Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC 2 BHAWANI NAGAR J K ROAD BHOPAL MP | BHOPAL | MADHYA PRADESH | L1 | Accepted-AOC L1 | |
| 2 | L2₹38.4 L+₹9.2 L (31.6%)Rejected-AOC 3 NEW TRIMURTY CO OP HOUSING SOCIETY INGOLE NAGAR WARDHA ROAD NAGPUR 440005 MAHARASTRA | NAGPUR | NAGPUR | MAHARASHTRA | 440005 | L2 | Rejected-AOC L2 | |
| 3 | L3₹46.9 L+₹17.7 L (60.8%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Reject |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
3 Aug 2023, 3:30 pmClosed
CE (EHT-Construction)
Block No.4, Shakti Bhawan, Rampur, Jabalpur
Conducting Various NDT (Non Destructive Tests) and Core Test On Foundations Of EHV Towers/ Structures/Buildings and Tests For Various Building Materials at Different Locations In M.P. i/c Submission Of Test Report
2023_MPPTC_291280_1
672
Open Tender
Civil Works - Buildings
Percentage
365 days
All MP
Please refer tender document
8 documents required · 8 mandatory
₹1,770
₹99,800
Yes
23 Feb 2024
13 Jul 2023
4 Aug 2023
13 Jul 2023
3 Aug 2023
13 Jul 2023
Amount
Conducting the Non Destructive Tests (NDT) on various towers/structures/ foundations, i/c cement concrete Roads, or any other structures constructed in EHV line/substations of MPPTCL ….(a) Ultra sonic Pulse velocity (UPV) Test
Conducting the Non Destructive Tests (NDT) on various towers/structures/ foundations, i/c cement concrete Roads, or any other structures constructed in EHV line/substations of MPPTCL ...(b) Rebound Hammer (RH) Test
Extracting concrete cores from the foundations/ structures of approved size, i/c finishing capping, conditioning & testing, it for compressive Strength of the concrete.
Conducting following test on cement, based on relavent IS codes :-...(i) Standard Consistency Test(As per
Conducting following test on cement, based on relavent IS codes :-..(ii) Initial & Final settig Time
Conducting following test on cement, based on relavent IS codes :-...(iii) Compressive Strenght o(for 2ages)
Conducting following test on cement, based on relavent IS codes :-...(iv)Soundness Test by Le Chatelier Method
Conducting following test on cement, based on relavent IS codes :-...(v) Fineness Test by Blains Air Permiability Method
Conducting following test on Coarse Aggregate, based on relavent IS codes :-...(i) Sieve Analysis
Conducting following test on Coarse Aggregate, based on relavent IS codes :-...(ii)Water absorption Test
Conducting following test on Coarse Aggregate, based on relavent IS codes :-...(iii) Specific Gravity
Conducting following test on Coarse Aggregate, based on relavent IS codes :-..(iv) Aggregate Impact Test
Conducting following test on Coarse Aggregate, based on relavent IS codes :-..(v) Flakiness & Elongation Index
Conducting following test on Fine Aggregate, based on relavent IS codes :-...(i) Sieve Analysis
Conducting following test on Fine Aggregate, based on relavent IS codes :-...(ii) Water absorption Test
Conducting following test on Fine Aggregate, based on relavent IS codes :-...(iii) Specific Gravity
Conducting following test on Fine Aggregate, based on relavent IS codes :-...(iv) Aggregate Impact Test
Conducting following test on Fine Aggregate, based on relavent IS codes :-...(v) Material Finer than 75 micron
Conducting following test on Cement Concrete, based on relavent IS codes :-..(i) Compressive Strenght of Cube (15x15x15 cms)
Conducting following test on Bricks based on relavent IS codes :-..(i) Compressive Strength Test
Conducting following test on Bricks based on relavent IS codes :-...(ii)Water absorption Test
Conducting following test on Bricks based on relavent IS codes :-...(iii) Effloresence
Conducting following test on reinforcement Steel based on relavent IS codes :-..(i) Determination of yield strength, Tensile strength and elongation of steel bar of all diameter with the help of UTM
Conducting following test on reinforcement Steel based on relavent IS codes :-...(ii) Weight per metre
Conducting following test on reinforcement Steel based on relavent IS codes :-..(iii) Bend& rebend Test
Conducting following test on reinforcement Steel based on relavent IS codes :-...(iv) Chemical Test including Carbon, Sulphate, Phosphorous etc.
Conducting following test on Vitrified Tiles, based on relavent IS codes :-..(i) Water Absorption
Conducting following test on Vitrified Tiles, based on relavent IS codes :-..(ii) Modulus of Rupture
Conducting following test on Concrete Paver Block, based on relavent IS codes :-..(i) Water Absorption
Conducting following test on Concrete Paver Block, based on relavent IS codes :-..(ii) Abrassion Resistance Value
Conducting following test on Concrete Paver Block, based on relavent IS codes :-..(iii) Compressive Strength
Transportation of staff & equipments (to & fro)…...(a) Up to 100 KM
Transportation of staff & equipments (to & fro)..(b) More than 100 KM but less than 250 Km
Transportation of staff & equipments (to & fro)..(c) More than 250 KM but les than 500 KM
Transportation of staff & equipments (to & fro)..(d) More than 500 KM
Lodging & boarding of staff. (applicable only in case of 11c & 11d above)
BECQUEREL INDUSTRIES PRIVATE LIMITED
GEOTECH SERVICES PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .