Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
29 Aug 2020, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Exe Eng PHE Mech Div North Sopore
Exe Eng PHE Mech Div North Sopore
Fixing of rate contract for repairs to electrical equipment
2020_PHE_102002_2
PHE/MDNS/NIT/E-16 of 2020-21
Open Tender
Repair and Maintenance Works
Empanelment
3 days
Baramulla and Bandipore
Please refer Tender documents.
2 documents required · 2 mandatory
₹800
Yes
Exe Eng PHE Mech Div North Sopore
₹26,000
Yes
Exe Eng PHE Mech Div North Sopore
10 Oct 2020
10 Aug 2020
31 Aug 2020
10 Aug 2020
29 Aug 2020
10 Aug 2020
26 Aug 2020
120 days
Providing, fitting and testing of Copper thimbles at site
Providing, fitting and testing of Aluminum thimbles at site
Providing, fitting of below mentioned item for repairs to 25KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Copper wire of specific gauge for fabrication of primary / secondary coil
Bush rod with porcelain insulator and packing
Re-taping /re-insulation of coils
Copper strip
Filtration / dehydration of T-oil
Cost of damaged lamination
Providing, fitting of below mentioned item for repairs to 35KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Copper wire of specific gauge for fabrication of primary / secondary coil
Bush rod with porcelain insulator and packing
Re-taping /re-insulation of coils
Copper strip
Filtration / dehydration of T-oil
Cost of damaged lamination
Providing, fitting of below mentioned item for repairs to 50KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Copper wire of specific gauge for fabrication of primary / secondary coil
Bush rod with porcelain insulator and packing
Re-taping /re-insulation of coils
Copper strip
Filtration / dehydration of T-oil
Cost of damaged lamination
Providing, fitting of below mentioned item for repairs to 75KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Copper wire of specific gauge for fabrication of primary / secondary coil
Bush rod with porcelain insulator and packing
Re-taping /re-insulation of coils
Copper strip
Filtration / dehydration of T-oil
Cost of damaged lamination
Providing, fitting of below mentioned item for repairs to 100KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Copper wire of specific gauge for fabrication of primary / secondary coil
Bush rod with porcelain insulator and packing
Re-taping /re-insulation of coils
Copper strip
Filtration / dehydration of T-oil
Cost of damaged lamination
Providing, fitting of below mentioned item for repairs to 150KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Copper wire of specific gauge for fabrication of primary / secondary coil
Bush rod with porcelain insulator and packing
Re-taping /re-insulation of coils
Copper strip
Filtration / dehydration of T-oil
Cost of damaged lamination
Providing and fitting of plate type Voltage regulator including extraction of damaged one, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
1. 150mmx150mm
2. 225mm x 225mm
3. 200mm x 200mm
4. 250mm x 250mm
Providing and fitting of drum type Voltage regulator including extraction of damaged one, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Providing, fitting and testing of Voltmeters at site
Providing, fitting and testing of Ammeters at site
1. 0-50A with CT ratio of 5/50
2. 0-100A with CT ratio of 5/100
3. 0-150A with CT ratio of 5/150
4. 0-200A with CT ratio of 5/200
5. 0-300A with CT ratio of 5/300
6. 0-400A with CT ratio of 5/400
Providing, fitting and testing of post type drop out set including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Suitable for 25KVA Sub-station
Suitable for 63KVA Sub-station
Suitable for 100KVA Sub-station
Suitable for 250KVA Sub-station
Suitable for 630KVA Sub-station
Providing, fitting and testing of link set including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Suitable for 25KVA Sub-station
Suitable for 63KVA Sub-station
Suitable for 100KVA Sub-station
Suitable for 250KVA Sub-station
Suitable for 630KVA Sub-station
Providing, fitting and testing of submersible copper cables of below mentioned specifications including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of copper cables of below mentioned specifications including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of 3.5 core XLPE aluminum conductor of below mentioned specifications including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of 11KV post type lightening arrestor including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of G.O.D set including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of Cross arms including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Channels 75x40
Angle iron support
U Clamps
Guy-wire with turn buckle
Guy-Insulator
Providing, fitting and testing of ACSR Conductor including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of MCCBs (04 Pole) with breaking capacity of 35KA of approved make as per damaged MCCB at site including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of MCCBs (04 Pole) with breaking capacity of 50KA of approved make as per damaged MCCB at site including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of MCCBs (03 Pole) with breaking capacity of 35KA of approved make as per damaged MCCB at site including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of MCCBs (03 Pole) with breaking capacity of 50KA of approved make as per damaged MCCB at site including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing and fitting of Ball/Thrust bearing (DE & NDE) for different capacity motors and pumps
No. 3206 double groove
No. 5206 double groove
No. 7220BECB
Providing, fitting and testing of On load 04 pole Change over switch of approved make as per damaged change over switch at site including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site.
Providing, fitting and testing of Combined volt-ammeter for MU-G starters
Providing, fitting and testing of 415V Indicating lamps
Yellow
Green
Providing, fitting and testing of 415V Single phase preventor
Providing, fitting and testing of ML contactors for starters
Providing, fitting and testing of Power contactors for FASD starters
Providing, fitting and testing of ML relays
ML1 range 4-6.5
ML1 range 6-10
ML1 range 10-16
Providing, fitting and testing of FASD Panel accessories
Electronic timer 0- 30Sec
Electronic timer 0- 60Sec
Single Phase Preventer (Three phase type )
Overload relay 4A-6A
Overload relay 5A-8A
Overload relay 6A-9A
Overload relay 7A-10A
Overload relay 9A-13A
Overload relay 12A-16A
Overload relay 14A-22A
Overload relay 17A-25A
Overload relay 23A-32A
Overload relay 30A-40A
Overload relay 37A-50A
Overload relay 48A-65A
Overload relay 55A-70A
Overload relay 63A-80A
Overload relay 80A-93A
Overload relay 85A- 105A
Overload relay 80A- 115A
Overload relay 125A- 200A
Overload relay 160A- 250A
Overload relay 200A- 315A
Overload relay 250A- 400A
Overload relay 315A- 500A
Overload relay 400A- 630A
Overload relay 500A- 800A
Overload relay 630A- 1000A
Replacement of damaged 1 Sq mm copper power wiring
Providing, fitting and testing of ATS star Delta starter
Pneumatic timer (on delay/off delay)
Electromagnetic power contactor assembly (10A-250A)
Providing, fitting and testing of Contact points for star/delta starters
Providing, fitting and testing of Terminal block
Providing, fitting and testing of Power contactor for MU-G starters
Providing, fitting and testing of Overload relay/under voltage relay/single phase preventer/Timer for MU-G starters
Providing and fitting of Air Circuit breaker 630 amp Manual Draw out type
Providing, fitting and testing of Motor protection circuit breakers with thermal adjustable ranges from 0-100 amp
0-32 Amp (16 steps)
28-63 Amp (03 steps)
55-100 Amp (03 steps)
Providing and fitting of Water level control relay with capsule modules and wiring 1 Sq mm copper minimum 90 Meters
Providing, fitting of below mentioned item for repairs to 30KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Copper wire of specific gauge for fabrication of primary / secondary coil
Bush rod with porcelain insulator and packing
Re-taping /re-insulation of coils
Copper strip
Filtration / dehydration of T-oil
Cost of damaged lamination
Providing, fitting of below mentioned item for repairs to 40KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Copper wire of specific gauge for fabrication of primary / secondary coil
Bush rod with porcelain insulator and packing
Re-taping /re-insulation of coils
Copper strip
Filtration / dehydration of T-oil
Cost of damaged lamination
Nuts and bolts of different size
Providing, fitting of below mentioned item for repairs to 10KVA to 50KVA Servo Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Replacement of digital micro controlled processor based control card
Replacement of AC syncronous servo motor
Replacement of copper wound motorized auto transformer
Replacement of buck and boost series transformer
Providing, fitting of below mentioned item for repairs to 50KVA to 100KVA Servo Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Replacement of digital micro controlled processor based control card
Replacement of AC syncronous servo motor
Replacement of copper wound motorized auto transformer
Replacement of buck and boost series transformer
Providing, fitting of below mentioned item for repairs to 50KVA to 100KVA Servo Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site.
Replacement of digital micro controlled processor based control card
Replacement of AC syncronous servo motor
Replacement of copper wound motorized auto transformer
Replacement of bick and boost series transformer
Repairs to LED lights at site by way of replacing strips
Erection of MS tubular 9m/11m tilted pole by way of excavation of new trench and concrete bottoming including fitting/fixing of Departmental ACSR conductor on the insulators
Repairs to VT Motor with rating from 10HP to 50HP Dismantling of the VT motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items.
Copper wire used in rewinding the motor.
Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc.
Repairs to VT Motor with rating above 50HP to 150HP) Dismantling of the VT motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items.
Copper wire used in rewinding the motor.
Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc.
Repairs to VT Motor with rating above 150HP to 270HP) Dismantling of the VT motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items.
Copper wire used in rewinding the motor.
Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc.
Repairs to horizontal Motor with rating from 5HP to 50HP Dismantling of the horizontal motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items.
Copper wire used in rewinding the motor.
Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc.
Repairs to horizontal Motor with rating above 50HP to 100HP) Dismantling of the horiontal motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items.
Copper wire used in rewinding the motor.
Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc.
Repairs to submersible Motor with rating from 2HP to 50HP Dismantling of the submersible motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items.
Copper wire used in rewinding the motor.
Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc.
Repairs to submersible Motor with rating from and above 50HP to 75HP Dismantling of the submersible motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items.
Copper wire used in rewinding the motor.
Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc.
Repairs to submersible Motor with rating from and above 75HP to 100HP Dismantling of the submersible motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items.
Copper wire used in rewinding the motor.
Associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc.
Replacing of damages illumination single core multistranded copper wiring
Providing and fitting of bimetallic tube terminals Al-Cu for cable thicknesses
Providing, fitting and testing of AC power monitor Proton make after extraction of damaged one
Providing, fitting and testing of VAF Meter, Model 39A, after extraction of damaged one
Providing, fitting and testing of motor protection unit MPU-12, Proton make, after extraction of damaged one
SHAWL ENGINEERING WORKS
M/S HASHMI TRADERS ELECTRO MECHANICAL ENGINEERS
MEER ENGINEERS INDUSTRIAL ESTATE SOPORE
M/S PERFECT ELECTRIC ENGG WORKS
SHAWL ENGINEERING WORKS
MEER ENGINEERS INDUSTRIAL ESTATE SOPORE
M/S HASHMI TRADERS ELECTRO MECHANICAL ENGINEERS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .