| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC NEAR AVON PUBLIC SCHOOL DABHANW POST DANDI NAINI PRAYAGRAJ 211008 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211008 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹31.4 L+₹56,335 (1.83%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹32.4 L+₹1.5 L (4.99%)Rejected-Finance 12 L I G PRITAM NAGAR PRAYAGRAJ U P PIN 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹33.6 L+₹2.7 L (8.79%)Rejected-Finance 5 31 EWS PREETAM NAGAR ALLAHABAD 211011 | ALLAHABAD | ALLAHABAD | UTTAR PRADESH | 211011 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹34.7 L+₹3.9 L (12.6%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L5 | Rejected-Finance OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | P S TRADERS L5 | M/S vibhuti enterprises L4 | M/S SS Tarders L2 | Aawadh associates L6 | M/s SINGH CONTRACTOR WORKS L3 | NEXT POWER ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Ceiling Fan.
Taing down carefully Ceiling fan 1200/1400 mm sweep any size any capacity any sweep including dismentling of blade down rod fan for recognised defects at site or deposit to store complete all as specified and directed by Engi-in-Charge
Note : (i) refixing and reconnection etc of ceiling fan due painting/over hauling etc shall be measured and paid separately
(ii) Any damage or loss of fan during taing down shall be made good by the contractor at the own cost | 800 | Each Job | 100 ₹80,000 | 15 ₹12,000 | 15 ₹12,000 | 25 ₹20,000 | 50 ₹40,000 | 8 ₹6,400 Lowest |
| 2.00Dismantling/disconnection of ceiling fan for examination joint inspection preparation of inventry of each fan assessing listing nature and details for repair /overhauling /providing new lubricating, grease in bearing/bushes, re-assembling, commissioning and testing complete providing nuts, bolts, locking bolts, blades screws, split pin, rubber real, PVC connector, washers whereas required and refixing in position complete all as specified and directed by Engineer-in-charge. Note: All major repair such as replacement of Bush, bearing , condensor, shaft, connection wire, winding & painting will be measured & paid separately under S&F /M&L items here-in-after | |||||||||
| 2.01 | (a) Upto 4 Meters height. | 400 | Each Job | 100 ₹40,000 | 5 ₹2,000 Lowest | 25 ₹10,000 | 25 ₹10,000 | 70 ₹28,000 | 25 ₹10,000 |
| 2.02 | (b) Above 4 Meters height. | 100 | Each Job | 120 ₹12,000 | 5 ₹500 Lowest | 30 ₹3,000 | 25 ₹2,500 | 70 ₹7,000 | 25 ₹2,500 |
| 3.00 | M&L for removing of burnt winding from ceiling fan stator of size 1200mm/1400mm sweep and rewinding the same with equal gauge of super enameled copper winding wire, insulating paper, varnishing and testing complete incl transportation to contractor's work shop and bringing back to store and testing complete | 800 | Each Job | 250 ₹2,00,000 | 305 ₹2,44,000 | 240 ₹1,92,000 Lowest | 320 ₹2,56,000 | 320 ₹2,56,000 | 330 ₹2,64,000 |
| 4.00 | M&L for scraping all foreign materials with emery paper, cleaning the body, blades, legs, frame and down rod (preparatory work) for painting ceiling fan and painting with one coat of supper enameled white paint (spray paint)/grey paint and writing of MES No. with capital letter of size 20 mm height and 03 mm width with synthetic enameled black paint for Ceiling fan 1200mm/ 1400mm sweep complete all as specified and directed | 400 | Each | 50 ₹20,000 | 50 ₹20,000 | 45 ₹18,000 | 40 ₹16,000 | 50 ₹20,000 | 30 ₹12,000 Lowest |
| 5.00 | S&F in Replacement of gun metal bush suitable for ceiling fan any as per site requirements complete all as specified and directed | 50 | Each | 20 ₹1,000 | 40 ₹2,000 | 25 ₹1,250 | 45 ₹2,250 | 250 ₹12,500 | 10 ₹500 Lowest |
| 6.00Supply and fixing condenser with PVC clamp of the following capacities:- | |||||||||
| 6.01 | (a) 2.5 MFD | 400 | Each | 25 ₹10,000 Lowest | 32 ₹12,800 | 30 ₹12,000 | 36 ₹14,400 | 35 ₹14,000 | 30 ₹12,000 |
| 6.02 | (b) 3.15 MFD | 50 | Each | 30 ₹1,500 Lowest | 40 ₹2,000 | 33 ₹1,650 | 36 ₹1,800 | 45 ₹2,250 | 35 ₹1,750 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
13 Oct 2025, 6:00 pmClosed
GE WEST PRAYAGRAJ
Garrison Engineer (West), New Canttt, Prayagraj-211001
REPAIR/MAINT OF SUMMER/WINTER APPLIANCES AND INTERNAL ELECTRIFICATION OF DAD AREA AT NEW CANTT PRAYAGRAJ
2025_MES_730892_1
8854/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
NEW CANTT PRAYAGRAJ
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE WEST PRAYAGRAJ
₹1 L
Yes
10 Jan 2026
15 Sept 2025
20 Oct 2025
15 Sept 2025
13 Oct 2025
29 Sept 2025
Amount
Ceiling Fan. Taing down carefully Ceiling fan 1200/1400 mm sweep any size any capacity any sweep including dismentling of blade down rod fan for recognised defects at site or deposit to store complete all as specified and directed by Engi-in-Charge Note : (i) refixing and reconnection etc of ceiling fan due painting/over hauling etc shall be measured and paid separately (ii) Any damage or loss of fan during taing down shall be made good by the contractor at the own cost
Dismantling/disconnection of ceiling fan for examination joint inspection preparation of inventry of each fan assessing listing nature and details for repair /overhauling /providing new lubricating, grease in bearing/bushes, re-assembling, commissioning and testing complete providing nuts, bolts, locking bolts, blades screws, split pin, rubber real, PVC connector, washers whereas required and refixing in position complete all as specified and directed by Engineer-in-charge. Note: All major repair such as replacement of Bush, bearing , condensor, shaft, connection wire, winding & painting will be measured & paid separately under S&F /M&L items here-in-after
(a) Upto 4 Meters height.
(b) Above 4 Meters height.
M&L for removing of burnt winding from ceiling fan stator of size 1200mm/1400mm sweep and rewinding the same with equal gauge of super enameled copper winding wire, insulating paper, varnishing and testing complete incl transportation to contractor's work shop and bringing back to store and testing complete
M&L for scraping all foreign materials with emery paper, cleaning the body, blades, legs, frame and down rod (preparatory work) for painting ceiling fan and painting with one coat of supper enameled white paint (spray paint)/grey paint and writing of MES No. with capital letter of size 20 mm height and 03 mm width with synthetic enameled black paint for Ceiling fan 1200mm/ 1400mm sweep complete all as specified and directed
S&F in Replacement of gun metal bush suitable for ceiling fan any as per site requirements complete all as specified and directed
Supply and fixing condenser with PVC clamp of the following capacities:-
Taking down the ceiling fan, remove the down rod, Material and Labour for provisioning of new down rod made out of GI tubing medium grade cutting length as per site requirement, threaded and holes drilled both ends (dual arrangement), making holes – 02 Nos, painting with two coats of synthetic enamel white colour paint, fixing the down road to the fan and re-hanging the fan complete including their electric connections complete all as specified and directed. Note- GI tubing will be measured and paid separately under S&F item here-in-after.
S&F for GI tubing 15 mm bore medium grade ISI marked for fixing in item above complete all as specified and directed.
S&F for GI tubing 50 mm bore medium grade ISI marked for fixing on walls including PCC 1:3:6 type C-1 block 230x230x150 mm for grouting ends of pipe & all fittings for hanging of Ceiling fans complete all as specified and directed.
M&L for fan hook made out of MS flat 50x6 mm suitably shaped to mount on 40 mm dia GI pipe including welded MS bar 10 mm dia half round shaped & necessary nuts & bolts complete all as specified and directed.
M&L for replacement of celing fan shaft complete of size & quality as per existing 1200mm/1400mm complete all as specified and directed.
Material and labour for replacement of U/S stator block made of laminated sheets of size and quality as per existing complete all as specified and directed by Engr-in-Charge
S&F for electronic socket size, rotary, 5 speed step type regulator, 120-230 V white finish complete all as specified and directed.
S&F fan blade set (set of three) made out of aluminium sutaible for 1200 mm sweep ceiling fan, as per exisitng size and guage all directed by Engr-in-Charge Make : As per sample
Description same all as per srl item No 15 here-in-above but 1400 mm sweep complete all as specified and directed.
M&L for replacement of celing fan shaft complete of size & quality as per existing complete all as specified and directed.
M&L for replacement of U/S stator block made of laminated sheets of size and quality as per existing complete all as specified and directed.
Supply and fixing of Outer cover of ceiling fan as per existing shape and size complete all as specified and directed by E-in-Charge .
Supply & fix for PVC canopy of 1200/1400 mm sweep ceiling fan complete all as specified and directed.
S&F in replacement PVC insulated three core wire copper conductor 1100 Volt grade of size 23/0.0076 mm complete all as specified and directed.
S&F in Replacement of ball bearing (No 6201, 6202 & 6203) suitable for Ceiling fan 1200mm/1400mm suitable as per site requirements complete all as specified and directed.
S&F for PCB for BLDC Ceiling Fan of capacity 1200mm sweep complete all as specified and directed.
Exhaust Fan. Taing down carefully exhaust fan /wall fan /pedestal fan /air circulators any size any capacity any sweep including dismentling of blade down rod fan for recognised defects at site or deposit to store complete all as directed by Engi-in-Charge Note : (i) refixing and reconnection etc of fan due painting /over hauling etc shall be measured and paid separately. (ii) Any damage or loss of fan during taing down shall be made good by the contractor at the own cost
Disconnecting & Taking down Exhaust fan/wall fan/Pedestal fan/ air circulator any make any size from any position at site transporating to MES store Yard & dismantling blades opening the stator and rotor of fan and providing new lubricating, grease in bearing/bushes, reassembling incl providing nuts, bolts, locking bolts, blades screws, split pin, rubber reel, PVC connector, rubber pad, washers whereas required all as directed by Engineer-in-charge. Note: All major rerpair such as replacement of Bush, bearing , condensor, shaft, connection wire, winding & painting will be measured & paid separately under supply only items here-in-after
Refixing and testing Exhaust fan/wall fan/Pedestal fan/ air circulator any make any size from any position at site in position etc including Provision of cable from fan to Ceiling Rose PVC flexible three core cable of size 23/0.0076 copper conductor ISI Mar white in colour complete all as specified and directed Note : Cable will be measured and paid separately
S&F in replacement PVC insulated three core wire copper conductor 1100 Volt grade of size 23/0.0076mm complete all as specified and directed.
Description same all as per serial Item No 25 here in above but 1.0 sqmm complete all as specified and directed.
S&F in Replacement of ball bearing suitable for following sizes:-
(a) Exhaust fan/wall fan/pedestal fan upto 380mm sweep complete all as specified and directed.
(b) Exhaust fan / pedestal fan / Air circulator 450mm to 600mm sweep complete all as specified and directed.
Material and Labour for removing of burnt winding from exhaust fan/ Air Circulators/ Wall mounted fans/ pedestal fans rewinding the same with equal gauge of super enameled copper winding wire, insulating paper, varnishing and testing complete incl transportation to work shop and bringing back to store and testing for following fans:-
(a) Exhaust Fan 9” sweep complete all as specified and directed.
(b) Exhaust Fan 12” sweep complete all as specified and directed.
( c) Exhaust Fan 18” sweep complete all as specified and directed.
(d) Wall Mounted/Pedestal Fan any sweep complete all as specified and directed.
Supply and fixing the revolving mechanism of wall mounted fan suitable for 400 mm sweep or as per existing type all as per specified and directed by E-in-Charge
Supply and fixing the stator block of wall mopunted fan as per existing design and material suitable for 400 mm sweep complete all as specified and directed.
Supply and fixing the rotor block as per existing suitable for 400 mm sweep wall mounted fan complete all as specified and directed.
S&F in Replacement of gun metal bush suitable for pedestal fan/ exhaust fan all as per site requirements complete all as specified and directed.
Supply and fixing capacitors with PVC clamp of the following capacities:-
M&L for scraping all foreign materials with emery paper, cleaning the body, blades, legs, frame and down rod (preparatory work) for painting of exhaust fan/air circulator fan/pedestal fan and painting with one coat of supper enameled white paint (spray paint)/grey paint and writing of MES No. with capital letter of size 20 mm height and 03 mm width with synthetic enameled black paint all as directed.
Exhaust Fan 9”/12" sweep complete all as specified and directed.
Exhaust Fan 18” sweep single phase/ three phase complete all as specified and directed.
Material and Labour for making circular holes suitable for fixing of 18” sweep Exhaust fans by cutting the wall any thickness/ required circumstances for exhaust of air and including grouting of rag bolts and nuts complete including finishing of disturbed surfaces by using cement mortar 1:3 complete all as required at site and directed by the Engineer-in-Charge.
Description same all as per item No 35 here in above above but suitable for 12”/9" sweep exhaust fan complete all as specified and directed.
Supply and fixing in replacement of wall mounted fan blade suitable for 400 mm sweep fan as per existing complete all as specified and directed by Engr-in-Charge.
S&F for exhaust fan MS blade 12" to 15” as per existing complete all as specified and directed by Engr-in-Charge.
S&F for exhaust fan MS blade 18” to 24” as per existing complete all as specified and directed by Engr-in-Charge.
M&L for MS front frame suitable for mounting of stays of 9" exhaust fan made out of MS Sheet not less than 1.6mm thick painted with two coat of synthetic enamelled over a coat of red oxide primer complete with neccesarry fixing accessories such as nut, bolts washers etc & fixing to wall all as per existing & site requirement as directed by Engr-in-charge incl taking down old unsv complete all as specified and directed.
Description same all as per serial item No 40 here in above but suitable for 12" exhaust fan complete all as specified and directed.
Description same all as per serial item No 40 here in before but suitable for 18" exhaust fan complete all as specified and directed.
M&L for MS stay work (set of 4) suitable for 9" exhaust fan made out of not less than 20 x 3mm MS strip bent to shape complete painted with two coat of synthetic enamelled over a coat of red oxide primer complete with neccesarry fixing accessories such as nut, bolts washers etc & fixing to wall all as per existing & site requirement as directed by Engr-in-charge incl taking down old unsv .
Description same all as per serial item No 43 here in above but suitable for 12" exhaust fan made out of not less than 25 x 4mm MS strip complete all as specified and directed.
Description same all as per serial item No 43 here in above but suitable for 18" exhaust fan made out of not less than 25 x 4mm MS strip complete all as specified and directed.
M&L for circular / rectangular framed shutters/louvers suitable for 9" exhaust fan made out of MS sheet not less than 1 mm thick for frame & not less than than 0.6mm thick for shutter painted with two coat of synthetic enamelled over a coat of red oxide primer complete with neccesarry fixing accessories all as per existing & as per site requirement & directed by Engr-in-charge.
Description same all as per serial item No 47 here in above but suitable for 12" exhaust fan complete all as specified and directed.
Description same all as per serial item No 47 here in above but suitable for 18" exhaust fan complete all as specified and directed.
M&L for replacement of exhaust fan shaft for 9/12 " complete of size & quality as per existing complete all as specified and directed.
S&F in replacement of MS louvers shutters on wall suitable for 380/450 mm sweep exhaust fan including suitable size of nut, bolts & washer complete all as specified and directed.
Supply and fixing in replacement of exhaust fans PVC body of size 250mm sweep including taking down the old unserviceable one and depositing the same in MES yard for further disposal as per existing procedure.
Supply and fixing in replacement of Wall mounting fans PVC body of size 400 mm sweep including taking down the old unserviceable one and depositing the same in MES yard for further disposal as per existing procedure complete all as specified and directed.
Geysers. Taking down the geyser from existing position for general cleaning/overhauling, cleaning and descaling the tank and assembly with suitable detergent and making fully serviceable (the item required for making the geyser serviceable, shall be measured and paid seperately in respective item of Schedule mentioned here in after) and refixing in new/old position and testing complete all as specified and directed.
Supply and fixing in replacement of fusible plug type air release valve complete all as specified and directed.
Supply and fixing rubber gasket of thickness 5mm for geyser assembly of 06/08/09 holes complete all as specified and directed.
Supply and fixing in replacement of Aperture Plate assembly of 06/08/09 holes suitable for 25/35/50 Ltrs geysers with suitable size of nut bolts/stud/washer complete all as specified and directed.
Supply and fixing indicating lamp for geyser rectangular/round type red/green suitable for any type of geyser complete all as specified and directed.
Supply and fixing in replacement of sheet metal bottom/upper cover of Geyser with existing size and gauge 18/20 SWG suitable for 25/35/50 Ltr complete all as specified and directed
Supply and fixing in replacement of bottom show cover of Geyser of gauge 18 SWG of capacity 25 Ltr/35 Ltr/50 Ltr complete all as specified and directed.
Supply and fixing in replacment glass wool of superior quality fixing on geyser 25/35/50 ltr geyser complete all as specified and directed.
M&L for preparation of body of geyser any size by knotting and stopping of outer surface, repainting the complete outer surface of geyser with two coat of synthetic enameled paint complete all as specified and directed.
S&F for PVC connection (stainless steel) 15mm dia, 600mm long (Heavy duty) hot water pipe complete all as specified and directed.
S&F for Chromium Plated Connection Pipe 15mm dia, 600mm long (Heavy duty) hot water pipe complete all as specified and directed.
S&F in repair stop valves cast copper alloy screwed down high pressure with crutch or butter fly handle concealed type screwed both ends of size 15 mm bore complete all as specified and directed
S&F in repair Thermostat suitable for geyser range 20 degree to 80 degree (ISI marked) complete all as specified and directed. Make-Thermo king/Theeta/Bajaj/Recold or equivalent
S&F in replacement of heating element 1.5 KW/2 KW, round / cup type with rubber gasket complete all as specified and directed. Make: Theeta/Bajaj/CG
S&F in repair plug top 15 Amp 3 pin complete all as specified and directed. Make :- Anchor/ CONA/ PLAZA
M&L for repair to leaking copper/steel tank of 25 Ltr/50 Ltr capacity by brazing as necessary to make leak proof complete all as specified and directed.
M&L for repair of apparatus plate assembly of 06/08/09 holes suitable for 25/35/50 Ltrs geysers by brazing as necessary to make leak proof complete all as specified and directed.
S&F fastener mild steel 100mm long x 10mm dia with pin and bolts complete for hanging of geyser and making good the disturbed surfaces including plastering and white washing complete all as specified and directed
S&F fastener mild steel 150mm long x 10mm dia with pin and bolts complete for hanging of geyser and making good the disturbed surfaces including plastering and white washing complete all as specified and directed.
S&F in replacement electronic sensor for thermal setting as per sample kept in GE’s office complete all as specified and directed. .
S&F in replacement of MCB DP 32 Amps, 230 Volts, AC , 10 KA with indication & enclosure complete all as specified and directed.
S&F in replacement of Non return valve verticletype screwed for both ends with 15mm bore GI pipe. Complete all as specified and as directed.
Air Conditioner. Overhauling & servicing of window /Split/tower type Air Conditioners up to 2.0 Ton capacity of any make and carry out of following tasks at different location of different establishment including taking down the AC (if required) from existing location , refixing / commissioning and testing the same after overhauling complete including the following :- (a) Inspection taking down, opening (dismantling) ,washing the condensor and cooling coil complete with water by fixing indoor pvc jacket as required and cleaning with air blower and testing complete (b) Checking / examine operation of condensor, blower motor, cooling coil and checking the air circulation to ensure complete movement of working part trouble free (c) Inspection of leakage in system and removal obstruction if any (d) Inspecting all electrical connection and remove if any defects (e) Top up Refrigerent gas if required. Note : Replacement of new parts/worn out parts in lieu of unserviceable/burn out part shall be measured and paid separately as supply only items of Schedule A.
Supply only the following spare parts for up to 2.0 ton capacity of Tower/window/ Split type AC any make & any model.
(i) Air Filter Make and model-as per existing
(ii) Starting relay Make-Totaline/Epcos/CLASSIC/Whirlpool
(iii) Starting capacitor 120-150 mfd Make- Totaline / Epcos /Whirlpool
(iv) Starting capacitor 100-120 mfd. Make- Totaline / Epcos /Whirlpool
(v) Running capacitor 40-60 mfd. Make- Totaline/ Epcos/Whirlpool
(vi) Running capacitor 30-36 mfd. Make- Totaline / Epcos /Whirlpool
(vii) Running capacitor 4-6 mfd. Make- Totaline/ Epcos/Whirlpool
(viii) Thermostate switch Make as per existing
(ix) Propeller fan suitable for window/split type AC Make- As per existing
(x) Cooling Coil Make- as per existing
(xi) Condensor coil Make- as per existing
(xii) Outer cover duly painted for Window/split AC
(xiii) Three pin metalic socket outlet suitable for sheet metal enclosure Make : Havells/HPL/Legrand
(xiv) Three pin metallic plug top suitable for sheet metal enclsoure Make : Havells/HPL/Legrand
(xv) Front grill for split/window AC Make as per existing
(xvi) Wiring kit with thimbles
(xvii) Power Contactors 240 volts AC 50HZ 16-25 Amps range.
(xviii) Power contactor 415V AC, 50 Hz 20-32 Amps range
(xix) Overload protector suitable for compressor as per existing.
(xx) Blower for indoor unit/window AC as per existing.
Removing the burnt/defective sealed compressor unit any type of any make from Air Conditioner window type up to 2.0 ton capacity by cutting of suction and discharge lines unscrewing the foundation nuts & bolts etc, supply and fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with filling of refrigerant gas (in quoted rate), welding/brazing work and tightening foundation nuts & bolts including etc all as directed. Note:- (a) Capillary, drier, copper tubing etc are inclusive in unit rate. (b) New compressors will be purchased from authorised dealer only.
All as per Sr item No. 80 here in above above but for air conditioner split type 1.5 ton capacity complete all as specified and directed.
M&L for replacement of damaged copper tubing of dia 1/2 inch including insulation with heavy duty foam and brazing work in Split Air conditioners for discharge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.
M&L for replacement of damaged copper tubing of dia 1/4 inch including insulation with heavy duty foam and brazing work in Split Air conditioners for discharge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.
M&L for replacement of damaged insulation with heavy duty foam for copper tubing of split air conditioners complete all as specified and directed.
S&F in replacement of PVC drain pipes of size 15 mm from indoor unit to exist point as per design including accessories clmps fastners complete all as specified and as directed by Engineer-in-charge.
Repair to Air conditioner Window/Split type upto 2.0 ton to capacity by testing the leakage in system by filling of Nitrogen gas upto suitable pressure and repairing of leakage with brazing work, cleaning and flushing out the complete system, replacing of drier/filter if required, making the complete system leak proof, vacuuming the system and charging Refrigernt gas any type as existing and testing etc complete all as specified & directed. Note :(a) Drier/filter, capillary and copper tubing are inclusive in unit rate.(b) Contractor should be responsible if leakage of refrigerent gas after repair topup on completing job and done same job without extra payment.
Supply and replacement blower Motor 1/5 or 1/6 HP 230V AC, 50 Hz suitable for Air conditioner window type upto 2.0 ton capacity as per existing model complete all as directed and specified.;
Supply and fix in replacement blower Motor 0.2/0.25 HP for Air conditioner split type of capacity 1.5 ton/2.0 ton as per existing model complete as directed and specified.
Repair and fixing blower Motor of split type /window type Air Conditioners of any make and any capacity for making air conditioner serviciable complete all as directed and specified.
Repair and fixing Condensor Motor (outdoor motor) for split type Air conditioner as per existing model of any make and any capacity for making air conditioner serviciable complete all as directed and specified.
Repair and fixing Printed Circuit Board of split type /window type Air Conditioners of any make and any capacity for making air conditioner serviciable complete all as directed and specified.
Supply and fix in replacement Printed Circuit Board as per existing model to repair to split type/window type Air Conditioners of any make and type of any capacity any complete all as directed, Make - Voltas/Carrier/toshiba.
Supply and replacement for wireless remote control unit for split/window type airconditioner as per existing model complete all as specified and directed.
S&F in replacement and install of Indoor Unit with wireless remote control unit and Adjustable Mode, Anti- dust Filter for better indoor air quality with minimum 5 star Inverter Split type of capacity of 1.5 Ton complete all as specified and directed, Make : Blue star/Voltas /LG or equivelent approved by GE Note - Old unit to be deposited in MES store yard)
S&F in replacement and install of outdoor Unit with 5 star Split type of capacity of 1.5 Ton. Complete all as specified and directed. Make : Blue star/Voltas/LG or equivelent as approved Note-Old unit to be deposited in MES store yard
M&L for outdoor unit stand for wall mounting/floor mount type or floor mounted complete factory made as recommended for make Airconditioner and approved by Engr-in-charge.
M&L for Shifting and refixing of split type AC (Indoor and Outdoor units) of any make and any type after servicing and charging of gas (M410a/R134a/R-22/r32) by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the system as existing and testing etc complete all as specified & directed. Note :(a) Dismantling and refixing of split AC are including in quoted rate. (b)Drier capillary,copper tubing,refrigernt gas,Insulation and LDPE pipe are inclusive in quoted rate.(c) making hole and filling the hole on wall with PCC (1:2:4) type BO (Using 12.5mm graded stone aggregade, 15mm thick rendereing in cement mortar (1:3) good the disturbed surface with existing colour matching are inclusive in quoted rate.
M&L for attending day to day complaints and rectifying faults like decarbonizing connections in the AC Box, , any burning due to over loading in AC and restoring connection of AC with wire or thimbles,attending and rectifying faults related to AC like drain water leakage ,filter cleanig,remote setting etc and related to stabilizers (5 to 8 KVA) incl Sunday & Holidays complete all as directed by Engineer-in-Cgarge. Note : (i) All T&P required shall be provided by contractor including ladders of any size as per requirement at site. (iii) Minor items like machine screw, plastic clamps, insulation tape, nails, flexible pipe, thimbles, lugs for contactor, etc shall deemed to be included in the unit rate. (iv) The major items replaced during repairs shall be measured and paid under respective items of Sch 'A'.
Voltage Stabilizer. M&L for opening unserviceable automatic voltage stabilizer for repair, detection of fault and its repair cleaning of serviceable parts, replacement/repair of unserviceable or worn out parts soldering of terminal connection and testing after repair, painting with one coat of synthetic enamel paint externallycomplete all as specified and directed including sign writing "AGE E/M New Cantt" all as directed any makes. Note: (a) Replacement of new parts/worn out parts in lieu of unserviceable/worn out parts shall be measured and paid separately.(b) The flexible 3 core cable, 40/.0076, 23/.0076, 70/.0076 to be provided at least 1.5 RM is included in unit rate.
Capacity 5 KVA / 4 KVA
Supply only the following spare parts suitable for automatic voltage stabilizer of any make and capacity :-
Volt Meter (0-300 volts)
Control Relay
IC controlled circuit for 5KVA/4 KVA
Control transformer
Low/high voltage cut off and TDR system
Main transformer for 5 KVA/4 KVA
M&L for rewinding of boost/buck transformer of stabilizer with copper wire of existing gauge and same number of turn with best quality insulating material including testing complete and refixing back electrically and mechanically all as directed and specified by Engr-in-Charge of following capacity :-
Capacity 5 KVA/4 KVA
Internal Electrification. Taking down carefully sub main wiring of any type/size complete with MCB DBs MCB, isolators wooden batten, concealed/surface conduit/casing caping etc. removing materials including accessories for taking credit and making good disturbed surface to match the existing complete all as specified & directed.
M&L for concealed sub main wiring using FRLS/FRLSH PVC insulated, unsheathed stranded copper conductor cable single core of following sizes of voltage rating upto and including 1100 volts drawn in and including rigid PVC concealed conduit of dia not less than 20 mm dia medium grade with all fittings and accessories along with one run of PVC insulated unsheathed stranded copper conductor as earth continuity conductor complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required and making good the disturbed surface shall deemed to be included in the quoted unit rate.
(a) 2x4.0 sq. mm + 1x4.0 sq. mm earth wire
(b) 2x6 sq. mm + 6x sq. mm earth wire
(c) 2x10 sq. mm + 10x sq. mm earth wire
(d) 4x10.0 sq. mm +1x10.0 sq. mm earth wire
M&L for surface sub main wiring using FRLS/FRLSH PVC insulated, unsheathed stranded copper conductor cable single core of following sizes of voltage rating upto and including 1100 volts drawn in and including non metallic PVC rigid, medium grade not less than 20mm dia surface conduit / non metallic PVC casing and caping with all fittings and accessories along with one run of PVC insulated unsheathed stranded copper conductor as earth continuity conductor complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.
(a) 2x2.5 sq. mm + 1x2.5 sq. mm earth wire
(b) 2x4.0 sq. mm + 1x4.0 sq. mm earth wire
(c ) 2x6 sq. mm + 6x sq. mm earth wire
Taking down carefully aluminium / copper point wiring any type for one light , fan, socket power point or buzzer controlled by one switch complete including fitting / fixtures such as switches, ceiling roses, holder, socket, light fitting etc; for credit and making good disturbed surfaces of walls, ceilings etc
M&L for point wiring with FRLS/FRLSH PVC insulated unsheathed stranded copper conductor cable 1.5 Sqmm (nominal area) 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium grade concealed conduit with all fixing accessories of 20mm dia, and including modular sunken box, cover plate / frame for any module as requiredat site with all accessories and including fixing with switch, socket, ceiling rose, fan regulator,holder, etc. and making good to disturbed conceal surfaces complete all as specified and directed for the following :- Note:(a) Colour code of wire shall be strictly followed , Red for Phase , Black for neutral and green for earth wire. (b) The unit rate quoted is deemed to be inclusive of cost of cutting chases in wall for providing concealed conduit and making good to match with existing finish/surface. (c) Only 04 point shall be allowed is one circuit.
(a) One light/fan/bell point controlled by one switch
(b) One point for socket outlet 5 amps on independent board
(c) One point for socket outlet 5 amp same board
(d) One light point controlled by two 2-way switches
(e) All as per same above but for one socket outlet 16 Amp on independent board with 4.0 Sq mm cable and 4.0 Sq mm earth wire.
M&L for point wiring with FRLSH PVC insulated unsheathed stranded copper conductor cable 1.5 Sqmm (nominal area) 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium grade concealed conduit with all fixing accessories of 20mm dia, using new pressed steel sunk terminal boxes of thickness not less 1.2mm, new 3mm thick laminated sheet cover with brass screw and cup washers with all accessories including fixing with switch, socket, ceiling rose, fan regulator,holder, etc. and making good to disturbed conceal surfaces complete all as specified and directed for the following :- Note:(a) Colour code of wire shall be strictly followed , Red for Phase , Black for neutral and green for earth wire (b) The unit rate quoted is deemed to be inclusive of cost of cutting chases in wall for providing concealed conduit and making good to match with existing finish/surface
(a) One light/fan/bell point controlled by one switch
(b) One point for socket outlet 5 amps on independent board
(c) One point for socket outlet 5 amp same board
(d) One light point controlled by two 2-way switches
(e) All as per same above but for one socket outlet 16 Amp on independent board with 4.0 Sq mm cable and 4.0 Sq mm earth wire.
M&L for point wiring with FRLSH PVC insulated unsheathed stranded copper conductor cable 1.5 Sqmm (nominal area) 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC casing and caping/PVC conduit of appropriate size on wall/roof surface with all fixing accessories including fixing with switch, socket, ceiling rose, fan regulator,holder, etc. and polycarbonate modular/modular GI sunken boxs, and modular sunken box, cover plate / frame for any module as required at site with all accessories and making good to disturbed conceal surfaces complete all as specified and directed for the following :- Note:(a) Colour code of wire shall be strictly followed , Red for Phase , Black for neutral and green for earth wire.
(a) One light/fan/bell point controlled by one switch
(b) One point for socket outlet 5 amps on independent board
(c) One point for socket outlet 5 amp same board
(d) All as per same above but for one socket outlet 16 Amp on independent board with 4.0 Sq mm cable and 4.0 Sq mm earth wire.
Supply and fix in replacement of A C starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB, one 25 Amps socket and one 25 Amps plug top prewired complete as specified after taking out old unserviceable starter unit all as directed.
Receiving complaints from Concern Incharge of Internal section (Power House) lodged by the occupants of electrification nature, rectification of the fault as per the complaint lodged by the user onward KWH meter in respect of main distribution board having switch fused, MCB distribution board in sheet metal enclosure, point wiring fixture for light/fan/bell/light/Ceiling Fan, testing of Electronic meters or power socket complete repairs to the extent by removing connections from the system removing faults in wires, battens, conduit, sunken boxes, junction boxes, main switches, MCBs/DBs utility light fitting, lamp holders AC ceiling/exhaust fans and other connected fixtures of the internal electrification including providing of petty stores such as wires of appropriate size and conductor matching to existing one up to the length of 1 mtr including insulation tap, screws, nuts as required to rectified the fault with regard to the complaint lodged and refixing of fittings, fixture to their position as dismantled complete all as directed at site to the entire satisfaction of Engr-in-charge/users. Note - (i) All spares required and accessories, required for repairing will be paid under relevant items of this schedule. Instructions -(a) Attending complaint including taking down/refixing of LED light fittings and repair/ Replacement part (Labour ) and minor repair shall be measured against under relevant of Sch "A items . (b) Cost of material and labour for replacement of new items shall be measured and paid separately . (c) Panalty : Penalty for not attending complaints within stipulated time frame will be the liable to Rs 500.00 of per day for non attending the complaints multiple number of days of delay (d) Priority -1 (to be done within 8 hours from time of lodging complaint): No light, repair/replacement of switches, fan regulator, replacing burnt/damaged wiring, replacement of burnt MCBS and Main switch, voltage fluctuation, current leakage and replacement of tube lights.
S&F in repalacement of modular switch 1 way, 6 amps, 230V AC, one way complete all as specified & directed.
S&F in repalacement of modular socket out let 2-in-1, 3 pin, 6 amp flush type 2 module complete all as specified & directed.
S&F in repalacement of modular switch flush type 16 amps, 230V AC single pole one way complete all as specified & directed.
S&F in repalacement of modular socket out let 2-in-1, 3 pin, 5 & 16 amp flush type 2 module complete all as specified & directed.
S&F in repalacement of modular switch 2 way, 6 amps, 230V AC, one way complete all as specified & directed.
S&F in repalacement of modular bell push flush type 6 amp, 1 module SP , 230V AC complete all as specified & directed.
S&F in repalacement of modular fan regulator, 5 stepped, electronic type, single phase, 120 watt, socket size incl connection complete all as specified & directed.
S&F in repalacement of switch piano flush button single pole one way 6 amps all as specified and as directed
S&F in repalacement of switch 2 way, 6 amps, 230V AC, one way complete all as specified & directed.
S&F in repalacement of socket outlet 5 pin 6 amp flush type all as specified and as directed
S&F in repalacement of socket out let multipurpose 3 pin 16 amp and one 3 pin 6 amp controlled by one switch all as specified and as directed.
S&F in repalacement of switch piano flush button single pole one way 16 amps all as specified and as directed
S&F in repalacement of switch & socket out let combination multipurpose 3 pin 16 amp and one 3 pin 6 amp controlled by one switch all as specified and as directed.
S&F in repalacement of PVC insulation tape of width -18mm in length of 25 mtr ISI marked for proper insulation of joints in wire where as required or directed.
S&F in repalacement of ceiling rose surface backelite three terminals. Make Anchor/havells/legrand
S&F in repalacement of MCB 63 to 100 Amps TPN 10 KA C curve 415 volt complete all as specified and directed.
S&F in repalacement of MCB SPN 63 AMPS KA C curve 240 Volt complete all as specified and directed.
S&F in repalacement of MCB SPN 40 AMPS 10 KA C curve 240 volt complete all as specified and directed.
S&F in repalacement of MCB Single pole 6 to 32 Amp, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F in repalacement of MCB Single pole 63 Amp, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F in repalacement of MCB Single pole 40 Amp, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F in repalacement of MCCB 100 Amp 4 pole 25 KA at 415 V fixed type complete all as specified and directed.
S&F in repalacement of call bell Dingdong type AC 230 Volts single pole complete all as specified and directed.
S&F in repalacement of bell push flush type 6 amp, 230V AC complete all as specified & directed.
S&F in repalacement of Modular metal flush box of 12 module complete all as specified and dircted.
S&F in repalacement of Modular metal flush box of 8 module complete all as specified and dircted.
S&F in repalacement of Modular metal flush box of 6 module complete all as specified and dircted.
S&F in repalacement of Modular metal flush box of 4 module complete all as specified and dircted.
S&F in repalacement of Modular metal flush box of 3 module complete all as specified and dircted.
S&F in repalacement of Modular metal flush box of 2 module complete all as specified and dircted.
S&F in repalacement of Modular white plate cover with frame of 12module complete all as specified and dircted.
S&F in repalacement of Modular white plate cover with frame of 8 module complete all as specified and dircted.
S&F in repalacement of Modular white plate cover with frame of 6 module complete all as specified and dircted.
S&F in repalacement of Modular white plate cover with frame of 4 module complete all as specified and dircted.
S&F in repalacement of Modular white plate cover with frame of 3 module complete all as specified and dircted.
S&F in repalacement of Modular white plate cover with frame of 1/2 module complete all as specified and dircted.
Supply and fixing Angle / Batten type Lamp holder, PVC/Polycarbonate type with back plate suitable for light fittings complete all as spcified and directed.
Supply & Fix in replacment single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Am "B" Curve.complete all as specified and directed.
Taking down main switches fuse unit, MCB/Kit kat distribution board any type/size/capacity with steel enclosure along with MCB’s /Kit kat fuse of any amps/ways including wooden board or from steel board and making good disturbed surfaces complete all as specified and as directed. Note: Any disturbed surfaces of wall will be matched properly as the existing colour surfaces.
Supply and fixing in replacement of factory made epoxy polyester powder coated distribution board SP & N 4 way fabricated from recommended thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including aluminium alloy bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 2 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB all as specified and directed. (Make : Legrand/GE Power/ Schnieder or equivalent approved by GE) (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs / thimbles / sleeves and its cost shall be deemed to be included under respective item of Sch. (c) making good and finishing of disturbed surfaces matching with the exisitng surfaces plastering, wood box work, painting if reqd any type incl ecessary fixing arrangements complete deemed to be included under respective item of sch. (d) Make of MCBs /MCCBs and MCB DBs shall be same makes.
Supply and fixing in replacement of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from recommended thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including aluminium alloy bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB all as specified and directed. Make : Legrand/GE Power/ Schnieder or equivalent approved by GE) NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. (c) making good and finishing of disturbed surfaces matching with the exisitng surfaces plastering, wood box work, painting if reqd any type incl ecessary fixing arrangements complete deemed to be included under respective item of sch. (d) Make of MCBs/MCCBs and MCB DBs shall be same makes.
Supply and fixing in replacement of factory made epoxy polyester powder coated distribution board SP & N 12 way fabricated from recommended thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including aluminium alloy bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP/SPN MCB as incomer and 8 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB all as specified and directed. Make : Legrand/GE Power/ Schnieder or equivalent approved by GE) NOTE- (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. (c) making good and finishing of disturbed surfaces matching with the exisitng surfaces plastering, wood box work, painting if reqd any type incl ecessary fixing arrangements complete deemed to be included under respective item of sch. (d) Make of MCBs/MCCBs and MCB DBs shall be same makes.
Supply and fixing in replacement of factory made epoxy polyester powder coated distribution board TP & N 4 way fabricated from recommended thick CRCA sheet with metal double door (IP-43 protection ) door IK 09 fixed flush to wall and suitable for universal mounting and including aluminium alloy bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable MCBs as complete all as specified and conforming to IS: 8623 alongwith cable end box for above TPN/isolator all as specified and directed. Make : Legrand/GE Power/ Schnieder or equivalent approved by GE) NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs / thimbles / sleeves and its cost shall be deemed to be included under respective item of Sch. (c) making good and finishing of disturbed surfaces matching with the exisitng surfaces plastering, wood box work, painting if reqd any type incl ecessary fixing arrangements complete deemed to be included under respective item of sch. (d) Make of MCBs/ MCCBs and MCB DBs shall be same makes.
Supply and fixing in replacement of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-43 protection) and double door IK-09 fabricated from recommended thick CRCA sheet and fixed on wall and suitable for universal mounting and including aluminium alloy bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 125 4 pole MCCB as incommer and 16 to 32 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB all as specified. Make : Legrand/GE Power/ Schnieder or equivalent approved by GE) NOTE :- (a) MCBs/MCCB shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. (c) making good and finishing of disturbed surfaces matching with the exisitng surfaces plastering, wood box work, painting if reqd any type incl ecessary fixing arrangements complete deemed to be included under respective item of sch. (d) Make of MCBs/MCCBs and MCB DBs shall be same makes.
S&F for MCB 63 to 100 Amps TPN 10 KA C curve 415 volt complete all as specified and directed.
S&F for MCB SPN 40-63 AMPS KA C curve 240 Volt complete all as specified and directed.
S&F for MCB SPN 32 AMPS 10 KA C curve 240 volt complete all as specified and directed.
S&F for MCB Single pole 6 to 32 Amp, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F in repair MCB Single pole 40 -63 Amp, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
Supply and fix in replacement of MCCB 125 Amp 4 pole 25 KA at 415 V fixed type complete.complete all as specified and directed.
Supply and fix in replacement of MCCB 100 Amp 4 pole 25 KA at 415 V fixed type complete.complete all as specified and directed.
Supply and fix in replacement of MCCB 160 Amp 4 pole 36 KA at 415 V fixed type with shhet metal enclousre compitable to mount it including all lugs, seprater etc complete all as specified and directed.
M&L for cutting / boring of PCC/hard standing at a depth not more than 15 cm deep and 15 cm in breadth for passing earthing conductor and making good the disturbed surfaces with PCC (1:2:4) type B-0 or cement mortar (1:3) complete all as specified and directed.
Supply and fixing in replacement of 20 mm dia Non Metallic Rigid PVC casing caping/conduit pipe of size, ISI Marked, conforming to IS 9537 Part III, medium grade including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete in all respect as specified and directed.
All as per item No 164 here in above but size 25 mm dia complete in all respect as specified and directed.
Supply & fixing in replacement of worn out/rusted sunken box of following sizes with pressed MS/GI steel terminal boxes of depth not less than 50 mm, flush type of thickness lot less than 1.22 mm of following size along with new 3.0 mm thick plastic laminated sheet cover of suitable size including cutting/drilling hole and fixing switches, sockets, fan regulator etc as removed from old sheet and fitted with cadmium plated screw washer and making good to disturbed surface with cement mortar complete in all respect as specified and directed.
(a) 100 mm X 100 mm
(b)175 mm X 100 mm.
(c)250 mm X 200 mm.
Supply and fixing in replacement of Decorative, wall mounting, fixture with plastic body (City type -1) as per sample approved by Engr-in-charge including 9 W LED lamp B22 all as specifed and directed.
Supply and fixing in replacement of 36 W LED 2'x2' (cool day/warm white) Panel Ultra slim recess mounted LED module with 120 Lumen /watt high brightness LED package and unique pattern de-glaring PP diffuser and PS LGP de-glaring diffuser sheet for glare free uniform light distribution suitable for armstrong / grid ceiling applications all as directed by Engr-in-Charge. Make Philips or equivalent as approved by GE
Supply and fixing in replacement of 40 W LED 2'x2' Panel Ultra slim recess mounted LED module 120 Lumen /watt with high brightness LED package and unique pattern de-glaring PP diffuser and PS LGP de-glaring diffuser sheet for glare free uniform light distribution suitable for armstrong / grid ceiling applications all as directed by Engr-in-Charge. Make Philips or equivalent as approved by GE
Supply and fixing of a deep recessed down light for comfort on eye suitable for versetile application such as offices retail 06 watt LED, including driver fixing arrangements & connecting with three core copper cable including taking down old worn out light complete all as directed by Engr-in-Charge Make : Philips /Bajaj/havells or equivalent as approved by GE
Description same all as per Item No 170 here in above but 12 watt complete all as specified and directed. Make : Philips /Bajaj/havells or equivalent as approved by GE
Description same all as per Item No 170 here in above but 15 watt complete all as specified and directed. Make : Philips /Bajaj/havells or equivalent as approved by GE
S & F in replacement of LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make : Philips /Bajaj/havells or equivalent as approved by GE
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
M&L in replacement of energy saver LED battan fitting 20 watt,120 Lumen /watt, 230 Volts, single tube mounting including with electronic driver LED Printed board, end cover, connector box etc and accessories, prewired, LED including required fixing arrangements and electrical connection two core copper cable from ceiling rose to led light fitting all as directed. Make Philips/Bajaj/ Havells or equivalent as approved by GE
M & L in replacement of bracket for building security light made out of 40 mm bore GI pipe medium grade not less than 1.2 mtr length bent at 120 degree to shape fixed on pole/wall with and including 50x6mm FI clamps = 02 Nos with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primercomplete
Supply and fixing in replacement of LED street light fitting 35 Watt 120 Lumen /watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Schedule of Credit (MINUS) Rs. 1,67,448.00 B/F from Serial Page No. [Note : Details of items for schedule of credit is given on Srl Page No. ] This amount shall be automatically deducted to arrive at tendered sum
M/S SS Tarders (BID ID -3449716)
M/s SINGH CONTRACTOR WORKS (BID ID -3450052)
M/S vibhuti enterprises (BID ID -3443856)
P S TRADERS (BID ID -3442863)
Aawadh associates (BID ID -3443953)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .