Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹9.2 L+₹28,311.12 (3.19%)Rejected-AOC 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-AOC Other Than Lowest Bidder | |
| 3 | L3₹10.3 L+₹1.4 L (15.9%)Rejected-AOC BOOTH NO 119 SECTOR 9 PANCHKULA 134109 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134109 | L3 | Rejected-AOC Other Than Lowest Bidder | |
| 4 | L4₹10.8 L+₹1.9 L (21.4%)Rejected-AOC | L4 | Rejected-AOC Other Than Lowest Bidder |
Tender Value
₹13.3 L
EMD Value
₹26,600
Closing Date
15 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, Shimla Hills Jutogh
CWE, Shimla Hills Jutogh, Jutogh Cantt., Shimla-171008
REPAIR/ MAINTENANCE AT HT ELECT SUPPLY SYSTEM AND OTHER CONNECTED WORKS AT MIL STN KALKA UNDER GE JUTOGH
2022_MES_500902_1
CA NO. CWE/JUT-48/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kalka
Please Refer Tender Documents
6 documents required · 6 mandatory
₹500
GE Jutogh
₹26,600
Yes
26 Feb 2022
11 Jan 2022
18 Feb 2022
11 Jan 2022
15 Feb 2022
1 Feb 2022
60 days
Amount
Excavation in trenches in soft/loose soil n.exc 1.5 Mtr deep and n.exc 1.5 mtr wide for laying of HT cable and for other earth work and getting out including dressing/trimming of sides and leveling, grading and ramming of bottom of excavation complete all as specified and directed.
Returning, filling, including leveling , watering and well ramming excavated soil in layers n.exc 25cm thick in trenches after cable have been laid complete all as specified and directed.
Removing of excavated surplus soil obtained from excavation to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr of the starting point complete all as specified and directed .
Cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate set in 1:6 cement mortar as mass filling and coping of pole and strut, stay around the pole etc complete all as specified and directed .
GI tubing light grade 100 mm dia for road crossing along with pole/culvert /drainage for mechanical protection of cable complete all as specified and directed . Note: All items and accessories , bend, joints, nut bolts, clamps etc are incl in quoted rates.
HDPE (DWC) tubing 100 mm dia of pressure rating 6Kgf/Cm2 fixed on poles, walls under floors, laying on surface etc as reqd at site , fixed in replacement and as per direction of Engr-in-Charge. Note: All items and accessories , bend, joints, nut bolts, clamps etc are incl in quoted rates.
XLPE cable insulated screened, PVC bedded galvanized steel strip of wire armored , electric power cable (Heavy duty ) with aluminum conductor 11000 volts grade cross sectional area 95 sqmm 3 core suitable for 11 KV earthed system incl taking down old unsv HT cable complete all as specified and directed.
Danger notice board/plate of 1.6mm thick mild steel sheet , vitreous enameled white with letters, figures , and conventional skull and bone in signal red colour and fixed with MS clamps bolts approved size for HT 25 cm x 20 cm, complete all as specified and directed.
Supply, install, test and commission lightening arrestor suitable for HT 11 KV expulsion type 65 KA 11 KV rating incl complete connections in replacement complete all as specified and directed.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts and wasters,clamps,welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat of red oxide primer and two coats of aluminum paint incl dismantling and taking down old unser complete all as specified and directed.
Pin or Post type insulator vitreous white, brown or green 11000 volts grade of 150 mm dia and 150mm height including one galvanized mild steel spindle with two GI washers and one galvanized nuts bolts, fixed in repair incl dismantling and taking down old insulator complete all as specified and directed.
Straight through joint heat shrinkable 11 KV earthed system suitable for XLPE cable of size 3 x 50-95 Sqmm incl taking down old unsv HT joint complete all as specified and directed. Note: Earth work will be measured and paid separately.
Cable end termination jointing kit HT 11 KV grade earthed system (heat shrinkable) outdoor type complete with jointing material suitable for HT XLPE cable 95 sqmm 3 core 11 KV grade earthed system incl taking down old unsv HT joint complete all as specified and directed.
Loose filling in substations, under poles, under transformers of hard core broken to gauge not exc 25 mm broken stone/boulders incl leveling and spreading lime stone powder under stones complete all as per direction of Engr-in-Charge.
Synthetic insulating mat of thickness not less than 12 mm size 2.0 mtr X 1.0 mtr suitable for system voltage 11 kV and break down voltage 45 kV confirming IS 15652 : 2006 complete all as specified and directed.
Servicing and maint of HT Vacuum Circuit breaker of make Crompton Greaves and HT Panel after taking proper shut down and disconnecting all elctric supply , maint , cleaning,servicing and testing of HT breaker , bus bar, CTs, PTs, IR value, control cables connections, meters connection, tightening and checking of of AC and DC supply, testing of CT and PT , tightening and checking of control wires and other allied works by authorised dealer / service center / representative, removing moisture and dust from HT breaker and inside of HT breaker through CRC and dry cloths , testing of VI leakage with the help of Hi-Pot @ 10 KV, testing of IR value of breaker, testing and checking of operating mechanism, testing and checking of AC and DC supply, testing of opening release and shunt closing , lubricants of all moving parts,testing and operation of On/Off through TNC switch and push button ,checking of anti-pump device, reapir of racking mechanism, earth alignment,tightening of loose connection and allied work at 11 kV substations complete all as specified and directed. Note: (i) Measurment of resistance value, tools , labour, petroleum jelly , dry cloths, nut -boltsare, CRC, washers etc deemed to be included in the quoted rates. (ii) Contractor will provide company authorised dealer/service centre test / representative test report of internal resistance of breaker and operating time. (iii) Unserviceable part or items to be replaced shall be measured and paid separately under relevent item here-in-after.
Calibration/setting of protection devices, Relays with all protection function (overcurrent, Earth fault protection), tripping test of Overcurrent and earth fault realay through primary and secondary injection machine, testing of Auxiliary relay, tripping test through all respected relays and provide report from authorised service dealer/center/representative complete all as specified and directed. Note. (i) All equipments, tools , labour, incl in the quoted rates. (ii) Contractor will provide company authorised dealer/service centre / representative test report of calibration of relay. (iii) Unserviceable part or items to be replaced shall be measured and paid separately under relevent item here-in-after.
Highly HT insulating opaque red coloured ANTI TRACK COATING SPRAY (SPRAY-320 of MOSIL) that forms flexible chemical resistank coating to class H winding for electrical apparatus, in 500 ml spray bottles to protect HT equipments, bus bar, CTs, PTs from current leakage due to moisture complete all as specified and directed.
HT bus bar insulator for HT panel suitable for Crompton greaves VCB Panel model UNIVAC and Siemens VCB panel at 11 KV substations, fixed in replacement complete as per direction of Engr-in-Charge.
Pole assembly (Vacuum Bottle assembly) complete suitable for Crompton greaves/Siemens VCB at 11 KV substations , fixed in replacement complete as per direction of Engr-in-Charge.
Strip heaters 80-100 watt , AC 240 volts from HT/LT panel of substations , fixed in replacement complete as per direction of Engr-in-Charge.
Thermostat from HT/LT panel installed at substations , fixed in replacement complete as per direction of Engr-in-Charge.
TNC switch suitable for Crompton greaves VCB/ ACB at substations , fixed in replacement complete as per direction of Engr-in-Charge.
Ammeter suitable for Crompton greaves VCB/ ACB at substations , fixed in replacement complete as per direction of Engr-in-Charge.
Digital voltmeter suitable for Crompton greaves VCB/ ACB at substations , fixed in replacement complete as per direction of Engr-in-Charge.
LED indicator lamp of different colours (red,green,yellow,white etc) suitable for Crompton greaves at substations , fixed in replacement complete as per direction of Engr-in-Charge.
Current transformer of ratio 100-50/5-5A, Burden 15 VA, Indoor Epoxy cast type, line voltage 11 kV, class 1.0/5P10, 50 Hz, size and model as suitable as existing CTs installed at 11 KV Substation suitable for Crompton greaves/Siemens VCB at 11 KV substations, fixed in replacement complete as per direction of Engr-in-Charge.
Potential transformer (Draw out type) of ratio 11kV/110V, Burden , 3- Phase, Rated voltage 11 kV, Insulation level, 28/75KV(P) class 1.0, 50 Hz, connection STAR / STAR , size and model as suitable as existing PTs installed at 11 KV Substation suitable for Crompton greaves VCB Incomer at 11 KV substations , fixed in replacement complete as per direction of Engr-in-Charge.
Shunt closing coil 24 V /110 V DC /AC suitable for Crompton greaves VCB/ ACB at 11 KV substations , fixed in replacement complete as per direction of Engr-in-Charge.
Geared motor (EL) 220-250 V AC/DC suitable for Crompton greaves VCB/ ACB at 11 KV substations , fixed in replacement complete as per direction of Engr-in-Charge.
Tripping coil 24 V / 110 Volt DC/AC suitable for Crompton greaves VCB at 11 KV substations , fixed in replacement complete as per direction of Engr-in-Charge.
Motor cut off switch suitable for Crompton greaves VCB at 11 KV substations , fixed in replacement complete as per direction of Engr-in-Charge.
PT fuse of capacity 11 KV suitable to fit on exisitng PTs suitable for Crompton greaves VCB at 11 KV substations , fixed in repair complete as per direction of Engr-in-Charge.
HRC fuse of capacity 2 Amps Each suitable for Crompton greaves VCB at 11 KV substations , fixed in replacement complete as per direction of Engr-in-Charge.
Detecting of fault in HT UG cable with fault locator equipment to locate the fault in HT cable of length not less than 50 RM . Note :- (a) The fault which is detected through cable fault locater will only be paid under this item (b) Charges of cable fault locator and DG set including transportation charges deemed to be included in the quoted rate. (c ) Earth fault locator will be provided by the contractor for even single fault and no dealy on this account will be acceptable otherwise penality will levied Rs 1000/- per day. (d) Necessary testing of cable after making joint will be deemed to be including in the cost of relevent item. However necessary earth work cable cutting , joint making Joint will be paid under relevant item.
Cable route indicator made out of MS/CI 10 cm dia disc shaped with embossed letter (LT/HT) fixed to MS angle iron imbeded in ground with PCC 1:3:6 type C1 using 20 mm graded stone aggregate complete all as specified and directed. Note:- (i) Rate of PCC and earth work is incl in quoted rates. (ii) MS angle will be measured and paid separately.
Supply only Tinned copper fuse wire for HT supply from 10 SWG to 45 SWG all as per direction of Engr-in-Charge.
Supply only in replacement of Blue silica gel 4-6 mesh suitable for transformers breather and protect HT/LT panels from moisture as per site requirement complete all as specified and directed.
Non-metal part HV bushing complete with packing for outdoor/indoor/canopy type distribution transformer of capacity upto 400 KVA , fixed in replacement complete all as specified and directed.
HT, brass bush rod of suitable size for outdoor/indoor/canopy type distribution transformer (11 /0.433 kV) of capacity upto 400 KVA , fixed in replacement complete all as specified and directed.
Non-metal part LV bushing with packing for outdoor/indoor/canopy type distribution transformer or servo stablizer of capacity upto 400 KVA , fixed in replacement complete all as specified and directed.
LT bush rod made of brass of suitable size for outdoor/indoor/canopy type distribution transformer or servo stablizer of capacity upto 400 KVA , fixed in replacement complete all as specified and directed.
Top cover gasket of suitable size for outdoor/indoor/canopy type transformer or servo stablizer upto 400 KVA , fixed in replacement complete all as specified and directed.
Preparing surfaces of transformer or servo stablizer of capacity up to 400 KVA by rubbing old paint and applying two coats of spray painting with grey deco paint from outside, , fixed in replacement complete all as specified and directed. Note:- (i) Painting of transformer will be carried out for plinth mounted and pole mounted transformer. Necessary tools and plants shall be arranged by the contractor. (ii) MES No / SM No has to be written with 3" letters on each transformer/servo stablizer after painting with white colour on black background without any extra cost.
Heating, filtration and dehydration of transformer oil as per IS : 10028 (Part-III) 1981, Para 5.2 (obtained from transformer/ servo voltage stablizer with dehydration/ filtration plant to achieve dielectric strength of 40KV at 2.5 mm gap, complete all as specified and directed. Note:- Any damage occurred to transformer during the process of dehydration, shall be made good by the contractor to the entire satisfaction of the Eng-in-charge at his own expenses.
New transformer oil as per IS : 335 (1993) for transformers/servo stablizer installed at various site or in repair for topping up after dehydration to achieve the di electric strength 60 KV at 2.5 mm gap, complete all as specified and directed. Note:- Transformer oil shall be brought at site in sealed container from the original manufacturer and shall be opened in front of Engr-in-charge, Container shall be deposited by the contractor to the deptt, which will be returned after completion of conract.
Breather transparent type suitable for step down distribution transformers of capacity upto 400 KVA, fixed in replacement complete all as per specification and direction of Engr-in-Charge.
M/S Sonu Traders
SHARMA ELECTRICAL ENGINEERS
M/s Shiksha Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .