GE AF TA GWALIOR
GE AF TA GWALIOR 474020
REPAIR/MAINT OF RCC CHAJJA, FACIA and WALL AT AF STATION MAHARAJPUR
2020_MES_377509_1
8900/1265/GWL/E8
Open Tender
Civil Works
Item Rate
210 days
GE AF TA GWALIOR
As per tender documents
7 documents required · 7 mandatory
₹500
GE AF TA GWALIOR
₹40,000
7 Nov 2020
15 Sept 2020
19 Oct 2020
15 Sept 2020
13 Oct 2020
30 Sept 2020
60 days
Amount
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for roof and removing the demolished material to a distance exc 500 m but not exceeding 1.5 km and depositing where directed, complete all as specified and directed
Demolition of brick work or stone masonry of any description and in any position built in cement mortar including all quoins, arches pillar etc including disposal of rubbish complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including racking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
Dismantling of asbestos cement (corrugated or semi corrugated etc) sheet / galvalume sheet in roof covering including ridges complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
M & L for repairing of damaged RCC Chajja, fascia, fins, roof projection, ceiling and balcony railing etc at any height upto 12.00 M by rendering 10 to 50mm thick in one or more layers as per site requirement in CM 1:3 incl hacking out old broken/damaged concrete portion, cleaning of old reinforce etc and applying neat cemtnt slurry @ 3 Kg/Sqm complete all as specified and directed. (Note : rate for all scaffolding required for repairing work shall be deemed included in this rate)
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwss complete as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwss complete as specified and directed.
M&L for framed work of angles or tees with web and flanges cut to shape , drilled and counter sunk for screw , including bending and welding angles as necessary , gusset plates, riveting , etc such as purlin, rafters, post,door frame etc confirming to Fe-290 Gde-E-165 complete all as specified and as directed.
M&L for MS work for wind ties in roofs including securing bolts and similar work quality conforming to Fe-290 Gde E-165 complete all as specified and directed.
M & L for 100 mm wide STP flash strip to seal the joints of AC Sheet complete all as specified and as directed
Taking down the existing complete roof treatment (screed plaster, PCC & tarfelt of any description) and removing to a distance exc. 500 m and n.exc. 5 Km from site complete all as specified and directed.
M & L for PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in benching,kerbs and levelling course etc over roof surface complete all as specified and as directed
M&L for 10 mm thick screed bedding over the green concrete surface in cement mortar 1:3 mixed with liquid water proofing compound @ 200ml per bag WPC (liquid type) , surface finished even and smooth without using extra cement all as specified and directed. Note :- Water proofing additive shall be measured and paid separately.
Supply only liquid water proofing compound complete all as specified and directed.
M & L for water proofing treatment of roof with polymeric water proofing membrane consisting of 90 to 100 micron thick central core of HMHDPE film and standard weight 3 Kg/Sqm shall be laid with 100mm side lap/end lap on prepared surfaces as per manufacturers instruction & under strict supervision of manufacturers tenchnical representative with and including of following operations complete all as specified and directed :- (a) Preparation of plastered surface by cleaning of surface to remove dust etc. (b) Applying a priming coat of @ 0.30 Kg/Sq M with Bituminous primer to the prepared roof till the surface is properly impregnated and solvent oil in primer shall be allowed to evaporate completely. (c) Applying hot blown grade bituminen 85/25 @ 1.2 Kg/Sq M over primer. (d) Laying of polymeric water proofing membrane of weight 3 kg/Sq M. (e) Applying a coat of hot blown grade bitumen 85/25 @ 1.2 Kg/Sq M .
M&L for Applying a coat of bituminous aluminium paint @ 100 Gm /Sqm over bituminous surface complete all asspecified and directed..
M&L for brick work with sub class 'B' bricks , straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 complete all as specified and directed
All as per item No 18 here in before but, except brick (using old bricks obtained from demolition in serviceable conditions) complete all as specified and directed
M&L for rendering 15 mm thick on fair faces of brick or concrete surfaces in cement mortor (1:6) and surface finished even and fair complete all as specified and directed.
M&L for 15mm thick rendering on fair face of brick or concrete surfaces in cement mortor (1:4) and surface finished even and fair complete all as specified and directed.
M & L for applying one coats of white wall care putty on newly plastered surface of bldg to prepare surface smooth make the edges sharp & in proper alignment including all rubbing by sandpaper and applying two coats of oil bound distemper on internal wall surfaces complete all as specified and directed.
M&L for two coats of white wash on old plastered or concrete surface including preparation complete all as specified and directed.
M & L for preparation of newly plastered surfaces of wall and applying two coats of external emulsion paint [Make:-'Ace Paint' of M/s Asian Paints or equivalent as approved by GE] white or tinted complete all as specified and directed.) on external surfaces , complete all as specified and directed.
M & L for preparation of old treated surface by complete removal of existing treatment i.e. white wash ,colour wash ,distempering etc. of wall and applying one coats of white wall care putty to make a smooth surface, edges sharp and proper in alignment including all rubbing by sandpaper and applying two coats of oil bound distemper on internal wall surfaces complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall and applying one coat of white wash complete all as specified and directed.
M&L for preparation of old decorated surfaces of ceiling and applying one coat of white wash complete all as specified and directed.
M & L for preparation of old treated surface by complete removal of existing treatment i.e. white wash ,colour wash ,distempering etc. of wall and applying two coats of external emulsion paint [Make:-'Ace Paint' of M/s Asian Paints or equivalent as approved by GE] white or tinted , complete all as specified and directed.
S&F in repair 110 mm bore PVC(SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches ,floor and wall complete all as specfied and directed.
S&F in repair 110mm bore PVC(SWR) bends complete all as specfied and directed.
S&F in repair 200 mm bore PVC(SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches ,floor and wall complete all as specfied and directed.
S&F in repair 200 mm bore PVC(SWR) bends/socket complete all as specfied and directed.
Hacking out old broken glass pane (any thickness, size, quality or description ) from wooden/metal frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads etc complete all as specified and directed
S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in squere not exceeding 0.50 Sqm in each pane complete all as specified and directed.
Demolition of Reinforced cement concrete in beam,stair cases,landing,chajjas and similar suspended work complete all as specified and as directed.
M&L 10mm dia and over Mild steel TMT bar cut to length bent to shape reqd incl cranking bending etc complete & binding with MS wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L 5 mm dia and over upto and including 10mm dia mild steel TMT bar in stirrups, binders, spacers, cut to length bent to shape reqd incl cranking bending etc complete & binding with MS wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed.
M&L, providing Reinfocement cement concrete 1:1.5:3 (using 20mm graded stone aggregate) as in Chajjas complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets/grid complete all as specified and directed
S&F Solid PVC Wall Lining (Panelling) consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification complete all as specified and directed.
M&L 16mm thick Armstrong DUNE RH 99 Ceiling board with approved pattern(Make- Armstrong) 600x600mm size fixed over and including pre powder coated GI frame with suspension system (Grid) comprising of T section 25mmx32.5mmx1.6mm size as main runners and wall angle to placed along the wall at desired level of the False ceiling 4mm dia GI suspender of suitable size and dash fastners to be provided at desired distance and making good the dismantling portion complete all as directed.
GURU KIRTH BUILDERS
JAY PRAKASH SHARMA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .