MR SE ENM RAIPUR RICHA(DFLT)
EinC E/M
Providing Annual Electrification Repair work in various Residential Buildings and Non Residential Buildings under PWD E/M Sub Division Kondagaon (C.G.)
202118
SYSTEM TENDER NO NIT NO: 135/S.E.E/M Raipur /2026-27 Dated:.16-10-2026
RESTRICTED TENDER
WORKS
PERCENTAGE
EinC E/M
Required Past Technical Experience: As per NIT
9 documents required · 9 mandatory
Public Works Department (PWD)
WORKS
MR SE ENM RAIPUR RICHA(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B C D
EinC E/M
E/M Circle, Raipur
E/M DIVISION KANKER
No
124
202118
5 Nov, 2026 5:30:00 PM IST
11 Nov, 2026 11:30:00 AM IST
16 Oct, 2026 7:30:00 PM IST
120
SYSTEM TENDER NO NIT NO: 135/S.E.E/M Raipur /2026-27 Dated:.16-10-2026
Providing Annual Electrification Repair work in various Residential Buildings and Non Residential Buildings under PWD E/M Sub Division Kondagaon (C.G.)
9750.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
1300000.00
2
10 Nov, 2026 5:30:00 PM IST
1300000
0.00
0.00
As per NIT
06
0.00 INR
19d 21h 55m
9 documents required · 9 mandatory
₹0
₹9,750
16 Oct 2026
16 Oct 2026
11 Nov 2026
16 Oct 2026
10 Nov 2026
To enable entering data into the sheet, please click on 'Enable Editing'.
Please insert items from 12th row.
Every row will be considered as a distinct item.
The row, in which the two fields- 'Item Code' and 'Description' are blank, will not be considered.
If 'CREDIT ITEM' is not entered, default value '0' will be taken.
If 'Calc Field' is not entered, default value 'N' will be taken.
MAX ITEM LIMIT IN EACH EXCEL FILE IS 1000
NIT SCHEDULE FOR ANNUAL ELECTRIFICATION REPAIR WORKS IN VARIOUS RESIDENTIAL & NON-RESIDENTIAL BUILDINGS UNDER PWD E/M SUB DIVISION KONDAGAON, DIST. KONDAGAON C.G.
PAC : 13.00 Lacs
S. No. Department SOR Year Item Code Department UOM Qty Ref Serial No CREDIT ITEM (0/1) Calc Field(Y/N) b
1 PWD ELECT 2020 2.10 Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.10.1 Short Point Point 9 0 0 N
PWD ELECT 2020 2.10.2 Medium Point Point 6 0 0 N
PWD ELECT 2020 2.10.3 Long Point Point 6 0 0 N
PWD ELECT 2020 2.10.4 Extra Long Point I Point 11 0 0 N
PWD ELECT 2020 2.10.5 Extra Long Point II Point 10 0 0 N
2 PWD ELECT 2020 2.11 Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 2.11.1 Short Point Point 6 0 0 N
PWD ELECT 2020 2.11.2 Medium Point Point 7 0 0 N
PWD ELECT 2020 2.11.3 Long Point Point 5 0 0 N
PWD ELECT 2020 2.11.4 Extra Long Point I Point 8 0 0 N
PWD ELECT 2020 2.11.5 Extra Long Point II Point 8 0 0 N
3 PWD ELECT 2020 2.15 Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in surface complete as per specification and IS: 9537 (2000 Part 5) 2.15.1 20 mm Metre 120 0 0 N
PWD ELECT 2020 2.15.2 25 mm Metre 80 0 0 N
4 PWD ELECT 2020 3.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 3x1.5 sq. mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed, Steel/FRLS PVC conduit and providing and fixing 5A piano type switch, phenolic laminated sheet etc. as per specification and IS: 694 (2010) 3.1.1 Short Point Point 45 0 0 N
PWD ELECT 2020 3.1.2 Medium Point Point 112 0 0 N
PWD ELECT 2020 3.1.3 Long Point Point 52 0 0 N
5 PWD ELECT 2020 3.3 Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed, Steel/FRLS PVC conduit and providing and fixing piano type 6 amp switch and 3 pin 6 amps socket outlet, phenolic laminated sheet, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010) 3.3.1 Short Point Point 8 0 0 N
PWD ELECT 2020 3.3.2 Medium Point Point 9 0 0 N
PWD ELECT 2020 3.3.3 Long Point Point 10 0 0 N
PWD ELECT 2020 3.3.4 Extra Long Point I Point 7 0 0 N
PWD ELECT 2020 3.3.5 Extra Long Point Il Point 2 0 0 N
PWD ELECT 2020 3.3.6 Extra Long Point Ill Point 2 0 0 N
6 PWD ELECT 2020 3.4 Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface/ concealed, FRLS PVC conduit and providing and fixing piano type 16 amp switch and 6 pin 16 amps socket outlet, phenolic laminated sheet, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010) 3.4.1 Short Point Point 8 0 0 N
PWD ELECT 2020 3.4.2 Medium Point Point 7 0 0 N
PWD ELECT 2020 3.4.3 Long Point Point 8 0 0 N
PWD ELECT 2020 3.4.4 Extra Long Point I Point 9 0 0 N
PWD ELECT 2020 3.4.5 Extra Long Point Il Point 2 0 0 N
PWD ELECT 2020 3.4.6 Extra Long Point Ill Point 2 0 0 N
7 PWD ELECT 2020 3.6 Wiring for light point/ exhaust fan point/ call bell point with 3x1.5 sq. mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed, Steel/FRLS PVC conduit and providing and fixing 5/6 amp modular type switch, modular base and cover plate etc. as per specification and IS: 694 (2010) 3.6.1 Short Point Point 16 0 0 N
PWD ELECT 2020 3.6.2 Medium Point Point 22 0 0 N
PWD ELECT 2020 3.6.3 Long Point Point 26 0 0 N
8 PWD ELECT 2020 3.8 Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed, Steel/FRLS PVC conduit and providing and fixing modular type 6 Amp switch and 3 pin 6 amps socket outlet, modular base and cover plate, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010) 3.8.1 Short Point Point 6 0 0 N
PWD ELECT 2020 3.8.2 Medium Point Point 8 0 0 N
PWD ELECT 2020 3.8.3 Long Point Point 7 0 0 N
PWD ELECT 2020 3.8.4 Extra Long Point I Point 7 0 0 N
PWD ELECT 2020 3.8.5 Extra Long Point Il 3 0 0 N
9 PWD ELECT 2020 3.9 Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for Phase, Neutral & earth in existing surface / concealed, Steel/FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) and providing and fixing modular type 16 Amp switch and 6 pin 16 amps socket outlet, modular base and cover plate, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010) 3.9.1 Short Point Point 5 0 0 N
PWD ELECT 2020 3.9.2 Medium Point Point 5 0 0 N
PWD ELECT 2020 3.9.3 Long Point Point 5 0 0 N
PWD ELECT 2020 3.9.4 Extra Long Point I Point 6 0 0 N
PWD ELECT 2020 3.9.5 Extra Long Point Il Point 2 0 0 N
PWD ELECT 2020 3.9.6 Extra Long Point Ill Point 2 0 0 N
10 PWD ELECT 2020 3.11 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit / PVC casing caping as per specification and IS: 694 (2010) 3.11.1 1 x 1.5 sq. mm Metre 324 0 0 N
PWD ELECT 2020 3.11.2 2 x 1.5 sq. mm Metre 618 0 0 N
PWD ELECT 2020 3.11.12 2 x 2.5 sq. mm Metre 920 0 0 N
PWD ELECT 2020 3.11.13 3 x 2.5 sq. mm Metre 465 0 0 N
PWD ELECT 2020 3.11.16 6 x 2.5 sq. mm Metre 244 0 0 N
PWD ELECT 2020 3.11.19 9 x 2.5 sq. mm Metre 170 0 0 N
PWD ELECT 2020 3.11.23 3 x 4 sq. mm Metre 230 0 0 N
11 PWD ELECT 2020 4.5 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as per specification. 4.5.3 3 Module Each 6 0 0 N
PWD ELECT 2020 4.5.6 8 Module Each 7 0 0 N
PWD ELECT 2020 4.5.7 12 Module Each 7 0 0 N
PWD ELECT 2020 4.5.8 16 Module Each 6 0 0 N
12 PWD ELECT 2020 5.1 Supplying and fixing following piano type switch, socket, other accessories on the existing switch box/ cover including connections etc. as per specification. 5.1.1 5/6 amps one way switch Each 292 0 0 N
PWD ELECT 2020 5.1.3 Bell push Each 4 0 0 N
PWD ELECT 2020 5.1.4 15/16 amps switch Each 31 0 0 N
PWD ELECT 2020 5.1.5 3 pin 5/6 amp socket outlet Each 195 0 0 N
PWD ELECT 2020 5.1.6 6 pin 15/16 amp socket outlet Each 31 0 0 N
PWD ELECT 2020 5.1.12 Fan regulator Electronic, step type moving all round Each 146 0 0 N
PWD ELECT 2020 5.1.13 Ceiling rose 3 pin 5 amps Each 124 0 0 N
PWD ELECT 2020 5.1.15 Batten/ angle holder Each 110 0 0 N
13 PWD ELECT 2020 5.4 Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 5.4.1 5/6 amps one way switch Each 170 0 0 N
PWD ELECT 2020 5.4.3 Bell push Each 8 0 0 N
PWD ELECT 2020 5.4.4 15/16 amp switch Each 18 0 0 N
PWD ELECT 2020 5.4.5 3 pin 5/6 amp socket outlet Each 41 0 0 N
PWD ELECT 2020 5.4.6 6 pin 15/16 amp socket outlet Each 20 0 0 N
PWD ELECT 2020 5.4.8 Fan regulator (one module size) electronic stepped type moving all rounds Each 44 0 0 N
PWD ELECT 2020 5.4.9 Fan regulator (two module size) electronic stepped type moving all rounds Each 29 0 0 N
PWD ELECT 2020 5.4.18 25/32 amp A.C. Starter switch Each 7 0 0 N
PWD ELECT 2020 5.4.20 Ceiling rose 3 pin 5 amp Each 88 0 0 N
PWD ELECT 2020 5.4.22 Batten/ angle holder Each 52 0 0 N
14 PWD ELECT 2020 5.7 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as per specification. 5.7.1 Ordinary (simple) Each 5 0 0 N
PWD ELECT 2020 5.7.2 Deluxe Each 7 0 0 N
15 PWD ELECT 2020 5.8 Providing and fixing following size FRLS PVC insulated, PVC sheathed, flexible copper conductor wire on the floor/ wall, or side of the table/ door etc. as per specification. 5.8.2 1.0 sq. mm two core Metre 405 0 0 N
16 PWD ELECT 2020 6.1 Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, earthing etc. complete as required. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments. 6.1.3 1200 mm sweep Each 13 0 0 N
17 PWD ELECT 2020 6.7 Supplying, installation, testing and commissioning of 250/ 300 mm sweep 1400 rpm medium duty (continuous running) exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 Each 4 0 0 N
18 PWD ELECT 2020 6.19 Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.19.3 18/20 watt {4 feet} Each 100 0 0 N
19 PWD ELECT 2020 6.28 Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 6.28.5 36 watt Each 10 0 0 N
PWD ELECT 2020 6.28.6 45 watt Each 8 0 0 N
PWD ELECT 2020 6.28.7 60 watt Each 4 0 0 N
PWD ELECT 2020 6.28.8 90 watt Each 4 0 0 N
20 PWD ELECT 2020 6.38 Supplying, fixing, testing and commissioning of following 230/250 volts capacitors in existing ceiling fans/ exhaust fan at all locations as per specification. P.F. should be greater than 0.9 6.38.2 2.5 MFD Each 50 0 0 N
PWD ELECT 2020 6.38.3 3.15 MFD Each 87 0 0 N
PWD ELECT 2020 6.38.4 4 MFD Each 12 0 0 N
21 PWD ELECT 2020 6.68 Supplying , Installation, testing and commissioning of following type LED Driver for LED Street lights / Flood Lights, IP 65 by approved make as required. 6.68.3 36 watt Each 34 0 0 N
PWD ELECT 2020 6.68.4 50 watt Each 40 0 0 N
22 PWD ELECT 2020 7.8 Supplying and fixing metal clad busbar chamber made of 2.0 mm thick CRCA MS powder coated sheet with 4 strip copper busbars of following capacity and length, complete with all accessories, including earthing the body etc. as per specification. 7.8.1 100 amps x 300mm long Each 5 0 0 N
PWD ELECT 2020 7.8.4 200 amps x 300mm long Each 2 0 0 N
PWD ELECT 2020 7.8.5 200 amps x 450mm long Each 2 0 0 N
23 PWD ELECT 2020 7.9 Providing and fixing metal clad, SP&N switch fuse unit (re-wirable), 230/250 volts, with porcelain re-wireble fuses including drilling holes on the board, connections, earthing the body etc. as per specification. (Thimbeling shall be paid separately). 7.9.1 32 amps Each 20 0 0 N
PWD ELECT 2020 7.9.2 63 amps Each 1 0 0 N
24 PWD ELECT 2020 7.10 Providing and fixing metal clad, TP&N switch fuse unit (re-wirable), 415/500 volts, with porcelain re-wireble fuses including drilling holes on the board, connections, earthing the body etc. as per specification. (Thimbeling shall be paid separately). 7.10.2 63 amps Each 3 0 0 N
PWD ELECT 2020 7.10.3 100 amps Each 6 0 0 N
PWD ELECT 2020 7.10.4 200 amps Each 2 0 0 N
25 PWD ELECT 2020 7.11 Providing and fixing porcelain re-wireble fuse carrier and base unit on wooden board including drilling holes on the board, screws, connections etc. as per specification. (Thimbeling shall be paid separately). 7.11.1 16 amps Each 4 0 0 N
PWD ELECT 2020 7.11.2 32 amps Each 17 0 0 N
PWD ELECT 2020 7.11.3 63 amps Each 15 0 0 N
PWD ELECT 2020 7.11.4 100 amps Each 18 0 0 N
PWD ELECT 2020 7.11.5 200 amps Each 6 0 0 N
26 PWD ELECT 2020 9.1 Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 9.1.3 3 pole MCCB, 25-100A, Adjustable Thermal Release, 18KA Each 0 0 0 N
PWD ELECT 2020 9.1.4 3 pole MCCB, 100A, Adjustable Thermal - Magnetic Release, 25KA Each 0 0 0 N
27 PWD ELECT 2020 9.3 Supplying and fixing on surface/ recess following way, 240 volts SP&N MCB distribution board consumer unit of sheet steel phosphatized and powder painted, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) 9.3.2 2 + 8 way Each 2 0 0 N
PWD ELECT 2020 9.3.3 2 + 12 way Each 2 0 0 N
28 PWD ELECT 2020 9.10 Supplying and fixing SP MCB, 240 volts, 'B' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.10.1 6 amps to 32 amps Each 502 0 0 N
29 PWD ELECT 2020 9.16 Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.16.5 63 amps Each 46 0 0 N
30 PWD ELECT 2020 9.19 Supplying and fixing following rating, 240 volts TWO POLE ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.19.2 40 amps Each 20 0 0 N
31 PWD ELECT 2020 12.1 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as per specification and IS Code 3043: 1987(R 2016) Set 4 0 0 N
32 PWD ELECT 2020 12.3 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016) Set 3 0 0 N
33 PWD ELECT 2020 12.4 Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as per specification. Metre 38 0 0 N
34 PWD ELECT 2020 12.12 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering, excavation and refilling the trench etc. as per specification. Metre 50 0 0 N
35 PWD ELECT 2020 12.17 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as per specification. Metre 270 0 0 N
36 PWD ELECT 2020 15.5 Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 15.5.12 3.5 x 35 sq. mm. Metre 180 0 0 N
PWD ELECT 2020 15.5.13 4 x 10 sq. mm. Metre 365 0 0 N
PWD ELECT 2020 15.5.14 4 x 16 sq. mm. Metre 255 0 0 N
PWD ELECT 2020 15.5.15 4 x 25 sq. mm. Metre 240 0 0 N
37 PWD ELECT 2020 15.8 Supplying and laying following sizes one number FRLS PVC insulated/ XLPE, PVC sheathed, unarmoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 15.8.1 2 x 4 sq. mm Metre 345 0 0 N
PWD ELECT 2020 15.8.2 2 x 6 sq. mm Metre 265 0 0 N
PWD ELECT 2020 15.8.3 2 x 10 sq. mm Metre 230 0 0 N
38 PWD ELECT 2020 15.23 Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. . 15.23.13 3½ X 35 sq. mm (28 mm) Each 12 0 0 N
PWD ELECT 2020 15.23.23 4 X 10 sq. mm (22 mm) Each 30 0 0 N
PWD ELECT 2020 15.23.24 4 X 16 sq. mm (22 mm) Each 37 0 0 N
PWD ELECT 2020 15.23.25 4 X 25 sq. mm (25 mm) Each 8 0 0 N
39 PWD ELECT 2020 23.11 Supply, installation, testing and commissioning of 1-3 HP 1 phase submersible motor starter cum control wall/ floor mounted type made out of not less than 1.6 mm thick MS sheet and comprising of following panel mounting switchgears there in including connection inter-connection etc. as per specification. a) Phase indicating lamps with fuses and toggle switches 1 set b) 1/2/3 HP 1 phase DOL starter with over load and no volt relay 1 No c) 25 A "C" curve DPMCB 1 No d) Voltmeter 0-250 V 1 set e) Ammeter 0-10 A 1 set Each 3 0 0 N
40 PWD ELECT 2020 23.14 Supplying, laying and fixing following size submersible cable along with GI/PVC/HDFC pipe line or laid in ground etc as per specification and IS: 694 (2010). Note: Cable should be rust proof, safe from oil / Grease and under water Chemical / abrasion Resistant. 23.14.2 3x2.5 sqmm Metre 245 0 0 N
41 PWD ELECT 2020 30.1 Earth work in all type soil except soft rock / hard rock with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling of excavated soil in trench / pit to ground level complete as per specification. cum 35 0 0 N
42 PWD ELECT 2020 31.1 Rewinding of ceiling fan by copper enameled wire of suitable gauge including all other required material i.e. insulation varnish, connection leads, oiling greasing etc complete with testing including dismantling & refitting of fan at site. (old copper wire will become the property of contractor) 31.1.1 48” (1200 mm sweep ) Each 61 0 0 N
43 PWD ELECT 2020 31.5 Replacement of defective ball bearing by approved make of suitable size bearing of all size of ceiling fan including dismentaling, disambling, assembling and reiftting as per specification. Each 44 0 0 N
LIST OF APPROVED MATERIALS FOR THE WORK- Providing Annual Electrification Repair work in various Residential Buildings and Non Residential Buildings under PWD E/M Sub Division Kondagaon (C.G.)
S.No. NAME OF ITEM MAKE MODEL
1 SWITCHES (MODULAR) 1. HAVELLS Myrano Crabe Tree
2. Legrand Myrius , Mylink
3. M.K. Elements
4. Schneider Livia
2 SWITCHES (Non MODULAR) 1. Winner
3. Legrand Britzy
4. Anchor Penta
3 PVC Wires (Fire Retardant )1.5 Sqmm. /2.5 Sqmm. /4 Sqmm. & 6 Sqmm. 1. RR Kabel
4 PVC Pipe & its accessories (a) 2 mm Thick For Concealed wiring as well as for for gurface 1. Precision
6 DB 1. Schneider
7 MCCB 1. Schneider
8 Air Circuit Breaker 1. L&T
9 Armoured/Unarmoured Cable (Power Cable HD) 1. R.R
10 Celling Fan 1200 mm/1400 mm 1. Havells Velocity
2. Bajaj GRACE LX
3. Orient Electric
4. Crompton High Speed
11 Frsh air Fan/ Exhaust Fan (300/380/450 mm) 1. Bajaj
12 Frsh air Fan/ Exhaust Fan (300/380/450 mm) 1. Bajaj
13 Saddle 0.9 mm Thickness 1. Galvanised best Quality
14 Switch Board (a) Metallic 1. Best make made of M.S. Sheet All Size 60 mm deep & thickness 8 SWG upto 20x30 cm and 16 SWG of larger sizes.
15 Cover of switch board 1. Best make laminated sheet (Hylem) 3.00 mm thick
16 LED light (luminaries) LED Bulb & LED Street light fitting & LED flood light 1. Philips Note:- LED Chips from Nichia , Cree, GE, Osram, Citizen, Bridgelux, Lumiled
2. Ledvance (Osram)
17 HDPE PIPE B CLASS 1. Reliance
18 GI Pipe "B" Class 1. Tata
3. Prakash Surya
19 Air-Conditioner 1. Daikin
20 High Mast pole/ Street light pole 1. Bajaj ISO : 2026 & BS EN : 10025 BSEN ISO 1461
Note (1) In one Building one make - accessories / fitting will be allowed. (2) Wire shall be ISI Marked following colour coding of wires Shall be followed in wiring :- Phase : Red / Yellow/ Blue (Three Phase Wiring) Live : Red (Single Phase wiring) Neutral : Black Earth : Green Executive Engineer PWD E/M Division, Kanker (C.G.)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
3389733406084652734_202118_Affidavit_affidavit.docx
NIT • 0.01 MB
4894769294471532981_202118_Durg NIt_NIT kondagaon AR 13lac (1).xlsx
NIT • 0.05 MB
7214758888671781529_202118_Term Condition and other Docu_Annexure E Kondagaon AR 13lac (1).doc
NIT • 0.05 MB
7214758888671781529_202118_Term Condition and other Docu_Approved Make List Kondagaon AR 13lac (1).xlsx
NIT • 0.01 MB
7214758888671781529_202118_Term Condition and other Docu_Cover letter kondagaon Ar 13lac (1).docx
NIT • 0.02 MB
7214758888671781529_202118_Term Condition and other Docu_FLYSHEET l NIT for Kondagaon AR 13lac (1).doc
NIT • 0.03 MB
7214758888671781529_202118_Term Condition and other Docu_Form A 2.13 Kondagaon AR 13lac (1).doc
NIT • 0.15 MB
7214758888671781529_202118_Term Condition and other Docu_NEW NIT 2.10 for FORM A ON LINE (5) kondagaon 13lac (1).doc
NIT • 0.30 MB
7214758888671781529_202118_Term Condition and other Docu_Proforma kondagaon AR 13lac (1).docx
NIT • 0.02 MB
7214758888671781529_202118_Term Condition and other Docu_TS 37 26-27 (3).docx
NIT • 0.01 MB
7214758888671781529_202118_Term Condition and other Docu_Long mow.docx
NIT • 0.04 MB
7214758888671781529_202118_Term Condition and other Docu_Short Notice mow 2.docx
NIT • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .