CONSTRUCTION OF GOVT.GIRLS COLLEGE BUILDING I/C. WATER SUPPLY, SANITERY FITTINGS & ELECTRIFICATION WORK AT GARIYABAND, DISTT. GARIYABAND. (GARIYABAND DN.)
200729
NIT NO: 994/TC/2026-27
RESTRICTED TENDER
WORKS
PERCENTAGE
15 days
CE(Raipur)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
6 documents required · 6 mandatory
Public Works Department (PWD)
WORKS
MR Yognarayan sahu(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B
CE(Raipur)
PWD Circle-2,Raipur
Gariyaband Division
120
15
No
0
200729
22 Oct, 2026 5:00:00 PM IST
27 Oct, 2026 10:00:00 AM IST
1 Oct, 2026 5:00:00 PM IST
NIT NO: 994/TC/2026-27
CONSTRUCTION OF GOVT.GIRLS COLLEGE BUILDING I/C. WATER SUPPLY, SANITERY FITTINGS & ELECTRIFICATION WORK AT GARIYABAND, DISTT. GARIYABAND. (GARIYABAND DN.)
231600.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
46302000.00
2
26 Oct, 2026 5:00:00 PM IST
46302000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
20d 23h 37m
6 documents required · 5 mandatory · 1 optional
₹0
₹2.3 L
1 Oct 2026
1 Oct 2026
27 Oct 2026
1 Oct 2026
26 Oct 2026
LIST OF APPROVED MATERIALS FOR E/F WORK AT NEWLY PROPOSED GIRLS COLLEGE BUILDING AT GARIYABAND BLOCK GARIYABAND DIST. GARIYABAND (C.G.)
1 Switch and other accessories with plate and Board
1 Schneider(Livia)
2 Havell's (Crabtree)
3 Legrand (My rius)
2 PVC Pipe size 2 mm thick for conceled as well as for surface wiring ISI Mark/20 mm/ 25 mm size Heavy Duty
3 Saddle 0.9 MM Thick
4 PVC Copper Wire Stranded with FRLS Wire
1 Havell's 4 Gloster
5 MCB/MCCB Enclosures & DB
1 Havell's 4 Schneider
2 C & S 5 Legrand
6 Switch Fuse unit
1 Havell's- ISI Mark 3 C & S
2 L & T 4 Indo Asian
7 Armoured Cable/ Unarmoured Cable
1 Havell's 4 RR Cable
1 Crompton (Surebreeze) 4 Havell's
2 Orient (Ujala Air)
3 Usha (Apollo LX)
9 Fresh Air Fan / Wall Fan / Exhaust Fan
1 Usha 4 Orient
10 Tube Light Fitting 20/40 Watt
1 Bajaj 3 Havell's
2 Crompton 4 Philips (Signify)
11 Street Light LED
3 Philips (Signify)
12 LED Light surface/Panel
2 Philips (Signify)
To enable entering data into the sheet, please click on 'Enable Editing'.
Please insert items from 12th row.
Every row will be considered as a distinct item.
The row, in which the two fields- 'Item Code' and 'Description' are blank, will not be considered.
If 'CREDIT ITEM' is not entered, default value '0' will be taken.
If 'Calc Field' is not entered, default value 'N' will be taken.
MAX ITEM LIMIT IN EACH EXCEL FILE IS 1000
NIT SCHEDULE FOR CONSTRUCTION OF GOVT. GIRLS COLLEGE BUILDING I/C. WATER SUPPLY, SANITERY FITTINGS & ELECTRIFICATION WORK AT GARIABAND, DISTT.-GARIABAND (C.G.) (GARIYABAND DN.).
SERIAL No. Department SOR Year Item Code Description UOM Rate Quantity Amount Ref Serial No CREDIT ITEM (0/1) Calc Field(Y/N) Road Amount 13 noS amount 11 Nos Amount 2 Nos Amount 2 nos Amount Total Qty.
1 PWD PWD BLD 2015 1.2 Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area). sqm 7.2 10200 0 0 N 15
2 PWD PWD BLD 2015 1.1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. In all types of soils. cum 185 1881.86 0 0 N 6.72
3 PWD PWD BLD 2015 1.6.1 Extra for every additional lift of 1.5 m or part thereof. All types of soils cum 26.5 328.65 0 0 N 10080
4 PWD PWD BLD 2015 3.1.3 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size). cum 2970 444.38 0 0 N 29400
5 PWD PWD BLD 2015 3.1.4 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size). cum 3552 15.33 0 0 N 112066.8
6 PWD PWD BLD 2015 3.1.5 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size) cum 4073 8.78 0 0 N 44754.8
7 PWD PWD BLD 2015 2.1.1 Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level. sqm 139 2180.19 5040
8 PWD PWD BLD 2015 2.1.3 Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Window sills, anchor blocks, string course, bends, copings, bed plates and like.. sqm 184 41.85 0 0 N 23604
9 PWD PWD BLD 2015 2.1.5 Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Columns, Pillars, Piers and likes- rectangular or square in shape sqm 297 2857.81 0 0 N 1680
10 PWD PWD BLD 2015 2.1.8 Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Beams, lintels, cantilevers & walls. sqm 202 2202.35 0 0 N 16651.2
11 PWD PWD BLD 2015 2.1.13 Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Weather shade, chhajja, Cornices and mouldings sqm 294 145.05 0 0 N 64320
12 PWD PWD BLD 2015 2.1.7 Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ) sqm 235 3892.03 0 0 N 64320
13 PWD PWD BLD 2015 2.1.15 Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: Stair cases of all types excluding spiral and folded plate type, including risers and landings sqm 230 212.08 0 0 N 3859.2
14 PWD PWD BLD 2015 3.2.1 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). cum 4163 1709.57 0 0 N 2572.8
15 PWD PWD BLD 2015 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: cum 97.5 571.58 0 0 N 7
16 PWD PWD BLD 2015 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: cum 195 512.6437200000001 0 0 N 7
17 PWD PWD BLD 2015 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: cum 292.5 50.94 7
18 PWD PWD BLD 2015 3.12.1 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete: Thermo-Mechanically treated bars FE 415 kg 54.5 184859.91 0 0 N 6.3
19 PWD PWD BLD 2015 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M. cum 65 877.93 0 0 N 7.2
20 PWD PWD BLD 2015 1.19 Providing filling and compacting local earth (from approved source pit) in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete. cum 242 966.2 1
21 PWD PWD BLD 2015 1.18 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete. cum 371 3285.758012499999 8
22 PWD PWD BLD 2015 7.5.3 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: Cement Mortar 1:5 (1 cement : 5 coarse sand) cum 3350 82.41499999999999 34
23 PWD PWD BLD 2015 3.13 Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work. cum 4237 10.210249999999998 0 0 N 800
24 PWD PWD BLD 2015 3.15 Applying a coat of hot bitumen VG-10 using @ 1.7kg/ sqm on damp proof ourse after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. sqm 93.5 204.20499999999993 0 0 N 1062
25 PWD PWD BLD 2015 7.5.3 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: Cement Mortar 1:5 (1 cement : 5 coarse sand) cum 3350 816.42 2898
26 PWD PWD BLD 2015 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: cum 121 340.9340000000001 0 0 N
27 PWD PWD BLD 2015 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: (Second Floor) cum 242 347.604 0 0 N
28 PWD PWD BLD 2015 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: (Terrace) cum 363 81.36 0 0 N 1400
29 PWD PWD BLD 2015 7.11.1 Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level: Cement Mortar 1:3 (1 cement : 3 coarse sand) sqm 394 152 0 0 N
30 PWD PWD BLD 2015 7.12 Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level: sqm 11 90.76 0 0 N 210
31 PWD PWD BLD 2015 7.12 Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level: sqm 22 61.23 2576
32 PWD PWD BLD 2015 7.20 Extra for providing and placing in position hopping 25x1.60 mm or 2 Nos 6mm dia MS bars reinforcement at every third course of half brick masonry. sqm 62.5 151.99 0 0 N 87.5
33 PWD PWD BLD 2015 11.2.4 Providing and making 12mm thick cement plaster of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand) sqm 91.5 6281.97 75
34 PWD PWD BLD 2015 11.3.3 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix : In Cement Mortar 1:5 (1 cement : 5 fine sand) sqm 113 222.4 0 0 N 196.1 196.1 319.1 431
35 PWD PWD BLD 2015 11.3.4 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: In Cement Mortar 1:4 (1 cement : 4 fine sand) sqm 107 4074.02 0 0 N 33.7 28 41.6 56.2
36 PWD PWD BLD 2015 11.13 Extra for plastering done on mouldings, cornices or architraves including neat finish to line and level. sqm 134 258.72 0 0 N 41.6
37 PWD PWD BLD 2015 11.5 Neat Cement punning. sqm 33 182.12 0 0 N 7.5
38 PWD PWD BLD 2015 11.9 Extra for providing and mixing water proofing materials in cement plaster work in proportion as recommended by manufacturer. kg 43.5 1171.54 0 0 N 0.6 0.7
39 PWD PWD BLD 2015 11.41 Providing and fixing chicken mesh weighting not less than 250 gms/ sqm as per IS : specification in the required width with 40mm long steel nails on vertical and horizontal surface near R.C.C. and brick walls junctions including scaffolding and all lead and lifts etc. complete before plastering upto 10mts in height. sqm 86 1856.46 0 0 N 84.9 84.9 259.1 327.1
40 PWD PWD BLD 2015 4.13.1 Grading roof for water proofing treatment with: Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cum 3817 115.72399999999999 0 0 N 1.4 1.6
41 PWD PWD BLD 2015 12.9.1 Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete. Size 300x300mm sqm 692 30 0 0 N 10 20
42 PWD PWD BLD 2015 12.9.2 Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete. Size above 300x300mm sqm 728 102.29 0 0 N 33.36 33.36 80.4 80.4
43 PWD PWD BLD 2015 12.76.1 Providing and laying Glazed Vitrified Floor tiles (GVT/PGVT) with digital print of randaom design with water absorpion less than 0.05% and conforming to IS:15622-2017 of 1st quality of approved make in all colour, shades and size mentioned below (+/- 0.1 mm). laid on 20 mm thick cement mortar 1:4 (1 cement: 4 course sand ) including grouting the joints with white cement and matching pigment etc, complete. Size 600x600 mm thickness 9 to 10 mm sqm 964 3859.74 0 0 N 9.13 9.13 12.42 17.35
44 PWD PWD BLD 2015 12.7.1 Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. Size upto 200x300mm sqm 587 51 6.5 6.5 35 70
45 PWD PWD BLD 2015 12.7.2 Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. Size above 200x300mm sqm 646 256.05 0 0 N 1.56 1.56 4.74 10.9
46 PWD PWD BLD 2015 12.65.2 Providing & laying 60mm thick precast interlocking concrete blocks of approved size (approx 305 sqcm) and shape/ pattern, over 40 mm thick average complete coarse sand bed with joints of 3mm thick filled by fine sand including leveling with surface vibrator, temping and sweeping etc. complete of minimum compressive strength of 250 kg/sq.cm Pigment Coloured (rubber mould) precast interlock concrete blocks sqm 632 69 0 0 N 5.3 10.5
47 PWD PWD BLD 2015 12.17 Extra for fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477 (Type 2) for interior/exterior applications, using 5kg. adhesive per sqm of tile area, in 3mm-6mm thickness in place of cement mortar. sqm 202 161.82 0 0 N 0.7 6.8 10 20
48 PWD PWD BLD 2015 13.6.2 15mm thick Granite work (machine cut, table rubbed & mirror polished) for kitchen platform, vanity counters, window sills and similar locations of required size laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) including joints treated with white cement mixed with matching pigment including rubbing and polishing to edge moulding to give high gloss finish. Granite stone black sqm 3279 260.3 0 0 N 4.4 4.4 9.6 9.6
49 PWD PWD BLD 2015 13.19.2 Extra for providing edge moulding to 15mm thick stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work meter 172 901.2 0 0 N 18 18 14.4 14.4
50 PWD PWD BLD 2015 12.46.2 15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m). Granite stone black sqm 2719 137.94 0 0 N 56.7 74.6 145.2
51 PWD PWD BLD 2015 12.44 Extra for nosing in Granite stone for treads. meter 126 530.4 0 0 N 67.8 67.8 100.8 100.8
52 PWD PWD BLD 2015 12.37.2 Chequerred precast cement concrete tiles 22mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tile including cleaning of joint etc complete on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : Medium shade using approximately. 50% white cement and 50% ordinary cement. sqm 591 737.86
53 PWD PWD BLD 2015 13.4.2 15mm thick Granite work (machine cut, table rubbed & mirror polished) for wall lining (veneer work) in cement mortar 1:3 (1 cement : 3 coarse sand) including pointing with cement mortar 1:2 (1 white cement: 2 marble dust) mixed with matching pigment. (Area of slab should be over 0.5 sqm). Granite stone black sqm 2771 112.28 1 13 11 2 2
54 PWD PWD BLD 2015 13.19.2 Extra for providing edge moulding to 15mm thick stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. direction Granite work sqm 172 320.8
55 PWD PWD BLD 2015 8.151 Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Engineer-in-Charge. meter 346 69.3
56 PWD PWD BLD 2015 8.152.1 Providing and fixing 30mm thick factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5mm thick heat moulded PVC 'C' channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on either side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per Manufacturer’s specification including 3 nos ISI marked stainless steel hinges of size 100x58x1.9 mm complete. (for W.C. and bathroom door shutter). PVC door shutter sqm 2318 22.05
57 PWD PWD BLD 2015 8.12.2 Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges. 35 mm. thick (single leaf) sqm 2005 141.66
58 PWD PWD BLD 2015 8.15 Extra for double leaf shutter instead of single leaf. sqm 52 126.91
59 PWD PWD BLD 2015 9.11 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rails of T-iron 40x40x6mm with 38mm steel pulleys complete with bolts, nuts, locking arrangement stoppers, handles including applying a priming coat of red oxide zinc chromate primer. sqm 3330 11.52
60 PWD PWD BLD 2015 9.47.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing and panelling to be paid for separately For fixed portion kg 331 1886.4
61 PWD PWD BLD 2015 9.47.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing and panelling to be paid for separately For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately). kg 338 1529.52
62 PWD PWD BLD 2015 9.48 Extra for powder coated (minimum 50 micron) aluminium sections instead of anodized. kg 27 2239.86
63 PWD PWD BLD 2015 9.51.2 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness sqm 708 382.38
64 PWD PWD BLD 2015 9.34 Providing and fixing stainless wire gauge of average width of aperture 1.56mm with wire of 0.35mm to existing steel door, window shutter frames with necessary M.S. strip beading etc. complete. sqm 791 190.08
65 PWD PWD BLD 2015 9.15 Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer. kg 67.5 5735.7
66 PWD PWD BLD 2015 9.57.1 Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete. SS Grade 204 kg 467 1123.2
67 PWD PWD BLD 2015 8.132.2 Providing and fixing stainless steel butt hinges IS : 12817 marked with necessary stainless steel screws etc complete. 125x2.5mm (heavy) each 76.5 380
68 PWD PWD BLD 2015 8.137.1 Providing and fixing stainless steel sliding door bolts with 16mm rod, 2.5mm thick flap, necessary stainless steel nuts bolts and screws etc complete. 300mm each 238 54
69 PWD PWD BLD 2015 8.138.1 Providing and fixing stainless steel door latch with 12mm rod, 2.5mm thick flap, necessary stainless steel screws etc complete. 300mm each 92.5 54
70 PWD PWD BLD 2015 8.138.2 Providing and fixing stainless steel door latch with 12mm rod, 2.5mm thick flap, necessary stainless steel screws etc complete. 250mm each 85 28
71 PWD PWD BLD 2015 8.139.1 Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 250 x10mm each 97 124
72 PWD PWD BLD 2015 8.139.2 Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 200 x10mm each 70.5 28
73 PWD PWD BLD 2015 8.141.1 Providing and fixing Stainless steel "D" shape door handles made of 10mm dia rod with necessary stainless steel screws etc complete. 200 mm each 64 124
74 PWD PWD BLD 2015 8.143.2 Providing and fixing stainless steel hanging door stopper with necessary stainless steel screws complete. Double each 65 54
75 PWD PWD BLD 2015 14.25 Providing and laying French sprit polish on new wood work after preparing the surface by rubbing down smooth with sand papers, covering the knots, if isible, applying a coat of wood filler, cleaning the surface, applying 50 or more coats of French spirit polish till the surface gives high gloss. sqm 143 380.8
76 PWD PWD BLD 2015 14.13 Providing and applying 2mm thick ready mix exterior grade approved make putty (like Birla wall care, Alltek Superfine W/R of (NCL), Asian, ICI, Nerolac, J.K. wall putty) on walls to make the surface smooth and even. sqm 94.5 14884.96
77 PWD PWD BLD 2015 14.22.1 Painting on new work (two or more coats) to give an even shade with: Satin synthetic enamel paint sqm 55 582.25
78 PWD PWD BLD 2015 14.11.1 Wall painting with acrylic luxury emulsion (plastic) paint of required shade to give an even shade. On new work (two or more coats) sqm 52.5 10810.94
79 PWD PWD BLD 2015 14.16.1 Painting exterior surface with PREMIUM ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc. complete with: On new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) sqm 74.5 4074.02
80 PWD PWD BLD 2015 10.6 Providing and fixing steel grid for false ceiling made from M.S. rectangular hollow tubes of 50x25x1.25mm (wall thickness) as main runners to be jointed to cross runners of same size by electric arc welding with spacing not exceeding 610x610mm in any direction. The frame to be screwed to the wall using wooden plugs and wood screws of size 50x8mm at an interval of not more than 300mm centre to centre. The grid to be supported using 6mm M.S. hanger bars at 1200mm centre to centre both ways bent, hooked, fixed to existing R.C.C. roof with fastner or to the truss as the case may be and bolted to the grid with the help of suitable M.S. holding cleats, complete. kg 101 418.32
81 PWD PWD BLD 2015 10.63 Providing and fixing 97mm thick Gypsum board partition upto ceiling height consisting of frame work "W" / "U" / "L" sections made of G.I. sheet with zinc coating of grade 120, consisting of floor and ceiling channel 50mm wide having equal flanges of 32mm and 0.55mm thick fixed to the floor and ceiling at the spacing of 610mm centre to centre with dash fastener of 12.5mm diameter 40mm length and the studs 48mm wide having one flange of 34mm and other flange 36mm and 0.55mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610mm centre to centre by 6mm dia bolts and nuts at both ends of partition fixed flush to wall with finish with recommended jointing compound, jointing tape, joint finisher and two coats of primer suitable for board as per manufacture's specification and Direction of Engineer-in-charge all complete. sqm 758 196.56
82 PWD PWD BLD 2015 3.21.2 Providing and fixing in position impregnated fibre board confirming to IS: 1838 in expansion joints, including cost of primer, sealing compound all complete. sqm 768 118.16
83 PWD PWD BLD 2015 3.20 Providing and fixing aluminium strip 1.60 mm thick on expansion joints with iron screws as per design to match the colour, shade of wall treatment. sqm 1397 31.5
84 PWD PWD BLD 2015 18.1.1 Providing and fixing water closet squatting pan (Indian type W.C. pan ), 100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Long pattern W.C. pan of size 580 mm each 2459 8
85 PWD PWD BLD 2015 18.4.1 Providing and fixing vitreous china water closet (European type W.C. pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : White pedestal type each 2882 4
86 PWD PWD BLD 2015 18.9.1 Providing and fixing ISI marked plastic seat with lid for pedestal type W.C. pan complete: White/ black each 620 4
87 PWD PWD BLD 2015 18.17.1 Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : White Size 550x450 mm each 1430 12
88 PWD PWD BLD 2015 18.21.2 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink with drain board as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : 1040x510 mm bowl size 460x410x200 mm each 8539 6
89 PWD PWD BLD 2015 18.25.2 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40 mm dia each 88.5 6
90 PWD PWD BLD 2015 18.29 Providing and fixing 600x450 mm beveled edge 4mm mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. each 599 12
91 PWD PWD BLD 2015 18.10.2 Providing and fixing 15 mm nominal bore uplasticised PVC connection pipe with PTMT nuts and PVC bush of approved quality and colour: 45 CM length each 66.5 102
92 PWD PWD BLD 2015 18.15 Providing and fixing one piece construction white vitreous china squatting plate urinal with an integral rim longitudinal flushing pipe, standard size G.I. flush pipe for back and front flush, C.P. brass coupling complete including cutting and making good the walls and floors etc. wherever required : each 2014 24
93 PWD PWD BLD 2015 18.78.2 Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm each 61 120
94 PWD PWD BLD 2015 18.76.1 Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 75 mm dia pipe. meter 182 418
95 PWD PWD BLD 2015 18.76.2 Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 110 mm dia pipe. meter 267 750
96 PWD PWD BLD 2015 18.77.1.1 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Tee/ Tee with door/ Bend 45°/ Bend 90° 75 mm each 113 160
97 PWD PWD BLD 2015 18.77.1.2 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Tee/ Tee with door/ Bend 45°/ Bend 90° 110 mm each 154 180
98 PWD PWD BLD 2015 18.77.2.2 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Double "Y" with or without door 110 mm each 224 20
99 PWD PWD BLD 2015 18.77.3.2 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Vent covel 110 mm each 44 12
100 PWD PWD BLD 2015 18.77.5 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. "P" trap 110mmx110mm long each 227 9
101 PWD PWD BLD 2015 18.77.6 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Nahani trap 110x75mm each 90.5 80
102 PWD PWD BLD 2015 19.4.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. INTERNAL WORK - EXPOSED ON WALL 15 mm nominal outer dia .Pipes. meter 110 130
103 PWD PWD BLD 2015 19.4.3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. INTERNAL WORK - EXPOSED ON WALL 25 mm nominal outer dia .Pipes. meter 199 150
104 PWD PWD BLD 2015 19.5.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. CONCEALED WORK including cutting chasesand making good the walls etc., 15 mm nominal outer dia .Pipes. meter 133 70
105 PWD PWD BLD 2015 19.5.3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. CONCEALED WORK including cutting chasesand making good the walls etc., 25 mm nominal outer dia .Pipes. meter 213 150
106 PWD PWD BLD 2015 19.6.3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL WORK, 25 mm nominal outer dia .Pipes. meter 165 280
107 PWD PWD BLD 2015 19.6.4 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL WORK, 32 mm nominal outer dia .Pipes. meter 228 180
108 PWD PWD BLD 2015 19.6.6 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL WORK, 50 mm nominal outer dia .Pipes. meter 476 100
109 PWD PWD BLD 2015 19.14.1 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Bib cock (400 grams) each 382 54
110 PWD PWD BLD 2015 19.14.3 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Long body bib cock (500 grams) each 426 18
111 PWD PWD BLD 2015 19.14.5 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Two way bib cock (800 grams) each 708 2
112 PWD PWD BLD 2015 19.14.6 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Stop cock (concealed) (600 grams) each 494 62
113 PWD PWD BLD 2015 19.14.7 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Angle valve for basin mixer and geyser points (450 grams) each 382 1
114 PWD PWD BLD 2015 19.14.14 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Soap dish plate each 163 12
115 PWD PWD BLD 2015 19.14.15 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Shower rose (revolving type) (150mm) each 269 4
116 PWD PWD BLD 2015 19.14.16 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Towel rail (600mm long x 20mm dia) each 338 20
117 PWD PWD BLD 2015 19.14.20 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: CP brass water jet to be fixed in seat cover of WC with flexible connection pipe each 577 4
118 PWD PWD BLD 2015 19.15 Providing and fixing stainless steel drain jali of approved make/quality. each 51 80
119 PWD PWD BLD 2015 19.18.1 Providing and fixing gun metal non- return valve (horizontal type) of approved quality (screwed end) : 25 mm nominal bore each 413 12
120 PWD PWD BLD 2015 19.18.2 Providing and fixing gun metal non- return valve (horizontal type) of approved quality (screwed end) : 32 mm nominal bore each 556 6
121 PWD PWD BLD 2015 19.18.4 Providing and fixing gun metal non- return valve (horizontal type) of approved quality (screwed end) : 50 mm nominal bore each 993 6
122 PWD PWD BLD 2015 19.42 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank litre 7.3 12000
123 PWD PWD BLD 2015 19.47 Constructing masonry Chamber 30x30x50 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design : each 754 10
124 PWD PWD BLD 2015 19.48 Constructing masonry Chamber 60x60x75 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : each 4644 6
125 PWD PWD BLD 2015 20.1.2 Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm diameter meter 262 80
126 PWD PWD BLD 2015 20.1.3 Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 200 mm diameter meter 506 50
127 PWD PWD BLD 2015 20.2.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete 150mm thick as per standard design: 150 mm diameter S.W. pipe meter 436 80
128 PWD PWD BLD 2015 20.2.3 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete 150mm thick as per standard design: 200 mm diameter S.W. pipe meter 508 50
129 PWD PWD BLD 2015 20.31 Providing and constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. each 1709 4
130 PWD PWD BLD 2015 20.3.1 Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with well burnt modular clay bricks crushing strength not less than 35kg/cm2, water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type each 1339 10
131 PWD PWD BLD 2015 20.5.2 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe meter 353 180
132 PWD PWD BLD 2015 20.7.1 Constructing brick masonry manhole with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 ( 1 cement : 4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation in cement concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : each 6703 14
133 PWD PWD BLD 2015 21.2.1.3 Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge beyond 90 metre & upto 150 metre depth below ground level. All types of soil 150 mm dia. meter 371 60
134 PWD PWD BLD 2015 21.2.2.3 Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge beyond 90 metre & upto 150 metre depth below ground level. Rocky strata including Boulders. 150 mm dia. meter 424 236
135 PWD PWD BLD 2015 21.3.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer –in-charge. 150 mm nominal size dia. meter 540 60
136 PWD PWD BLD 2015 21.6.3 Supplying, assembling, lowering and fixing in vertical position in bore well, slotted casing pipe made from ISI marked G.I. pipe (Plain) medium class in 4 to 7 meters length one end fitted with socket as per IS: 1239 (Part- 1&Part-2) 1992 with IVth revision (having slot of size 1.6/3.2 mm), of reputed and approved make, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-incharge 150 mm nominal dia meter 1317 160
137 PWD PWD BLD 2015 21.9 Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. cum 1048 2.4
138 PWD PWD BLD 2015 21.17 Carrying out the resistivity survey by VES method using Schlumberger configuration for locating the proper spot for drilling of tube well within the selected habitation, including photography, interpretation of resistivity data and submission of report in the desired format along with resistivity readings, necessary graph and photographs. (only successful point is payable) Point 1502 2
139 PWD PWD BLD 2015 21.18 Providing and fixing filter of minimum 100 litre capacity for roof top rain water harvesting through tube well consisting of two layered HDPE tank with five layers (each layers of minimum 100 mm) consist of coarse sand, 4mm, 6mm, 8mm & 12 mm gravels with stainless steel wire mesh fixed between each layer with suitable length and sufficient numbers of 110 mm dia PVC pipe pieces in the bottom of tank to support the above layer including fixing of inlet and out let P.V.C. pipe of required diameter upto 2 metre length on each side, Cement Concrete plateform of required size complete as directed by Engineer in charge. (excluding cost of tubewell and inlet and outlet pipe beyond 2 metre) litre 18.5 6000
140 PWD PWD BLD 2015 21.19 Providing and fixing 80-100 mm dia PVC ball valve for inlet/ outlet of rain water harvesting pipe and filter. each 644 6
141 PWD PWD BLD 2015 22.2 Supplying and stacking of good earth at site including royalty, loading, unloading and carriage upto 5 km (earth measured in stacks will be reduced by 20% for payment). cum 201 347.4
142 PWD PWD BLD 2015 22.3 Supplying and stacking sludge at site including royalty, loading, unloading and carriage upto 5 km (sludge measured in stacks will be reduced by 8% for payment). cum 248 173.7
143 PWD PWD BLD 2015 22.4 Supplying and stacking at site well decayed cow dung manure from approved source, including loading, unloading and carriage upto 5 km (manure measured in stacks will be reduced by 8% for payment). cum 236 115.8
144 PWD PWD BLD 2015 22.7 Fine dressing the ground sqm 1.1 1158
145 PWD PWD BLD 2015 22.9 Mixing earth and sludge or manure in proportion specified or directed. cum 11 1947
146 PWD PWD BLD 2015 25.25.1 Providing and planting following herbs in garden including preparation of soil, base plantation, providing and spreading different fertilizers, soil and sand: Hedges like Alife, Dorenta, Tikoma etc each 14 1000
147 PWD PWD BLD 2015 25.25.2 Providing and planting following herbs in garden including preparation of soil, base plantation, providing and spreading different fertilizers, soil and sand: Furn like Arica, China etc (3 year old) each 125 800
148 PWD PWD BLD 2015 25.25.3 Providing and planting following herbs in garden including preparation of soil, base plantation, providing and spreading different fertilizers, soil and sand: Hibiscus (Flower)/ Rose each 26.5 800
149 PWD PWD BLD 2015 25.25.4 Providing and planting following herbs in garden including preparation of soil, base plantation, providing and spreading different fertilizers, soil and sand: Carpet grass (well developed) each 263 2030
150 PWD ELECT 2020 1.7 Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.7.1 Short Point Point 266 94
151 PWD ELECT 2020 1.7.2 Medium Point Point 424 202
152 PWD ELECT 2020 1.7.3 Long Point Point 588 320
153 PWD ELECT 2020 1.8 Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Point 420 5
154 PWD ELECT 2020 1.9 Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Point 216 102
155 PWD ELECT 2020 1.1 Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.10.1 Short Point Point 442 9
156 PWD ELECT 2020 1.10.2 Medium Point Point 659 10
157 PWD ELECT 2020 1.10.3 Long Point Point 922 17
158 PWD ELECT 2020 1.10.4 Extra Long Point I Point 1302 19
159 PWD ELECT 2020 1.11 Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.11.2 Medium Point Point 942 12
160 PWD ELECT 2020 1.11.3 Long Point Point 1350 7
161 PWD ELECT 2020 1.11.4 Extra Long Point I Point 1807 11
162 PWD ELECT 2020 1.11.5 Extra Long Point II Point 2315 18
163 PWD ELECT 2020 1.13 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.13.2 3 X 2.5 sq. mm in 20mm conduit meter 111 1150
164 PWD ELECT 2020 1.13.3 6 X 2.5 sq. mm in 25mm conduit meter 172 1050
165 PWD ELECT 2020 1.13.4 9 X 2.5 sq. mm in 32mm conduit meter 238 970
166 PWD ELECT 2020 1.13.6 3 X 4 sq. mm in 25mm conduit meter 145 350
167 PWD ELECT 2020 1.13.14 6 X 10 sq. mm in 40mm conduit meter 515 270
168 PWD ELECT 2020 1.13.15 6 X 16 sq. mm in 50mm conduit meter 772 155
169 PWD ELECT 2020 5.4 Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 5.4.3 Bell push each 80 5
170 PWD ELECT 2020 5.4.9 Fan regulator (two module size) electronic stepped type moving all rounds each 223 260
171 PWD ELECT 2020 5.4.11 Plug Top (Deluxe type) 3 pin 16 Amps (For power plug). each 85 34
172 PWD ELECT 2020 5.4.18 25/32 amp A.C. Starter switch each 246 34
173 PWD ELECT 2020 5.4.20 Ceiling rose 3 pin 5 amp each 40 230
174 PWD ELECT 2020 5.4.22 Batten/ angle holder each 41 45
175 PWD ELECT 2020 5.4.23 Blanking plate each 28 41
176 PWD ELECT 2020 5.6 Providing and fixing composite unit for computer points having modular type 1 No 6 pin 16 amp socket outlet, 1 No 16 amp switch, 3 Nos 3 pin 6 amp socket outlets, 3 Nos 6 amp switches, suitable G.I. box, base and cover plates, earthing the sockets and switch box including etc. as per specification. each 816 36
177 PWD ELECT 2020 5.7 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as per specification. 5.7.2 Deluxe each 107 10
178 PWD ELECT 2020 5.9 Providing and fixing round/ hexagonal fan box (125mm dia) depth 75mm (max.) with 12mm dia steel bar hook, 1.6mm thick MS sheet cover, in RCC slab etc. as per specification. each 42 260
179 PWD ELECT 2020 6.1 Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, earthing etc. complete as required. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments. 6.1.3 1200 mm sweep each 1697 260
180 PWD ELECT 2020 6.6 Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.6.1 300 mm sweep each 2446 16
181 PWD ELECT 2020 6.8 Supplying, installation, testing and commissioning of following sizes fancy exhaust fan having built in louvers in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.8.2 300 mm sweep each 1270 2
182 PWD ELECT 2020 6.11 Supplying and fixing following sizes of down rod of 15/20mm dia M.S. pipe of thickness 2 mm to ceiling fan including painting with matching colour etc. as per specification. 6.11.2 60 cm long each 40 260
183 PWD ELECT 2020 6.12 Providing and fixing phenolic laminated sheet cover of 180 mm dia 3 mm thick on the fan box etc. as per specification. (If provided at the time of installation of ceiling fan) each 56 260
184 PWD ELECT 2020 6.15 Supplying, installation, testing and commissioning of following LED fitting (luminaries) down lighters in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.15.6 18/20 watt each 868 40
185 PWD ELECT 2020 6.17 Supplying, fixing, testing and commissioning of following LED lamps with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.17.5 12 Watt each 215 10
186 PWD ELECT 2020 6.17.6 15Watt each 249 10
187 PWD ELECT 2020 6.19 Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.19.3 18/20 watt [4 feet] each 443 240
188 PWD ELECT 2020 6.28 Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 6.28. 7 60 watt each 3622 16
189 PWD ELECT 2020 6.28.8 90 watt each 5531 20
190 PWD ELECT 2020 7.11 Providing and fixing porcelain re-wireble fuse carrier and base unit on wooden board including drilling holes on the board, screws, connections etc. as per specification. (Thimbeling shall be paid separately). 7.11.3 63 amps each 162 3
191 PWD ELECT 2020 7.11.6 300 amps each 797 3
192 PWD ELECT 2020 7.16 Providing and making interconnection in cubical panel between BBC and switchgears with following size aluminium strip of length upto 50cm as per specification (To be measured separately for each phase/ neutral). 7.16.1 20x5mm (100 amps) each 78 9
193 PWD ELECT 2020 7.18 Providing and making interconnection in cubical panel between BBC and switchgears with following size copper strip of length upto 50cm as per specification (To be measured separately for each phase/ neutral). 7.18.1 20x3mm (100 amps) each 173 6
194 PWD ELECT 2020 7.18.2 25x5mm (200 amps) each 296 6
195 PWD ELECT 2020 7.19 Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. 7.19.1 Upto 300 mm deep sqm 6818 1.5
196 PWD ELECT 2020 7.19.3 Above 450 mm and upto 600 mm deep sqm 8519 3
197 PWD ELECT 2020 7.21 Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) copper (electric grade) bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 7.21.2 200 amp (25x5mm) meter 2382 3
198 PWD ELECT 2020 7.21.3 300 amp (40x5mm) meter 2659 3
199 PWD ELECT 2020 9.1 Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 9.1.25 4 pole MCCB, 125A, Adjustable Thermal - Magnetic Release, 35KA each 7428 10
200 PWD ELECT 2020 9.1.29 4 pole MCCB, 320A, Adjustable Thermal - Magnetic Release, 35KA each 17683 1
201 PWD ELECT 2020 9.4 Supplying and fixing on surface/ recess prewired horizontal type following way, 415 volts TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete complete with loose wire box, terminal blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as per specification. (But without MCB/ RCCB/ Isolator) 9.4.6 8 way (4 + 24), Double door each 2547 8
202 PWD ELECT 2020 9.10 Supplying and fixing SP MCB, 240 volts, 'B' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.10.1 6 amps to 32 amps each 151 111
203 PWD ELECT 2020 9.11 Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.11.2 amps to 32 amps each 148 96
204 PWD ELECT 2020 9.14 Supplying and fixing TP MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.14.5 63 amps each 996 8
205 PWD ELECT 2020 9.16 Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.16.5 63 amps each 1316 5
206 PWD ELECT 2020 10.9 Providing and fixing metal clad, TP&N 4 pole automatic change over switch unit, 415/500 volts, including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as per specification. 10.9.2 160 amps each 48493 1
207 PWD ELECT 2020 10.14 Providing and fixing 4 pole, 415/500 volts following rating (AC-1 Duty) power contactor in existing starter/ cubical panel including, connections, testing and commissioning etc. as per specification. 10.14.4 100 amps each 7337 1
208 PWD ELECT 2020 10.15 Providing and fixing following rating current transformer in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.15.5 400/5 amps each 341 8
209 PWD ELECT 2020 10.17 Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification. each 94 16
210 PWD ELECT 2020 10.19 Providing and fixing penal mounting digital type ammeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification each 975 4
211 PWD ELECT 2020 10.20 Providing and fixing penal mounting 0-500 volt voltmeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.20.2 Digital type each 835 4
212 PWD ELECT 2020 10.21 Providing and fixing penal mounting selector switch in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.21.1 For voltmeter each 189 4
213 PWD ELECT 2020 10.21.2 For ammeter each 207 4
214 PWD ELECT 2020 10.22 Providing and fixing following Time switch (timer) in existing panel including connection, testing and commissioning as per specification. 10.22.1 Digital type each 1901 1
215 PWD ELECT 2020 12.1 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as per specification and IS Code 3043: 1987(R 2016) Set 3243 7
216 PWD ELECT 2020 12.3 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016) Set 6209 4
217 PWD ELECT 2020 12.4 Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as per specification. meter 77 160
218 PWD ELECT 2020 12.10 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ concealed conduit/ submain wiring/ cable as per specification. meter 53 110
219 PWD ELECT 2020 12.12 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering, excavation and refilling the trench etc. as per specification. meter 36 140
220 PWD ELECT 2020 12.19 Providing maintenance free earthing with following size GI pipe including making bore pit of minimum 150mm dia, providing and laying approved make Earthing Electrode of Pipe-in-Pipe technology as per IS 3043(R 2016) -1987 made of corrosion free G.I. Pipes having outer pipe of 80mm dia and inner pipe of 50mm dia and filling with specified qty highly conductive compound around pipe and above that with soft soil in bore pit complete and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as per specification: 12.19.1 With 3 metre long GI Pipes and 50 kg back filling compound. each 10955 5
221 PWD ELECT 2020 13.1 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate having 4 nos holes for fixing etc. complete as per specification. each 767 5
222 PWD ELECT 2020 13.2 Making jointing of copper tape (with another copper tape, base of the finial or any other metallic object) by reverting, sweating and soldering/ nut bolting of as per specification. each 51 34
223 PWD ELECT 2020 13.3 Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as per specification.(For horizontal run) meter 217 58
224 PWD ELECT 2020 13.4 Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as per specification.(For vertical run) meter 219 75
225 PWD ELECT 2020 13.5 Providing and fixing testing joint, made of 20 mm X 3 mm thick copper strip, 125 mm long, with 4 nos. of tinned brass bolts, nuts, chuck nuts and spring washers etc. complete as per specification. each 93 5
226 PWD ELECT 2020 13.6 Providing and laying copper tape 32 mm X 6 mm from earth electrode directly in ground as per specification. meter 654 60
227 PWD ELECT 2020 14.2 Supplying and laying HDPE pipe of 4kg/cum in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 14.2.1 63 mm outer dia meter 124 730
228 PWD ELECT 2020 14.2.6 160 mm outer dia meter 664 120
229 PWD ELECT 2020 14.3 Supplying and laying following size medium class G.I. pipe in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 14.3.1 50 mm internal dia meter 333 100
230 PWD ELECT 2020 14.5 Supplying and fixing G.I. pipe along with wall or pole/ support with 2 Nos MS clamps for protection of under ground cable in approved manner including bolts and nuts or metal dash fasteners complete as per specification. 14.5.3 50 mm dia meter 403 10
231 PWD ELECT 2020 15.3 Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 15.3.17 3.5 x 150 sq. mm. meter 484 90
232 PWD ELECT 2020 15.3.22 4 x 10 sq. mm. meter 95 230
233 PWD ELECT 2020 15.3.23 4 x 16 sq. mm. meter 103 480
234 PWD ELECT 2020 15.23 Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. . 15.23.18 3½ X 150 sq. mm (45 mm) each 318 8
235 PWD ELECT 2020 15.23.23 4 X 10 sq. mm (22 mm) each 98 30
236 PWD ELECT 2020 15.23.24 4 X 16 sq. mm (22 mm) each 101 94
237 PWD ELECT 2020 19.7 Supply of hot dipped galvanized (in single dip to minimum 75 micron) octogonal pole made of 3mm thick steel grade E-350 sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected, with following minimum specifications with 4 way terminal connector including 3mm thick anchor plate, 4 nos 20mm dia foundation bolts of EN8 grade, and as per IS 2062 & BS EN: 10025. (designed for wind speed upto 180km/hr, IS: 875 Part 3) 19.7.3 8 metre high, dia 135mm at bottom and 90mm at top, base plate size 225x225x16mm, foundation bolts 750mm long each 11853 15
238 PWD ELECT 2020 19.9 Supply and fixing following street light pole bracket on existing pole made out of 50 mm dia MS "B" class pipe welded to 300 mm long MS pole canopy of suitable dia at a angle of 102.50 including having MS triangular stiffner of size 150 X 50 X 5 mm thick, making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy, painting with one coat of approved steel primer etc. as per specification. 19.9.1 Single Over Hang 0.75 metre Long each 963 10
239 PWD ELECT 2020 19.9.5 Double Over Hang 0.75 metre Long each 1355 5
240 PWD ELECT 2020 19.10 Erection of STEEL TUBULAR or "H" BEAM/ ISMB pole in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation and cement concrete collar of size 0.4 metre dia and 0.50 metre height from ground level including excavation and refilling etc. as per specification of length: 19.10.3 5.0 metre to 6.5 metre each 1854 5
241 PWD ELECT 2020 19.11 Erection of GI octogonal/ tubular/conical pole on existing cement concrete foundation having grouted bolts and nuts, aligning in true vertical position as per specification. 19.11.6 8 metre high each 924 15
242 PWD ELECT 2020 19.24 Painting of following height steel tubular poles with two coat of approved colour and shade synthetic enamel paint including cleaning the surface as per specification: 19.24.3 Above 8 metre and upto 10 metre each 265 15
243 PWD ELECT 2020 20.1 Supply and fixing following overhead line accessories. 20.1.1 Stay rod (19/20mm dia 1.8 metre long) with anchor plate 300x300x6.4mm in CC Set 512 5
244 PWD ELECT 2020 20.1.2 Stay wire 7/4.0mm dia kg 39 36
245 PWD ELECT 2020 20.1.6 Bow tightener each 163 6
246 PWD ELECT 2020 23.3 Supplying, installation, testing and commissioning of submersible pump set for water supply system with submersible motor directly coupled to multi-stage submersible pump of specified discharge capacity, head, delivery size in existing bore well including 2 sets of suitable size holding clamps made out of 50 mm X 6 mm MS flat, connection with suitable submersible cable of standard length etc. as per specification. 23.3.3 2.0 HP, single phase each 19805 1
247 PWD ELECT 2020 23.6 Supplying and fixing following dia HDPE pipe PE-80 Grade (8kg/sqcm) in single length in the suction/ delivery line of water supply pump etc. as per specification. 23.6.2 50 mm outer dia meter 118 80
248 PWD ELECT 2020 23.11 Supply, installation, testing and commissioning of 1-3 HP 1 phase submersible motor starter cum control wall/ floor mounted type made out of not less than 1.6 mm thick MS sheet and comprising of following panel mounting switchgears there in including connection inter-connection etc. as per specification. a) Phase indicating lamps with fuses and toggle switches 1 set b) 1/2/3 HP 1 phase DOL starter with over load and no volt relay 1 No c) 25 A "C" curve DPMCB 1 No d) Voltmeter 0-250 V 1 set e) Ammeter 0-10 A 1 set each 4030 1
249 PWD ELECT 2020 23.12 Supplying and fixing M.S. clamp 50 cm long made of 50mmx5mm thick M.S. Flat for holding the pipes and submerable pump set as per specification. each 291 1
250 PWD ELECT 2020 23.13 Supplying and fixing 300 mm dia 2 mm thick M.S. sheet cover with 3 cm edge in two past on tube well bore pipe as per specification each 388 1
251 PWD ELECT 2020 23.14 Supplying, laying and fixing following size submersible cable along with GI/PVC/HDFC pipe line or laid in ground etc as per specification . 23.14.3 .3x4.0 sqmm meter 90 120
252 PWD ELECT 2020 23.15 Supplying and making water proof joint with heat shrinkable joint kit including copper ferrules for following size of 3 core submersible copper conductor cable of 1.1 KV grade as per specification. 23.15.3 3x4.0 sqmm each 264 1
253 PWD ELECT 2020 23.16 Supplying and laying of approved make stainless steel wire rope of 6 mm dia for support of submersible pump set complete with tying to pump set and pump holding clamp. meter 16 80
254 PWD ELECT 2020 30.1 Earth work in all type soil except soft rock / hard rock with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling of excavated soil in trench / pit to ground level complete as per specification. cum 168 85
255 PWD ELECT 2020 31.14 Painting new steel and other metallic surface with red oxide zinc chromide primer paint complete with supply of material labour etc. including preparation of surface. sqm 116 3
256 PWD ELECT 2020 31.15 Painting wood steel and other metallic surface with Aluminium Paint complete with material and labour including preparation of surface. sqm 143 3
Say Rs. :- lakhs
Department Name Code SOR Name SOR UOM Name UOM Code false7361
Bastar Urban Public Transport Society (BSTUPTS) BSTUPTS WRD WRD Percentage %
Bilaspur Urban Public Transport Society (BSPUPTS) BSPUPTS ELECTRIC ELECT Per mile %O
Chhattisgarh Department of Agriculture (CGDA) CGDA PHED PHED1 1000 no. 1000 no.
Chhattisgarh Handicraft Board (CGHCB) CGHCB RES_BUILDING RESBDG 1000No. 1000No.
Chhattisgarh High Court, Bilaspur (CGHC) CGHC PMGSY SOR PMGSY Siemens Per meter A/V
Chhattisgarh Housing Board (CGHB) CGHB NON SOR NS Acre ACR
Chhattisgarh Infotech Promotion Society (CHiPS) CHiPS BRIDGE PWD_BRIDGE Activity unit AU
Chhattisgarh Medical Services Corporation Ltd. (CGMSC) CGMSC PWD BUILDLING PWD BLD Bag BAG
Chhattisgarh Police Housing Corporation Ltd (CGPHC) CGPHC PWD ROAD PWD ROAD Book BK
Chhattisgarh Rajya Beej Evam Krishi Vikas Nigam (CGRBEKVN) CGRBEKVN Box BOX
Chhattisgarh State Civil Supplies Corp. Limited (SCSC) SCSC Gallons per hour (US) BPH
Chhattisgarh State Industrial Development Corporation (CSIDC) CSIDC Bottle BT
Chhattisgarh State Mandi Board (CGSMB) CGSMB Cubic sentimeter /second C3S
Chhattisgarh State Minor Forest Produce-Trading & Development Co-Operative Federation Ltd (CGMFPFED) CGMFPFED Canister CAN
Chhattisgarh State Power Distribution Company Limited (CGSPDCL) CGSPDCL Carton CAR
Chhattisgarh State Power Generation Company Limited (CGSPGCL) CGSPGCL Cubic Centimeter CCM
Chhattisgarh State Power Transmission Company Limited (CGSPTCL) CGSPTCL Cubic decimeter CD3
Chhattisgarh State Warehousing Corporation (CGSWC) CGSWC Centiliter CL
Chhattisgarh Text Book Corporation (CGTBC) CGTBC cm cm
Department of Animal Husbandry and Dairy (DAHD) DAHD Centimeter CM
Department of Home Guard and Civil Defence Chhattisgarh (HGCD) HGCD Square centimeter CM2
Department of Panchayat and Social Welfare (DPSW) DPSW Crate CRT
Department of School Education (DSE) DSE Case CS
Department of Technical Education (DTE) DTE Cu.Mtr. Cu.Mtr.
Directorate of Fisheries (DF) DF cum cum
Durg-Bhilai Urban Public Transport Society (DBUPTS) DBUPTS cum.km cum.km
Food and Drug Administration (FDA) FDA Days DAY
Health Department (HD) HD Degree DEG
Indira Gandhi Krishi Vishwavidyalaya (IGKV) IGKV DFLT DFLT
Korba Urban Public Transport Society (KRBAUPTS) KRBAUPTS Decimeter DM
Koriya Urban Public Transport Society (KRYAUPTS) KRYAUPTS Drum DR
Mineral Resources Department (MRD) MRD Dozen DZ
Naya Raipur Development Authority (NRDA) NRDA EACH EA
Panchayat and Rural Development (PARD) PARD each each
Public Health Engineering Department (PHED) PHED each additional floor each additional floor
Public Works Department (PWD) PWD each cut each cut
Raigarh Urban Public Transport Society (RIGUPTS) RIGUPTS each test each test
Raipur Collectorate (RC) RC each tree guard each tree guard
Raipur Development Authority (RDA) RDA each tree guard each tree guard
Raipur Urban Public Transport Society (RUPTS) RUPTS Enzyme Units / Milliliter EML
Rajnandgaon Urban Public Transport Society (RNDGUPTS) RNDGUPTS Enzyme Units EU
Rural Engineering Services (RES) RES Fluid Ounce US FOZ
Sarguja Urban Public Transport Society (SUPTS) SUPTS Feet FT
State Urban Development Agency (SUDA) SUDA Square foot FT2
Urban Administration and Development Department (UADD) UADD Cubic foot FT3
Water Resources Department (WRD) WRD Gigajoule FY
gram act.ingrd /liter G/L
Gram act.ingrd. GI
Gram /liter GLI
Gram /square meter GM2
Gram/Cubic meter GM3
Gallons per mile (US) GPM
hectare hectare
Joule /kilogram JKG
Kilogram act.ingrd KAI
Kilogram /cubic decimeter KD3
Kilogram/Mol KGM
Kilogram /Second KGS
Kilogram / cubic meter KGV
kg act.ingrd /kg KIK
Kilojoule/kilogram KJK
Kilojoule/Mol KJM
Square kilometer KM2
Kilometer/hour KMH
Kelvin/Minute KMN
Kelvin /Second KMS
Kilonewton per square meter KNM
Kilovoltampere KVA
Liter per 100 km LHK
Liter /Minute LMI
Liter /Molsecond LMS
Liter Per hour LPH
1/square meter M-2
Mol per cubic meter M:M
Megawatt hours M..
Meter /Hour M/H
Mol per liter M/L
Meter /second M/S
Square meter M2
Square meter/Coat M2C
Square meter/second M2S
Cubic meter /Hour M3H
Cubic meter/second M3S
Man-Month Man-Month
Milligram/liter MGL
Milligram /cubic meter MGQ
Square mile MI2
Microsecond MIS
Milliliter act.ingr. MLI
Square millimeter MM2
Cubic millimeter MM3
Millinewton/meter MNM
Miles per gallon (UG) MPG
Millimol per liter MPL
Millipascal seconds MPS
Meter/second squared MS2
Microsiemens per centimeter MSC
Newton/meter NM
Newton/Square millimeter NMM
one RCC jaali tree guard one RCC jaali tree guard
one RCC jaali tree guard one RCC jaali tree guard
P.cumt. P.cumt.
P.Point P.Point
p.sq.mtr p.sq.mtr
P/sq.Mt. P/sq.Mt.
Pascal second PAS
Megavoltampere PCT
per cm height per letter per cm height per letter
per cm height per letter per cm height per letter
per cubic centimeter per cubic centimeter
Per Km. Per Km.
per letter per letter
Per mtr Per mtr
per pouch per pouch
per test per test
per tonne per tonne
per tonne capacity per tonne capacity
per.mtr per.mtr
Parts per billion PPB
Parts per million PPM
Parts per trillion PPT
Number of persons PRS
Pound Per Sq inch PSI
Pint, US liquid PT
Per Ton Per KM PTPK
Quart, US liquid QT
quintal quintal
Gramm/cubic centimeter RHO
RUNNING METRE RMT
Square Meter sqm
Thousand Hours THR
Ton/Cubic meter TOM
DEFAULT UNIT DESCRIPTION XXX
Square Yard YD2
Microgram /liter µGL
Microgram /cubic meter µGQ
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.11 MB
4355648977090759701_152305_9133295183868357873_125601_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
4014750422827202564_200729_NIT.doc
NIT • 0.35 MB
8470782020170329405_200729_Form A.doc
NIT • 0.15 MB
6556751637013690872_200729_Annexure E terms Condition.doc
NIT • 0.04 MB
2155700181134265926_200729_200729 Notice GIRLS COLLEGE GARIYABAND.docx
NIT • 0.04 MB
7898105247757449377_200729_List of Approved Materials.xlsx
BOQ • 0.01 MB
6105216697608231323_200729_BOQ.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .