ceiling board (fiber, pulp, insulation, etc.) or insulation board /slab/blankets, any thickness, including cover fillets complete all as specified and directed.
M&L for 2nd class soft wood wall panelling of good quality wood planed one side and edges tonged and grooved or rebated other side and dovetailed joints, chamfered both sides fixed to frame work with secret nailed as in wall panelling 15mm including cornice and beading as required and applying two coats of varnish over a filler coat of thin varnish after preparation of surface, complete all as specified and directed. Note: Frame work shall be measured and paid separately.
M&L for plywood grade BWR type BB, 6mm thick fixed with nails to timber frame work in ceiling complete all as specified and directed.
S&F in repairs two way angular stop cock chromium plated 15mm dia complete all as specified and directed.
M&L for plain fillets of exc. 3 & n exc. 6 Sqcm, square rectangular or triangular in section, clean swan, secured nails complete all as specified and directed.
S&F powder Coated Anodised aluminium window and ventilator shutters, side hung type without sash bars , aluminium sections weighing 0.55 kg /m including necessary joining cleats glazing clip rubber packing anodised aluminium snap beading ,screws, anodised aluminium fitting such as peg stays 150mm long hinges type B-21 100mm long (2 No) suitable handle (1 No complete all as specified and directed.
S&F powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.
M & L for MS barrel tower bolt, stove enamelled black, with bright bolt of 100mm long complete all as specified and directed.
All as per item No 24 above but 150mm long.
M & L for MS Sliding door bolt, plate type, stove enamelled black, with bright bolt not less than 12mm dia of 250mm long complete all as specified and directed..
M & L for MS butt hinges med. Weight, cold rolled 100mm long.
All as per item No 27 above but 75mm long.
M & L for mild steel pressed handles, oval type, stove enamelled black of 100mm long complete all as specified and directed.
All as per item No 29 above but 125mm long.
Demolition of cement concrete (Un-reinforced ) in ground floors and pavings n exc.15cm thick below or above ground level complete all as specified and directed.
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedding and pointed in any mortar complete all as specified and directed.
M&L for 75mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base or floor complete all as specified and directed.
M & L for 25 mm thick plain cement concrete 1:2:4 type Bo (using 12.50 mm graded crushed stone aggregate) as in sub base or floor complete all as specified and directed.
M & L for Non skid ceramic coloured tiles 7-8 mm thick, area exc 0.11sqm but n exc 0.18 sqm of each tile in floor etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile on 15mm thick screed bed in Cement Mortar 1:6 complete all as specified and directed.
M & L for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) dark shade polished, Light shade area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match on 15mm thick screed bed in cement Mortar 1:6 complete all as specified and directed.
M & L for glazed ceramic tiles in colour tiles vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match such as skirting /dados over 15 mm rendering in CM 1:4 complete all as specified and directed.
S&F in repairs one piece vitreous china wash down water closed pan (pedestal pattern) Including integrated flush tank white or coloured including ‘P’ or ‘S’ trap etc complete all as specified and directed.
S&F for 100 Ltr rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
M & L for plinth protection 50 mm thick in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) laid in alternate bays (not exceeding 2 Sqm each) finished even and smooth without using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M & L for brick work with subclass ‘B’ bricks straight or curved on plan exc 6m mean radius, built in Cement mortar 1:6 complete all as specified and directed.
M & L for Granite (of any type) work 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Taking down cement or cement lime plaster on brick or stone walls, any description, including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M & L for 15mm thick rendering in Cement Mortar 1:6 on any faces of brick or concrete surfaces of walls & finishing the surface even and smooth without using extra cement complete all as specified and directed.
M & L for applying two coats of cement base paint over a coat of on new plastered surfaces of wall complete all as specified and directed.
S & F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 m long tube complete all as specified and directed.
Supply & Fixing in repairs Vitreous China Ware Wash hand basin white flat back size 550mmx400mm including pedestal, cutting for and pinning ends of brackets or erecting stand including necessary PVC outlet pipe, CP coupling 32mm dia complete all as specified and directed.
S&F in repair stop valves cast copper alloy, fancy type chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15mm bore pipe complete all as specified and directed.
S&F in repair bib taps cast copper alloy, chromium plated, with crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule of 15mm bore complete all as specified and directed.
S&F in repairs pillar tap cast copper alloy, fancy type with capstan heads chromium plated screwed down with high pressure with or without lettered hot or cold with long screwed, shanks and fly nuts screwed for iron pipe 15mm dia complete all as specified and directed.
S&F 1000 Ltr capacity PVC water storage tank (cylinderical vertical with closed top) and fixed in position all as specified in SSR Part -I, including dismantling of old unserviceable tank complete all as specified and directed.
S&F in repair PVC connection 15 mm length 450 mm complete all as specified and directed.
Taking up or down 15mm dia GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20mm dia GI steel tubing and connections, including cleaning for re fixing or removal to store complete all as specified and directed.
S&F GI tube 15 mm dia medium grade galvanished with all fittings laid in floors wall etc. complete all as specified and as directed.
S&F GI tube 20 mm dia medium grade galvanished with all fittings laid in floors /wall etc. complete all as specified and directed.
Dismantling of rain water pipe and sewage line pipe of any type and any size including fitting complete all as specified and directed.
S&F 75mm dia PVC (SWR) pipes single socketed, in any length fixed to walls/floors or in trenches complete all as specified and directed.
S&F PVC (SWR) bends any radius, 110mm bore, fitted with oval access door
S & F bend suitable for 110mm dia PVC (SWR) pipe complete all as specified and directed
S&F PVC (SWR) bends any radius, 75mm bore, fitted with oval access door complete all as specified and directed.
S&F PVC (SWR) reducers any radius 110mm bore complete all as specified and directed.
S&F PVC (SWR) vent cowl 75mm dia complete all as specified and directed.
S&F in repair PVC(SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified and directed.
S & F Grating doom 125 mm dia with waste hole of PTMT minimum weight 40gms complete all as specified and directed.
S & F in repair towel Rail 450mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats, minimum weight 170gms complete all as specified and directed.
S&F in repair Galvanized mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified and directed.
M&L for Veneered decorative plywood, 9 mm thick, grade 1 (with BWR resin) with decorative face veneers on one faces; fixed with screws to timber frame work in ceiling complete all as specified and directed.
M&L for Veneered decorative plywood 9 mm thick plywood, grade BWR, type BB, fixed with screws to timber frame in wall work complete all as specified and directed.
M&L for 9 mm thick plywood, grade BWR, type BB, fixed with screws to timber frame with nails in ceiling complete all as specified and directed.
M&L for second class soft wood in scantling clean swan complete all as specified and directed.
S & F repair aluminium panelled door (frame and shutters) single leaf with powder coated aluminium (minimum thickness of powder coating 50 micron) frame of section size 62.5mm x 37mm x 1.5mm thick, shutter with middle and bottom rail of aluminium section 112.5mm x 37mm x 1.5mm thick and stiles and top rails of aluminium section 83mm x 37mm x 1.5mm thick with suitable locking arrangement with lock (Make: Godrej / Link) 7 levers and self closing devices with rebates including joining cleats of suitable section for fixing and including provision of builders hardware fittings as required, door spring (Make: Sandhoo / Amar) and glazing with 5.5mm thick ordinary plain coloured glass (Make: Modi / Atul), including provision of EPDM rubber / neoprene gasket as required, including provision of necessary fittings, fixtures etc., fixed in repairs, complete all as specified and directed.
Aluminium sliding window (frame and shutters) with powder coated aluminium (minimum thickness of powder coating 50 micron) frame of aluminium section 62.5mm x 37mm x 1.5mm thick with shutters having style and rails of aluminium section 47.62mm x 44.45mm x 1.5mm thick including joining cleats, glazing clips, rubber packing, aluminium snap beading, screws anodized aluminium fittings such as hinges, tower bolts, handle etc., including 5.5 mm thick sheet glass, complete all as specified and directed.
Fixing for 2nd class softwood weather boarding, clean sawn, plain, 20mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps.
M & L for 2nd class softwood weather boarding, clean sawn, plain, 20mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps complete all as specified and directed..
M&L for applying three coats of white wash on wooden surfaces complete all as specified and directed.
M&L for 25mm thick 2nd class softwood boarding, planed one side, with butt joint fixed with nails in fascia, eaves boarding complete all as specified and directed.
Demolition of cement concrete (Un - reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed.
S & F PVC (SWR) 110 mm dia pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
M&L hard core ( broken stone or boulders) of gauge n exc 63 mm deposited spread and levelled in layers n exc 15 cm thick watered and rolled / rammed to a true surface complete all as specified and directed.
M&L for new plastered surfaces of wall including preparation of new surfaces with applying two coats of colour wash including preparation of plastered surfaces complete all as specified and directed.
M&L for 25 mm sand cushion under paving block including watering and consolidation for interlocking tiles complete all as specified and directed.
M&L 60mm thick, machine pressed precast concrete interlocking paver block, with grey cement and pigment, any shape and size confirming to IS 15658-2006, M-35 Grade complete all as specified and directed.
S & F stainless steel drappery rod or curtain rods, 25 mm dia, with end brackets, decorative type, cut to length as required size, colour coating including matching socketed brackets, complete all as specified and directed.
S & F mild steel framed work for such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint on new steel surfaces of any description over 10cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete all as specified and directed.
M & L for PCC 1:4:8, type D - 2 as in foundation, filling and mass concrete (using 40 mm graded crushed stone aggregate).
M & L for PCC 1:2:4, type B - 1 ( using 20 mm graded crushed stone aggregate) as in coping including necessary formwork, weathering, slightly rounded or chamfered angles complete all as specified and directed.
M & L for PCC 1 : 3 : 6, type C-2, (40 mm graded stone aggregate) as in surface channels and drains including necessary from work
M & L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement, including forms, moulds etc complete all as specified and directed..
M & L for chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey pigment and pigment cement complete all as specified and directed.
M&L for pre-cast cement concrete solid block masonary 1:3:6 type C1, (using 20 mm graded aggregate) exc 10 CM width and setting in CM 1:6 complete all as specified and directed.
M&L for 10 mm thick rendering on fair faces of brick work/concrete surfaces in CM 1:4 finishing the surface fair & even complete w/o using extra cement complete all as specified and directed.
Demolition of brick work built in cement mortar complete all as specified and directed.
Demolition of RCC of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling of barbed wire fencing complete all as specified and directed.
Excavation in trenches n. exc 1.5m wide & n. exc 1.50m in depth for foundation , etc or for shafts, wells, cess pits, man holes, pier holes etc n. exc 10 sqm on plan & getting out in hard/ dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate in foundation filling and mass concrete complete all as specified and directed.
M&L for reinforced cement concrete (design mix ) M-25 (20mm graded aggregate) as in foundations, including / rafts, footings, beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for reinforced cement concrete (design mix ) M-25 (20mm graded aggregate) as in columns, pillars piers, posts and struts etc complete all as specified and directed.
M&L for reinforced cement concrete (design mix ) M-25 (20mm graded aggregate) as in Beams, cantilevers, bressummeres, lintel over 1.5m span etc complete all as specified and directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of column, raft beams, side and soffits(if any) of foundation and plinth beams, and similar work vertical or to better for flats rough finished flat surfaces of concrete complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, bean, haunchings, girders bressummers, lintels, cantilevers, shelves including supports overhangs, etc. rough finished flat surfaces of concrete complete all as specified and directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, colulms and stanchions. rough finished flat surfaces of concrete complete all as specified and directed.
S&F MS TMT bars 10 mm dia and over cut to length bent to shape required including, cranking bending spirally for hooping for column hooking ends binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
All as per item No 110 above but 6 to 8mm dia and over up to and including 10m m dia in stirrups spacers and binders.
M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement.
S&F mild steel work as in swan necks etc all as specified and as directed.
S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. Each line wire to be measured.
M & L for providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10m opanable length ( total length 90m) having 50 nos rounds per 6 m length, up to 3.0m height of wall with existing angle iron Y shaped placed 2.4m or 3.00m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tired with G.I. stapels and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of engineer in charge, with reinforced barbed wire tape (R.B.T)/spring core (2.5 mm thick) wire of high tensile strength of 165kg/sq.mm with tape (0.52 mm thick 0 and weight 43.478 gm/metre (cost of M.S. angle, CC Blocks shall be paid separately).
Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specified and directed.
Taking down MCB DB's complete with MCB's/Isolator etc removing materials from site and making good disturbed surface of walls, floors etc. complete all as specified and directed.
M&L for point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC FRLSH insulated un-sheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC FRLS insulated un-sheathed copper conductor single core multi stranded flexible cable (green color) as earth lead in and including cable 1100 volts grade including casing and capping/conduit (ISI marked) including sunk cast iron/pressed steel terminal boxes, junction boxes, other boxes made from 1.6 mm thick sheet of suitable sizes for mounting of switches, sockets, fan regulators, light fittings etc. covered with 3mm thick plastic laminated sheet or PVC gang box 2 to 8 way as per site requirement including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified.
All as per item No 118 herein before but wiring with 1.5 sqmm copper wire ( FRLSH) and 1.5 sqmm earth wire for socket outlet 3 pin 5 amps on same board.
All as per item No 118 herein before but wiring with 1.5 sqmm copper wire ( FRLSH) and 1.5 sqmm earth wire for socket outlet 3 pin 5 amps on independent board.
All as per item No 118 herein before but wiring with 2.5 sqmm copper wire ( FRLSH) and 1.5 sqmm earth wire for switch socket combination 6 pin 15 amps on independent board.
All as per item No 118 herein before but One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables1.5 sq.mm. size (FRLSH) .
S & F Bell, AC, 230 volts, single pole complete all as specified and directed.
S&F switch piano flush button single pole, one way 5 amps complete all as specified and directed.
S & F socket out let 2 in 1, 3 pin, 6A complete all as specified and directed.
S & F switch socket combination 2 in 1, 5A, flush type complete all as specified and directed.
S & F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed.
S&F LED, 20 Watts, 4 ft, fittings complete with all accessories for mounting light fittings complete with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body complete all as specified and directed.
Supply and fix ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body complete all as specified and directed.
M & L Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and directed.
Supply and fix LED Bulb 9 Watt complete all as specified and directed.
S&F 09W/10W Bulk head luminiares including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed..
S&F Wiring for circuit/sub main wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface /recessed as required in PVC casing caping of size 2x4 sq. mm + 1x2.5 sq. mm earth wire
M&L Earthing complete with galvanised steel earth plate electrode 60x60cmx6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge lead of the plate not less than 1.5 mtr below normal ground level, connected galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
S&F of distribution board single pole & neutral with 200 Amps rated bus bar, for double door IP-42 DB's ,made out of sheet steel enclosure, recessed type, factory made powder coated 8 way -240 volts suitable for housing MCB's and isolator's complete in all fixing material/accessories etc complete all as specified and directed.
S&F MCB's single pole 240 volts 6 to 32Amps 10 KA 'C' series, complete all as specified and directed.
S & F of MCB SPN, 240volt, 40 to 63 Amp capacity, 10 KA, 'C' curve complete all as specified and directed.
S&F exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230v, 50HZ , RPM 1200, Copper winding of sweep 300mm, complete all as specified and directed.
S&F electric water Heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 liter , BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc complete all as specified and directed.
Taking down Geyser 25 - 50 Ltr capacity from wall and re fixing the same on wall same location or another location of same building including provision and grouting of nuts and bolts, connecting pipe etc complete all as specified and directed
Supply and fix decorative, wall mounting ,SS finish fixture with opal glass diffuser suitable for 40 W incandescent candle lamp or 8 W TU retrofit CFL /LED complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Taking down ceiling fan 1200/1400 mm sweep and dismantliing of fan blade, down rod and Material and labour for greasing, painting, overhauling of ceiling fan and re hanging its original position complete all as specified and directed.
Disconnecting unserviceable sub main wiring/service connection of any size and including steel conduit and accessories and removing from site and making good the disturbed surfaces complete all as specified and directed.
S&F of distribution board single pole & neutral with 200 Amps rated bus bar, for double door IP-42 DB's ,made out of sheet steel enclosure, recessed type, factory made powder coated 12 way -240 volts suitable for housing MCB's and isolator's complete in all fixing material/accessories etc complete all as specified and directed.
S&F of distribution board single pole & neutral with 200 Amps rated bus bar, for double door IP-42 DB's ,made out of sheet steel enclosure, recessed type, factory made powder coated 4 way -240 volts suitable for housing MCB's and isolator's complete in all fixing material/accessories etc complete all as specified and directed.
Supply and Fixing 1100 Volts grade heavy duty cable PVC insulated multi stranded aluminium conductor served with PVC tape and overall PVC sheathed in services connections suspended by insulating hanger not more than 1 mtr apart including 4mm dia GI suspension wire one twin core cable flat or circular of size16 Sqmm 2 core including service bracket complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 60x60cmx6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge lead of the plate not less than 1.5 mtr below normal ground level, connected galvanised earrth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion.
Taking up/down old unserviceable cable, supply, Laying , jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable, of size 16 sqmm 2.0 core, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m depth for foundation, laying of cables/pipes/poles etc., and getting out in hard/dense soil complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding of 25 cm thick in soft/loose soil complete all as specified and directed
Removal of surplus soil as obtained from excavation to a distance not exc. 50 Mtr and depositing where directed at a level not exc. 1.5 Mtr above the starting point all as specified and directed.
Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable including spreading levelling watering and consolidation complete all as specified and directed. Note:-Punned thickness only shall be measured and paid.
Supply and laying old size brick covering with width equal to length of brick as the mechanical protection to cable with well burnt sub class 'B' laid in trenches flat complete all as specified and directed.
Supplying and fixing, light grade, Galvanised mild steel pipe / tubing, 50 mm bore complete with all fittings, laid under roads, drain, paths, fixed to poles/ walls with suitable mild steel clamps , bolts , nuts and washers complete all as specified and directed as for cable protection complete all as specified and directed:-. (Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule ):-
M/s KASHMIR BUILDERS
M/S SAJAA CONSTRUCTION COMAPNY
M/S ABDUL KARIM RATHER
Bidder Name
M/s KASHMIR BUILDERS
M/S ABDUL KARIM RATHER
M/S SAJAA CONSTRUCTION COMAPNY
M/S MUNEER AHMAD WANI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .