Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹27.8 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹31.5 L+₹26,446 (0.85%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹33.9 L+₹2.7 L (8.69%)Rejected-Finance | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹34.4 L+₹3.2 L (10.3%)Rejected-Finance | L-4 | Rejected-Finance L-4 | |
| 5 | L-5₹35.9 L+₹4.7 L (14.9%)Rejected-Finance | L-5 | Rejected-Finance L-5 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
4 Mar 2024, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
SPECIAL REPAIR TO BOUNDARY WALL AT CERTAIN LOCATION AND OTHER E/M WORKS AT AF STN DADRI IN AOR OF GE (AF) FARIDABAD
2024_MES_640748_1
GE (FBD)/AF-70/2023-2024
Open Tender
Civil Works
Item Rate
180 days
DADRI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹99,000
Yes
8 Apr 2024
5 Feb 2024
6 Mar 2024
5 Feb 2024
4 Mar 2024
19 Feb 2024
5 Feb 2024 - 9 Feb 2024
Amount
Demolition of brick work built in cement mortar of any description complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster from brick or stone masonry or concrete surfaces and hacking for key and scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, chajjas, facias, fins and similar works complete all as specified and directed by Engineer-in-Charge.
Demolition of un-reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:2;4 B0 (using of 12.5 mm graded Stone Aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and chajjas complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) complete all as specified and directed by Engineer-in-Charge.
M&L for 10 mm dia and over TMT bar cut to length bent to shape required including cranking bending spirally for hoping for columns hooking ends binding with MS wire n.exc 0.9mm or with securing clips etc complete all as specified and directed by Engineer-in-Charge.
M&L for 6 to 8 mm dia TMT bar cut to length bent to shape required including cranking bending spirally for hoping for columns hooking ends binding with MS wire n.exc 0.9mm or with securing clips etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick in CM 1:4 on stone masonary or surface other than fair face of brick works etc or similar surfaces etc including with mixing of water proofing liquid as per manufactrer instruction complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint on walls over a coat of alkali resistant priming paint complete all as specified and directed by Engineer-in-Charge.
Supply only integral water proofing liquid ( ISI marked) complete all as specified and directed by Engineer-in-Charge.
M & L brick work with sub class 'B' bricks(old size bricks) straight or curved on plan exc 6 m mean radius built in cm 1:6 with and including weep holes in brick work complete all as specified and directed by Engineer-in-Charge.
M&L for providing cement concrete 1:2:4, type B1, using 20 mm (graded stone aggregates) as in coping complete all as specified and directed by Engineer-in-Charge.
M&L for mild steel work as in nosing to steps including embeding in concrete and screwing etc., posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe 290 Gde E-165 all as specified and directed by Engineer-in-Charge.
S & F Plates (plain or chequered) channels, Fe 410-W(Gde?E- 250) square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed by Engineer-in-Charge.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.5cm and n exc 30cm long dia 16 to 20 mm complete all as specified and directed by Engineer-in-Charge.
Dismantling of GI barbed wire fencing, any type complete all as specified & directed by Engineer-in-charge.
S& F galvanised, 2 strands, steel barbed wire 2.24mm dia barbed with 2 mm dia barbs at 75mm spacings and straining and fixing to standard rails straining bolts including screwing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc complete all as specified and directed by Engineer-in-charge.
All as item No 18 above but in repairs for Restraining & resecuring including making good staples for galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2 mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old steel surface of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint (ordinary tint) complete all as specified and directed by Engineer-in-charge.
M&L for Preparation of new steel surfaces and applying two coats of synthetic enamelled paint over a coat of red oxide zinc chrome complete all as specified and directed by Engineer-in-Charge.
S&F in repair Hot dipped galvanised concertina razer tape coil 900mm dia, spring steel high tensile centre core wire 2.5mm dia having 200-250 gm zink coating , 0-5mm thick razer sheet having 90-120 gm, zink coating & minimum 10mm width (before wraping centre core wire), with GI clip 1.6 mm , complete all as specified and directed by Engineer-in-Charge.
Supply and fix LED Flood light 70 W IP 65 complete all as specified and directed by Engineer-in-Charge.
Supply and fix LED Flood light 120 W IP 65 complete all as specified and directed by Engineer-in-Charge.
Supply and fix LED Security light 45 W IP 65 complete all as specified and directed by Engineer-in-Charge.
S & F cable junction boxes with hinged door fixing complete with suitable aluminium busbar 4 Nos fixed inside the box complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Weather proof flat single core cable of 1.5 sqmm size complete all as specified and directed by Engineer-in-Charge.
S & F GI bracket of 3.0 metre long with proper bend , welding,nut bolt, clamps etc for fixing of flood light for outside tubes,'light grade', galvanised, with all fitting; laid in trenches complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts graded with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts graded with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts graded with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge.
M & L for boring of holes under road pavement, motor hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 40 MPA working pressure complete all as specified and directed by Engineer-in-Charge.
Supply and fixing bus bar chamber 4 way outdoor type with digitalvoltmeter, digital ampere meter , R-Y-B indicating lamps factory made out of CRCA sheet dust & vermin proof, front opening door having locking arrangement totally enclosed weather proof , antirusted powder coated painted including aluminium busbar of 200 Amps rating bus size 45 cm long X 50 mm wide X 15 mm thick, 440 volts , 3 phase 4 wire having suitable gap to connect the cables of size upto 95 sq mm , 3.5 core and bus mounted on suitable type of insulators incl coloured insulating sleeve on each complete with bottom removable gland plates for incoming and outgoing cables, bus chamber mounted on MS angle stand made of MS angle 50mm X 50 mm X 5mm and should having minimum 45 cm gap below bus chamber incl necessary PCC foundation work complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc or for laying of cables/ poles or foundation etc in soft loose soil getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed by Engineer-in-Charge.
Supplying and laying of brick sub class B laid dry in trenches over the cable ad joining each other widthwise for cable protection complete all as specified and directed by Engineer-in-Charge.
Supply & fix exhaust fans metalic body AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified and directed by Engineer-in-Charge.
Supply & fix Air Circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting complete all as specified and directed by Engineer-in-Charge.
S&F Tubes," medium grade', galvanised, with all fitting; laid in trenches bore of 25mm complete all as specified and directed by Engineer-in-Charge.
S&F Tubes, medium grade', galvanised, with all fitting; laid in trenches bore of 20mm complete all as specified and directed by Engineer-in-Charge.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of bore of 25mm complete all as specified and directed by Engineer-in-Charge.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of bore of 20mm complete all as specified and directed by Engineer-in-Charge.
M&L for auguring of holes in true horizontal position under road by means of manual excavation complete all as specified and directed by Engineer-in-Charge.
AARSINFRATECH
MAA BHAWANI CONSTRUCTION
LAXMI BUILDERS
36SHRI RADHEY ASSOCIATES
ng associate
GARG CONSTRUCTION CO
M/S Yamin
NAVEEN KUMAR TYAGI
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .