| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.7 CrAccepted-AOC SAHEBPARA RAOD UPPER BAGDOGRA P O BAGDOGRA DISTRICT DARJEELING WEST BENGAL PIN 734014 | BAGDOGRA | DARJEELING | WEST BENGAL | 734014 | ₹1.7 Cr | L-1 | Accepted-AOC L-1 Bidder |
| 2 | L-2₹1.8 Cr+₹2.5 L (1.41%)Rejected-Finance POST BOX NO 86 VALLIMA COTTAGE 4 7 HOOKER ROAD POST DIST DARJEELING PIN 734101 | DARJEELING | WEST BENGAL | 734101 | ₹1.8 Cr+₹2.5 L (1.41%) | L-2 | Rejected-Finance Rejected. Other than L-1. |
| 3 | L-3₹1.8 Cr+₹8.4 L (4.80%)Rejected-Finance C O BLUE STAR MEDICAL HALL BAGDOGRA DIST DARJEELING WB | BAGDOGRA | DARJEELING | WEST BENGAL | ₹1.8 Cr+₹8.4 L (4.80%) | L-3 | Rejected-Finance Rejected. Other than L-1. |
| 4 | L-4₹1.8 Cr+₹9.1 L (5.18%)Rejected-Finance | ₹1.8 Cr+₹9.1 L (5.18%) | L-4 | Rejected-Finance Rejected. Other than L-1. |
Tender Value
₹2.1 Cr
EMD Value
₹2.9 L
Closing Date
29 Apr 2024, 6:00 pmClosed
HQ CE SILIGURI ZONE
HQ CE SILIGURI ZONE, MES, SEVOKE ROAD, PO SALUGARA, DIST JALPAIGURI, PIN 734 008 (WB)
SPL REPAIR TO STAFF QTR OF KENDRIYA VIDYALAYA AT BENGDUBI MIL STN UNDER GE BENGDUBI
2024_MES_646324_1
98775/BENG/SZ/E8
Open Tender
Construction Works
Item Rate
365 days
BENGDUBI
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
GE BENGDUBI
₹2.9 L
Yes
HQ CE SILIGURI ZONE
5 Jul 2024
14 Mar 2024
6 May 2024
14 Mar 2024
29 Apr 2024
15 Apr 2024
15 Mar 2024 - 25 Mar 2024
28 Mar 2024
Amount
EARTH WORK : (Earth Work of differents Sch 'A' Parts will be measured and paid under this Part) Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out soft/loose soil complete, all as specified and directed.
Removing excavated soil to a distance not exceeding 50.00 mtr and depositng where directed complete, all as specified and as directed.
Removing excavated soil to a distance exceeding 500 mtr and upto total distance of 1.5 km and depositing where directed complete, all as specified and directed.
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, manholes, erecting of poles etc. not exceeding 10 Sq.m on plan but not exceeding 1.5 mtr in depth and getting out in loose/soft soil complete, all as specified and directed.
Excavation in trenches, exceeding 1.5 mtr wide and exceeding 1.5 mtr in depth for foundation, laying of pipe, erecting of poles etc.not exceeding 10 Sq.m on plan but not exceeding 3.0 mtr in depth and getting out in loose/soft soil complete, all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft and loose soil complete, all as specified and directed.
Removing excavated soil to a distance not exceeding 50.00 mtr and depositng where directed at level not exceeding 1.5 mtr. above the starting point complete, all as specified and directed.
BUILDNG (B/R) PORTION : Dismantling of floor, hearth or wall tiling / Paving Blocks including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish of the premises complete, all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete, all as specified and directed.
M&L for Non-skid Ceramic, colorised tiles 7 to 8 mm thick area of each tile exceeding 0.18 sq.m but not exceeding 0.38 sq.m, in floors etc. set and jointed in neat cement slurry and pointed in white cement mixed with admixture of pigment or coloured cement to match complete, all as specified and directed. (Note: Screed bed will be measured and paid under relevant item.)
M&L for Non-skid Ceramic, colorised tiles 7 to 8 mm thick area of each tile exceeding 0.18 sq.m but not exceeding 0.38 sq.m, in skirting / vertical surface etc. set and jointed in neat cement slurry and pointed in white cement mixed with admixture of pigment or coloured cement to match complete, all as specified and directed. (Note: Backing Screed (plastering) will be measured and paid under relevant item.)
M&L for Non-skid Ceramic, colorised tiles 7 to 8 mm thick (square /rectangular) area of each tile exceeding 0.11 sq.m but not exceeding 0.18 sq.m, in floors etc. set and jointed in neat cement slurry and pointed in white cement mixed with admixture of pigment or coloured cement to match complete, all as specified and directed. (Note: Screed bed will be measured and paid under relevant item.)
M&L for Glazed Ceramic, coloured tiles (300 mm x 450 mm) size and 6 to 7 mm thick as in skirting/ dado, set and jointed in neat cement slurry and pointed in white cement mixed with admixture of pigment or colour cemet to match complete, all as specified and directed. (Note: Backing Screed (plastering) will be measured and paid under relevant item.)
M&L for 15mm thick screed bed or bedding layer in cement morter (1:6) for laying floor finishes complete, all as specified and directed.
M&L for 10 mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surface as backing screed of dado /skirting complete, all as specified and directed.
M&L for 20 mm thick, granite (of any type) stone slab (table rubbed and polished), in skirting/ dado kitchen platform etc. set over and including 20 mm thick screed bed in cement mortar (1:4) laid and jointed with grey cement slurry and pointed with white cement (1:2) using marble dust with admixture of pigment to match the shade of granite stone complete, all as specified and directed. (Note No : 1. The unit quoted rate of Screed bed included in this item. 2. Edge Moulding of stone slab will be measured and paid under relevant item.)
Providing edge moulding to 18-20 thick stones of counter vainities etc. including machine polishing to edge to give high gloss finish etc. complete, all as specified and directed.
M&L for 20-25 mm thick, Machine cut kota stone slab fooring laid over and including cement screed bed or bedding layer of 20 mm thick in cement mortar (1:6) including jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of the slab including rubbing and polishing complete, all as specified and directed. (Note : The unit quoted rate of Screed bed included in this item.)
M&L for 18-20 mm thick, Machine cut kota stone slab fooring in riser and steps, skirting, dado, set over and including 10 mm thick backing screed (plastering) in cement mortar (1:4) on fair faces of brick work or concrete surface laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, all as specified and directed. (Note : The unit quoted rate of Backing Screed included in this item.)
Taking down chowkats or frames with shutters (without taking off shutter from frames) exc. 1.5 Sq.m but not exc. 4 Sq.m each complete, all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutter from frames) not exc. 1.5 Sq.m each complete, all as specified and directed.
Taking down shutter of any description exc 1.00 Sq.m and not exc 2 Sq.m each complete, all as specified and directed.
S&F 1.25 mm thick pressed steel frame of size 165 x 60 mm for door with one ore more rebate includings necessary fixing lugs, hinges, locks strike plante etc complete, all as specified and directed.
S&F 1.25 mm thick pressed steel frame of size 105 X 60 mm for door with one ore more rebate includings necessary fixing lugs, hinges, locks strike plante etc complete, all as specified and directed.
S&F solid PVC frame (single rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete, all as specified and directed. (Note : Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life.)
S&F factory made solid panel PVC door shutter, 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete, as per specification & shown on drawing of MES SSR Part-I,1991 and as directed.
S&F 30 mm thick, flush shutter, solid core, construction, with block board core and ply wood face panels, commercial type on both sides kiln seasoned and chemically pressure treated complete, all as specified and directed.
S&F 25 mm thick flush shutter, solid core, construction with block board core and ply wood face panels, commercial type on both sides kiln seasoned and chemically pressure treated complete, all as specified and directed.
S&F factory made solid stainless steel wire gauged PVC door shutter, 30m thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat mouled plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side as gap insert for stainless steel wire gauge planel in leaf of PVC sheets. The wire gauge shall be wrapped on additional square 8mm MS solid tube this tube shall be welded MS tube. The wire gauge shall be streched and tightened firmly as per manufacturere's specification complete, all as specified and directed.
M&L for rolled MS framed, conforming to Fe-410-W (Gde-E-250) quality-A, as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete, all as specified and directed.
M&L for MS framed work conforming to Fe-290 (Gde-E-165) such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work complete, all as specified and directed.
S&F powder coated (minimum thickness of powder coating 50 micron) anodised alumiuium frame for doors window, ventilator with one or more rebates including joining cleat for fixing etc complete, all as specified and directed.
S&F powder coated alumnium (minium thickness of powder coating 50 micron) for shutters of doors, window & ventilator including poviding and fixing hinges/pivots any making provision for fixing of fittings whereever required incuding the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) wth extruded built up standard tubular sections/appropriate Z sections and other secitons of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, incl necessary filling up the gapsat junctions, i.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Alumiuium sections shall be smooth, rust free, straigth, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, CP brass/stainless steel screws complete, all as specified and directed.
S&F 4mm thick figured glass, pin head type and glazing with oil putty in squares not exc 0.5 sq.m in each pane complete, all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainles steel wire stapel complete, all as specified and directed.
S&F 200 mm long aluminium anodised barreled tower bolt of extruded section complete, all as specified and directed.
S&F 150 mm long aluminium anodised barreled tower bolt of extruded section complete, all as specified and directed.
S&F aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete, all as specified and directed.
S&F 100 mm size butt hinges, heavy weight, cold rolled mild steel, all as specified and directed.
S&F 150 mm size aluminium handle, cast type, anodised, all as specified and directed.
S&F bal catches with 8 mm dia steel ball magnet catches for cup board shutter including strking plate as approved complete, all as specified and directed.
S&F continuous (piano) hinges, mild steel, bright finish or eletro galvanised with of flaps (when open 30 mm) complete, all as specified and directed.
Dimantling of asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings including ridges complete, all as specified and directed.
S&F pre-painted colored trapezoidal profiled Galvalume/ aluminum zinc coating GI based corrugated steel sheet with min 0.50 mm TCT confirmin to IS-513 (AZ-150 GSM, AL Zn alloy metalic coating 550 Mpa yield stress as per AS-1397) as in roof covering/ cladding to wall fixed with self tapping screws colour /exterior coat of silicon modified polyster/ BHP X RW paint system 20 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer, all fixed with Galvanised self drilling self-tapping fastener (12-14 x 55 with EPDM seals) complete, all as specified and directed.
S&F pre-painted colored plain sheet profiled Galvalume/Zincalume sheet with min 0.50mm TCT confirmin to IS-513 (AZ-150 GSM, AL Zn alloy metalic coating 550 Mpa yield stress as per AS-1397), as in roof covering/ cladding to wall fixed with self tapping screws colour /exterior coat of silicon modified polyster/ BHP X RW paint system 20 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer, all fixed with Galvanised self drilling self-tapping fastener (12-14 x 55 with EPDM seals) complete, all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation oards/slabs/ blankets, any thickness including cover fillets complete, all as specified and directed.
M&L for Gl frame work size of grid (605 x 605) mm for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including Hangers 4 mm dia. G.I. (upto 1800mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat (40 x 3) mm size, 60,mm long and expansion hold fasteners 12.5,mm dia. 40,mm long complete, all as specified and directed.
M&L for 4mm thick non-asbestos fibre cement disigner pre-painted building boards fixed or laid/ inserted to timber/ GI/ Aluminium framework with screws complete, all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, all as specified and directed.
M&L for rolled MS conforming to Fe-410-W (Gde-E250) quality-A joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) including necessary welding, febrication complete, all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and including removal of debris and rubbish from the site complete, all as specified and directed.
M&L for 5 mm thick rendering plaster in cement mortar (1:3) on concrete surfaces of ceiling of chajja etc. and finished even and smooth without using extra cement complete, all as specified and directed.
M&L for 15 mm thick rendering plaster in cement mortar (1:6) on fair faces of brick work or concrete wall surfaces and finsihed even and smooth (without using extra cement) complete, all as specified and directed.
M&L for 20 mm thick rendering plaster in two layers of 10mm thick each in cement mortar (1:4) on fair faces of brick work or concrete wall surfaces and finsihed even and smooth (without using extra cement) mixed with water proofing compound mixed with polyster triangular fabric as per manufacture's instruction complete, all as specified and directed. (NOTES : 1. WPC, mixed with polyster triangular fabric shall be measured and paid under relivent item. 2. Only top layer of plaster shall be treatment with WPC)
M&L for 15 mm thick rendering plaster in cement mortar (1:4) on fair faces of brick work or concrete wall surfaces finsihed even and smooth (without using extra cement) mixed with water proofing compound as per manufacture's instruction complete, all as specified and directed. (NOTE : WPC shall be measured and paid under relivent item.)
M&L for 15mm thick rendering plaster in cement mortar (1:4) on fair faces of brick work or concrete wall surfaces and neeru finish to the plastered surfaces complete, all as specified and directed.
Supply only water proofing compound (Liquid), all as specified and directed.
Taking up or down 15 mm bore steel water tubing & connections, all as specified and directed.
Taking up or down 20 mm bore steel water tubing & connections, all as specified and directed.
Taking up or down 25 mm bore steel water tubing & connections, all as specified and directed.
Supply, laying, testing & connection of 20 mm outer dia CPVC pipes, SDR-11 & plain CPVC SDR 11 fittings on wall /ceiling or laying in floor complete, all as specified and directed.
Supply, laying, testing & connection of 25 mm outer dia CPVC pipes, SDR-11 & plain CPVC SDR 11 fittings on wall /ceiling or laying in floor complete, all as specified and directed.
Supply, laying, testing & connection of 40 mm outer dia CPVC pipes, SDR-11 & plain CPVC SDR 11 fittings on wall /ceiling or laying in floor complete, all as specified and directed.
Dismantling water tanks exceeding 250 ltr but not exceeding 500 ltr and removing to store complete, all as specified and as directed
S&F 500 ltrs capacity, triple layered, rotational mouldedpolyethylene water storage tank, ISI marked, (cylindrical vertical with closed top) including inlet,outlet and wash out holes of approved make hoisted and fixed in position all as specified in MES SSR Part-I complete, all as specified and directed.
S&F 20 mm dia of pipe ball valves, high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball, screwed for iron pipe. (Minimum weight 210 gms) complete, all as specified and directed.
S&F in repairs 20 mm bore of pipe gun metal globe or gate valves, with iron wheel head, screwed both ends for GI pipe, all as specified and directed.
S&F hard drawn steel wire fabric, in available size, weight not exc 4.00 Kg /sq. m as in tank caging including welding, riveting, framing etc complete, all as specified and directed.
Demolition of brick work including all quoins arches, pillars etc built in cement mortar complete, all as specified and directed.
M&L for half brick thick walling, with old size fly-ash brick, straight or curved on plan built in cement morter (1:4) complete, all as specified and directed.
M&L for fly-ash brickwork walling, with old size bricks, straight or curved on plan exceeding 6 mtr mean radius built in cement mortar (1:6) complete, all as specified and directed.
S&F in repairs (550 x 400) mm size vitreous china wash basin, white, flat back, oval shape, including cutting for and pinning in ends of brackets excluding taps but including 32 mm dia chromium plated waste fitting and PVC waste pipe 610 mm long and MS brackets complete, all as specified and as directed.
S&F in repairs 1 mm thick, kitchen or laboratory stainless steel sinks, with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495 mm x 420 mm, bowl size 410 mm x 330 mm x 160 mm complete, all as specified and as directed.
S&F 0.5mm thick stainless steel plate rack, overall size 24 x 36 x 10 inch of standard quality and shapes complete, all as specified and directed. Make : Prayag CAT No. P-336 or equivalent make.
S&F in repairs vitreous China, wash down water closet pan (pedestal pattern), white, (excluding flushing cistern & flush pipe) including connection to out going pipe and plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete, all as specified and directed.
S&F in repairs 20 mm dia, tubular towel rail, brass chrormium plated, 'D' type, 600mm long between flanges complete, all as specified and directed.
S&F in repairs 125 mm dia size, brass chromium plated shower roses, with or without swivel joints of standard size, suitable for fixing to 15 mm bore steel water tubing or union complete, all as specified and directed.
S&F in repairs 10 Ltr capacity, PVC valveless double syphonic action type, flushing cistern, low level, of white with inlet, ball valve, float, flushing bend & handle including brackets, suitable for both Indian type Water Closet & Europeon Type Water Closet and connection to pipe complete, all as specified and directed.
S&F in repairs 15 mm bore of pipe, bib tap, fancy type, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down screwed for iron pipe or brass ferrule, complete all as specified and directed.
S&F in repairs 15 mm bore of pipe, bib tap for 2 in 1, fancy type, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down screwed for iron pipe or brass ferrule, complete all as specified and directed.
S&F in repairs 15 mm bore of pipe stop valves/gate valves, fancy type, cast copper alloy, chromium plated (Concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and directed.
S&F 15 mm bore dia of pipe pillar tap, fancy type, cast copper alloy, chromium plated, with long swan neck, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified and directed.
S&F in repairs PVC connections 15 mm bore of size with PTMT nut, 450 mm long complete, all as specified and directed.
S&F in repairs 32 mm bore of pipe, low density, polyethylene (LDPE) pipes of pressure rating 6 kgf/sq. cm complete, all as specified and as directed.
S&F in repairs for 75 mm bore of outlet, PVC floor trap, with gratings, including jointing to waste pipe with solvent cement complete, all as specified and as directed.
S&F in repairs PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete, all as specified and as directed.
Dismantling 100 mm bore cast iron or reinforced concrete drain pipe, jointed in cement mortar and taking out trenches, if reqired complete, all as specified and directed.
Taking down eaves gutter/ rain water pipes (any size or pattern) including all fittings, head, shoes etc. Complete, all as specified and directed.
S&F 75 mm bore PVC (SWR) pipe single socketed, laid in trenches laid in trenches or in floors or fixed vertically in walls with rubber ring joints complete, all as specified and directed.
S&F 110 mm bore PVC (SWR) pipe single socketed, laid in trenches laid in trenches or in floors or fixed vertically in walls, with rubber ring joints complete, all as specified and directed.
S&F 75 mm bore PVC (SWR) bends of (any radius) complete, all as specified and directed.
S&F 110 mm bore PVC (SWR) bends of (any radius) complete, all as specified and directed.
S&F 75 mm bore PVC (SWR) branch pieces, single (single Y) equal or unequal, complete, all as specified and directed.
S&F 110 mm bore PVC (SWR) branch pieces, single (single Y) equal or unequal, complete, all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description & in any position not specifically provided for, including racking out of old Terfelt/ APP Membrane surfaces wherever required complete, all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description & in any position not specifically provided for complete, all as specified and directed.
M&L for 75 mm thick PCC flooring, type C-2, 1:3:6 (using 40 mm graded crushed stone aggregrate) as in plinth protection and finishing cement concrete surface even and smooth, without using extra cement complete, all as specified and directed.
M&L for reinforced cement concrete, M-20 (Nominal Mix) (using 20 mm graded crushed stone aggregate) in beams, cantilevers, bressummers, lintels over 1.5 mtr span complete, all as specified and directed.
Use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete, all as specified and directed.
M&L for MS TMT bars, 10 mm dia and over, cut to length, bent to shape required, including crancking, bending spirally for hooping for columns ,hooking ends & binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete, all as specified and directed.
M&L for MS TMT bars, 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, or securing with clips etc complete, all as specified and directed.
M&L for MS TMT bars, 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete, all as specified and directed.
M&L for RCC M-20, type A1 (Nominal mix) (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete, all as specified and directed.
M&L for RCC M-20, type A0 (Nominal Mix) (using 12.50 mm graded crushed stone aggregate) in chajjas complete, all as specified and directed.
Use & waste of formwork to chullah hoods, chajjas, troughs and similar items including edges complete, all as specified and directed.
Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) complete, all as specified and directed.
M&L for 18/19 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete, all as specified and directed.
M&L for cement concrete, type C-1, 1:3:6 (using 20mm graded crushed stone aggregate) as in hold fast and filling of pressed steel chowkat etc complete, all as specified and directed.
M&L for cement concrete, type B-0, 1:2:4 (using 12.50 mm graded crushed stone aggregate) as in copings, chajja kerbs, roof padding/staging of water tank, copping of pole etc. including necessary fromwork, weathering, slightly rounded or chamfered angles and throating complete, all as specified and directed.
M&L for 40 mm thick cement concrete, type B-0, 1:2:4 (using 12.50 mm crushed stone aggregate) admixed with and includinh Admixture Conplast WL extra (Liquid Proofing Compound) of make Fosroc or equivalent brand of any manufacturer @ 125 ml/50 Kg bag of cement and virgin Polyster Triangular Fiber (Recron) make Reliance or equivalent brand of other manufacturer @ 125 mg/50 Kg bag of cement as in padding over roof and finished even and smooth without using extra cement under the guidance of authorized applicator of manufacturer complete all as specified and directed complete.
S&F in repairs mild steel helical door spring, 300 mm long, ordinary rat tail type, including roaller & roller plate complete fixed with screws to wooden frames or with welding to steel frames complete, all as specified and directed.
M&L for providing 20 mm thick cement plaster in cement mortar 1:3 mixed with Pidi Proof LW or Dr Fixit @ 200 ml per 50kg of cement and finished even and smooth surface without using extra cement as in sunken floor treatment etc complete all as specified and directed. NOTE : WPC shall measured and paid saperately under relevent item.
M&L for cement concrete, type E-2, 1:5:10 (using 40 mm graded stone aggregates) as in sunken portion of WC complete, all as specified and directed.
Cutting holes into or through brick masonry walls built in cement mortar and making good in cement mortar (1:3) or cement concrete, type B-1, 1:2:4 as required superficial area exceeding 150 sq.cm and not exceeding 400 sq.cm complete, all as specified and directed.
S&F in repairs 25 mm bore stainless steel derocative curtain rod with wood fineshes, including 2 Nos brackets and 2 Nos fiunnlel caps etc. Complete, all as specified and directed.
M&L for preparing new plastered surface of walls and applying two coats of distemper-oil emulsion, white or any tint over one coat of primer over one coat of wall care putty complete, all as specified and directed.
M&L for complete removal of existing treatment of wall and applying two coats of distemper-oil emulsion, white or any tint over one coat of primer over one coat of wall care putty complete, all as specified and directed.
M&L for preparing newely plastered surface of wall and applying finishing walls with acrylic smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 Sq.m over and including priming coat of exterior primer applied @ 2.20 kg/10 Sq.m) complete, all as specified and directed.
M&L for preparing old plastered wall surface and applying finishing walls with acrylic smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 Sq.m over and including priming coat of exterior primer applied @ 2.20 kg/10 Sq.m) complete, all as specified and directed.
M&L for preparing new plastered ceiling surface and applying two coats of white wash complete, all as specified and directed.
M&L for preparing new wooden surface of any description, not other wise described, over 10 cm width or girth and applying two coats of synthetic enamel paint, over one coat of pink primer complete, all as specified and directed.
M&L for preparing of old painted surfaces of wood & wood based surface of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete, all as specified and directed.
M&L for preparation of new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and appling with two coats of synthetic enamel paint, over one coat of red oxide primer complete, all as specified and directed.
M&L for preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described, and applying one coat of synthetic enamel paint complete, all as specified and as directed.
Supply only polyester traingular fibres as secondary re-inforcement in all type of concrete and morter complete, all as specified and as directed.
M&L for providing and injecting chemical emulsion emulsion for Post Constructional Antitrmite Treatment, along external wall where the apron is not provided, using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surfacer of the sub-structure to a depth of 300 mm including excavating channel along the wall and rodding etc complete, all as specified and directed.
M&L for providing and injecting chemical emulsion emulsion for Post Constructional Antitrmite Treatment, along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 liters per linear metre including drilling and plugging holes etc in apron complete, all as specified and directed.
M&L for providing and injecting chemical emulsion emulsion for Post Constructional Antitrmite Treatment, treatment of soil under existing floors using emulsion @ one litre per hole, 300mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete, all as specified and directed.
Cutting chases, pinning in making good to facing where required in brick wall and pointing in cement mortar (1:3) to ends and edges of landing, steps, cills, sunshade, shelves, lintel, etc. and cutting chases for concealed water tubing or concealed conduit wiring etc,and making good with the adjoining surfaces, cutting not exc 10 cm girth, complete all as specified and directed.
Making good under cills, over arches, lintel and bresummers, including all pinning when nessesary with using cement mortar (1:6) complete, all as specified and directed.
Removing & hacking of existing concrete carefully by low impact high frequency hammer or by manual chipping without damaging the existing concrete or control sand blasting including cleaning the surfaces by air jet etc. complete all as specified and directed. (NOTE : Mode of measurement, per Sq.mt of breaking area of concrete)
Cleaning of rusted metal (iron base) apply reebaklens RR with brush for complete wetting of rusted metal surface and allowed to react it for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal / steel for about 5-7 days. Before applying protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth complete, all as specified and directed.
Providing and applying two coats of Nitozinc Primer a two component epoxy zinc rich primer or equilvalent product on the properly cleaned and prepared steel bars after the required chipping and cleaning of the concrete surface as per the manufacture's specification complete all as specified and directed.
Drilling holes as per specififed depth of the surface, fix the PVC and fix it with fosroc renderoc plug, rapid setting cement based plugging mortar. Injecting cement slurry admix with Fosroc Cebex 100 or equivalent make, Plasticised expanding grout admixture @ 0.225 Kg per bag of cement and Fosroc Nitobond SBR Latex or equivalent make, @ 5 Lites/50 Kg cement, through the prefixed nozzles under pressure using suitable grout pump to fill all possible pores complete, all as specified and directed.
Identify and opening the cracks and construction joints, honeycomb areas, shall be chased open into 'U' groove shape and sealed with high strength, fiber based cementitious mortar, Fosroc Renderoc SP-40 or equivalent make. Providing and fixing 6-8 mm dia nozzle along the joints and honeycomb areas after proper surface preparation. The injection of Conbextra EP-10 or equivalent make, through the nozzle till the refusal of the grouting materials complete, all as specified and directed.
Supply and apply concrete surface with single component, fibre reinforced shrinkage compensated, polymer modified structural grade repair mortar like Fosroc Renderoc SP-40 or equivalent make of 40 mm thickness. The repair mortar should have a compressive strength 45 N/mm² flexture strength 7 N/mm² and tensile strength 2.5 N/mm² at 28 days complete, all as specified and directed.
Providing supplying, transporting materials, drilling holes by rotary hammer drill, dust removing, batchnig mixing of resin and harderner, inserting & anchoring rebars of specified dia in existing concrete surfaces using polyester resin based anchoring grout like Fosroc Lokfix E-55 or equivalent make and necessary re-baring of reinforcement steel upto 200 mm depth (cost of the reinforcement will be charged extra) complete, all as specified and directed.
Providing and applying structural grade long pot life epoxy bond coat of Nitobond EP Std or equivalent makeprior to building up of section with any type or mortar/concrete to ensure bond between old concrete & new concrete by brush application as per the manufacturer's specification. (Mode of measurement per sqm of application of concrete surface) complete, all as specified and directed.
Providing and laying micro concrete up to the required thickness (Av. 60 mm) on the designated area to the prepared slurry tight shutteing with proper shear conector and bonding agent where ever necessary, The fluid micro-concrete repair material shall be single component, cement based, Renderoc RG or equivalent make, Micro-concrete to which only the site-addition of clean water (and approved graded coarse aggregates where specified) shall be premitted. The micro concrete shall contain no metallic aggregateds, or chlorides and shall be shrinkage compensated in the plastic state. The micro concrete in the flow able consistency should achieve a compressive strength of 50 N/mm² after 28 days at 30°C as per BS 4551-80. The unrestrained expansion shall be between 1-4% as per ASTM C827-1987. Again as per BS 4551-80 the flexural strength shall not be less than 5 N/mm² after 28 day. The micro concrete shall have a co-efficient of thermal expansion 10-12 x 10-6°C and thermal conductivity 1.5 W/m°C the mixed density of micro concrete shall exceed 2100-2200 Kg/M³ at 27°C complete, all as specified and directed.
Providing, erecting, fixing in position waterproof shuttering by plywood/ MS sheet 2.5 to 3.00 mm thick. To be fixed with required size of single frame who can bear the pressure load of concrete during pouring at all location of all shapes with chamfer, splays, key wedges, props, bracings, nails, brackets etc. complete including providing erecting & removing of pipe scaffording at any required height confirming to relevant IS codes, deshuttering the same after specified period without damaging the concrete work complete, all as specified and directed.
Proping and supporting : The structutal members and it's adjoining areas with steel props (Adjustable of as required), bracing, steel/timber runners etc. to relive the structural member of the required load coming over it as per the pattern given by the Contractor or approved by Engr.-in-Charge complete, all as specified and directed.
Providing and fixing double scaffolding system (cuplock type) on the exterior side, up to triple storey height made with 40 mm dia MS tube 1.5 mtr center to center. Horizontal and vertical tubes joining with cup & lock system with MS tubes challies, MS clamps and MS staircase system in-teh scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, renners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete all as per directions and aproval of Engr.-in-Charge. The elevational area of the scaffolding shall be measured for.
Soil Grouting : In this process the penetrobility of high volume fly ash, cement prepared with plasticizer into soil through permeaton grouting. Class-'C' fly-ash was used due to it's pozzolanic activity and fineness. Fly ash-cement grouts have relatively constant and low viscosity values for a reasonoble period after preparation. Exhibit limited or negligible bleed capacity and set and develop satisfactory strength within a relatively short period. Grouting of soil is need for improving the physical and and mechanical properties of soil. Unconfined compressive. (NOTE : All items of stuctural repair and roof treatment shall be carried out through authorised aplicator as appproved.)
Application of waterproofing Coating : Providing and applying Fostoc Brushbond Roof Guard or equivalent make, a single component High build fibre Reinforced Acrylic Waterproofing render for roofing system to be applied by brush, at three coats at minimum dry film thickness of 1 mm, which should cure by reaction with atmospheric moisture to give a tough elastomeric waterproof membrane complete, all as specified and directed. Solid Content : 70 %. Tensile strength ASTM D 412 : 1.10 Mpa. Elongation ASTM D12 : 100 %. Resistance to ageing due to : 10:00 Hour. UV radiation ASTM D4587 E : No Change. Rapid Chloride Penetration ASTM c 1202 : Very low. Pull off adhesion ASTM D541 : 0.92 Mpa. Resistance to Algae growth ASTM D 5589-97 : Passes, Zero rating. Permeability (mm) (BSEN 12390 Part-8 : 5.0 Water vapour transmission (ASTM E 96) : 6.0g/m² h (NOTE : Application of waterfroof coating will be done by authorised aplicator, using matiral of approval make.)
Surface Preparation : Surface to be free from frost, surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish for applicaion of water proof coating prime the surface with water. Including removal of all existing treatment, bituminious membrane, tarfelt, screed concrete etc. from RCC slab complete, all as specified and directed.
Coving Treatment : M&L for coving (50 X 50mm) to be done at all junctions with Nitobond SBR latex or equivalent make to be mixed with cement complete, all as specified and directed.
Cracks & Honeycomb Treatment by Injection Grouting : Identify the cracks and joints, shall be chased open into 'U' groove shape. Prepared suitable surface as require to apply the mortar. Apply a bond coat of Fosroc Nitobond SBR Latex or equivalent make and sealed with Shrinkage controlled, polymer modified, fiber reinforced cementitious repair mortar, Fosroc Renderoc SP-40 or equivalent make. Fixing PVC nozzle, injection grouting to be done with cement slurry admixed with expanding grout admixture Cebex 100 or equivalent make to be mixed @ 225 gm per bag of cement complete, all as specified and directed. (NOTE : Application of will be done by authorised aplicator, using matiral of approval make.)
Bore Packing : M&L for bore packing to be done at pipe entries by forming proper formwork and filling the gap with non-shrinkable cementitious grout Conbextra GP-2 or equivalent make and sealed with epoxy/polyester sealant complete, all as specified and directed. (NOTE : Application of will be done by authorised aplicator, using matiral of approval make.)
PATH : - M&L for 75 mm thick PCC flooing, type D-2, 1:4:8 (using 40 mm graded crushed stone aggregate) as in sub base complete, all as specified and directed.
S&F 60 mm thick, M-35 Grade, Machine pressed, precast concrete, interlocking paver block, with grey cement and pigment, any shape and size, confirming to IS 15658-2006 complete, all as specified and directed.
M&L for sand filling as in paver block path including watering and consolidation complete, all as specified and directed.
M&L for providing Pre-cast cement concrete solid block, type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) and block masonry as in kerb stone edging exc. 10 cm. including chambers watering throathings and setting in cement mortar (1:4) complete, all as specified and directed.
M&L for applying two or more coats of 100 % premium Acylic emulsion paint having VOC less than 50 gm/litre and UV resistant as per IS 154 B9 : 2004, Alkali, fungas and dirt restistant exterior paint of required shed (Company Depot Tinted) with silicon additives @1.43 litre/10 Sq.m over and including primer coat of exterior primer applied @0.90 litre/10 Sq.m over new surfaces complete, all as specified and directed.
SEWAGE DISPOSAL : - Demolition and breaking up 150 mm bore drain pipes (Salt Glazed ware, AC or RCC) set in cement motar complete, all as specified and directed.
M&L for pre-cast cement concrete, type B-1, 1:2:4 (using 20 mm graded crushed stone aggrgates) set in cement morter (1:4) as in landing, cover slab (for manholes etc), chajja, water trough, and similar article with plain faces, including form work etc. complete, all as specified and directed.
M&L for plain cement concrete, type D-2, 1:4:8, (using 40 mm graded crushed stone aggregate) as in foundations and mass concrete complete, all as specified and directed.
M&L for 150 mm internal dia of double wall corrugated HDPE pipe, ISI marked, Class SN-8 (with CM/L No) with and including all fittings and jointing materials, laid in trenches and jointed complete, all as specified and as directed.
M&L for cement concrete, type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in surface channels and drains complete, all as specified and directed.
M&L for cement concrete, type C-2, 1:3:6, (using 40 mm graded crushed stone aggregate) for bed to 150 mm bore of pipe drain pipes, including packing under, and haunching against the sides of pipes after they are laid tested complete, all as specified and as directed.
M&L for cement concrete, type C-2, 1:3:6. (using 40 mm graded crushed stone aggregate) as in surface channels, drains and making good to road/path complete, all as specified and directed.
EXTERNAL WATER SUPPLY : - M&L for drilling and tapping 40/50 mm bore (as required) CI/GI water mains (in position) for branch connections complete, all as specified and directed.
S&F 50 mm bore of pipe gun-metal globe or gate valves, with iron wheel head, screwed both end for iron pipe complete, all as specified and directed.
S&F 40 mm bore of pipe gun-metal globe or gate valves, with iron wheel head, screwed both end for iron pipe complete, all as specified and directed.
Supply and laying 50 mm bore galvanised steel (GI) water tubing, medium grade, galvanised with all fittings and fixtures laid in trenches complete, all as specified and as directed.
Supply and laying 40 mm bore galvanised steel (GI) water tubing, medium grade, galvanised with all fittings and fixtures laid in trenches complete, all as specified and as directed.
Supply and laying 25 mm bore galvanised steel (GI) water tubing, medium grade, galvanised with all fittings and fixtures laid in trenches complete, all as specified and as directed.
Supply and laying 20 mm bore galvanised steel (GI) water tubing, medium grade, galvanised with all fittings and fixtures laid in trenches complete, all as specified and as directed.
S&F 25 mm bore of pipe stop valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union complete, all as specified and directed.
INTERNAL ELECTRIFICATION :- Taking down copper/aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets light fitting, sunken box, switch board etc. for taking credit removing from site including making good to disturbed surfaces as per existing specification complete, all as specified and as directed.
M&L for concealed point wiring with 1.5 Sq.mm (nominal area) FRLSH PVC insulated, single core, unsheathed, multistranded, copper conductor cables, 1100 Volts grade, including 1.5 Sq mm (nominal area) with FRLSH PVC insulated,single core, unsheathed, multistranded, copper earth continuity conductor, 1100 Volts grade, drawn through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit and accessories fixed to wall/ceiling Including cutting chases in cement mortar (1:3) to making good with the adjoining surfaces and connected to common earth dolly complete, all as specified and as directed. for the followings : - Note : Item Continued as Ser. Item No. 6.02 to Ser. Item No. 6.05.
(a) One light point controlled by two Nos, 2-way switch, 240 Volts.
(b) One light/bell/ceiling fan/exhaust fan point controlled by one, one way switch, 240 Volts.
(c ) One 6 Amp, 3 pin socket outlet, 240 Volts on independent board.
(d) One 6 Amp, 3 pin socket outlet, 240 Volts on the same board with other switches
M&L for concealed point wiring for one 16 Amp, socket outlet, on independent board with 2.5 Sq.mm (nominal area) FRLSH PVC insulated, single core, unsheathed, multistranded, copper conductor cables, 1100 Volts grade, alongwith 2.5 Sq mm (nominal area) with FRLSH PVC insulated,single core, unsheathed, multistranded, copper earth continuity conductor, 1100 Volts grade, drawn through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit and accessories fixed to wall/ceiling Including cutting chases in cement mortar (1:3) to making good with the adjoining surfaces and connected to common earth dolly, including making good to facing and pointing in using cement mortar (1:3) and making good to disturbed surface as per existing specification complete, all as specified and as directed.
S&F Modular Bell Push, 6 Amp, 1 module, complete all as specified and directed.
S&F Modular Switch, 2 way, 6 Amp, 1 module, complete all as specified and directed.
S&F Modular Switch, 1 way, 6 Amp, 1 module, complete all as specified and directed.
S&F Modular Switch, 1 way, 16 Amp, 1 module, complete all as specified and directed.
S&F Modular Socket, 6 Amp, 2/3 pin combined, 2 module, complete all as specified and directed.
S&F Modular Socket 6/16 Amp, 2/3 pin combined, 2 module, complete all as specified and directed.
S&F Modular fan regulator, step type (five steps), 120 Watt, 2 module, complete all as specified and directed.
S&F Modular Blank plate, 1 module, complete all as specified and directed.
S&F Modular type, white cover plate with frame, 1 module, complete all as specified and directed.
S&F Modular type, white cover plate with frame, 2 module, complete all as specified and directed.
S&F Modular type, white cover plate with frame, 3 module, complete all as specified and directed.
S&F Modular type, white cover plate with frame, 4 module, complete all as specified and directed.
S&F Modular type, white cover plate with frame, 6 module, complete all as specified and directed.
S&F Modular type, Metal Flush box, 1/2 module, complete all as specified and directed.
S&F Modular type, Metal Flush box, 3 module, complete all as specified and directed.
S&F Modular type, Metal Flush box, 4 module, complete all as specified and directed.
S&F Modular type, Metal Flush box, 6 module, complete all as specified and directed.
S&F Bell, AC, 230 Volts, single pole, Ding Dong Type, complete all as specified and directed.
S&F Ceiling rose, 3 phase, PVC/ polycarbonate, isolated body complete, all as specified and directed.
S&F 1x18 Walt, 4 feet long, LED Tube light luminaries, (Cool day / Warm White) with high performance LED with driver, holder, including LED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete, all as specified and directed.
S&F 1x10 Walt, 2 feet long, LED Tube light luminaries, (Cool day/Warm White) with high performance LED with driver, holder, including LED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete, all as specified and directed.
S&F CITY 1 wall light fixture, made up of Polycarbonate suitable for 3 Walt LED lamp (B-22) include 9 Walt LED bulb etc. complete with all accessories, internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete, all as specified and directed.
S&F Lamp Holder, PVC/Polycarbonate type with back plate suitable for B-22 lamp including 9 Watt LED bulb complete, all as specified and directed.
S&F 1x10 Walt LED bulk head luminaries, IP-65, including LED light driver holder, connecting up with three core flexible copper conductor cable with suitable size of 230 Volts, 50-Hz, complete, all as specified and directed.
S&F 25 Watt LED post top light including all accessories as suitable complete, all as specified and directed.
S&F building security 1X25 Walt LED light luminaire fitting, including connection from ceiling rose with 1.5 Sq.mm PVC insulated stranded copper conductor (FRLS) cable including bracket made of 25 mm bore GI pipe, medium grade, 1.0 mtr long, bent to shape, consisting for mountaning with 300 mm long, mild steel clamps, of (25x3) mm size FI of required shape, (02 Nos per GI brackets) fitted with 4 Nos mild steel bolts, nuts and washer of suitable size complete, including painted with two coats of synthetic enamel paint over one coat of red oxide primer to the expose surface complete, all as specified and directed.
S&F electric water heater, storage type steel body, with copper inner tank and heating element upto 2 KW capacity, 25 Litre, BEE 5 star rated, complete with all accessories such as safety valve, thermostat, non return valve, connection piece etc. including writing MES No. to the body of water heater complete, all as specified and directed.
S&F sheet metal enclosure SPN with a two pin and earth plug and socket complete with one double pole MCB 14/25 Amp, 240 Volts, 10 KA complete, all as specified and directed.
S&F 1200 mm sweep ceiling fans, 230 Volts, 50 Hz, complete with three blade, down rod, accessories with squirrel cage induction motor, including writing MES No. to the body of celing fan complete, all as specified and directed.
S&F 250 mm sweep exhaust fan, 1200 RPM, 230 Volts, 50 Hz, copper winding, made of sturdy engineering plastic complete with louvers shutter, including writing MES No. to the body of exhaust fan, complete all as specified and directed.
S&F 300 mm sweep exhaust fan, AC, single phase, 230 Volts, 50 Hz, with steel body blades and frame and louvers including writing MES No. to the body of exhaust fan, complete all as specified and directed.
Taking down unserviceable DB/control box any type, any size including MCBs including making good to disturbed surface as per existing specification complete, all as specified and directed.
S&F sheet metal enclosure for MCB DB, double door, TPN, 4 way, 415 Volts, suitable for mountaining MCBs, including 415 Amp rated tinned copper common bus bar at incoming end complete, all as specified and directed.
S&F sheet metal enclosure for MCB DB, double door, SPN, 8 way, 240 Volts, suitable for mountaining MCBs, including 200 Amp rated tinned copper common bus bar at incoming end complete, all as specified and directed.
S&F TPN, 415 Volts, 40-100 Amps, 'C' series, breaking capacity 10 KA, with connection testing and commissioning complete, all as specified and directed.
S&F MCB SPN, ‘C’ series, 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, with connection testing and commissioning complete, all as specified and directed.
S&F MCB SP, 'C' series, 6 to 32 Amps, breaking capacity 10 KA with connection testing and commissioning complete, all as specified and directed.
Taking down unsurviceable submain wiring any size/type on wooden batten/conduit/casing capping, including making good to disturbed surface as per existing specification complete, all as specified and directed.
M&L for concealed sub main wiring with two (02) run of 6.0 Sq.mm (nominal area) FRLSH PVC insulated, single core, unsheathed, multistranded, copper conductor cables, 1100 Volts grade, alongwith one (01) run of 6.0 Sq.mm (nominal area) FRLSH PVC insulated, single core, unsheathed, multistranded, copper earth continuity conductor, 1100 Volts grade, drawn through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit and accessories fixed to wall/ceiling Including cutting chases in cement mortar (1:3) to making good with the adjoining surfaces and connected to common earth dolly complete, all as specified and directed. Note : Two (02) runs of 6.0 Sq.mm main copper conductor cable, one (01) run of 6.0 Sq.mm copper earth continuity conduit and one run of PVC concealed conduit shall measured and paid as one unit length are included in the quoted rate.
M&L for concealed sub main wiring with two (02) run of 4.0 Sq.mm (nominal area) FRLSH PVC insulated, single core, unsheathed, multistranded, copper conductor cables, 1100 Volts grade, alongwith one (01) run of 4.0 Sq mm (nominal area) FRLSH PVC insulated, single core, unsheathed, multistranded, copper earth continuity conductor, 1100 Volts grade, drawn through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit and accessories fixed to wall/ceiling Including cutting chases in cement mortar (1:3) to making good with the adjoining surfaces and connected to common earth dolly complete, all as specified and directed. Note : Two (02) runs of 4.0 Sq.mm main copper conductor cable, one (01) run of 4.0 Sq.mm copper earth continuity conduit and one (01) run of PVC concealed conduit shall measured and paid as one unit length are included in the quoted rate.
Taking out unserviceable/damaged/faulty cable of any size and type along with unserviceable brick for cable protection from trench/pole complete, all as specified and directed.
Supply laying & testing 25 Sq.mm cross sectional area, 3.5 core, XLPE insulated, armoured, heavy duty, electric power cable with aluminium conductor, 1100 Volts grade, laid in trench/pole/on wall complete, all as specified and directed. (Note : Excavation shall be measured and paid under respective items of Earth Work.)
M&L for sand cushioning for protection of underground cable, consolidated and compacted with clean dry sand complete, all as specified and directed. (Note : Punned depth shall be measured and paid.)
Supply and laying well burnt, 'old size' sub class, 'B' bricks, laid flat in trenches for cable protection complete, all as specified and directed. (Note : Bricks shall be laid flat and perpendicular to the length of cable.)
M&L for horizontal boring under the road, below 1 mtr from the road surface and dia of hole not exceeding 100 mm without damaging the existing road, getting out and disposal of soil to a distance not exceeding 50 mtr from the site of work complete, all as specified and directed.
M&L for 40 mm bore, galvanised steel (GI) water tubing, light grade with all necessary fittings, laid in trenches/floor, fixed to wall/pole/under road etc. for cable protection complete, all as specified and directed.
Dismentallaing old steel pole/struts, any size including demolituon of concrete foundation and S&F steel tubler swaged pole, with cast iron base plate, finial tapper plug, bolts, nuts and screws type 410 SP-31 (8.5 M/9 M long) including two coats of aluminium paints over one coat of red oxide primer on external exposed surfaces and two coats of black bituminous paint on portion embedded in concrete in internal surfaces of pole including writing MES No. to the body of pole complete, all as specified and directed.
M&L for PCC, type C-2, 1:3:6, (using 40 mm graded crushed stone aggregates) as in foundation of poles filling and mass concrete complete, all as specified and directed. (Note : PCC copping of pole shall be measured and paid under relevant B/R portion.)
S&F street light bracket made of 40 mm bore GI pipe, medium grade, 1.50 mtr long, bent to shape consisting for mountaning with 300 mm long, mild steel clamps, of (25x4) mm size FI of required shape, (02 Nos per GI brackets) fitted with 4 Nos mild steel bolts, nuts and washer of suitable size, including painted with two coats of synthetic enamel paint over one coat of red oxide primer to the expose surface complete, all as specified and directed.
S&F in repairs energy saving and environmental friendly long life LED street light fitting made up of pressure die cast aluminium housing with 60 Watt LED luminaires, aerodynamically designed, 240 Volt, with excellent thermal management, inbult tilt angle arrangement with IP-67 including 3 core copper cable size 2.5 Sq.mm from LED to junction box complete, all as specified and directed.
S&F junction box, PVC type loopin, loopout enclosure (250 x 200) mm size, 105 mm depth, consisting of 4 Nos aluminum busbar of (150 x 20 mm) size, 2 mm thick, fixed on porceline support inside, enclosure fixed with pole using mild steel FI clamps (40 x 6) mm size of required shape with bolts, nuts & washers complete, all as specified and directed.
Supply laying and testing 10 Sq.mm cross section area, 2 core, XLPE insulated, armoured, heavy duty, electric power cable with aluminium conductor, 1100 Volts grade, in trenches through pipe/ducts or on pole walls jointing to OH conductor LT panel main switch with aluminium cable, lugs etc.complete all as specified and directed. (Note : Excavation shall be measured and paid under respective items of Earth Work.)
Taking out unserviceable earthing complete and M&L for earthing complete with galvanised iron earth plate electrode (60 x 60) cm size, 6.3 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.50 mtr below normal ground level, connected to galvanised steel lead wire 4 mm dia by means of galvanised nuts, bolts, check nuts and washers of galvanized iron including 4 mm wire mesh funnel, charcoal or coke and common salt, 20 mm bore GI ‘medium grade’ watering pipe, 40 mm bore ‘medium grade’ GI protection pipe, copper lugs, etc. including excavation and earth work in soft/loss soil, as shown in Electrical Plate No.5 of MES SSR Part-I (2009), connected to earthing test point, and testing on complete in all respect complete, all as specified and directed. Note : Irrespective of whatever shown in electric plate, concrete pit shall be PCC, type C-1, 1:3:6 with 50 mm thick pre-cast RCC cover, type B-1, 1:2:4 and reinforced with 8 mm dia MS TMT bar @ 150 mm C/C both way with suitable handle complete, all as specified and as directed.
Taking down, re-fixing and re-connecting serviceable electric meter, any type, at the same site complete, all as specified and directed.
M/S JYOTI SHARMA AND SONS
NEO BUILDERS
M/S TARAN INFRACON
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .