| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 CrAccepted-AOC | ₹9.1 Cr Quoted ₹9.3 Cr | L1 | Accepted-AOC Being Lowest Bidder |
| 2 | L2₹9.4 Cr+₹10.5 L (1.13%)Rejected-Finance NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹9.4 Cr+₹10.5 L (1.13%) | L2 | Rejected-Finance Other than L1 bidder |
| 3 | L3₹9.7 Cr+₹37.5 L (4.02%)Rejected-Finance | ₹9.7 Cr+₹37.5 L (4.02%) | L3 | Rejected-Finance Other than L1 bidder |
| 4 | L4₹9.8 Cr+₹44.1 L (4.74%)Rejected-Finance | ₹9.8 Cr+₹44.1 L (4.74%) | L4 | Rejected-Finance Other than L1 bidder |
| 5 | L5₹9.8 Cr+₹48.7 L (5.23%)Rejected-Finance | ₹9.8 Cr+₹48.7 L (5.23%) | L5 | Rejected-Finance Other than L1 bidder |
Tender Value
₹8.8 Cr
EMD Value
₹7.7 L
Closing Date
14 Jul 2021, 6:00 pmClosed
CE (AF) SHILLONG ZONE
HQ CE (AF) SHILLONG ZONE, ELEPHANT FALLS CAMP, PO-NONGLYER, SHILLONG-793009
PROVN OF CERTAIN OTM ACCN FOR NEW GESU AT AF STN CHABUA
2021_MES_441947_2
88629/CHAB/E8
Open Tender
Civil Works
Lump-sum
456 days
GE(AF) Chabua
As per NIT
7 documents required · 7 mandatory
₹3,000
GE (AF) CHABUA
₹7.7 L
Yes
17 Sept 2021
22 Jun 2021
20 Jul 2021
22 Jun 2021
14 Jul 2021
7 Jul 2021
22 Jun 2021 - 30 Jun 2021
Amount
SCHEDULE "A" Part - I (BUILDING / STRUCTURE) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.5 signifies this fact only.
Construction of OPS Block building (Control block) complete all as specified and as shown on drawings
Construction of ADM Block building complete all as specified and as shown on drawings
Construction of MT & Power Plant Office/Store building complete all as specified and as shown on drawings
Construction of Unit Store Room building complete all as specified and as shown on drawings
Construction of POL Store building complete all as specified and as shown on drawings
Construction of Guard House complete all as specified and as shown on drawings
Construction of Watch Tower with rest room complete all as specified and as shown on drawings
Construction of Shed for DG Set complete all as specified and as shown on drawings.
Construction of Sub Station building complete all as specified and as shown on drawings.
Construction of Parking Shed 'B' Vehicale including Repair Bay, DI Store and Apron & Assey area complete all as specified and as shown on drawings.
Construction of Parking Shed for four wheeler (Two Nos) complete all as specified and as shown on drawings
Construction of Parking Shed for two wheeler (Twenty Nos) complete all as specified and as shown on drawings
Construction of Parking Shed for two wheeler (Ten Nos) complete all as specified and as shown on drawings
Construction of Ramp for System Vehical / Washing Bay complete all as specified and as shown on drawings
Construction of Fire Points complete all as specified and as shown on drawings
SCHEDULE "A" PART-II (SITE CLEARANDE, EARTH WORK AND EXCAVATION ) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-III (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (ROAD/PATH/CULVERT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-X (SOUND PROOFING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XI (LIGHTNING PROTECTION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XII (ARBORICULTURE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIII (DEMOLITION/DISMANTLING ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XIV (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' F ' signifies this fact only.
SITE CLEARANCE, EARTH WORK AND EXCAVATION. Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level, not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Removing excavated soil to a distance exceeding 50m but not exceeding 250m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Removing excavated soil to a distance exceeding 250m but not exceeding 500m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M& L for bringing approved earth as stipulated in 3.22.6 of SSR (Part-I) from outside MOD land and depositing as directed.
INTERNAL ELECTRIFICATION. S&F LED street light fitting 1 x 45 Watt with new generation energy saving and environmental friendly long life LED , IP 66 protection and impact resistance IK07, made up of pressure pressure die cast aluminium housing with higher power LED as lighting source and less embeded PC cover having TOP opening seperate driver compartment, with heat resistant toughened glass complete with all accessories and connected with three core flexible wire copper conductor cable of suitable size complete all as specified and directed.
S&F surface/wall mounted decorative ultra slim square profile LED lighting fixure with extruded polycarbonate, environment friendly, energy efficient light fitting in CRCA powder coated white, housing with pre wired suitable for single T8 LED tube including one 20 watt LED tube, 1200mm long with integral / in-built driver, having short circuit and surge protection including making connected with two core PVC insulated flexible wire copper conductor cable of suitable size complete all as specified and directed.
S&F flame proof exhaust fan 450 mm sweep, 1400 rpm, 240 volts, heavy duty turbo force with louvers complete with making holes and fixing on wall with 04 Nos fully threaded nuts, bolts and washers, size of bolt 6 inch long and 6mm dia including provision of three core twisted flexible wire copper conductor cable of size 1.5 sqmm from ceiling rose to exhaust fan including connection complete all as specified and directed.
S & F MCBs (B-Curve) SPN 40A, breaking capicity 10 KA, 240 volts complete all as specified and directed.
Material & Labour for factory made sheet metal enclousure double door designed vertical TPN DB 4 Way DB, recessed/flushed in wall complete with 200 Amps rated copper bus bar, neutral link, dinrail, flat iron clamps duly grouted/fixed flush in the wall, suitable for mounting MCCB as incomer and MCB SPN/SP/TPN as outgoing complete all as specified & directed. Note: MCBs shall be measured and paid separately under respective items.
S&F Flame proof weather proof SPN DB 250 Voilts 4 way with 200 Amps rated copper bus bar neutral link, din rail suitable for mounting MCB SPN/SP/TPN as outgoing duly enclosed in case aluminium LM16 alloy enclosure complete with Flame proof cable glands at entry and exit of cables complete all as specified and directed. Note: MCBs shall be measured and paid separately under respective items.
S & F MCCBs DPX3 4 pole 100A, Breaking capacity 16 KA, 415 volts adjustable type complete with cable connection with copper lugs complete all as specified and as directed .
INTERNAL WATER SUPPLY. S&F 15 mm bore angle stop cock brass CP high pressure with capstan head, long shank screwed down complete all as specified and directed.
ROAD/PATH/CULVERT. Material & Labour for 150mm thick GSB (Granular sub-base) grade V as per Morth table 400-I of MORTH, IRC specification spreading in two layers not exceeding 150 mm thick each, watering, ramming/rolling by tandem vibrator roller & transverse gradient and required camber for achive field compaction at least 98% of MDD (Maximum dry density ) determined using modified procter density determination method as per IS code and CBR (Min 20) as per MoRTH complete all as specified and as directed.
Material & Labour for providing 100 mm thick (compacted thickness) wet mix macadam with crushed stone aggregate of specified grading, spread using mechanical sensor paver/ grader as specified rolled and consolidated using 8 to 10 tonne capacity tandom vibratory power roller to required gradient and camber to achieve minimum 98% density of MDD determined using modified procter density determination method as per IS code and as per MoRTH clause 406 complete all as specified and as directed.
Material & Labour for providing dry lean concrete (DLC), 100 mm thick, compressive strength not less than 10mpa at 7 days for each consecutive group 05 cubes or individual strength of cube shall not less than 7.5 MPA at 7 days over a prepared sub grade with coarse and fine aggregate conforming to IS-383, Size of aggregate n exc 40 mm (grading and other parameters as per table 600-1 of MORTH, IRC,SP :49 specification), design mix , minimum cement content shall not less than 240kg/Cum mixed in batching plant, transported to site, laid with paver including spreading and compacted by using double drum smooth wheeled 80 to 100 KN static weight vibratory roller including necessary form work finishing etc complete all as specified and as per MoRTH specification 601 complete all as specified and as directed. Note:- (a) No price adjustment shall be applicable if excess quantity of cement content used in the work as approved in the Design Mix exceed 240 kg. (b) The rate quoted shall be inclusive of use and waste of form work for total thickness.
Material & Labour for 400 Micron thick transparent HDPE Polythene film of GRADE-I conforming to IS-10889 as anti-friction layer on the base course of runway work/road work as per specification with specified overlap between adjacent strip and transverse joint etc, complete all as specified and directed. Note: Side lap shall be 150 mm and end lap shall be 300 mm. The rate quoted shall be deemed to include for the laps.
Material & Labour for preparing new conceret surface and painting lines, dashes (continous/uninterrupted arrows, letters,etc n,exceeding 10cm width with two coats of water based road marking paint in white ,golden,yellow, orage or red colour over a coat of primer comlete all using road painting machine complete all as specified and directed.
SEWAGE DISPOSAL Construction of Septic Tank for 50 users complete all as shown on drawings and as specified.
Material & Labour for on site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC (1:4:8) below foundation, vent shaft, conction etc conventional complete for 25 users complete all as specified and directed.
Construction of Soakage Well for 50 users complete all as shown on drawings and as specified.
Construction of Soakage Well for 10 users complete all as shown on drawings and as specified.
EXTERNAL WATER SUPPLY. M&L Construction of brick masonry valve pit of size 600mm x 600mm x 600mm (internal dimensions) with one brick thick wall subclass B bricks in CM (1:6) over 100mm thick PCC 1:4:8 type D-2 (using 40mm graded broken stone aggregate) as in foundation, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in bedding and coping and 10 mm thick cement plaster in CM (1:4) internally and externally upto 10 cm below ground level and providing 50 x 50 x 6 mm angle iron frame all round the fixed point by means of 4 Nos holdfast 150mm long made out of flat iron 40 x 6 mm embedded in PCC block (1:2:4) type B1 (using 20 mm crushed stone aggregate) of size 250 x 200 x150 mm including provision of hinges welded with angle iron frame and MS cover 3.15 mm thick , MS Handle of suitable size welded with MS cover and two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in soft / loose soil complete all as specified and as directed.
M&L for cutting of existing 150 mm GI pipe line & providing connection for 100 mm GI pipe line complete with fittings, all as directed.
Supply and lay pipe ductile Iron, single socketed including specials, Class K-7 100 mm (4") bore complete all as specified and as directed.
EXTERNAL ELECTRIC SUPPLY. M & L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including provision of HDPE pipe of 150 mm bore, light grade, suitable for 0.4 mpa working pressure, for protection of UG cable complete all as specified and directed.
M&L for Earthing complete with copper earth plate electrode 600x600x3.15 mm buried directly in ground (Earth pit not less than 2.25m below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to copper strip of size 20x3 mm earth lead by means of bolt, nuts , check nuts and washers of copper upto 7.5m length, earth strip protected by and including 40mm dia GI pipe (light grade ) and connected to main test point or body of pole or lightening arrestor or main controlling switch as directed including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) Type B1 cover slab of size 54x54x5cm reinforced with 8 mm dia TMT bars @ 100 mm C/C both ways with one handle for lifting made out of 10mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm bore GI Pipe (medium Grade ) for watering, charcoal and salt in alternate layers of 15 cm (Compacted thickness ) in any type of soil and disposal of spoil to a distance n.exc 50m and necessary testing complete all as shown in Electrical Plate No3 of SSR part -1 all as specified and directed.
M&L for Earthing complete with galvanised Iron earth plate electrode 600x600x6 mm buried directly in ground (Earth pit not less than 2.25m below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI earth strip of size 32x6 mm earth lead by means of bolt, nuts, check nuts and washers of galvanised iron or steel upto 7.5m length, earth strip protected by and including 40 mm dia GI pipe (light grade) and connected to main test point or body of pole/panel or lightning arrestor of main controlling switch as directed including concrete pit in PCC (1:3:6) type C1, Precast RCC (1:2:4) Type B1 cover slab of size 54x54x5 cm reinforced with 8mm dia TMT bars @100 mm /C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh,20mm bore GI pipe (medium Grade) for watering, charcoal and salt in alternate layers of 15cm (Compacted Thickness)around the earth electrode including necessary excavation, earth work in any type of soil and disposal of spoil to a distance n.exc 50 m and necessary testing complete all as shown in Electrical Plate No 3 of SSR Part-1 all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-3 SSR Part -1 2009 connected to earthing test point including earth wire protection pipe of dia 15 mm (medium grage), excavation and earth work, disposal of surplus spoil, provn of RCC cover 50 mm thick and PCC (1:3:6) type C-2 concrete pit and with suitable handle funnel with watering pipe 20 mm bore (light grade) testing on completion complete all as specified and directed.
M & L for maintenance free chemical earthing system complete with 03 (three) nos copper bonded rods, 17.2 mm dia 3000 mm long electrode buried at suitable distance apart directly in ground, to bore holes of 120 mm dia vertically to a depth not less than 3.60 mtr deep below ground level with top edge of earth electrode at a depth not less than 100 mm below normal ground level, provision of clamps or brazed or both for each copper bonded rods made of cupper and copper strip of size 20 x 3.15 mm & strip connection on the top of the electrode and copper strip of size 20 x 3.15 mm for inter connection of 03 nos copper bonded rods and laying at least 600 mm below in the ground and further connected to test point terminal block (copper strip and test terminal block shall be measured separately), including back filling of bore holes with advanched earth enhanhencing compound 115 kilogram (minimum) of Make : Erico or equivalent of Macmet/True Power/Ennov for artificial treatment to soil so as to achieve earth resistance below 01 Ohms as specified in para 19.140 of SSR Part-1 (2009), including provision of earthing pit in PCC(1:3:6) type C1 pre-cast cover RCC slab of size 400 x 400 x 50 mm with one handle made out of 8 mm dia round bar, including necessary earth work and three coats of white wash on plastered surface (exposed surfaces) and testing complete all as specified and directed.
Supply, installation, commissioning and testing of main LT panel of size suitable to accomdate mentioned accessories , factory made (CPRI approved) indoor cubical compartmental type double door both side openable with hinged doors & locking arrangement made out of not less than 2 mm thick mild steel CRCA sheet supported and fixed on structural frame of angle iron of size 50 x50 x6mm angle iron frame including earthing stud lebeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 stage process), duly fixed in ground with PCC foundation (1:2:4) type B1 with danger notice plate of 1.6mm thick mild steel sheet, vitrious enamelled (white) with letters figures and conventional skull and bones in signal red colour suitable for 3 phase 4 wire system 500Volts grade with necessary wiring with PVC sheathed strander al conductor of appropriate length size with and including fixing lugs bolts, screws etc complete all as specified and directed. For safety , panel shall be finger touch proof and it should have IP-20 Protection in module door open condition. Busbars shall be made of high conductivity, and high strength Aluminum E91 grade as per IS 5082-1981, of rectangular cross sections better suitable for full load current for phase bus bars and half/ full rated current for neutral bus bar or as per requirement . The busbars shall be supported on non-breakable, non-hygroscopic epoxy resin or glass fiber reinforced polymer insulated supports.The material and the spacing of the Busbar supports should be same as per the type tested assembly (TTA). All bus bars shall be provided in a separate chamber and all connections shall be done by bolting. Panel comprising of the following accessories :-
Serial Item No. 14.30 (Contd....) Incoming : (a) Aluminium busbar of rated capacity 500 Amps cover with PVC insulated sleeves including insulator, nuts, bolts etc incl connection complete - 01 set (b) MCCB with thermal magnetic release of capacity 250 Amps 415V. 4 pole 50Hz, Ics = 100% Icu, breaking capacity 25KA -01 No. (c) Neon indicator lamp with holder (Yellow, Blue,Red)- 01 set (Set of three) (d) Digital VAF meter with suitable CTs - 01 No. Out Going: (a) MCCB 4 pole 415 Volts of breaking capacity of 25 KA of 125Amps with Fixed thermal and fixed magnetic setting-01 No (b) MCCB 4 pole 415 Volts of breaking capacity of 25 KA of 63 Amps with Fixed thermal and fixed magnetic setting-01 No (c) MCCB 4 pole 415 Volts of breaking capacity of 25 KA of 25 Amps with Fixed thermal and fixed magnetic setting-02 Nos. (d) MCB SPN 10 A-01 No
Supply, installation, commissioning and testing of size suitable of FDP NO-01 to accomdate mentioned accessories, factory made (CPRI approved) outdoor cubical compartmental type double door both side openable with hinged doors & locking arrangement made out of not less than 3 mm thick mild steel CRCA sheet supported and fixed on structural frame of angle iron of size 50 x50 x6mm angle iron frame including earthing stud lebeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 stage process), duly fixed in ground with PCC foundation (1:2:4) type B1 with danger notice plate of 1.6mm thick mild steel sheet, vitrious enamelled (white) with letters figures and conventional skull and bones in signal red colour suitable for 3 phase 4 wire system 500Volts grade with necessary wiring with PVC sheathed stranded al conductor of appropriate length size with and including fixing lugs bolts, screws etc complete all as specified and directed. For safety, panel shall be finger touch proof and it should have IP-65 Protection in module door open condition. Busbars shall be made of high conductivity, and high strength Aluminum E91 grade as per IS 5082-1981, of rectangular cross sections better suitable for full load current for phase bus bars and half/ full rated current for neutral bus bar or as per requirement . The busbars shall be supported on non-breakable, non-hygroscopic epoxy resin or glass fiber reinforced polymer insulated supports.The material and the spacing of the Busbar supports should be same as per the type tested assembly (TTA). All bus bars shall be provided in a separate chamber and all connections shall be done by bolting. Panel comprising of the following accessories :-
Serial Item No. 14.32 (Contd....) Incoming : (a) Aluminium busbar of rated capacity 400 Amps cover with PVC insulated sleeves including insulator, nuts, bolts etc incl connection complete - 01 Set (b) MCCB with thermal magnetic release of capacity 100 Amps 415V. 4 pole 50Hz, Ics = 100% Icu, breaking capacity 25 KA -01 No. (c) Neon indicator lamp with holder (Yellow, Blue,Red)- 01 set (Set of three) (d) Digital VAF meter with suitable CTs - 01 No. Out going: (a) MCCB 4 pole 415 Volts of breaking capacity of 25 KA of 40 Amps with Fixed thermal and fixed magnetic setting-02 Nos. (b) MCCB 3 pole 415 Volts of breaking capacity of 25 KA of 16 Amps with Fixed thermal and fixed magnetic setting -01 No.
Supply, Installation, Testing & Commissioning LT FDP NO-2 compartmentalised design of self supporting totally enclosed double door at front, dust and vermin proof of size 1200 mm(Height) x 800 mm(Length) x 600 mm(Width) suitable for 440 Volt 3 phase 4 wire system made out of 3 mm thick CRCA sheet and built upon regid frame work having front and rear hinged doors with neoprence rubber gasket including danger plate, earthing strip point and, ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size of Zinc/Cromium plated and nuts, bolts ;and washers etc. For safety panel shall be outdoor type, finger touch proof and it should have IP 65 protection. The panel shall be synthetic enamelled painted and the control circuit diagram shall be with colour code solid conductor copper 1.5 sqmm cable for easy identification including incomming/outgoing cable holes at the bottom. The Panel shall be emmbeded with 50 x 50 x 6 mm MS Angle Iron frame and 50 cm above the normal ground level complete with PCC foundation (1:2:4 ) type B2 comprising of the following. (a) Copper bus bar 200 amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. Incoming: (b) MCCB 4 pole 415 Volts of breaking capacity of 25 KA of 40 Amps with Fixed thermal and fixed magnetic settings - 01 No. Outgoing: (c) MCCB 4 pole 415 Volts of breaking capacity of 25 KA of 16 Amps with Fixed thermal and fixed magnetic settings -02 (d) MCB SPN 4- 6 A, C-curve, 240 volts - 03 Nos.
Supply, Installation, Testing & Commissioning LT FDP NO-3 compartmentalised design of self supporting totally enclosed double door at front, dust and vermin proof of size 1200 mm(Height) x 800 mm(Length) x 600 mm(Width) suitable for 440 Volt 3 phase 4 wire system made out of 3 mm thick CRCA sheet and built upon rigid frame work having front and rear hinged doors with neoprence rubber gasket including danger plate, earthing strip point and, ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size of Zinc/Cromium plated and nuts, bolts ;and washers etc. For safety panel shall be outdoor type, finger touch proof and it should have IP 65 protection. The panel shall be synthetic enamelled painted and the control circuit diagram shall be with colour code solid conductor copper 1.5 sqmm cable for easy identification including incomming/outgoing cable holes at the bottom. The Panel shall be emmbeded with 50 x 50 x 6 mm MS Angle Iron frame and 50 cm above the normal ground level complete with PCC foundation (1:2:4 ) type B2 comprising of the following. (a) Copper bus bar 200 amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. Incoming: (b) MCCB 4 pole 415 Volts of breaking capacity of 25 KA of 63 Amps with Fixed thermal and fixed magnetic setting - 01 No Outgoing: (c) MCB SPN 10 A, C-curve, 240 volts - 01 No (1 spare). (d) MCB SP 6 A, C-curve, 240 volts - 01 No
Supply ,Installation, Testing & Commissioning LT FDP NO-04 compartmentalised design of self supporting totally enclosed double door at front, dust and vermin proof of size 1200 mm(Height) x 800 mm(Length) x 600 mm(Width) suitable for 440 Volt 3 phase 4 wire system made out of 3 mm thick CRCA sheet and built upon rigid frame work having front and rear hinged doors with neoprence rubber gasket including danger plate, earthing strip point and, ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size of Zinc/Cromium plated and nuts, bolts ;and washers etc. For safety panel shall be outdoor type, finger touch proof and it should have IP 65 protection. The panel shall be synthetic enamelled painted and the control circuit diagram shall be with colour code solid conductor copper 1.5 sqmm cable for easy identification including incomming/outgoing cable holes at the bottom. The Panel shall be emmbeded with 50 x 50 x 6 mm MS Angle Iron frame and 50 cm above the normal ground level complete with PCC foundation (1:2:4 ) type B2 comprising of the following. (a) Copper bus bar 200 amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. Incoming: (b) MCCB 4 pole 415 Volts of breaking capacity of 25 KA of 16 Amps with Fixed thermal and fixed magnetic setting-01 No Outgoing: (c) MCB SPN 10 A, C-curve, 240 volts -01 No(1 spare) (d) MCB SP 6 A, C-curve, 240 volts -01 No (e) Time switches 415 V three Phase of 20 Amp rating with contactor fitted inside steel enclosure - 01 No
Supply, install, testing and commisioning of isolation transformer of capacity 25 KVA complete all as specified and directed.
S&F street light of 75 Watt energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium iP65, suitable for highlighting architectural facade and general purpose lighting complete all as directed specified and directed.
Supply, installation, commissioning and testing Supply and installation of 100 KVA, Silent Diesel Engine driven generating set outdoor type 415 Volts, 3 phase 4 wire, engine as per IS : 10001/10002 and alternator as per IS : 13364 complete with relay panel for automatic starting on mains failure, control panel having meters, sound proof canopy and concrete foundation complete all as specified and directed comprising of following:- (A) a) Fly wheel to suit flexible coupling. b) Flexile coupling with guards. c) Dry type air cleaners with filters. d) Lubricating oil filter, fuel filter, fuel pre filter. e) Anti-vibration pads-quantity and type as recommended by manufacturer. f) Fuel injection system with injector pump, nozzles, governor(electronic) of suitable capacity. g) Electric start equipment. h) Lead acid storage maintenance free battery 2x12V DC of suitable rating with charging alternator, ammeter, as recommended by manufacturers make: As per OEM standard along with copper battery lead and connector. i) Battery rack made out of MS angle iron 40mmX40mmX5mm and 150mm height. j) Standard safety device. k) Daily service fuel tank of suitable capacity for running 12 hrs non-stop on Full Load with mechanical level indicator, detachable strainer, drain cock, fuel outlet, air vent and locking arrangement etc, including fuel pipe connections. l) Exhaust silencer(Residential silencer) with exhaust piping of suitable size brought out side on top of size 76.5 mm dia and complete length of silencer and exhaust piping continuously wrapped with 12 mm dia asbestos rope and suitable anti vibration arrangement around pipe passing through wall.
Serial Item No. 14.39 (Contd....) m) LCD display type control panel as per manufacturer's instructions indicating KWH, KVA, PF, Volts, Amps, Hz, RPM, Hour, Oil pressure, Oil temprature, coolent temprature, fuel level, battery charging ammeter, battery charging lamp and incator lamp (RYB), panel duly prewired and displaying protection and safetys as under:- aa) Protection:- short circuit, overload, over speed, earth fault as standard and reverse power as optional. ab) Safeties:- Auto shut down, visual & audio alarm for low lub oil pressure, high coolant temperature, low fuel level, canopy temperature & radiator water level. (B) Alternator 100 KVA brushless type at 0.8 power factor, self regulated, self excited, screen protected 3 phase with neutral 415 volts 50 HZ, 1500 RPM, as per IS:13364/IS-4722 complete with automatic voltage regulator, having voltage regulation +/-1%, SPDP enclosure including making cable connections, insulation class-H and alternator control panel as supplied by manufacturer. (C) Base frame sturdy, MS fabricated, channel iron base frame for mounting the engine & alternator with anti vibration pads. (D) Acoustics enclosure of suitable size to accommodate DG set 100 KVA, modular construction, fabricated out of 3 mm thick, cold annealed CRCA sheet duly epoxy painted doors to be provided with high quality EDPN gasket, duly epoxy painted. The canopy to be equipped with heavy duty fans of reputed manufacturer for air circulation and cooling the canopy. Rock wool of requisite density per Kg/m3 to be used for insulation. Enclosure to be provided with one light point controlled with one switch for internal lighting. Noise level at one meter to be 75 decibels @ one meter in line as per CPCB norms.
Serial Item No. 14.39 (Contd....) (E) Repair tools to be supplied as under:- (i) Ring spanner set of 10- 01 set. (ii) Screw driver 6",9", 12", 14" - 01 No Each. (iii) Adjustable spanner 12" - 01 No. (iv) Double end spanner set of 10 - 01 No. (v) Cutting pliers insulated and nose plier 10" & 12" - 01 No. (vi) Techo meter - 01 No. (vii) Tool kit box - 01 No. (F) Maint spares to be supplied as under:- (i) All type of filters - 02 Each. (ii) V-Belt - 01 Set NOTE:- (i) The engine of DG set suitably conditioned to suit the climatic condition, so as to give desire outputs including and testing up to 10% over load. (ii) Foundation of the DG set (PCC/RCC) will be provided by the contractor and will be made as per the manufacturer instruction. Cost of foundation is deemed to be included in the rate of this item. (iii) The items required for testing of DG set e.g. fuel, tripod, tools, water tank etc and panel as below shall be provided by the contractor and the rate of which is deemed to be included in the rate of item. (iv) Testing of DG set will be carried out as specified.
S&F Cable Junction Box 210X155X92mm in size, made out of thermoplastic sheet having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 - 2 nos) fixed on poles with flat aluminium clamps of size 25x3mm, nuts, bolts, washers etc. complete all as specified and as directed. Make : Cat No. KF-1616G of HENSEL or equivalent model in SPELSBERG/RITTAL.
S&F rubber mat of size 1000mm x 2000mm x 19mm thick suitable for 11KV system as per IS 15652:2006 complete all as specified and as directed.
Supply only rubber electric hand gloves suitable for 11 KV system as per IS 4770 complete all as directed.
REFRIGERATION AND AC. Supply and installation high wall electrically driven single phase split AC unit indoor/outdoor complete with cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 302 of 1.5TR capacity complete all as specified and directed.
Supply and installation high wall electrically driven single phase split AC unit indoor/outdoor complete with cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 302 of 2TR capacity complete all as specified and directed.
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type wall mounted type designed for input variation between 170V to 260V with output voltage stabilized at 230 V with accuracy of +/- 2.5% and of capacity 5.0 KVA, 12A complete all as specified and directed.
Supply, installation and commissioning of water cooler storage type with fully stainless steel, electric driven 230 V 50 Hz single phase supply com PUF insulation, adjustable cold water thermostat, auto cut facility, overload protection, stainless steel front pane, extended plastic egs, eco-friendly version with Refrigerant-134A, reciprocating type compressor and approximate storage capacity of 80 ltrs and nominal cooling capacity of 40 ltrs per hour all as specified and as directed.
ARBORICULTURE Supply and planting of Morpankhi Tree with Height 3 to 4 feet including Digging Holes 1.2 m Dia x 1.2 m deep in ordinary Soil and Refilling the same with the excavated earth mixed with manure or Sludge in the ratio 2:1 (2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludge/Cow dung / manure after reduction by 8% flooding with water and removal of Surlus soil etc complete all as specified and directed.
Supply and planting of Christmas Tree with Height 3 to 4 feet including Digging Holes 1.2 m Dia x 1.2 m deep in ordinary Soil and Refilling the same with the excavated earth mixed with manure or Sludge in the ratio 2:1 (2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludge/Cow dung / manure after reduction by 8% flooding with water and removal of Surlus soil etc complete all as specified and directed.
Supply and planting of Ashok Tree with Height 3 to 4 feet including Digging Holes 1.2 m Dia x 1.2 m deep in ordinary Soil and Refilling the same with the excavated earth mixed with manure or Sludge in the ratio 2:1 (2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludge/Cow dung / manure after reduction by 8% flooding with water and removal of Surlus soil) complete all as specified and directed.
Supply and plantation of box tree/golden private hedges plant 10 Nos/Sqm, any description and refilling the same with the excavated earth mixed with manure/Sludge/Cow dung in the ratio 2:1 (2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludge/Cow dung / manure after reduction by 8% flooding with water and removal of Surlus soil) complete all as specified and directed.
Supply and plantation of carpet grass, small size and refilling the same with the excavated earth mixed with manure/Sludge/Cow dung in the ratio 2:1 (2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludge/Cow dung / manure after reduction by 8% flooding with water and removal of Surlus soil) complete all as specified and directed.
S&F single jet hydrodynamic gun sprinkler with oscillating arm having radious of throw 15m to 24.5m and flow of 0.81 - 3.4 Ips at an operative pressure of 1.5 - 6 Kg?Cmsq having 32mm inlet. The body of sprinkler is made of aluminium alloy duly protected in its main parts by bruss stainless steel & techno polymers. The sprinkler is equipt with jet breaker and four different nozzles complete all as specified and directed.
Maintenance of the plants/hedges/grass vide Srl No 14.49 to 14.54 here-in-before by weeding hosing, saucer making once in every month for plants/hedge, once in every 15 days for carpet grass/ country grass/doob grass, Burmuda grass prunng dried branches once in every week, depositing the material at place as directed by Engr-in-Charge and planting the new plants in place of dead plants of same species and height tuning with dods wherever required by replacing the dead patched of grass of any with the same grass as required without extra cost to the department and as directed by the Engr-in-Charge.
SCHEDULE "A" PART-XV (SCHEDULE OF CREDIT) Note :- Amount of Rs. 745600.00 indicated in Tender as Schedule of Credit i.e. Schedule 'A' Part-XV shall be deducted from the total quoted amount of BOQ.
Phoenix Infra
GANGA INFRABUILD PVT LTD
M/s Matadeen Ramchandra Agarwal
AMIT ASSOCIATES
SAWHNEY BUILDWELL LLP
Baka Construction
C R R CONSTRUCTIONS
M/S Shiv Shakti Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .