Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 LAccepted-AOC 691 INDUSTRIAL AREA PHASE II CHANDIGARH 160 002 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160002 | L1 | Accepted-AOC L1 QUOTED | |
| 2 | L2₹8.2 L+₹76,414 (10.3%)Rejected-AOC 0 0 KAIMGANJ ROAD KUIYA SANT FARRUKHABAD UTTAR PRADESH 209745 | FARRUKHABAD | UTTAR PRADESH | 209745 | L2 | Rejected-AOC L2 QUOTED | |
| 3 | L3₹8.5 L+₹1.0 L (14.1%)Rejected-AOC 5021 1 CAT III MODERN HOUSING COMPLEX MANIMAJRA CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | L3 | Rejected-AOC L3 QUOTED | |
| 4 | L4₹11.8 L+₹4.4 L (59.0%)Rejected-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L4 | Rejected-AOC L4 QUOTED | |
| 5 | L5₹12.7 L+₹5.2 L (70.7%)Rejected-AOC 363 39KA HASSANGANJ BAWLI KUMAR COMPANY 363 39 KA HASAN GANJ BAWLI SAADAT GANJ LUCKNOW SAADATGANJ | L5 | Rejected-AOC L5 QUOTED |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
31 Mar 2025, 6:00 pmClosed
GE AF Chandigarh
GE AF Chandigarh, Air Force Station, Chandigarh-160047
REPAIR TO WATER SUPPLY DISTRIBUTION SYSTEM OF OFFICERS AND SMQ IN VARIOUS MD ACCN AT SECTOR 28, 31 AND 47 CHANDIGARH UNDER GE (AF) CHANDIGARH.
2025_MES_699983_1
GE(AF)/CHD/T-60/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
Chandigarh
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF Chandigarh
₹30,000
Yes
22 May 2025
3 Mar 2025
7 Apr 2025
3 Mar 2025
31 Mar 2025
17 Mar 2025
3 Mar 2025 - 10 Mar 2025
Amount
Note :The unit rate quoted by the tenderer under Col No (13) of Sch `A’ (BOQ) unless specifically mentioned otherwise such as labour only/fixing only, for all items of works shall be deemed to be including cost of all materials, labour, tools and plants, testing and commissioning of work in position complete as required for entire completion of work.
Excavation in trenches in soft loose soil n. exc. 1.5m deep and n. exc. 1.5m in width and getting out including forming bottom surface to required slope/ gradient for laying cables/ pipes etc. , complete all as specified and directed by Engineer-in- Charge. Note: Excavation shall be done carefully to avoid damage of existing pipe line,cable and protection covers.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the pipe have been laid and tested, complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 meter above the starting point , complete all as specified and directed by Engineer-in-Charge.
Steel water tubing, 15 mm bore medium grade ISI Marked, galvanized inclusive of all fittings such as nipple,bends, Tees, unions, elbows, reducers and sockets etc. laid in trenches in and including taking up or down existing unservicable tubing including all fittings and connections, cleaning for re fixing or removal to store, complete all as specified and directed by Engineer-in-Charge. Note for item No.4 to 6: Fittings & specials as required shall be provided by the contractor. Contractor's rate shall be deemed to include the cost of fittings provided.
All as per item No 4 here in before but Steel water tubing of 20 mm bore , complete all as specified and directed by Engrineer-in-Charge.
All as per item No 4 here in before but Steel water tubing of 25 mm bore , complete all as specified and directed by Engrineer-in-Charge.
Cutting of existing 15 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc for taking out new connection by inserting of all fittings such as nipple,bends, Tees, unions, elbows, reducers and sockets etc, complete all as specified and directed by Engineer-in-Charge.
Cutting of existing 20 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc for taking out new connection by inserting of all fittings such as nipple,bends, Tees, unions, elbows, reducers and sockets etc, complete all as specified and directed by Engineer-in-Charge.
Cutting of existing 25 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc for taking out new connection by inserting of all fittings such as nipple,bends, Tees, unions, elbows, reducers and sockets etc, complete all as specified and directed by Engineer-in-Charge.
Gun metal glove or gate valves, class-II ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 15mm dia in and including taking up or down old unservicable gate valve , complete all as specified and directed by Engineer-in-Charge Note for item No.10 to 12 : Excavation & earthwork shall be measured & paid separately under appropriate item of this BOQ where ever required.
All as per item No 10 here in before but of Gun metal glove or gate valves for 20 mm dia , complete all as specified and directed by Engrineer-in-Charge.
All as per item No 10 here in before but of Gun metal glove or gate valves for 25 mm dia , complete all as specified and directed by Engrineer-in-Charge.
Ball valve high pressure of PTMT with epoxy coated aluminium rod and highdensity plastic ball screwed for 20mm dia iron pipe and fixed (minimum wieght 20mm 210gms) and fixed as in repair, complete all as specified and directed by Engineer-in-Charge.
GI tee suitable for 15mm bore pipe and fixed as in repair, complete all as specified and directed by Engineer-in-Charge.
GI tee suitable for 20 mm bore pipe and fixed as in repair, complete all as specified and directed by Engineer-in-Charge.
GI tee suitable for 25 mm bore pipe and fixed as in repair, complete all as specified and directed by Engineer-in-Charge.
GI union suitable for 20mm bore pipe and fixed as in repair, complete all as specified and directed by Engineer-in-Charge.
GI union suitable for 25mm bore pipe and fixed as in repair, complete all as specified and directed by Engineer-in-Charge.
GI nipple 15mm bore 100mm long and fixed as in repair complete all as specified and directed by Engineer-in-Charge.
GI nipple 20mm bore 100mm long and fixed as in repair complete all as specified and directed by Engineer-in-Charge.
GI nipple 25mm bore 100mm long and fixed as in repair, complete all as specified and directed by Engineer-in-Charge.
GI reducer of size 20/ 15mm bore and fixed as in repair, complete all as specified and directed by Engineer-in-Charge.
GI reducer of size 25/ 20mm bore and fixed as in repair, complete all as specified and directed by Engineer-in-Charge.
GI socket suitable for 15mm bore pipe and fixed as in repair, complete all as specified and directed by Engineer-in-Charge.
GI socket suitable for 20mm bore pipe and fixed as in repair, complete all as specified and directed by Engineer-in-Charge.
GI socket suitable for 25mm bore pipe and fixed as in repair, complete all as specified and directed by Engineer-in-Charge.
Straight plain brass ferrules heavy duty of 15mm bore (or connecting screw), screwed both ends and fixed as in repair, complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete (1:3:6) type C-1 using 40 mm graded mechanically crushed stone aggregates as in mass concrete in making good to damaged portion of road/ hard standing in and including demolition of unreinforced cement concrete in ground floors and paving n.exc 15cm thickness (below or above ground level) and removal of rubbish outside MoD land , complete all as specified and directed by Engineer-in-Charge.
Note :Schedule of credit to be deducted on acceptances of bid.Details of Schedule of credit is given in tender documentse.
R S Enterprises (BID ID -3272690)
M/s APEX ENTERPRISES (BID ID -3267013)
SANJEEV ENTERPRISES (BID ID -3273781)
KUMAR AND COMPANY (BID ID -3274354)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .