Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.6 LAccepted-AOC 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | ₹48.6 L Quoted ₹51.8 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹54.3 L+₹2.5 L (4.88%)Rejected-Finance BUNGALOW NO 21 CANTONMENT BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | ₹54.3 L+₹2.5 L (4.88%) | L2 | Rejected-Finance Being 2nd lowest |
Tender Value
Refer Docs
EMD Value
₹97,220
Closing Date
30 Apr 2024, 6:00 pmClosed
MMD PRAVEEN NANDIKATTI GE AF SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
REPAIR AND REPLACEMENT OF EXTERNAL WATER SUPPLY PIPE LINES, CHLORINATION SYSTEM, CLEANING OF WATER STORAGE TANKS AND REPAIR/MAINT TO LIGHTNING PROTECTION SYSTEM, CONVENTIONAL/CHEMICAL EARTHING OF VARIOUS EQUIPMENTS/INSTRUMENTS AT AF STN SARSAWA UNDER
2024_MES_644820_2
8123/SAR-56/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE(AF) SARSAWA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) SARSAWA
₹97,220
Yes
20 Jun 2024
9 Apr 2024
7 May 2024
9 Apr 2024
30 Apr 2024
16 Apr 2024
9 Apr 2024 - 16 Apr 2024
Amount
Excavation in trenches in any type of soil i.e. loose/soft not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in width and getting out complete all as specified and as directed by Engineer-In-Charge.
All as per item No. 1 above but in hard/dense soil/cutting of road/hard standing/breaking of PCC etc.
Returning, filling and including spreading, leveling and watering and well ramming in layers not exceeding 25 cm to achieve desired compactness as directed by Engineer-In-Charge.
Removing of excavated material/soil to a distance not exceeding 50 Mtrs and depositing at a level not exceeding 1.5 Mtr above the starting point all as directed by Engineer-In-Charge.
M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregates) for repairing of valve chamber foundation etc including filling in road cuts/ hard standing etc all as specified and as directed.
M&L for Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6, complete all as specified.
M&L for 10mm thick cement plastering in cement mortar 1:6 on brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed
Attending complaints of no water / leakage of water by removing float valve, water meter, stop cock etc or GI/composite tubing of size upto 50mm bore upto 0.3 mtr length including all GI fittings like elbow, socket, Tee, Nipple, bend, union etc and making new threads as required at site including excavation,return refilling and removing soil & earth work etc. complete all as specified and directed. NOTE : - (i) The cost of GI pipe upto 0.3 mtr and GI fittings shall be included in the quoted rated. (ii) Excavation and earth work required shall be measured and paid seperately. (iii) Complaints of urgent nature will be attended round the clock including Sunday & holiday to restore the water supply. (vi) Dewatering of accumulated water using engine driven pump set etc is deemed to be included in quoted rate. (v) Complaints given to contractor shall be rectified within 24 hrs. (vi) A penality of Rs 500/- per complaint will be charged for not attending the complaints and complete all as specified and directed.d within 48 hours. (vii) Contractor will arrange all the T&P/Diesel pumps for dewatering where ever required.
Taking up/out cast/ Ductile iron water mains including all fittings with spigot and socketed ends or flanged ends including burning out lead joints or dismantling flanged joints for pipe of following bore complete all as specified and directed. Note: (i) Excavation and earth work shall be measured and paid separately. Pipe of 80mm bore
All as per item No. 9 above but Pipe of 100mm bore
All as per item No. 9 above but Pipe of 150mm bore
All as per item No. 9 above but Pipe of 200mm bore
Laying, jointing and testing cast iron/ ductile iron water pipes with flanged end or spigot and socketed ends here-in-before in any length including cleaning, cutting for reducing length as required, jointing as in trenches for following bore in new or old locations. (Excavation, earth work, joints, threading & CI specials shall be measured and paid separately). Pipe of 80 mm bore
All as per item No. 13 above but Pipe of 100mm bore
All as per item No. 13 above Pipe of 150mm bore
Material & labour for laying, jointing and testing Ductile iron water pipes 200mm bore class K-9 conforming to IS 8329, in any length including jointing with push on rubber tyton joints, as in trenches of following bore in new or old locations. (Excavation, earth work & DI specials shall be measured and paid separately. However, the rate of Rubber tyton joints shall be included in the unit rate quoted).
All as per Item Sr No.16 but 150mm bore class K-7 complete all as specified and directed.
All as per Item Sr No.16 but 100mm bore complete all as specified and directed.
Supply Laying, jointing and testing cast iron water pipes with flanged end or spigot and socketed ends in any length including cleaning, cutting for reducing length as required, jointing as in trenches for 80 mm bore in new or old locations. (Excavation, earth work, joints, threading & CI specials shall be measured and paid separately).
Cutting existing cast iron pipe of following bore of any description for insertion of fittings and setting the pipe in proper alignment complete all as specified and directed. (Excavation earth work and fittings shall be measured and separately). Pipe of 80 mm bore
All as per item No. 20 above but Pipe of 100mm bore
All as per item No. 20 above but Pipe of 150mm bore
All as per item No. 20 above but Pipe of 200mm bore
Material and labour of Run lead joints in repair including extracting old lead while removing the old joint to the following bores of water Supply Lines with spigot & socket ends including necessary earth work excavation in soft loose soil up to 1.5 mtr width and 1.5mtr depth returning and filling and well ramming including watering as required complete all as specified and directed by Engr-in-Charge. Note:- (i) The Joints are meant for laying new / old pipe & fittings and where Independent leaking joints to be ordered. (ii) Old lead as retrived may be used by the contractor under this item. Additional lead as required shall be arranged by the contractor. (iii) Excavation and earth work for independent joints shall be measured and paid separately. Pipe of 80mm bore
All as per item No. 24 above but Pipe of 100mm bore
All as per item No. 24 above but Pipe of 150mm bore
All as per item No. 24 above but Pipe of 200mm bore
Run lead joint to the following bore CI pipe with spigot & socket ends complete all as specified & directed. Pipe of 80mm bore
All as per item No. 28 above but Pipe of 100mm bore
All as per item No. 28 above but Pipe of 150mm bore
All as per item No. 28 above but Pipe of 200mm bore
Taking up or down old unsv steel water tubing of following bore from trenches or walls etc. complete all as directed. (Excavation and earth work shall be measured and paid separately). Pipe of 15mm bore
All as per item No. 32 above but Pipe of 20mm bore
All as per item No. 32 above but Pipe of 25mm bore
All as per item No. 32 above but Pipe of 40mm bore
All as per item No. 32 above but Pipe of 50mm bore
All as per item No. 32 above but Pipe of 80mm bore
Supply & Laying, Jointing Galvanized steel water tubing, medium grade of following bore, screwed and socketed joints with and including all required fittings as in trenches, floors, on walls etc complete all as directed. (Excavation and earth work for fixing in old location already considered in items for taking out and for new locations if required the same shall be paid separately). Pipe of 15mm bore
All as per item No. 38 above but Pipe of 20mm bore
All as per item No. 38 above but Pipe of 25mm bore
All as per item No. 38 above but Pipe of 40mm bore
All as per item No. 38 above but Pipe of 50mm bore
All as per item No. 38 above but Pipe of 80mm bore
Supply and fix in replacement gun metal glove or gate valve heavy duty ISI marked class-1 with iron wheel head, screwed both ends for iron pipe of following bore complete all as specified and directed Pipe of 15mm bore
All as per item No. 44 above but Pipe of 20mm bore
All as per item No. 44 above but Pipe of 25mm bore
All as per item No. 44 above but Pipe of 40mm bore
All as per item No. 44 above but Pipe of 50mm bore
Supplying and fixing in replacement cast iron sluice valves ISI marked with hand wheel suitable for pipe of 200 mm bore, both ends flanged rating PN-1.6 with SS spindle including jointing with New MS nuts and bolts, washers and gasket etc all as specified and directed
Supplying and fixing in replacement cast iron sluice valves ISI marked with hand wheel suitable for pipe of 150 mm bore, both ends flanged rating PN-1.0 with SS spindle including jointing with New MS nuts and bolts, washers and gasket etc all as specified and directed
All as per item Sl.No 50 but for pipe of 100 mm bore
All as per item Sl.No 50 but for pipe of 80 mm bore
Construction of masonry pits of following size (internal size) for sluice valves with sub Class 'B' bricks straight or curved or plan exc 6 mtr mean radius built in CM 1:6 PCC 1:3:6 in foundation, 15 mm thick plaster in CM 1:4 on internal faces of walls, 40 mm thick, PCC 1:2:4 in floors including valve pit cover made out of MS sheet 2 mm thick with angle iron 40x40x6 mm frame with fixing hinges, locking arrangement hold fastand handle etc duly painted with two coats of synthtic enamel paint over a coat of red oxide primer including necessary excavation & earth work complete all as specified inclding breaking of existing broken/ damaged valve pit the contractor can utilize retrived serviceable bricks. Size 60x60x60cm
All as per item No. 53 above but Size 90x90x90cm
All as per item No. 53 above but Size 120x120x90cm
Supply and fix Cast iron/ ductile iron fittings of size upto 300 mm bore for spigot and socketed pipes e.g. Bends (any type, radius and angle). Tapers any type (Straight, end, increasing, decreasing or double socket etc). Tee pieces single branch, 'Y' junctions double branches, crosses (all sockets or socket and spigot) collars caps and plugs conforming to Is complete all as specified and directed. (Excavation, earth work, & joints shall be measured and paid separately).
Supply and fixing 'D' joint complete set including nuts/bolts and rubber ring for repair to GI/ CI / DI pipe line of following size complete all as specified. Note:- Exc and earth Work shall be measured and paid separatly. Pipe of 50 mm bore
All as per item No. 57 above but Pipe of 80 mm bore
All as per item No. 57 above but Pipe of 100 mm bore
All as per item No. 57 above but Pipe of 150 mm bore
All as per item No. 57 above but Pipe of 200 mm bore
Materials and labour for drilling & tapping CI/DI/GI water mains of any size ( in position) for branch connection of the internal dia of size 20 mm including supply and fixing plain brass ferrules screwed both end 20mm bore and necessary earth work complete all as specified and directed by Engr-in-charge.
Repair to sluice valve installed at existing line of following bore by opening up, necessary repair comprising replacement of glands, gland packing, gaskets, facing the gate & valve seat, replacement of nut bolts, reassembling and fixing in position & testing complete all as directed. Note: -(i) Necessary arrangements for regulating the water supply in line for the purpose of repair shall be made by contractor at his own expenses. (ii) MS Spindle shall be measured and paid separately in the under mentioned item. Pipe of 80mm bore
All as per item No. 63 above but Pipe of 100mm bore
All as per item No. 63 above but Pipe of 150mm bore
All as per item No. 63 above but Pipe of 200mm bore
Supply and replace MS Spindle in sluice valve complete with nut all as specified and directed. Pipe of 80mm bore
All as per item No. 67 above but Pipe of 100mm bore
All as per item No. 67 above but Pipe of 150mm bore
All as per item No. 67 above but Pipe of 200mm bore
Supply and fixing in replacement Bib Tap size 20mm bore dia of pipes standard PTMT and colour high pressure screwed for iron pipe and fixed with nipple/ elbow and socket if required all as specified and directed.
M&L for valve pit chamber cover in repair with 3mm thick MS sheet cover including angle iron frame 40x40x5mm duly painted with a coat of zinc oxide primer and two coats of synthetic enamel paint with locking arrangement of size upto 1100x1100mm (or any fabrication required at site) with PCC for fixing of the same complete all as specified and directed by Engr-in-charge
Supply only O- tolidine Reagent (OT solution) for chlorination testing of 500 ml bottle complete all as specified and directed
Service and repair of chlorine dosing pump installed in pump house of any make any size complete all as specified and directed by Engr-in-charge. NOTE : Spares replaced shall be measured and paid separately under relevant item as supply only
All as per item No. 74 above but Gear motor complete 230V 50Hz suitable for altoch decrine dosing pump
All as per item No. 74 above but Rotor assembly with bearings brackets & tolerance rings
All as per item No. 74 above but Coil 250V 50Hz
All as per item No. 74 above but Single head feed rate control with shaft
All as per item No. 74 above but Pump head (ferrules 1/4' & duckbill included)
All as per item No. 74 above but Roller assembly
All as per item No. 74 above but Pump tube
All as per item No. 74 above but NRV for dosing pump
Supply & Fix in replacement of FRP hypo-chlorine powder granules solution preparartion cum setting tank capacity 100 Ltrs with lid, port hole, inlet/outlet/drain connection level gauge etc and fitted with 1 phase 0.5HP motor and agitator rod along with wiring complete all as specified and directed
Lifting / taking out the defective submersible pump motor set of any capacity and description / make, any depth from bore well by lifting, chain pulley etc all as required carefully, by disconnecting / dismantling all electric connections, PVC/MS column pipes of size 32/40 mm etc and transporting the defective pump motor set to workshop, lowering the same after cleaning for any blockage /repair/new pump or motor set to the existing location including replacing the rubber packing/ GI nut bolts of the column pipes etc of suitable size where ever required complete all as specified and as directed by Engr-in-charge.
M&L for complete opening of submersible borewell pump set upto 02 HP capacity for repair/ replacement of unserviceable worn out bearing/ worn out unserviceable shaft/ burned out copper winding as per existing gauge, No of turns, varnishing with specified RPM/ worn out strainer/ bush / sleeve /thrust bearing/ thrust bearing lock nut etc., including reassembling and testing as per specified RPM at workshop etc., complete all as specified and as directed. NOTE : (i) The quoted rate shall be inclusive of transportation of pumpset from pump house site to workshop and back to pump house site after necessary repairs. (ii) The quoted rate shall be inclusive of balancing of shaft through lathe work incl welding work if any required as per site requirement, replacement of oil seal, water cap, neck ring, bush, replacement of worn out T bolts, SS nut, bolts, washers etc complete. (iii) The quoted rate shall be inclusive of shaft sleeve of SS, rubber seal etc complete (iv) Winding shall be measured and paid separately (v) Spares replaced shall be measured and paid separately under relevant item as supply only
Supply only rewinding material for submersible bore well motor upto 02 HP capacity
Supply only the following spare parts for submersible Pumpset upto 02 HP capacity Thrust bearing incl bush
All as per item No. 87 above but Repairing of starter stamping
All as per item No. 87 above but CI motor Base
All as per item No. 87 above but Thrust plate with bushes and bearings
All as per item No. 87 above Balancing of Rotar
All as per item No. 87 above CI suction chamber
All as per item No. 87 above GM bush
All as per item No. 87 above GM impeller (The impeller of any No of stages will be measured as Each Job)
Lifting / taking out the defective submersible pump motor set of any capacity and description / make, any depth from bore well by lifting tolls , chain pulley etc all as required carefully, by disconnecting / dismantling all electric connections, column pipes of size 80/100 mm etc and transporting the defective pump motor set to workshop, lowering the same /repaired/ new serviceable submersible pump or motor set to the existing location including replacing the rubber packing/ GI nut bolts of the column pipes etc of suitable size where ever required complete all as specified and as directed by Engr-in-charge.
M&L for complete opening of submersible borewell pump set of 30/35 HP capacity for repair/ replacement of unserviceable worn out bearing/ worn out unserviceable shaft/ burned out copper winding as per existing gauge, No of turns, varnishing with specified RPM/ worn out strainer/ bush / sleeve /thrust bearing/ thrust bearing lock nut etc., including reassembling and testing as per specified RPM at workshop etc., complete all as specified and as directed. NOTE : (i) The quoted rate shall be inclusive of transportation of pumpset from pump house site to workshop and back to pump house site after necessary repairs. (ii) The quoted rate shall be inclusive of balancing of shaft through lathe work incl welding work if any required as per site requirement, replacement of oil seal, water cap, neck ring, bush, replacement of worn out T bolts, SS nut, bolts, washers etc complete. (iii) The quoted rate shall be inclusive of shaft sleeve of SS, rubber seal etc complete (iv) Winding shall be measured and paid separately ( v) Spares replaced shall be measured and paid separately under relevant item as supply only
Supply only rewinding material for submersible bore well motor of 30/35 HP capacity
Supply only the following spare parts for submersible Pumpset of 30/35 HP capacity Thrust bearing incl bush
All as per item No. 98 above but Revolving disc
All as per item No. 98 above but CI connection piece
All as per item No. 98 above but CI upper housing
All as per item No. 98 above but CI lower housing
All as per item No. 98 above but Repairing of starter stamping
All as per item No. 98 above but CI motor Base
All as per item No. 98 above but Thrust plate
All as per item No. 98 above but Balancing of Rotar
All as per item No. 98 above but CI suction chamber
All as per item No. 98 above but CI stage bowl
All as per item No. 98 above but GM bush
All as per item No. 98 above but GM impeller (The impeller of any No of stages will be measured as Each Job
All as per item No. 98 above but CI DOL Piece
All as per item No. 98 above but CI NRV Body
All as per item No. 98 above but Sand guard/cover
Taking out submersible 15/ 20 HP Non clog sewage pumpset from sewage well duly disconnecting electrical/sewage connections along with existing sewage cable, pipe etc and shifting pump set cable and pipe aside for reuse and lowering into sewage well after repair works including initial testing water proof cable jointing, connecting of sewage line, final testing etc compete all as specified and as directed
Complete opening of 15/ 20 HP capacity submersible non clog sewage pump set for repair / replacement of unserviceable worn out bearing / worn out unserviceable shaft / burned out copper winding with suitable, No of turns & varnishing with specified RPM / worn out strainer/ bush/ sleeve/ thrust pad/ thrust bearing/ impeller/ thrust bearing/ lock nut etc including transportation complete all as specified and as directed. NOTE : Spares replaced shall be measured and paid separately under relevant item as supply only.
Supply only impeller for 15/ 20 HP capacity submersible Non clog sewage pumpset
Supply only ball bearing for 15/ 20 HP capacity submersible Non clog sewage pumpset
Supply only rewinding material for 15/ 20 HP capacity submersible Non clog sewage pumpset
Collection of water samples (with and without chlorination) from following bore wells/sumps in sterilized bottles all as per the standard instructions and guidelines of the Chief Water Analyst of Department of water and Sewage examinations from IIT Roorkee, transporting the samples safely and getting the same tested for chemical and bactyeriological tests, with and without chlorination test from the same Institute and report submitted to this office complete all as specified and directed. Pump house No 1
All as per item No. 119 above but Pump house No 2
All as per item No. 119 above but Pump house No 3
All as per item No. 119 above but Pump house No 4 Note : The water samples (with and without chlorination) shall be counted as 01 set of sample.
Disconnecting electric/ water connections and removing centrifugal monoblock/ submersible pumpset upto 02 HP from any type from existing location and transporting pumpset to workshop and back after repair, servicing including replacement of UNSV parts such as pump rubber gasket/ seal, foundation nut bolts etc as required and refixing in its original position, testing and comissioniong complete all as specified and directed.
M & L in repairs for rewinding of motor at Srl item No 123 above of capacity upto 02 HP by means of cutting and removing existing burnt out winding completely cleaning and repair of slots and rewinding with new copper wire of existing gauge and size/ turns, varnishing with insluation, balancing of shaft, incl replacement of UNSV connection plate/ terminal point as required all etc complete assembling the motor complete as per the specified RPM at workshop complete all as specified and directed
S & F in replacement of ball bearing incl bearing housing, O ring, shaft, seal of suitable size of pumpset at srl item No 123 above as per existing of capacity upto 02 HP after taking out broken/ unsv bearing complete all as specified and directed
M&L for rubber gasket joints in flanged end cast iron pipes of following size and fittings complete with welding grinding work and including minimum 3mm thick rubber/fibre gasket and replacement of nuts/bolts/washers complete including dewatering etc all as specified and directed. Pipe of 80mm bore
All as per item No. 126 above but Pipe of 100mm bore
All as per item No. 126 above but Pipe of 150mm bore
All as per item No. 126 above but Pipe of 200mm bore
Material and labour for painting of CI/DI/GI Column pipe/ railing of Over head reserviour of Size 80 to 150 mm dia with different colour red, blue, yellow or any other color by thorougly removing old paint and applying two coat of red oxide and one coat of synthetic enamel exterior paint complete all as specified by Engineer in charge. NOTE : T & P required for painting such as scaffolding and other misc item shall be arrangement of the contractor and the cost thereof shall be included in the unit rate quoted.
S&F in repairs, column GI medium grade pipe 100 mm flanged/screwed medium grade GI pipes with flanged ends, 3 mtr in length laid in trenches / fixed over ground in suction / delivery line including disconnecting the old pipe of size 100mm from any location i.e. water supply / sewage complete all as specified and as directed by Engr-in-charge.
M&L for Power Contractor 3 pole 3 phase Standard coil voltage 240/415 V, 50 HZ, Auxiliary contacts 2 NO+ 2 NC, Current rating 40 Amps, Make :-Legrand/ schinder/ L&T
M&L for Power Contractor 3 pole 3 phase Standard coil voltage 240/415 V, 50 HZ, Auxiliary contacts 2 NO+ 2 NC, Current rating 32 Amps, Make :-Legrand/ schinder/ L&T
M&L for single phase preventer model VSP 2, suitable to be fixed with FASD starter of any capacity for operation of the submerSI-ble pump motor, including taking out old U/S one complete all as directed
S&F Electronic timer type :- ST 100 operating voltage 240/415 Volts, 50 Hz, time delay range 12-120 Sec/ 3-30 Sec suitable o be fixed with FASD starter of any capacity for operation of the submersible pump motor, including taking out old U/S one complete all as directed
S&F in replacement of submersible starter panel for 2.0 Hp pump set single phase 50Hz complete all as specified and as directed by Engineer-in-Charge.
Taking down cement or cement lime plaster any description on brick or stone walls etc., including raking out joints, hacking of keys, scrubbing down with water etc., complete all as specified and directed.
M&L for 15mm thick cement plaster (1:6) on fair faces of brick work or concrete surfaces complete all as specified and directed
M&L for applying two coat of white wash on new wall surface including preparation of surface complete all as specified and directed
Supply only granular type calcium hypo chlorite having under mentioned generic specifications:- (a) Available chlorine - Min 65% by mass, (b) Stability - Max 1/15 loss of chloride on basis of available chloride, (c) Particle size (passing through 1.70mm IS sieve) - Min 99.5% by mass, (d) Water insoluble mattar- Max 6%, (e) Calcium hydroxide - Max 4%, (f) Sodium chloride - Max 15% Note: 1. Calcium hypo chlorite should be dry free flowing and free from lumps. 2. It should not induce substances beyond acceptable limit as given in IS 10500 (2012) in treated and disinfected water. 3. Contractor must be provide original manufacturing's test certificate with Hologram.
S&F in replacement of butterfly valve PN-10 of size 80mm bore fixed in PVC heavy duty pipe complete with flanged end connections with new nuts/bolts etc complete all as specified and as directed by Engineer-in-charge
S&F in replacement of butterfly valve PN-10 of size 100mm bore fixed in PVC heavy duty pipe complete with flanged end connections with new nuts/bolts etc complete all as specified and as directed by Engineer-in-charge
S&F in replacement of butterfly valve PN-10 of size 150mm bore fixed in PVC heavy duty pipe complete with flanged end connections with new nuts/bolts etc complete all as specified and as directed by Engineer-in-charge
S&F in replacement of butterfly valve PN-10 of size 200mm bore fixed in PVC heavy duty pipe complete with flanged end connections with new nuts/bolts etc complete all as specified and as directed by Engineer-in-charge
S&F in replacement of HDPE lowering pipe heavy duty of size 32/40 mm dia complete with safety wire all as specified and as directed.
Supply, connection and testing of submersible cable copper conductor 3 core 1100 Volt grade 6 sq mm nominal cross sectional area including disconnecting the old u/s cable complete all as specified and directed by Engr-in-charge.
Supply, connection and testing of submersible cable copper conductor 3 core 1100 Volt grade 10 sq mm nominal cross sectional area including disconnecting the old u/s cable complete all as specified and directed by Engr-in-charge.
S&F in replacement mild steel bolts with nuts, washer to replace existing bolts of suitable length all as specified and directed.
S&F in replacement of submersible three phase DOL starter panel upto 02 Hp pump set single phase 50Hz complete all as specified and as directed by Engineer-in-Charge. Make:- Havells/BCH/C&S
M&L for opening of pumpset from the installed position, dismantling of pump and motor assembly, complete servicing and cleaning of pumpset and refixing the same to the installed position complete all as directed and specified
Taking out the old unserviceable winding and cleaning the slots of motor, upto 7.5 HP and rewinding the same with and including PVC insulated copper wire of existing gauge ,weight, size etc complete including all insulations, varnishing, heating etc and making all connections & testing to make it functional complete all as directed .
Dismantling the pump of 7.5 HP cleaning, repairing, overhauling replacement of all unserviceable parts, nut, bolts, impellars, coupling, bearing, clutch system, and pump shaft . Re-assembling, commissioning and testing to make it operational/functional complete all as specified and as directed .
M&L for cleaning of swimming pool complete all as specified & directed for the following steps :- (a) Bailing out the dirty/ Muddy water settled at the bottom of swimming pool of size 25 mtr x13.5 mtr & depth 3.10 mtr ( Average depth) by using small submersible pump set/or Mannual Appx Qty of Muddy water 60,000 litre (b) Taking/ lifting out Alge/ Mudd deposited at the bottom of swimming pool by mannual labours & removing outside the swimming pool upto 50 mtr distance.(Appx qty- 01 Cum) (c) Cleaning the Swimming pool theroughly with water( water will bge supplied by Department) & cleaning the bottom, side walls/tiles of pool by using nylon bruses and detergents & non reactive chemicals theroughly including removing dirt/soopy water from the pool/ (Note: Tiles shall be cleaned/ brushed with water and detergents till the dirt and patches on the tiles are removed to the entire satisfaction of Engr-in-Charge. (d) All as per Serial Item No 44(c) above but baby pool of size 8 mtr x 5 mtr & depth 2 feet. (e) All as per Serial Item No 44(c) above but balancing tank(UG Sump) of swimming pool size having water capacity 50 cum Appx quantity of muddy water 10000 ltrs. (f) Taking/ lifting out Alge/ Mudd deposited at the bottom of balancing tank by mannual labours & removing outside the swimming pool upto 50 mtr distance. (Appx qty- 0.5 Cum)
Daily Cleaning of swimming pool bottom and side walls by using suction sweeper fitted with nylon brush all as specified and directed. Note: (a) Suction sweeper including brush will be used which is at swimming pool installation. (b) This job shall be done on daily basis upto the satisfaction of Engr-in-charge. (c) Electricity for suction sweeper will be provided free of cost by department. (d) Repair to suction sweeper including replacement of bolts, nuts, washers and servicing of suction sweeper pump etc., as and when required shall be provided by the contractor without any extra cost to the department. (e) The rate quoted shall be deemed to include the charges for divers for cleaning the side walls of swimming pool for every cleaning.
M&L for Nylon Brush for Suction Sweeper set complete fitted in Aluminium strips of metalicnead for Suction Sweeper complete all as specified and directed.
Supply only Algae Brush SS Bristles
Supply only Reinforced telescopic Handle not less than 8.0 mtr long
Supply only Deep Bag skimmer clip type
Supply and replacement of Nylone rope 20mm dia complete all as directed.
Supply only Water test Kit (CL & PH).
Supply & replacement of Nylon hose pipe 50mm bore, heavy duty complete with clamping of required size, nuts bolts and washers etc complete all as specified and directed.
M&L for Cleaning of Swimming Pool floor/walls by scrubbing the bottom of walls with a 5% Solution of copper sulphate/Diluted HCL Rinsing after about 15 minutes complete all as directed.
Dewatering of sump near swimming pool filter plant of internal dia 5 mtr and 7 mtr depth approx and cleaning by using with a 5% Solution of copper sulphate/Diluted HCL Rinsing after about 15 minutes complete first and then with plain water complete all as specified and diected.
Painting to existing MS pipe, machinery sluice valves, valve pit cover at Swimming Pool (except repaired under respective item of this schedule), jumping/dividing boards handles upper side of waste water with one coat of synthetic enamelled paint including preparation of surface complete all as directed and specified.
Supply and mixing filter alum (crystaline and clear) into Swimming Pool water for ensuring coagulation and trapping of suspended matter and colour in water in controlled manner to maintain PH value in the range of 7.2 to 7.6 @ approx. complete all as directed
Supply and addition of copper sulphate to Swimming Pool water for controlling and accummulation of organic/inorganic material complete all as directed
Supply and addition of Soda Ash in Swimming Pool as per site requirement for controlling the accumulation of slimis, complete all as specified and directed.
S&F in replacement of ISI marked 3 way reflex multiport valve as per matching to existing type & shape with inlet & outlet connections of dia 50mm dia PVC pipes, for sand media filter tank with in built pressure gauge complete with fixing in existing media filter tank complete with all fixing accessories all as specified and as directed by Engineer-in-charge.
M&L following services to overhead reservoirs as follows:- (i) Dewatering the tank. (ii) Removal of left over dirty water and sludge (iii) Cleaning of wall ceiling and floor (iv) Removing of remaining sludge from the floor (v) Treatment of inside tank be exposing UV radiation kill the suspended or floating bacterial remaining in the tank OH RCC reservoir upto 50000 gallons capacity with staging of tank more than 15 mtrs but less than 28 mtrs hight.
All as per item No. 169 above but OH steel reservoirs of 20,000 gallons capacity
Cleaning of static water tank of dia 6.5 m and 5.0 m deep, pumping out the water, removing mud, ulgi silt, foreign particles, scraping of walls, bottom surfaces and washing with water and applying two coats of water proof weather proof paint over putty repair work including painting on all steel frames/jhali, railings etc complete all as directed by Engr- in- charge.
M&L and T&P for dewatering the sewage collection well 6.60 metre dia, by removing all sewage material, mud, silt, ulgi etc including dewatering cleaning upto the floor. scrapping the walls, roof from inside the well and transporting of material to a distance exceeding 4 KM not exceeding 5 KM outside the AF stn complex complete all as specified and as directed.
Taking out old unserviceable strip/wire any type from wall/roof complete all as specified and directed
Supply and fix aluminium strip of size 25x3.15 mm for Earth continuity conductor or main earthing lead fixed to wall/ roof with saddles and fixing screws etc. for roof conductors and down conductors above ground or any other indicated situation complete all as specified and directed. Note:- Two lengths of strips shall be jointed together by overlapping not less than 100 mm both ends through welding/brazing.
Supply and fix copper strip electrolyte grade having purity not less than 99.9 % of size 20x3.15 mm for Earth continuity conductor or main earthing lead fixed wall/ roof with saddles and fixing screws etc. for roof conductors and down conductors above ground or any other indicated situation complete all as specified and directed. Note:- Two lengths of strips shall be jointed together by overlapping not less than 100 mm both ends through welding/brazing.
Supply and fix GI strip of size 32x6 mm for Earth continuity conductor or main earthing lead fixed wall with saddles and fixing screws etc. or laid underground as in grid connection of earthing complete all as specified and directed. Note:- Two lengths of strips shall be jointed together by overlapping not less than 100 mm both ends through welding/brazing.
Supply and fix Earth continuity conductor or main earthing lead fixed to wall on saddles or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed
Taking down old unserviceable single pointed termination rod any type over the roof from PCC block/GI pipe complete all as specified and directed.
Supply and fix single pointed termination aluminium rod 12 mm dia, 300 long on roof top including fixing/fitting of termination rod and over the roof in PCC block/GI pipe and making connection with roof/down conductor with Al strip by proper bolting/brazing etc complete all as specified and directed. Note : PCC and GI pipe shall be measured and paid separately under respective item of sch.
Material and labour for carrying out soil resistivity for earthing at in accordance with IS 3043 : 2018 by wernner's method and issuing a complete report at certain locations within the premises of AF station sarsawa as specified and directed by engineer-in-charge. NOTE : The job to be executed within 1 month of issue of work order.
Dismantling/Taking out old unserviceable earthing any type/size complete all as specified and directed.
Supply and fixing in repair of Earthing with Galvanised steel pipe electrode shall be of medium grade 40 mm dia and 2.5 m in length. Pipe electrode shall be cut tapered at the bottom and is provided with 12 mm dia holes (staggered) at 75 mm centre to centre upto 2 m of length from bottom. The electrode shall be buried directly in ground vertically with its top edge not less than 1.25 m below ground level connected to main earth lead 4.0 sqmm galvanised iron wire by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.2 of MES Schedule pt-I 2009, GI earth lead shall be protected by GI pipe 15 mm dia medium grade and connected to distribution board including excavation in any type of soil,returning filling, disposal of soil, providing alternate layer of charcoal dust and common salt upto top edge of electrode, construction of PCC pit with RCC cover, funnel, including testing on completion complete all as specified and as directed. Note- : (i) GI strip beyond 7.5 metre will be measured and paid sepeartely. (ii) Test report shall be prepared and submitted by the contractor in triplicate duly obtaining signatures of MES JE / AGE & user. (iii) The earth resistance should be less than 5 Ohm.
Material and labour for earthing with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 Metre deep below ground level with top edge of the plate not less than 1.5 Metre below normal ground level connected to galvanised strip 32 x 6 mm by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No. 03 of SSR Part I connected to earthing test point including excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 use 20 mm graded stone aggregate chamber including necessary formwork / mould for fair and even surfaces, precast RCC 1:2:4 type B0 use 12.5 mm graded stone aggregate chamber cover slab, GI funnel, with GI watering pipe 20 mm bore medium graded, wire mesh, protection pipe 40 mm bore GI pipe light grade for earth lead upto 7.50 metre long salt, charcoal including testing complete all as specified and directed by Engineer-in-Charge. Note : (i) GI strip beyond 7.5 metre will be measured and paid sepeartely. (ii) Test report shall be prepared and submitted by the contractor in triplicate duly obtaining signatures of MES JE / AGE & user. (iii) The earth resistance should be less than 5 Ohm.
M&L for bore earthing by digging bore 18 mtr to 20 mtr deep of 200 mm bore (minimum) providing in the bore GI pipe medium grade 40 mm bore (plugged at top with GI plug) copper strip 25 x 3 mm along the pipe upto equipment ( copper strip shall be fixed with the pipe by brass / SS nuts and bolts @ interval of 40 mm each in the entire depth of bore and copper strip 25 x 3 mm from each pit to equipment to be drawn in the GI pipe medium grade 40mm dia as protection of copper strip), in & including charcoal dust and salt filling in alternate layers (each layer shall be 15 cm thick) around the pipe /strip in the entire depth of the bore, PCC 1:2:4 type B1 pit covered with RCC 1:2:4 cover 50mm thick reinforced with XPM weighing 08 Kg/Sqm, CI frame excavation and earth work and other relevant work complete in all respect all as specified and directed by the Engr-in-Charge. Note : (i) Cu strip beyond 7.5 metre will be measured and paid sepeartely. (ii) Test report shall be prepared and submitted by the contractor in triplicate duly obtaining signatures of MES JE / AGE & user. (iii) The earth resistance should be less than 5 Ohm.
M&L for bore holes for chemical eathing upto 200 mm dia to the depth of 3 Meter deep in any type of soil/starta including hard stone boulders by means of any method getting out and disposal of soil to a distance of n exc. 50 m complete all as directed by Engr-in-Charge.
Supply and fix in replacement UL Listed / CPRI tested maintenance free , low carbon copper coated earth rod of 3 Mtr length electrode having diameter of 17.2 mm with with molecular bonded with 99.9% electrolytic copper with minimum coating thickness of 250 microns With thread for linking together additional rod as per site requirement. All relevent tests as per IEC 62561-2. Rod should be tested and certified for Short circuit current withstanding capacity of 20kA Irms from CPRI. Make : OBO/ENNOV/JMV. Earth electrode shall be undergone the following test as per IEC 62561-2 and report of the same to be submitted to Engineer in charge before placing purchase order :- Electrical resistivity test Tensile test Bend test Adhesion test Coating thickness test Salt mist test
Supply and fix universal clamp of SS to connect earth rod with flat conductor complete all as specified and directed
Supply and fix Coupler Suitable for earth rods 17.2mm dia complete all as specified and directed
M&L for earth conductivity enhancing compound shall be tested as per IEC 62651-7, for retaining and maintaining moisture content in the soil, Earth Enhancement Compound is required. Thus such enhancement compounds are supposed to be technically suitable for the condition of use in the field without creating any hazard to the environment as well as the earth electrode, Conductive compound producing low resistance of an earth termination system. Earth enhancing compound shall be so designed and constructed that in normal use their performance is reliable and without danger to persons and the surroundings. The material shall be chemically inert to sub soil and shall not pollute the environment. It shall provide a stable environment in terms of physical and chemical properties and exhibit low resistivity. It shall not be corrosive to the earth electrode itself. The resistivity of the Earth enhancing mineral compound shall be 0.12 Ω-m and should not dissolve, decompose and pollute the environment. 25Kg of compound mixed with required amount of water and sand in slurry form to use with earthing system. Note : Earth enhancing compound shall be undergone tests as per IEC 62561-7 and test report of the same to be submitted to engineer in charge before placing bulk order.
M&L for heavy duty chamber of 300 mm X 300 mm X 200 mm made of Polyethylene / Polypropylene material. Flush Mounted, removable and lockable cover of the earth pit should be able to withstand 5KN(5000Kg). The area inside the inspection chamber should be such that, the UNIVERSAL CLAMP/EBB/Bus bar is not too deep inside the inspection chamber or projecting out of inspection chamber. The chamber should have facility for marking earth resistance and latest testing date by paint at the cover and previous recorded values inside the cover. Inspection chamber should be tested and complied as per IEC 62561-5. Permanent fitting (like a screwed-down plastic label or copper label, or one that can be threaded onto the cable) shall be used at the connection point that is clearly marked with the words: “EARTHING LEAD -DO NOT DISCONNECT” or “EARTHING CONDUCTOR - DO NOT DISCONNECT” all as specified and directed. NOTE FOR SER ITEM NO 13 to 18 : The work is to be carried out through OEM/ authorised vendor only. Proof of which is to be submitted to Engr-in-charge before execution of work. NOTE
Supply & fixing 40 mm dia bore tubing, Light grade,galvanised, with all fitting,screwed,and fixed complete to walls/ceilings and laid in floors for earthing strip protection/ fixing of air terminator rod including taking out old pipe complete all as specified & directed.
Supply & fixing 15 mm dia bore of tubing,Light grade,galvanised, with all fitting,screwed,and fixed complete to walls/ceilings and laid in floors for earthing strip protection/ fixing of air terminator rod including taking out old pipe complete all as specified & directed.
Taking down existing aluminium/copper strip of LA system from roof/wall cleaning, straighting and re-fixing on new insulator complete with fixing arrangements complete all as specified and directed.
Conducting periodical testing of earth pits by standred earth tester after disconnecting earth strip & submitting the records including reconnection complete all as specified and directed. (Note:- (1) Rs.10000 penlty for per month if contrector fail to submit the record duly signed by the concerned users in time for every month in 1st week.
Material and labour for improvement of earthing value upto the desired level as per requirment of equipment by pouring of mixture of salt/charcoal dust/magnesium sulphate/ bentonite in proper ratio including watering complete all as directed by Engineer-in-charge.
S&F high quality copper bolts with nuts, washer to replace and repair existing earthing bolts of suitable length all as specified and directed.
S&F in replacement of galvanized iron steel water tubing 15 mm bore, medium grade for watering to earth pits, laid in trenches, including all fittings and fixtures complete all as specified and as directed.
S&F Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-90gms) complete all as specified and as directed.
S&F 32 mm medium grade PVC pipe ISI marked, burried earthing strip into the ground for proper insulation of building and equipment complete all as directed.
M&L for Brazing of size 40mmx25mmx5mm in copper strip of size 25x3mm at the joint of strip through copper rod of proper size and combination of oxygen acetylene gas cylinder.Joint must be able to withstand high tensile strength and properly done without any defect or without any crack all as specified and directed. Note :- (1) If any crack found in the brazing contractor will do brazing free of cost again.
Dismantling old /broken Earth pit chamber/ PCC block for construction of new earth pit chamber for earthing / PCC block for air termination rod of size as indicated and directed by Engineer-in-charge in (1:3:6) type C1 and plastering 15mm thick in cm (1:4) on internal external surfac of pit/ block including foarm work all as specified and directed.
M&L for RCC pit cover of size as indicated and directed by Engineer-in-charge in (1:2:4) type B1 with reinforced bar of 8mm dia with 100mm C/C including Lifting Handle complete all as specified and directed by Engineer-in-charge.
Taking out tilted earth pit chamber and raming of sand compacting the area and again repositining of Earth pit chamber over a PCC 1:4:8 of 75 mm thick complete all as specified and directed.
M&L for fabrication of earth pit indicator made of MS sheet of 3mm thick (shape as directed ) welded on iron strip of 32mm x 6mm thick x 900mm long (150mm in below GL) dully painted with synthetic enemeled paint over a one coat of redoxide primer complete with writing earthing nomenaclature as specifed by Engineer-in-charge.
M&L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex.head screw complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement insulator/ separator of DMC/SMC material fixing screws on wall/ roof for laying of down/roof conductor complete all as specified and directed by Engineer-in-Charge.
S&F SS 304 nut, bolt,plain & spring washer to replace and repair existing earthing bolts of suitable length all as specified and directed.
prabhave traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .