| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹20.8 L+₹1.1 L (5.61%)Rejected-Finance | L2 | Rejected-Finance Second lowest | |
| 3 | L3₹21.0 L+₹1.3 L (6.57%)Rejected-Finance | L3 | Rejected-Finance Third lowest | |
| 4 | L4₹22.5 L+₹2.8 L (14.4%)Rejected-Finance | L4 | Rejected-Finance Fourth lowest | |
| 5 | L5₹22.6 L+₹2.9 L (14.8%)Rejected-Finance | L5 | Rejected-Finance Fifth lowest |
| Sl No | Description | Qty | Unit | M/S ADITYA CONSTRUCTIONS L3 | RAJENDRA KRISHNA SARAF L1 | M/S MAHADEV M PATIL L5 | M/s PRATAP VIJAYSINGHRAO DESAI L6 | M/s. N D KALING L2 | Sadhana Constructions & suppliers L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down cement plaster including racking out joint hacking for key scrubbing down with water etc., complete all as specified and directed. | 245 | Sqm | 25 ₹6,125 | 60 ₹14,700 | 25 ₹6,125 | 45 ₹11,025 | 5 ₹1,225 Lowest | 50 ₹12,250 |
| 2.00 | M&L for rendering 10 mm thick cement plaster in CM 1:6 for wall finished even & smooth complete all as specified and directed. | 145 | Sqm | 150 ₹21,750 Lowest | 260 ₹37,700 | 160 ₹23,200 | 225 ₹32,625 | 150 ₹21,750 Lowest | 200 ₹29,000 |
| 3.00 | M&L for rendering 15 mm thick cement plaster in CM 1:4 as in external wall & sunken floor finished even & smooth without using extra cement mixed with water prooffing compound complete all all as specified and directed. Note:-Water proofing compound shall be measured and paid separately as "Supply only" under respective item | 100 | Sqm | 200 ₹20,000 | 280 ₹28,000 | 180 ₹18,000 Lowest | 240 ₹24,000 | 180 ₹18,000 Lowest | 210 ₹21,000 |
| 4.00 | Supply only liquid water proofing compound complete all as specified and directed. | 12 | Ltr | 250 ₹3,000 | 50 ₹600 | 100 ₹1,200 | 180 ₹2,160 | 60 ₹720 | 40 ₹480 Lowest |
| 5.00 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed. | 36 | Cum | 200 ₹7,200 | 600 ₹21,600 | 300 ₹10,800 | 720 ₹25,920 | 250 ₹9,000 | 100 ₹3,600 Lowest |
| 6.00 | Demolition of cement concrete (unreinforced) of any description and in any position complete all as specified and directed. | 32 | Cum | 200 ₹6,400 | 600 ₹19,200 | 300 ₹9,600 | 900 ₹28,800 | 250 ₹8,000 | 110 ₹3,520 Lowest |
| 7.00 | M&L for applying first layer of cement slurry at 0.488 kg/ sqm mixed with Acrylic based polymer 'ARMOUR -CRETE' of structural water proofing Pvt Ltd by ratio 1:2 (one Armour Crete : Two cement) or 'POLYCRYL' of Green boro polychem Pvt Ltd by ratio 1:2 (one polycryl : Two cement) or Ready to use PIDIFIN 2k of PIDILITE INDUSTRIES or SHALICRETE-500 of capital steel and chemicals pvt ltd and silica sand by ratio 1:2:2 (Shalicrete : Cement : Silica Sand) or NAFUFILL BB2 of MC Bauchemic India Pvt Ltd (ready to use) at 0.126 kg/sqm as per manufacturers instructions complete all as specified and directed.
Note:- This layer will be allowed to Air Cure for 4 hours | 115 | Sqm | 250 ₹28,750 | 350 ₹40,250 | 200 ₹23,000 Lowest | 800 ₹92,000 | 280 ₹32,200 | 250 ₹28,750 |
| 8.00 | M&L for applying second layer of 1.5mm to 2.0mm thick slurry of cement at 0.242kg/sqm mixed with acrylic based polymer 'ARMOUR CRETE' of structural water proofing pvt ltd and silica sand by ratio 1:2:2 (Armour-crete : cement : silica sand) or 'POLYCRYL' of Green boro polychem pvt ltd and silica sand by ratio 1:2:2 (Polycryl : cement : silica sand) or ready to use PIDIFIN 2k of PIDILITE INDUSTRIES or SHALICRETE-500 of capital steel and chemicals pvt ltd and silica sand by ratio 1:2:2 (Shalicrete : Cement : Silica Sand) or NAFUFILL BB2 of MC Bauchemic India Pvt Ltd (ready to use) at 0.126 kg/sqm as per manufacturer's instructions complete all as specified and directed.
Note:-This layer will be allowed to Air Cure for 4 hours followed by water curing of 48 hours | 115 | Sqm | 200 ₹23,000 Lowest | 200 ₹23,000 Lowest | 200 ₹23,000 Lowest | 765 ₹87,975 | 250 ₹28,750 | 250 ₹28,750 |
| 9.00 | M&L for 40mm thick plain cement concrete 1:2:4, type B1 (using 20mm graded crushed stone aggregates) as in roof padding complete all as specified and directed. | 270 | Sqm | 160 ₹43,200 Lowest | 200 ₹54,000 | 240 ₹64,800 | 270 ₹72,900 | 200 ₹54,000 | 200 ₹54,000 |
| 10.00 | M&L for 10mm thick rendering in CM(1:3) mixed with water proofing compound as per manufacturer instruction on concrete surface and making the surface even and smooth without using extra cement as in required slope for draining out the rain water complete all as specified and directed.
Note:-Water proofing compound shall be measured and paid separately as supply only | 270 | Sqm | 250 ₹67,500 | 150 ₹40,500 | 180 ₹48,600 | 225 ₹60,750 | 120 ₹32,400 Lowest | 190 ₹51,300 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
2 May 2026, 6:00 pmClosed
GE AF Sambra
GE AF Sambra ATS Sambra Belgaum 591124
REPAIRS TO SEEPAGE TREATMENT, SUNKEN FLOOR AND MISC REPAIRS TO BILLET /CLASSROOM BLDGS IN SOUTH CAMP AT AFS UNDER GE(AF) SAMBRA
2026_MES_759885_1
GE(AF)/SAM/TOK-04 OF 2026-27
Open Tender
Civil Works
Item Rate
180 days
GE AF Sambra
Please refer Tender documents
9 documents required · 9 mandatory
₹500
GE AF Sambra
₹60,000
Yes
2 Jun 2026
10 Apr 2026
9 May 2026
10 Apr 2026
2 May 2026
27 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down cement plaster including racking out joint hacking for key scrubbing down with water etc., complete all as specified and directed. | - | Sqm | - | - |
| 2 | M&L for rendering 10 mm thick cement plaster in CM 1:6 for wall finished even & smooth complete all as specified and directed. | - | Sqm | - | - |
| 3 | M&L for rendering 15 mm thick cement plaster in CM 1:4 as in external wall & sunken floor finished even & smooth without using extra cement mixed with water prooffing compound complete all all as specified and directed. Note:-Water proofing compound shall be measured and paid separately as "Supply only" under respective item | - | Sqm | - | - |
| 4 | Supply only liquid water proofing compound complete all as specified and directed. | - | Ltr | - | - |
| 5 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed. | - | Cum | - | - |
| 6 | Demolition of cement concrete (unreinforced) of any description and in any position complete all as specified and directed. | - | Cum | - | - |
| 7 | M&L for applying first layer of cement slurry at 0.488 kg/ sqm mixed with Acrylic based polymer 'ARMOUR -CRETE' of structural water proofing Pvt Ltd by ratio 1:2 (one Armour Crete : Two cement) or 'POLYCRYL' of Green boro polychem Pvt Ltd by ratio 1:2 (one polycryl : Two cement) or Ready to use PIDIFIN 2k of PIDILITE INDUSTRIES or SHALICRETE-500 of capital steel and chemicals pvt ltd and silica sand by ratio 1:2:2 (Shalicrete : Cement : Silica Sand) or NAFUFILL BB2 of MC Bauchemic India Pvt Ltd (ready to use) at 0.126 kg/sqm as per manufacturers instructions complete all as specified and directed.
Note:- This layer will be allowed to Air Cure for 4 hours | - | Sqm | - | - |
| 8 | M&L for applying second layer of 1.5mm to 2.0mm thick slurry of cement at 0.242kg/sqm mixed with acrylic based polymer 'ARMOUR CRETE' of structural water proofing pvt ltd and silica sand by ratio 1:2:2 (Armour-crete : cement : silica sand) or 'POLYCRYL' of Green boro polychem pvt ltd and silica sand by ratio 1:2:2 (Polycryl : cement : silica sand) or ready to use PIDIFIN 2k of PIDILITE INDUSTRIES or SHALICRETE-500 of capital steel and chemicals pvt ltd and silica sand by ratio 1:2:2 (Shalicrete : Cement : Silica Sand) or NAFUFILL BB2 of MC Bauchemic India Pvt Ltd (ready to use) at 0.126 kg/sqm as per manufacturer's instructions complete all as specified and directed.
Note:-This layer will be allowed to Air Cure for 4 hours followed by water curing of 48 hours | - | Sqm | - | - |
| 9 | M&L for 40mm thick plain cement concrete 1:2:4, type B1 (using 20mm graded crushed stone aggregates) as in roof padding complete all as specified and directed. | - | Sqm | - | - |
| 10 | M&L for 10mm thick rendering in CM(1:3) mixed with water proofing compound as per manufacturer instruction on concrete surface and making the surface even and smooth without using extra cement as in required slope for draining out the rain water complete all as specified and directed.
Note:-Water proofing compound shall be measured and paid separately as supply only | - | Sqm | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
tender.pdf
Tender Documents • 1.03 MB
BOQ_851134.xls
BOQ • 3.43 MB
psii.pdf
Additional Documents • 1.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .