| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.4 LAccepted-AOC SCF 15 HUDA COMPLEX 184 NEW IDC 124001 | ROHTAK | HARYANA | 124001 | ₹45.4 L | L1 | Accepted-AOC AOC |
| 2 | L2₹58.0 LRejected-AOC 143 INDUSTRIAL AREA PHASE 2 PANCHKULA HARYANA | PANCHKULA | PANCHKULA | HARYANA | ₹58.0 L | L2 | Rejected-AOC Reject |
| 3 | Rejected-Technical GAUSHALA MARKET TEHSIL NARNAUL NARNAUL 123001 | NARNAUL | NARNAUL | HARYANA | 123001 | - | - | Rejected-Technical reject due to non responsive |
| Sl No | Description | Qty | Unit | Avon Engineering Company L2 | Highlight Associates and Contractors L1 |
|---|---|---|---|---|---|
| 1.00 | Providing & laying LT Armoured PVC copper cable of size 70 sq. mm, 3 core conforming to IS 7098 -1988 as per approved makes along with required thimbles for necessary connections. | 40 | Mtr. | 8,850 ₹3,54,000 | 4,000 ₹1,60,000 Lowest |
| 2.00 | Providing & laying LT Armoured PVC Armoured copper cable of size 120 sq. mm, 3.5 core with copper thimble, copper bolts & other allied material conforming to IS 7098 -1988 as per approved makes with required specific thimbles for necessary connections. | 54 | Mtr. | 1,750 ₹94,500 Lowest | 7,000 ₹3,78,000 |
| 3.00 | Providing deep complete double side chemical earthing or plate earthing with 2 earth pits on both sides of pump house by boring & lowering 1.5" GI pipe, filling boring with charcoal, copper strips, salt & fixing base plate of chemical earthing, connecting this main earthing through copper strips /wires up to motors & panel confirming to IS- 3043 as per site requirement | 2 | Job | 85,000 ₹1,70,000 | 25,000 ₹50,000 Lowest |
| 4.00 | Providing & laying LT Armoured PVC Armoured Aluminium cable of size 630 sq. mm, 3.5 core with copper thimble, copper bolts & other allied material conforming to IS 7098 -1988 as per approved makes with required specific thimbles for necessary connections. | 100 | Mtr. | 11,000 ₹11,00,000 | 4,500 ₹4,50,000 Lowest |
| 5.00 | Supply Erection commissioning of LTDB Panel of 800 Amp, 3 Phase 50 Hz, Motor Control Centre L.T. Panel with main incomer ACB of 800Amp and 5 no. outgoing feeder with Auto Transformer Starter Air cooled Panel for operating, 3 No. 100 HP Motor and 2 No 50 HP Motor fitted with suitable range ACB, MCCB, Air break Contactors, Micro controller based fault protecting devices/relays, timers and indicators and other allied accessories complete in all respect with a stand of MS Channel/angle having 1 feet height from floor level & as per approved specification of deptt. (as per Annexure-C). The LT Panel should be complete with capacitor bank of 120 KVAR with incomer consist of contactor & MCCB. One No MCCB of 400 Amp to be provided for Capacitor Bank. Each step should consist of contactor & MCCB as per technical specifications approved by I & WR Deptt. Haryana as per Annexure-C | 1 | No. | 40,80,000 ₹40,80,000 | 35,00,000 ₹35,00,000 Lowest |
Tender Value
₹66.8 L
EMD Value
₹1.3 L
Closing Date
15 Jan 2026, 12:00 pmClosed
Executive Engineer
W.S Mechanical Division Jhajjar
Supply Erection Commissioning of LTDB panel of 800 Amp alongwith all others allied accessories at RD 0 of Bishan Link Drain Pump House in Water Services Mechanical Sub Division Beri at Jhajjar.
2026_HRY_495145_5
75-91/17-A dated 06/01/2026
Open Tender
Miscellaneous Goods
Supply
90 days
Jhajjar
as per eligibility criteria
2 documents required · 2 mandatory
₹5,000
₹1.3 L
Yes
13 Apr 2026
6 Jan 2026
15 Jan 2026
6 Jan 2026
15 Jan 2026
6 Jan 2026
Providing & laying LT Armoured PVC copper cable of size 70 sq. mm, 3 core conforming to IS 7098 -1988 as per approved makes along with required thimbles for necessary connections.
Providing & laying LT Armoured PVC Armoured copper cable of size 120 sq. mm, 3.5 core with copper thimble, copper bolts & other allied material conforming to IS 7098 -1988 as per approved makes with required specific thimbles for necessary connections.
Providing deep complete double side chemical earthing or plate earthing with 2 earth pits on both sides of pump house by boring & lowering 1.5" GI pipe, filling boring with charcoal, copper strips, salt & fixing base plate of chemical earthing, connecting this main earthing through copper strips /wires up to motors & panel confirming to IS- 3043 as per site requirement
Providing & laying LT Armoured PVC Armoured Aluminium cable of size 630 sq. mm, 3.5 core with copper thimble, copper bolts & other allied material conforming to IS 7098 -1988 as per approved makes with required specific thimbles for necessary connections.
Supply Erection commissioning of LTDB Panel of 800 Amp, 3 Phase 50 Hz, Motor Control Centre L.T. Panel with main incomer ACB of 800Amp and 5 no. outgoing feeder with Auto Transformer Starter Air cooled Panel for operating, 3 No. 100 HP Motor and 2 No 50 HP Motor fitted with suitable range ACB, MCCB, Air break Contactors, Micro controller based fault protecting devices/relays, timers and indicators and other allied accessories complete in all respect with a stand of MS Channel/angle having 1 feet height from floor level & as per approved specification of deptt. (as per Annexure-C). The LT Panel should be complete with capacitor bank of 120 KVAR with incomer consist of contactor & MCCB. One No MCCB of 400 Amp to be provided for Capacitor Bank. Each step should consist of contactor & MCCB as per technical specifications approved by I & WR Deptt. Haryana as per Annexure-C
stage.html
html • 0.05 MB
technical_573652.pdf
techsummary_573652.pdf
finance_573652.pdf
BOQ Comparative Chart
xlsx
finsummary_573652.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.29 MB
BOQ_573652.xls
BOQ • 0.28 MB
5.pdf
Additional Documents • 3.80 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].