GE Gangtok
GE Gangtok New Mil Stn Gangtok, Sikkim 737102
REPAIR MAINT OF EXTERNAL LT ELECTRIFICATION AT OLD CANTT INCLUDING MS-02 TO MS-13 AREA UNDER GE GANGTOK
2022_MES_550646_1
8049AE8
Open Tender
Electrical and Maintenance Works
Works
182 days
GE Gangtok New Mil Stn Gangtok
As per tender documents
8 documents required · 8 mandatory
₹500
GE Gangtok
₹36,000
Yes
28 Oct 2022
8 Sept 2022
19 Oct 2022
8 Sept 2022
17 Oct 2022
15 Sept 2022
60 days
Amount
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m depth for taking out/ laying of under ground cables etc and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in hard/dense soil complete all as specified and as directed
Removal of surplus excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed.
Supplying and laying of DWC HDPE pipe .lSI marked in trenches or in cable ducts or fixed on walls using clamps along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. of size 50 mm outer dia complete all as specified and as directed by the Engr-in-Charge.
Supplying and laying of DWC HDPE pipe .lSI marked in trenches or in cable ducts or fixed on walls using clamps along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. of size 75 mm outer dia complete all as specified and as directed by the Engr-in-Charge.
Taking out old unserviceable, burnt, punctured aluminium conductor cable LT, PVC/XLPE, 1100 volts grade, of cross sectional area from the excavated trenches, ducts, laid in floors, along poles/ walls/ equipments etc, laid and passed through pipes or laid bare in road crossing/drains/paths/along walls/poles/along walls/poles/floors etc and in similar locations complete all as specified and directed by the Engineer-in-charge.
120 Sqmm 3.5 Core
95 Sqmm 3.5 Core
70 Sqmm 3.5 Core
50 Sqmm 3.5 Core
35 Sqmm 4 Core
25 Sqmm 4 Core
35 Sqmm 2 Core
25 Sqmm 2 Core
Supply and laying in trenches/through pipes or bare in road crossing/paths/drains/ducts/floors/along poles/walls/ceilling/equipments etc. Cable under ground, heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of following cross sectional area, including taking out old u/s cable and remove from site all as specified and directed by the Engr-in-charge:- (a) Earthwork & Excavation, GI pipe, DWC pipe etc shall be measured and paid separately under relevant items of this schedule. (b) The rate quoted by the bidder shall deemed to be inclusive of the cost of aluminium thimbles/lugs of suitable sizes
120 Sqmm 3.5 Core
95 Sqmm 3.5 Core
70 Sqmm 3.5 Core
50 Sqmm 3.5 Core
35 Sqmm 4 Core
25 Sqmm 4 Core
35 Sqmm 2 Core
25 Sqmm 2 Core
M&L for taking out faulty UG cable cutting faulty end, supplying and making straight through joint with heat shrinkable kit outdoor including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV volts grade complete of following cross ectional area (Note : Excavation & earth work, DWC pipe for protection if necessary will be measured and paid separately)
120 to 185 Sqmm 3.5 core
70 to 95 Sqmm 3.5 core
25 to 50 Sqmm 3.5/4 core
Laying only cable obtained against itme No 6 here in before, in trenches/through pipes or bare in road crossings/paths/drains/ducts/floors/along poles/walls/ceillings/ equipments etc of following cross sectional area, all as specified and directed by the Engr-in-charge:- (a) Earthwork and excavation, GI pipe, DWC pipe etc shall be measured and paid separately under relevant items of this schedule. (b) The rate quoted by the bidder shall deemed to be inclusive of the cost of aluminium thimbles/lugs of suitables sizes
150 Sqmm 3.5 Core
120 Sqmm 3.5 Core
95 Sqmm 3.5 Core
70 Sqmm 3.5 Core
50 Sqmm 3.5 Core
35 Sqmm 4 Core
25 Sqmm 4 Core
Taking out old unserviceable, GI tubing of any size upto 80 mm bore from the excavated trenches, ducts, floors, along poles/ walls/ equipments, road crossing/drains/ paths etc all as specified and directed by the Engineer-in-charge.
Supply and laying in trenches/under roads/ crossings are fixed to wall/pole, GI tubing light grade of size 50mm dia for protection of UG cables :- Payment for excavation and earth work shall be paid for separately under relevant items of schedule.
80 mm dia
50 mm dia
Disconnecting all cables connections and taking out u/s MCCB/MCB's and type/capacity upto 250 Amps, TP/FP/TPN, 415 volt from panel boards/feeder boxes and remove from site.
Supply and fixing following rating and breaking capacity MCCB with theromomagnetic release and terminal spreders in existing cubicle panel board including drilling holes in cubicle panel, making connections, connecting up using suitables size of lugs etc as required and directed by the Engr-in-charge:-
MCCB, 4 Pole, 400 Amps, 415 Volt, 25 KA
MCCB, 4 Pole, 250 Amps, 415 Volt, 25 KA
MCCB, 4 Pole, 200 Amps, 415 Volt, 25 KA
MCCB, 4 Pole, 160 Amps, 415 Volt, 25 KA
MCCB, 4 Pole, 125 Amps, 415 Volt, 18 KA
MCCB, 4 Pole, 100 Amps, 415 Volt, 18 KA
MCCB, 4 Pole, 63 Amps, 415 Volt, 18 KA
Supply and fixing in repairs 415V 10KA 'B' curve miniature circuite breaker (MCB) of TPN/FP 40 to 100 AMP and current carrying capacity in the DB complete with connection testing and commissioning.
Supply and fixing 1100 volts grade heavy duty 10 Sqmm stranded cable PVC insulated aluminium conductor, served with inner sheathing of PVC and overall PVC sheathed in sevice connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular
Supply and fixing 1100 volts grade heavy duty 16 Sqmm stranded cable PVC insulated aluminium conductor, served with inner sheathing of PVC and overall PVC sheathed in sevice connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular
Supply, installation, testing and commissioning factory made LT feeder pillar box (KIOSK) in repairs outdoor type platform mounted, CPRI approved suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having busbar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 CRCA steel sheet with double door shutter and locking arrangement, openable from front & back both including powder coated on both outer and inner surfaces of panel. The TPN aluminium bus bar not less than the 1.5 times the rated capacity of the incommer MCCB including 50x50x6mm thick angle iron frame work upto height of 0.9mtr above ground level (duly painted with synthetic enamel paint over a coat of red oxide primer on exposed surfaces) with and including following spares and including dismantling of old unserviceable existing feeder pillar box complete all as specified and as directed. (a) MCCB 4 pole, 25 KA 100 Amp-01 No (Incommer) (Havells Cat No IHLANF0100) (b) MCCB 4 pole, 25 KA 63 Amp-03 Nos (outgoing) (Havells Cat No IHLASF0063) (c) Phase indicating lamps (R-Y-B) 01 set (d) Multifunctioning meter with necessary CTs
M&L for earthing complete in repairs with advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgraded (zinc & alloy coated), ZINC coated (80-100) microns with pure Zinc(99.9%) & ALLOY COATING (200-250) microns. Earthing System confirming IS 3043. The outer and inner pipe should be 48.3mm & 26.4mm 2mtrs length, zinc coated with additional special Alloy coating 300mm on the topside for additional protection of the terminal. The annular space between the pipes being filled up with COMPACT FILL (CF) (Crystalline Conductive Compound). The COMPACT FILL (CF) mixture which is machine pressed in the pipes should not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity, The job includes digging the pits and refilling the same by BARONS electrodite OR conductolite back fill compound (Ground Enhancer), the BFC should be eco friendly it should not contain environmentally hazardous material/metal having ROHS certification from NABL accredited lab. The earth pit should be provided with a FRP OR EPCC earth pit cover for protection and safe guard of terminals. In areas where soil condition is bad, GOOD EARTH ie BLACK COTTON or MOISTUROUS NORMAL SOIL is to be arranged to fill the excavated pits by mixing the arranged soil with BFC 2 to 4 bags ELECTRODITE OR 2.4 BAGS CONDUCTILITE BFC FOR INSTALLATION OF EARTH. ELECTRODE. The electrode should be of galvnised (80-100 micron) along with earth lead as Galvanised steel strip of size 32 x 6mm, 7.5 m. including excavation earthwork etc connected to electrical eqpts/panels and testing on completion all as
M&L for plain cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as finishing road/concrete surface/ coping of poles including finishing to exposed concrete surfaces even and fair complete all as specified
M&L for cutting the existing hard standing/PCC/WBM road at a depth not less than 45 cm and 25 cm in width for passing of cable through GI pipe, returning filling in complete including finishing the surfaces by providing cement concrete (1:2:4) type B-2 (using 40mm graded stone aggregate upto 20 cm depth finishing to a uniform smooth surface to match the existing surface complete all as specified and directed. Note :- (i) GI pipes shall be measured and paid separately. (ii) Any damages made/caused to the HT/LT cables, water supply pipelines, OFC cables etc during the excavation works shall be made good by the contr as per original and to the entire satisfaction of Engr-in-Charge and GE Cost of the same is deemed to be included in the unit quoted rates.
SANJAY KAUSHIK
DHARMINDER SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .