| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L2₹9.3 L+₹5,770 (0.63%)Rejected-Finance | L2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L3₹9.3 L+₹7,498 (0.81%)Rejected-Finance | L3 | Rejected-Finance BEING L3 BIDDER | |
| 4 | L4₹9.4 L+₹17,897 (1.94%)Rejected-Finance | L4 | Rejected-Finance BEING L4 BIDDER | |
| 5 | L5₹9.4 L+₹19,945 (2.17%)Rejected-Finance | L5 | Rejected-Finance BEING L5 BIDDER |
| Sl No | Description | Qty | Unit | JALAPAHAR HARDWARE L4 | SANJAY KAUSHIK L2 | RAI CONSTRUCTION L3 | Damdoo Bhutia L6 | HIRA SINGH L1 | BIMAL BHATTRAI L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for cleaning of Semi-undeground RCC water reservoir of capacity 30000 gallons by following methods.-
(a) Draining out reserved water by opening drain out valve/ dewatering system.
(b) Removing all scale, dirt, mud inside the tank by using TERBACK G10 Chemical and scrubbing the wall of tank.
(c) Cleaning indide surfaces of the tank with fresh water by high speed jet pump.
(d) First bacteria screening for sterilisation by using TERBACK G5.
(e) Cleaning the floor of the water tank by heavy duty industrial vaccun cleaner.
(f) Second bacteria screening for sterilisation by using UV rays.
(g) Third bacteria screening for sterilisation by using TERBACK G65.
Note: (i) On completion sterilisation certificate to be submitted to the Engg-in-Charge.
(ii) Re-writing the letter not exceeding 25 cm in high as 'Tank cleaned on indicating date,month and year of cleaning with synthetic enamel paint white in colour on black background.
(iii) The quoted unit rate is included for removal of mud, grits & deposits etc properly from site of work. | 1 | Each Job | 46,260 ₹46,260 | 46,200 ₹46,200 | 46,150 ₹46,150 | 55,250 ₹55,250 | 46,000 ₹46,000 Lowest | 46,300 ₹46,300 |
| 2.00 | All as per ser item No. 01 above but for RCC reservoir of capacity 50000 Gallons, complete all as specified and as directed by Engineer-in-charge. | 1 | Each Job | 60,400 ₹60,400 | 60,200 ₹60,200 | 60,100 ₹60,100 | 71,660 ₹71,660 | 60,000 ₹60,000 Lowest | 60,500 ₹60,500 |
| 3.00 | All as per ser item No. 01 above but for Steel Water reservoir of capacity 5000 Gallons, complete all as specified and as directed by Engineer-in-charge. | 2 | Each Job | 21,800 ₹43,600 | 21,700 ₹43,400 | 21,650 ₹43,300 | 31,177 ₹62,354 | 21,500 ₹43,000 Lowest | 21,900 ₹43,800 |
| 4.00 | All as per ser item No. 01 above but for Steel Water reservoir of capacity 14500 Gallons, complete all as specified and as directed by Engineer-in-charge. | 3 | Each Job | 33,300 ₹99,900 | 33,200 ₹99,600 | 33,050 ₹99,150 | 43,410.13 ₹1,30,230.39 | 33,000 ₹99,000 Lowest | 33,400 ₹1,00,200 |
| 5.00 | All as per ser item No. 01 above but for Steel Water reservoir of capacity 20000 Gallons, complete all as specified and as directed by Engineer-in-charge. | 1 | Each Job | 35,700 ₹35,700 | 35,700 ₹35,700 | 35,625 ₹35,625 | 45,640 ₹45,640 | 35,500 ₹35,500 Lowest | 35,800 ₹35,800 |
| 6.00 | M&L for cleaning existing reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, dirt etc complete and applying two coats of alkaline rust converting primer Sika Rust Off 100 or euivalent product of any other make as approved by CEEC/E-in-C branch with brush on the existing rebar for complete wetting of rusted metal surface and allowed to react it for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal / steel for about 5-7 days including surface preparation. Before applying protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth, complete all as specified and as directed by Engineer-in-charge.
Note: Work to be executed by the authorised applicator of manufacturer only. Mild steel surfaces shall be pre-treated by removing loose scale from the surface complete all as specified and directed. | 139 | Sqm | 705 ₹97,995 Lowest | 735 ₹1,02,165 | 730 ₹1,01,470 | 724.04 ₹1,00,641.56 | 725 ₹1,00,775 | 706 ₹98,134 |
| 7.00 | M&L for application of Ferrogard-903 of Sika or euivalent product of any other make as approved by CEEC/E-in-C branch as passivator/ Anti-corrosion coating to the steel reinforcement shall be applied. The material shall be two component, cement based polymer modified two component coating for corrosion protection. The material shall be prepacked and ready to use. It shall be fully compatible with reinstatement methods adopted. This shall include surface preparation and errection of steel porps as required for the application, complete all as specified and as directed by Engineer-in-charge.
Note: Work to be executed by the authorised applicator of manufacturer only. The thickness of coating shall not be less than 150 microns. | 139 | Sqm | 1,310 ₹1,82,090 | 1,300 ₹1,80,700 | 1,300 ₹1,80,700 | 1,337 ₹1,85,843 | 1,280 ₹1,77,920 Lowest | 1,311 ₹1,82,229 |
| 8.00 | M&L for applying two coats pf Sikagard 67 or euivalent product of any other make as approved by CEEC/E-in-C branch, a water based epoxy coating certified for portable water on all over the concrete surface from inside. Apply the first coat by brush allow it to dry for 6-8 hrs and then apply 2nd coat and allow it to cure complete for 24 hrs. The coating shall be applied using brush application. The Thickness after two coating should not be less than 500 microns, complete all as specified and as directed by Engineer-in-charge. | 139 | Sqm | 1,623 ₹2,25,597 | 1,580 ₹2,19,620 Lowest | 1,600 ₹2,22,400 | 1,640 ₹2,27,960 | 1,580 ₹2,19,620 Lowest | 1,625 ₹2,25,875 |
| 9.00 | M&L for pipe line leakage repairing work of any size or specification after disconnecting the near by joint and replacing the GI Fitting, short pieces as required and refixing the same, complete all as specified and as directed by Engineer-in-charge. | 5 | Each Job | 175 ₹875 | 158 ₹790 Lowest | 160 ₹800 | 160 ₹800 | 158 ₹790 Lowest | 176 ₹880 |
| 10.00 | M&L for applying two coats of synthetic enamel paint including preperation of old painted steel surfaces, complete all as specified and as directed by Engineer-in-charge. | 144 | Sqm | 172 ₹24,768 | 158 ₹22,752 Lowest | 160 ₹23,040 | 161 ₹23,184 | 158 ₹22,752 Lowest | 173 ₹24,912 |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
8 Aug 2026, 6:00 pmClosed
AGE I DARJEELING
AGE I DARJEELING JALAPAHAR CANT DIST - DARJEELING
REPAIR/MAINT/IMPV OF EXTERNAL WATER SUPPLY SYSTEM, CLEANING OF WATER RESERVOIRS AND ALLIED WORKS AT JALAPAHAR AREA UNDER AGE I DARJEELING
2026_MES_777303_1
8262/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
JALAPAHAR
AS PER NIT
9 documents required · 9 mandatory
₹500
AGE I DARJEELING
₹18,000
Yes
20 Aug 2026
8 Jul 2026
10 Aug 2026
8 Jul 2026
8 Aug 2026
24 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for cleaning of Semi-undeground RCC water reservoir of capacity 30000 gallons by following methods.-
(a) Draining out reserved water by opening drain out valve/ dewatering system.
(b) Removing all scale, dirt, mud inside the tank by using TERBACK G10 Chemical and scrubbing the wall of tank.
(c) Cleaning indide surfaces of the tank with fresh water by high speed jet pump.
(d) First bacteria screening for sterilisation by using TERBACK G5.
(e) Cleaning the floor of the water tank by heavy duty industrial vaccun cleaner.
(f) Second bacteria screening for sterilisation by using UV rays.
(g) Third bacteria screening for sterilisation by using TERBACK G65.
Note: (i) On completion sterilisation certificate to be submitted to the Engg-in-Charge.
(ii) Re-writing the letter not exceeding 25 cm in high as 'Tank cleaned on indicating date,month and year of cleaning with synthetic enamel paint white in colour on black background.
(iii) The quoted unit rate is included for removal of mud, grits & deposits etc properly from site of work. | 1 | Each Job | - | - |
| 2 | All as per ser item No. 01 above but for RCC reservoir of capacity 50000 Gallons, complete all as specified and as directed by Engineer-in-charge. | 1 | Each Job | - | - |
| 3 | All as per ser item No. 01 above but for Steel Water reservoir of capacity 5000 Gallons, complete all as specified and as directed by Engineer-in-charge. | 2 | Each Job | - | - |
| 4 | All as per ser item No. 01 above but for Steel Water reservoir of capacity 14500 Gallons, complete all as specified and as directed by Engineer-in-charge. | 3 | Each Job | - | - |
| 5 | All as per ser item No. 01 above but for Steel Water reservoir of capacity 20000 Gallons, complete all as specified and as directed by Engineer-in-charge. | 1 | Each Job | - | - |
| 6 | M&L for cleaning existing reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, dirt etc complete and applying two coats of alkaline rust converting primer Sika Rust Off 100 or euivalent product of any other make as approved by CEEC/E-in-C branch with brush on the existing rebar for complete wetting of rusted metal surface and allowed to react it for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal / steel for about 5-7 days including surface preparation. Before applying protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth, complete all as specified and as directed by Engineer-in-charge.
Note: Work to be executed by the authorised applicator of manufacturer only. Mild steel surfaces shall be pre-treated by removing loose scale from the surface complete all as specified and directed. | 139 | Sqm | - | - |
| 7 | M&L for application of Ferrogard-903 of Sika or euivalent product of any other make as approved by CEEC/E-in-C branch as passivator/ Anti-corrosion coating to the steel reinforcement shall be applied. The material shall be two component, cement based polymer modified two component coating for corrosion protection. The material shall be prepacked and ready to use. It shall be fully compatible with reinstatement methods adopted. This shall include surface preparation and errection of steel porps as required for the application, complete all as specified and as directed by Engineer-in-charge.
Note: Work to be executed by the authorised applicator of manufacturer only. The thickness of coating shall not be less than 150 microns. | 139 | Sqm | - | - |
| 8 | M&L for applying two coats pf Sikagard 67 or euivalent product of any other make as approved by CEEC/E-in-C branch, a water based epoxy coating certified for portable water on all over the concrete surface from inside. Apply the first coat by brush allow it to dry for 6-8 hrs and then apply 2nd coat and allow it to cure complete for 24 hrs. The coating shall be applied using brush application. The Thickness after two coating should not be less than 500 microns, complete all as specified and as directed by Engineer-in-charge. | 139 | Sqm | - | - |
| 9 | M&L for pipe line leakage repairing work of any size or specification after disconnecting the near by joint and replacing the GI Fitting, short pieces as required and refixing the same, complete all as specified and as directed by Engineer-in-charge. | 5 | Each Job | - | - |
| 10 | M&L for applying two coats of synthetic enamel paint including preperation of old painted steel surfaces, complete all as specified and as directed by Engineer-in-charge. | 144 | Sqm | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
BOQ_870544.xls
BOQ • 0.56 MB
8262TENDERDOCUMENTS.pdf
Tender Documents • 3.00 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .