| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 LAccepted-AOC | ₹2.2 L | L1 | Accepted-AOC L1 Accepted |
| 2 | L2₹2.6 L+₹40,220 (18.4%)Rejected-AOC | ₹2.6 L+₹40,220 (18.4%) | L2 | Rejected-AOC L2 Rejected |
Tender Value
₹2.6 L
EMD Value
₹3,000
Closing Date
21 Oct 2019, 5:00 pmClosed
SE,EWC, Gorakhpur
Office of the SE, EWC, Gorakhpur
Increasing Capacity of Power Transformer at 33/11 KV S/s Padri bazar and Ranibagh
2019_PVVNV_383987_2
04/EWC(G)/2019-20
Open Tender
Electrical Works
Item Wise
90 days
Gorakhpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
SE,EWC, Gorakhpur
₹3,000
25 Feb 2020
5 Oct 2019
22 Oct 2019
5 Oct 2019
21 Oct 2019
5 Oct 2019
Amount
Detail of material
33 KV. Top channel for cable stand & neutral earthing
11 KV C/J Kit 3X300 mm² XLPE Indoor
11 KV C/J Kit 3X300 mm² XLPE Outdoor
P.G.Clamp for Panther to Panther
Alluminium P.G. T-Connector for Panther
Disc.Fitting B&S type 120KN for Panther
Shifting,loading and carriage of following materials on private truck at store centre Gorakhpur & Un-loading of the same with proper stacking at work site khorabar substation (Distance about 0 to 10 km)
11 KV Cable 300mm² XLPE
ACSR Panther Conductor
Jointing charges of 11 KV “XLPE” C/J kit 3 x 300 indoor/Outdoor type
Laying 11 KV, 3 x300 mm2 XLPE, Power cable from transformer to incoming switch gear in the cable trench. 0.45m wide, 0.90m depth. Providing 150 thickness mm local sand for cushion beneath and 150 mm above the cable (quantity of local sand required 0.375 cubm/m in length). The cable shall be duly protected by brick. On both side of cable by laying bricks vertically and bricks would also be laid horizontally on top of vertically laid bricks along the cable (minimum 18 Nos. per mtr. length are to be laid top and outer side along the cable.
Dismentling of old ACSR Dog conductor & rolling in pieces of 33 KV Bus bar in switchyard as per required specification
Stringing, Sagging & Binding of ACSR Panther conductor of 33 KV Bus bar in switchyard as per required specification of RESSPO Norms.
Dismentling of existing Jumpering and re-jumpering from Bus bar to post insulater by PG Clamp as per required specification of RESSPO Norms.
Grouting of M.S. channel 3.2 mtr long (1 Nos.) for cable stand and welding of M.S. flat (3 Nos.) at equal distance for fastening cable by clamp with nuts and bolts mounting of cable at cable stand and connection of jumpers.
Disconnecting of existing 2 no body and 1 no Neutral earthing safely of existing 5 MVA power transformer earthing for installation of new 10 MVA T/F and re-earthing of new 10 MVA T/F by old earth strip including providing required length of GI Earth strip .The earthing of 10 MVA T/F Included all work completed as per required specification of RESSPO norms.
Dismentling of old Damaged LA & erection of new LA in switchyard as per required specification of RESSPO Norms.
M/s S.B.S. Traders
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .