| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC 12 NANDGAON PO NIGAHI DISTT SINGRAULI MP 486884 | SINGRAULI | MADHYA PRADESH | 486884 | ₹13.2 L Quoted ₹11.2 L | L1 | Accepted-AOC As per approved TCR |
| 2 | L2₹14.2 L+₹3.0 L (26.9%)Rejected-Finance NEW MARKET SINGRAULI DISTT SINGRAULI MP 486889 | SINGRAULI | SINGRAULI | MP | 486889 | ₹14.2 L+₹3.0 L (26.9%) | L2 | Rejected-Finance As per approved TCR |
| 3 | L3₹14.4 L+₹3.1 L (28.0%)Rejected-Finance PLOT NO 17 18 EWS COLONY DISTT SINGRAULI M P PIN 486889 | SINGRAULI | SINGRAULI | MADHYA PRADESH | 486889 | ₹14.4 L+₹3.1 L (28.0%) | L3 | Rejected-Finance As per approved TCR |
| 4 | L4₹18.0 L+₹6.7 L (60.2%)Rejected-Finance | ₹18.0 L+₹6.7 L (60.2%) | L4 | Rejected-Finance As per approved TCR |
| 5 | L5₹18.0 L+₹6.8 L (60.3%)Rejected-Finance AURI BEHIND SAHARA INDIA PO ANPARA DISTT SONEBHADRA UP 231225 | ANPARA | SONEBHADRA | UP | 231225 | ₹18.0 L+₹6.8 L (60.3%) | L5 | Rejected-Finance As per approved TCR |
| Sl No | Description | Qty | Unit | M/S SARCO ENGINEERING WORKS L3 | DUCK CONSTRUCTION COMPANY L1 | KUNWAR & SINHA ENGINEERING WORKS L2 | M/s HARIHAR SINGH ELECTRICALS L5 | RAVI ELECTRICAL AND CIVIL CONSTRUCTION L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply of MS Nut Bolts 5/8 x 3" and 5/8 x 8" | 274 | kg | 90 ₹24,660 | 80 ₹21,920 Lowest | 100 ₹27,400 | 92 ₹25,208 | 100 ₹27,400 |
| 2.00 | Supply of 11 KV disc insulator | 588 | Nos. | 280 ₹1,64,640 Lowest | 300 ₹1,76,400 | 350 ₹2,05,800 | 360 ₹2,11,680 | 325 ₹1,91,100 |
| 3.00 | Supply of hardware for 11 KV disc insulator including ball, socket type complete with galvanized strain, clamp, bolt, nut , wahser etc | 294 | Nos. | 280 ₹82,320 | 280 ₹82,320 | 300 ₹88,200 | 295 ₹86,730 | 250 ₹73,500 Lowest |
| 4.00 | Supply of Pin Insulator 33kV with GI Pin | 288 | No.'s | 400 ₹1,15,200 | 500 ₹1,44,000 | 300 ₹86,400 Lowest | 595 ₹1,71,360 | 400 ₹1,15,200 |
| 5.00 | Supply of Stay Insulator 33kV grade | 116 | No.'s | 70 ₹8,120 | 50 ₹5,800 | 40 ₹4,640 Lowest | 55 ₹6,380 | 95 ₹11,020 |
| 6.00 | Supply of Earth Wire 7/14 SWG(0.206 kg/mtr) | 628 | kg | 90 ₹56,520 | 100 ₹62,800 | 90 ₹56,520 | 85 ₹53,380 Lowest | 95 ₹59,660 |
| 7.00 | Supply of Stay Wire 7/10 SWG | 324 | kg | 90 ₹29,160 | 100 ₹32,400 | 80 ₹25,920 Lowest | 82 ₹26,568 | 100 ₹32,400 |
| 8.00 | Erection of MS tubular pole 11/13/16 mtrs long in cement concrete 1:3:6(01 cement : 03 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, barber wire etc as required | 142 | No.'s | 1,300 ₹1,84,600 | 1,000 ₹1,42,000 Lowest | 2,000 ₹2,84,000 | 2,650 ₹3,76,300 | 2,500 ₹3,55,000 |
| 9.00 | Supplyig and erection of galvanized stay set for for 33 KV overhead line complete with 19/20 mm dia x1.8 meter long stay rod , anchor plate of size 45 cm x 45 cm x7.5 mm thick turn buckle(20mm x600 mm), 07/4.00 mm dia , GI stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 ( (01 cement : 03 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc as required | 116 | No.'s | 2,400 ₹2,78,400 | 1,050 ₹1,21,800 | 1,000 ₹1,16,000 Lowest | 2,800 ₹3,24,800 | 3,500 ₹4,06,000 |
| 10.00 | Erection of double pole 3 wire cross arm for 33 KV overhead line etc as required | 58 | set | 300 ₹17,400 | 150 ₹8,700 | 50 ₹2,900 Lowest | 380 ₹22,040 | 500 ₹29,000 |
Tender Value
₹22.7 L
EMD Value
₹28,500
Closing Date
30 Sept 2025, 12:00 pmClosed
Staff Officer (EM), Bina
Office of Area General Manager Bina Project NCL U.P. 231220
Stringing of two nos of 33kV Overhead Transmission Line for providing power supply from Bina Main Switching Substation to Substation A of M/S Madhucon Construction at Bina Project NCL
2025_NCL_344146_1
B/EM/eTender/2025-26/37 Dt. 16-09-2025
Open Tender
Electrical and Maintenance Works
Item Rate
60 days
Bina Project
Please refer Tender documents.
4 documents required · 4 mandatory
₹28,500
5 Dec 2025
17 Sept 2025
1 Oct 2025
17 Sept 2025
30 Sept 2025
18 Sept 2025
17 Sept 2025 - 24 Sept 2025
Amount
Supply of MS Nut Bolts 5/8 x 3" and 5/8 x 8"
Supply of 11 KV disc insulator
Supply of hardware for 11 KV disc insulator including ball, socket type complete with galvanized strain, clamp, bolt, nut , wahser etc
Supply of Pin Insulator 33kV with GI Pin
Supply of Stay Insulator 33kV grade
Supply of Earth Wire 7/14 SWG(0.206 kg/mtr)
Supply of Stay Wire 7/10 SWG
Erection of MS tubular pole 11/13/16 mtrs long in cement concrete 1:3:6(01 cement : 03 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, barber wire etc as required
Supplyig and erection of galvanized stay set for for 33 KV overhead line complete with 19/20 mm dia x1.8 meter long stay rod , anchor plate of size 45 cm x 45 cm x7.5 mm thick turn buckle(20mm x600 mm), 07/4.00 mm dia , GI stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 ( (01 cement : 03 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc as required
Erection of double pole 3 wire cross arm for 33 KV overhead line etc as required
Fixing of Guarding Brackets/bracing (making of wire net if required as per instruction of EIC)
Fixing of pole top/straight two wire / angle iron /channel iron on in Single Pole
Erection of Pin Insulator 33 Kv with pin
Erection of of Disc Insulator 11KV with hardware
Fixing of Stay / strain insulator 33 KV Grade
Stringing of ACSR / AAAC 148 / 175 sq. mm Conductor
Stringing of Earth /stay Wire 7/16, 7/14, 7/10 SWG
Fixing of PG Clamp / Jumpering
Fixing of top bracket in single pole
Fabrication of MS Channel 100x50x6, M S Angle 50x50x6 (cutting , welding , hole as per requirement ) for dc cross arm , single bracket, top bracket, clamps etc(Cutting and welding electrode will be provided by contractor)
Supply of Al paint and painting of pole and bracket with one coat red oxide and two coat Al. paint and writing feeder no, pole no and voltage grade on pole
Supply and fixing of Danger Boards 8"X6" for 33KV OH line
Supply, Installtion , commisisoing and testing of off load isolator outdorr type with earth switch. Technical specification are as follows: Rated voltage -33 KV, No of phase -3, Design ambeint teemp - 50 C, Type of operation- Mechnical ganged, Rated current 1250 Amp, Short time current for 03 sec- 25 KA, Rated frequency- 50 Hz, Lighting impulse withstand voltage across isolator distance 195 KV and to earth 170 KV, operating mechnaism-isolator-motor & earth switch-manual. Phase spacing-1500 mm, minimum clerance-(a)Phase to Phase - 320 mm(b) Phase to earth -320 mm (c) Sectional clerance- 3000 mm( Considering 10 % Labour Charge)
Survey pegging / jungle cleaning including tree branch cutting and removing it outside away from OHL for taking alignment of OHL and item maintenance
Supply of 33KV grade outdoor termination kit suitable for 3 core X 400 sqmm screened XLPE cables (in nos.)
Mounting/fixing of 33KV grade outdoor termination kit including dressing and formation of cable and handling of prepared pole mounting to the overhead line and jumpering to OH line (in nos.) (Rate is taken as 10% of the cost of the kit)
Laying of XLPE Power Cable 3 core, 400 sq. mm, 33 kV grade of the horizontal formation including excavation, laying of Cable in HUME or Metal Pipe and its refilling by excavated material
Total impact of GST for the purpose of CTC
KUNWAR & SINHA ENGINEERING WORKS (BID ID -1187977)
M/S SARCO ENGINEERING WORKS (BID ID -1187587)
RAVI ELECTRICAL AND CIVIL CONSTRUCTION (BID ID -1188079)
M/s HARIHAR SINGH ELECTRICALS (BID ID -1188070)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .