| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC H NO 106 D POCKET A MAYUR VIHAR PHASE II DELHI 110091 | DELHI | EAST DELHI | DELHI | 110091 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹20.7 L+₹1.0 L (5.25%)Rejected-Finance B 150 GROUND FLOOR BACK SIDE PANDAV NAGAR DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L2 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹35,000
Closing Date
1 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GARRISON ENGINEER (MES) DANAPUR CANTT
PROVN OF SECURITY POST AND ENTERY GATE AT SAINIK CHOWK AND PROVN OF CERTAIN REV AND MINOR WORK IN AGE BR II UNDER GE DANAPUR CANTT
2020_MES_392297_1
GE/DNR/T-56 OF 2020-21 / 8435/E8
Open Tender
Civil Works
Item Rate
180 days
DANAPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER
₹35,000
24 Dec 2020
3 Nov 2020
4 Dec 2020
3 Nov 2020
1 Dec 2020
17 Nov 2020
3 Nov 2020 - 16 Nov 2020
90 days
Amount
Boring holes 5m deep in soil for Single under reamed piles and getting out and disposal of soil to a distance of n.exc 50m (dia of pile 300mm) complete all as specified and directed.
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth, for foundation etc and getting out in soft/loose soil complete all as specified and directed.
Excavation over area n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L PCC 1:4:8 type-D2 (40mm graded aggregate) as in foundations, filling and mass concrete.sub base as in floorscomplete all as specified and directed.
M&L for Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L 40mm thick damp proof course to horizontal or vertical surfaces including necessary form work in cement concrete 1:2:4, type B-0 complete all as specified and directed.
Returning Filling in,including spreading, levelling, watering and well ramming in layers, not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material n exc 50 m and depositing where directed at level n exc 1.5m above the starting point.
M&L for hard core of gauge n.exc 63 mm deposited, spread and levelled in layers n.exc 15 cm thick with broken bricks, watered and rammed to a true surface complete all as specified and directed.
M&L reinforced cement concrete (M-25 Design mix) (using 20 mm graded stone aggregate) in foundation, footing, foundation beams, plinth beams, bases for columns, pedestal, under reamed piles, mass concrete, etc complete all as specified and directed.
M&L reinforced cement concrete (M-25 Design mix) (using 20mm graded stone aggregate) as in columns, pillars, posts, struts etc complete all as specified and directed.
M&L reinforced cement concrete (M-25 Design mix) (using 20mm graded stone aggregate) as in slabs supported on walls, beams and column in floors, roofs, landings, balconies, deck slabs and in shelves and the like complete all as specified and directed.
M&L reinforced cement concrete (M-25 Design mix) (using 20mm graded stone aggregate) as in beams, chajja, cantilevers, bressmummers, lintels over 1.5 m span complete all as specified and directed.
Use & waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (horizontal or sloping) for flat rough finished surfaces of concrete complete all as specified and directed.
Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete.
Use & waste of form work to sides of pillars, posts, struts, piers, columns and stanchions for rough finished, square, rectangular or polygonal surfaces of concrete complete all as specified and directed.
Use & waste of form work to edges of concrete flats, treads, breaks in floors window cills, concrete railing, openings in concrete walls, floor and roofs n exc 20 cm wide and side of RCC/PCC bands in walls, horizontal or sloping and similar work complete all as specified and directed.
Use & waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete complete all as specified and directed.
S&F MS TMT bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoopinbg for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Ditto all as per item No 21 above but 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L 15 mm thick rendering in two layers (10mm & 5mm ) on fair faces of bk / concrete surfaces in cm (1:4) with WPC (WPC measured & paid separetely) finished even and smooth (Without using extra cement ) complete all as specified and directed.
Supply only water proofing compound (liquid), ISI marked complete all as specified and directed.
M&L 15 mm thick rendering on fair faces of bk /concrete surfaces in cm (1:6), finished even and smooth (Without using extra cement ) complete all as specified and directed.
M&L rendering 10mm thick in CM 1:4 on concrete surfacves/ chajja/ ceiling, etc finished even and smooth without using extra cement complete all as specified and directed.
Preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of Primer complete all as specified and directed.
M&L for Prepration of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M & L preparation two coat of oil bound distember on new wall surface with priming surface with white putty complete all as specified and directed.
M&L for prepration of new steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate /plinth protection laid in suitable panels finished even and fair all as spd . 6mm Joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 85/25 or 80/100 gde and three part of sand ( all by weight) complete all as specified and directed.
M & L for 20 - 25 mm thick machine cut Kota stone slab as in flooring over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including 15 mm thick Screed bed or bedding layer of Cement Mortar (1:6) for laying Kota Stone tile, necessary grinding, rubbing, rounding to exposed edges and polishing in granite finish complete all as specified and directed.
M &L for machine cut kota stone slab 18-20mm thick as in riser of steps, skirting, dado,chamfered /nozing of edge and laid over 15 mm thick screed bed in cm 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete. (kota stone to be provided in step & skirting) complete all as specified and directed.
Glazed ceramic coloured tiles 350 x 450mm x 5mm to 7mm thick in skirting dados risers to steps etc set and jointed in neat cement slurry and pointed in coloured cement to match tiles over and including 10mm thick rendering in cm 1:4 complete all as specified as directed.
S&F steel windows with side hung shutter incl box type butt hinges with bow handle,steel peg stay, tower bolts ( each shutter having two tower bolts 100mm long ) complete with glazing bars dovetailed or welded complete all as specified and directed.
~Ditto~ all as per item No. 35.00 above but without glazing bars complete all as specified and directed.
S&F Mild steel framed works such as grills,gratings,etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work for portions framed and hung as gates, including pintle hinges, stops, hand made sliding bolts, etc conforming to Fe 290 Gde -E-165 complete all as specified and directed.
S&F Mild steel works as in hold fasts, clamps,plain angle cleats for securing purlins to wood trusses or rafters, and similar small conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
M&L PCC 1:2:4 type B1 ( using 20mm graded aggregate) as in bed blocks for hold fasts including necessary from work, PCC benching, copings etc complete all as specified and directed.
S&F 3mm thick sheet glass, ordinary quality glazing with oil putty in square n exc 0.50 sqm in each pane of 3mm thick complete all as specified and directed.
S&F Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks etc complete all as specified and directed.
M&L 75mm thick Cement concrete Type C2, 1:3:6 , 75mm thick (40 mm graded aggregate) as in sub base floor finished evevn & fair complete all as specified and directed.
Material and labour for 15 mm thick ultra designers coloured heavy duty floor / slab tiles of size and design as approved by GE set and jointed in neat cement slurry incl. 20mm thick screed bed in cement mortar 1:4 as in path complete all as specified and as directed
M&L screed bed 10 mm thick in cement mortar 1:4 on concrete surfaces with liquid water proofing compound @ 200 ml/50 kg per bag of cement or as per manufacturar instruction finished even and smooth without using extra cement over roof slab complete all as specified and directed. Note:- Water proofing compound shall be measured and paid seperately.
M&L for 15-17 mm thick prepolished granite stone slab, machine cut to size, as in dado/skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick on backing coat in CM 1:4 complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying two coats of oil bound distemper over a coat of primer including 3 mm thick Birla/ JK wall putty complete all as specified and directed.
Dismantling of floor, walls tiles including bedding but backing and rubbish off permises all as specified and directed
M&L for 10mm thick Light shade vitrified ceramic tiles in as in dado / skirting exceeding 0.36 sqm but not exceeding 0.42 sqm set & jointed in neat cement slurry and pointed in coloured cement to match the tile over and including 10 mm thick rendering in cement mortar 1 : 4 for fixing of wall tiles complete all as specified and directed.
M&L for 10mm thick Light shade vitrified ceramic tiles in floors / wall exceeding 0.36 sqm but not exceeding 0.42 sqm set & jointed in neat cement slurry and pointed in coloured cement to match the tile over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Resecuring or easing & adjusting without taking down Shutters of any description exc 1 sq. but n exc 2 sqm each complete all as spd and directed.
M & L for Hardcore of gauge exc. 63 mm but not exc. 100 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken bricks complete all as specified and directed.
M & L for 60 mm thick Machine pressed precast glazed colour reflection PCC interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006, M-35 grade as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 50 mm thick sand cusioning for laying of paver block complete all as specified and directed.
M & L for providing 100 mm thick cement concrete 1:4:8, type D-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor complete all as specified and directed.
M&L Cement concrete 1:2:4, type B-1 (using 12.5 mm graded stone aggregate) as in levelling course, roof padding, coping, etc complete all as specified and directed.
M&L cement concrete type B1, 1:2:4 (20 mm graded aggregate) 100mm thick in flooring finished even and smooth without using extra cement complete all as specified and directed.
Forming Contraction (Dummy) type `A' joint 65mm deep x 10mm wide filled with sealing compound all as specified and directed.
M & L for plain cement concrete M-10 Nominal Mix (using 20 mm graded stone aggregate), as cills and other similar bands, plinth course, copings, as directed including necessary form work as required complete all as specified and directed.
PAPPU ROY CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .