| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.7 LAccepted-AOC | ₹64.7 L Quoted ₹66.0 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹66.7 LRejected-Finance H NO 698 SECTOR 10 PANCHKULA HARYANA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | ₹66.7 L | L2 | Rejected-Finance OTHER THAN L1 |
| 3 | L3₹73.8 LRejected-Finance | ₹73.8 L | L3 | Rejected-Finance OTHER THAN L1 |
| 4 | L4₹77.4 LRejected-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹77.4 L | L4 | Rejected-Finance OTHER THAN L1 |
| 5 | L5₹79.9 LRejected-Finance | ₹79.9 L | L5 | Rejected-Finance OTHER THAN L1 |
| Sl No | Description | Qty | Unit | MAMTA ENTERPRISES L4 | M/S JIWAN SINGH L3 | MEELU ENTERPRISES L1 | M/s Kang Builders & Developers L5 | bharat contrectors L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning step down, 11/.433KVA transformer, copper wound, outdoor type complete with standard fittings, plateform mounted, HT 11 KV 3 Phase, Level-2, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage up to ±7.5% with step ± 2.5% including suitable cable entry boxes on LT and bushings on HT side complete in all respects with standard accessories Dyn -11 connection of capacity 315 KVA including taking down of old BER transformer and deposited to MES store yard complete all as specified and directed. Salient features of transformer are as under:-
(a) Transformer shall be oil immerse, naturally self cooled cooper wound, winding core type, MS radiator cool tank compete with first fill of transformer oil plus 5% spare oil as per IS 335 of 1993. the temperature of oil shall not rise more than 40 degree centigrade and 45 degree centigrade of winding. Transformer shall be painted with 2 coats of epoxy paint as per IS-632. Transformer must have ratings of Energy efficient level-2 and energy conservation (Energy conservation Binary Corps) for which necessasry test certificate to be produced by contractor from manufacturer of the transformer and tested as per latest verision of IS codes IS 1180 (Part-I) : 2014 with 1,2,3 or latest amendment.
(b) The following standard accessories shall also be provided :-
(i) Rating and diagram plate (ii) Earthing terminals 2 Nos
(iii) Lifting lugs (iv) Thermometer pocket
(v) Air release hole with plug (vi) Tap changer with locking provision
(vii) Conservator with oil indicator. (viii) C.I. Rollers with locking provision.
(ix) Silica Gel breather complete. (x) MS terminal box both on HT and LT site.
(xi) Oil temperature indicator with maximum & minimum temperature rise indicator.
(xii) Plain breathing device which would not permit ingress of rain water and insects.
(xiii) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug,
(xiv) Oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator)
(xv) Necessary channel on foundation for fixing the transformer with joint and stopper.
(xvi) Transformer drawing shall be got approved by Accepting Officer/representative before placing of order. | 1 | Each Job | 12,39,999 ₹12.4 L | 11,92,222 ₹11.9 L | 11,11,000 ₹11.1 L | 9,50,000 ₹9.5 L | 12,50,000 ₹12.5 L |
| 2.00 | Supply, installation, testing and commissioning step down, 11/.433KVA transformer, copper wound, outdoor type complete with standard fittings, plateform mounted, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage up to ±7.5% with step ± 2.5% including suitable cable entry boxes on LT and bushings on HT side complete in all respects with standard accessories Dyn -11 connection of capacity 63 KVA including taking down of old BER transformer and deposited to MES store yard complete all as specified and directed. Salient features of transformer are as under:-
(a) Transformer shall be oil immerse, naturally self cooled cooper wound, winding core type, MS radiator cool tank compete with first fill of transformer oil plus 5% spare oil as per IS 335 of 1993. the temperature of oil shall not rise more than 40 degree centigrade and 45 degree centigrade of winding. Transformer shall be painted with 2 coats of epoxy paint as per IS-632. Transformer must have ratings of Energy efficient level-2 and energy conservation (Energy conservation Binary Corps) for which necessasry test certificate to be produced by contractor from manufacturer of the transformer and tested as per latest verision of IS codes IS 1180 (Part-I) : 2014 with 1,2,3 or latest amendment.
(b) The following standard accessories shall also be provided :-
(i) Rating and diagram plate (ii) Earthing terminals 2 Nos
(iii) Lifting lugs (iv) Thermometer pocket
(v) Air release hole with plug (vi) Tap changer with locking provision
(vii) Conservator with oil indicator. (viii) C.I. Rollers with locking provision.
(ix) Silica Gel breather complete. (x) MS terminal box both on HT and LT site.
(xi) Oil temperature indicator with maximum & minimum temperature rise indicator.
(xii) Plain breathing device which would not permit ingress of rain water and insects.
(xiii) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug,
(xiv) Oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator)
(xv) Necessary channel on foundation for fixing the transformer with joint and stopper.
(xvi) Transformer drawing shall be got approved by Accepting Officer/representative before placing of order. | 1 | Each Job | 3,79,999 ₹3.8 L | 3,92,222 ₹3.9 L | 3,89,000 ₹3.9 L | 3,60,000 ₹3.6 L | 5,50,000 ₹5.5 L |
| 3.00 | Supply installation testing and commissioning Servo voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type, unbalanced type, copper wound, digital display type, relay free smooth and silent operation with 1 filling of transformer oil (IS 335: 2018 ) & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 1% and speed of correction 50 Volts per second and of capacity 200 KVA including taking down of old BER voltage stablizer and deposited to MES store yard complete all as specified and directed
The following specification./standard accessories shall also be provided :-
(a). Input voltage 340V-460V (b). Out put Voltage 415V + 1% (adjustable )
(c ) Rated frequency 50 Hz (No distortion in wave form
(d) response time not to exceed 10 mile seconds
(e) Sensitivity (+) 1%
(f) Rate of correction more then 6 volts/second for per phase
(g) Class of insulation- A
(h) No load losses less then 0.5% & Full load losses less than 2.5%
(j) Efficiency more than 95%. Protections
(k). Over load/short circuit protection
(l). High/ Low voltage cut off (m) By pass arrangement in case of emergency
(n) Single phase sequence change protection
(o) Duty cycle - continuous 24 x 7
(p) Type of load, 3 phase, unbalanced type
(q) Digital display voltmeter/Ampmeter | 1 | Each | 3,50,000 ₹3.5 L | 5,22,222 ₹5.2 L | 7,11,000 ₹7.1 L | 270 ₹270 | 5,00,000 ₹5 L |
| 4.00 | Excavation in trenches n.exc 1.5 Mtr wide and n.exc 1.5Mtr depth and getting out for errection of LT poles, stay assembly and laying of cable etc in soft/loose soil complete all as specified and directed by Engineer-in-Charge | 376 | Cum | 100 ₹37,600 | 82 ₹30,832 | 99 ₹37,224 | 100 ₹37,600 | 120 ₹45,120 |
| 5.00 | Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cms. thick in soft / loose soil complete all as specified and directed by Engineer-in-Charge | 261 | Cum | 10 ₹2,610 | 12 ₹3,132 | 5 ₹1,305 | 30 ₹7,830 | 30 ₹7,830 |
| 6.00 | Removing of excavated material to a distance n.exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed by Engineer-in-Charge | 115 | Cum | 10 ₹1,150 | 12 ₹1,380 | 5 ₹575 | 30 ₹3,450 | 30 ₹3,450 |
| 7.00 | M&L for sand cushioning in trenches spreading and consolidation 8cm thick before laying the cable & 15 cm of sand after laying the cable complete all as specified | 75 | Cum | 350 ₹26,250 | 222 ₹16,650 | 300 ₹22,500 | 500 ₹37,500 | 400 ₹30,000 |
| 8.00 | Supplying and laying reinforced precast concrete cable cover, class HV, Type 1 , flat, size 300mm x 180mm x 40mm | 5,166 | Each | 22 ₹1.1 L | 20 ₹1.0 L | 55 ₹2.8 L | 30 ₹1.5 L | 20 ₹1.0 L |
| 9.00 | Supply, Laying, jointing, jointing and testing of under ground cables XLPE insulated screened PVC bedded galvanized steel strips armored electric power cable (heavy duty) with aluminium conductor HT 11000 volts grade and cross section area 95 sqmm 3 core conforming to latest IS and ISI marked laid in trenches complete all as directed . | 1,344 | RM | 1,199 ₹16.1 L | 1,000 ₹13.4 L | 977 ₹13.1 L | 930 ₹12.5 L | 820 ₹11.0 L |
| 10.00 | S & F cable route indicators made out of PCC block of size 30 x 80 x10 cm marked "MES HT CABLE" 1/6 of the PCC block to be grounded in ground level completed all as specified and directed. | 44 | Each | 170 ₹7,480 | 120 ₹5,280 | 99 ₹4,356 | 300 ₹13,200 | 20 ₹880 |
Updated dates
Tender Value
₹73.5 L
EMD Value
₹1.4 L
Closing Date
7 Feb 2026, 6:00 pmClosed
Anurag Anand DCWE
HQ 135 WKS ENGRS PIN- 914135 C/O 56 APO
SPL REPAIR FOR ELECTRICAL AND WATER SUPPLY ITEMS AGAINST BER AT TANDA AREA, ADDN/ALTN TO OH HT CONDUCTORS WITH HT UG CABLE FOR CERTAIN AREA OF FEEDER NO 1 AND 4 AND SPL REPAIR / REPLACEMENT OF HT CONDUCTOR UNDER GE (N) AKHNOOR
2026_MES_746951_1
CWE/JA-39/2025-26
Open Tender
Electrical and Maintenance Works
180 days
AKHNOOR
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
GE NORTH AKHNOOR
₹1.4 L
Yes
28 Mar 2026
2 Jan 2026
9 Feb 2026
2 Jan 2026
7 Feb 2026
24 Jan 2026
Supply, installation, testing and commissioning step down, 11/.433KVA transformer, copper wound, outdoor type complete with standard fittings, plateform mounted, HT 11 KV 3 Phase, Level-2, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage up to ±7.5% with step ± 2.5% including suitable cable entry boxes on LT and bushings on HT side complete in all respects with standard accessories Dyn -11 connection of capacity 315 KVA including taking down of old BER transformer and deposited to MES store yard complete all as specified and directed. Salient features of transformer are as under:- (a) Transformer shall be oil immerse, naturally self cooled cooper wound, winding core type, MS radiator cool tank compete with first fill of transformer oil plus 5% spare oil as per IS 335 of 1993. the temperature of oil shall not rise more than 40 degree centigrade and 45 degree centigrade of winding. Transformer shall be painted with 2 coats of epoxy paint as per IS-632. Transformer must have ratings of Energy efficient level-2 and energy conservation (Energy conservation Binary Corps) for which necessasry test certificate to be produced by contractor from manufacturer of the transformer and tested as per latest verision of IS codes IS 1180 (Part-I) : 2014 with 1,2,3 or latest amendment. (b) The following standard accessories shall also be provided :- (i) Rating and diagram plate (ii) Earthing terminals 2 Nos (iii) Lifting lugs (iv) Thermometer pocket (v) Air release hole with plug (vi) Tap changer with locking provision (vii) Conservator with oil indicator. (viii) C.I. Rollers with locking provision. (ix) Silica Gel breather complete. (x) MS terminal box both on HT and LT site. (xi) Oil temperature indicator with maximum & minimum temperature rise indicator. (xii) Plain breathing device which would not permit ingress of rain water and insects. (xiii) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug, (xiv) Oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator) (xv) Necessary channel on foundation for fixing the transformer with joint and stopper. (xvi) Transformer drawing shall be got approved by Accepting Officer/representative before placing of order.
Supply, installation, testing and commissioning step down, 11/.433KVA transformer, copper wound, outdoor type complete with standard fittings, plateform mounted, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage up to ±7.5% with step ± 2.5% including suitable cable entry boxes on LT and bushings on HT side complete in all respects with standard accessories Dyn -11 connection of capacity 63 KVA including taking down of old BER transformer and deposited to MES store yard complete all as specified and directed. Salient features of transformer are as under:- (a) Transformer shall be oil immerse, naturally self cooled cooper wound, winding core type, MS radiator cool tank compete with first fill of transformer oil plus 5% spare oil as per IS 335 of 1993. the temperature of oil shall not rise more than 40 degree centigrade and 45 degree centigrade of winding. Transformer shall be painted with 2 coats of epoxy paint as per IS-632. Transformer must have ratings of Energy efficient level-2 and energy conservation (Energy conservation Binary Corps) for which necessasry test certificate to be produced by contractor from manufacturer of the transformer and tested as per latest verision of IS codes IS 1180 (Part-I) : 2014 with 1,2,3 or latest amendment. (b) The following standard accessories shall also be provided :- (i) Rating and diagram plate (ii) Earthing terminals 2 Nos (iii) Lifting lugs (iv) Thermometer pocket (v) Air release hole with plug (vi) Tap changer with locking provision (vii) Conservator with oil indicator. (viii) C.I. Rollers with locking provision. (ix) Silica Gel breather complete. (x) MS terminal box both on HT and LT site. (xi) Oil temperature indicator with maximum & minimum temperature rise indicator. (xii) Plain breathing device which would not permit ingress of rain water and insects. (xiii) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug, (xiv) Oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator) (xv) Necessary channel on foundation for fixing the transformer with joint and stopper. (xvi) Transformer drawing shall be got approved by Accepting Officer/representative before placing of order.
Supply installation testing and commissioning Servo voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type, unbalanced type, copper wound, digital display type, relay free smooth and silent operation with 1 filling of transformer oil (IS 335: 2018 ) & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 1% and speed of correction 50 Volts per second and of capacity 200 KVA including taking down of old BER voltage stablizer and deposited to MES store yard complete all as specified and directed The following specification./standard accessories shall also be provided :- (a). Input voltage 340V-460V (b). Out put Voltage 415V + 1% (adjustable ) (c ) Rated frequency 50 Hz (No distortion in wave form (d) response time not to exceed 10 mile seconds (e) Sensitivity (+) 1% (f) Rate of correction more then 6 volts/second for per phase (g) Class of insulation- A (h) No load losses less then 0.5% & Full load losses less than 2.5% (j) Efficiency more than 95%. Protections (k). Over load/short circuit protection (l). High/ Low voltage cut off (m) By pass arrangement in case of emergency (n) Single phase sequence change protection (o) Duty cycle - continuous 24 x 7 (p) Type of load, 3 phase, unbalanced type (q) Digital display voltmeter/Ampmeter
Excavation in trenches n.exc 1.5 Mtr wide and n.exc 1.5Mtr depth and getting out for errection of LT poles, stay assembly and laying of cable etc in soft/loose soil complete all as specified and directed by Engineer-in-Charge
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cms. thick in soft / loose soil complete all as specified and directed by Engineer-in-Charge
Removing of excavated material to a distance n.exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed by Engineer-in-Charge
M&L for sand cushioning in trenches spreading and consolidation 8cm thick before laying the cable & 15 cm of sand after laying the cable complete all as specified
Supplying and laying reinforced precast concrete cable cover, class HV, Type 1 , flat, size 300mm x 180mm x 40mm
Supply, Laying, jointing, jointing and testing of under ground cables XLPE insulated screened PVC bedded galvanized steel strips armored electric power cable (heavy duty) with aluminium conductor HT 11000 volts grade and cross section area 95 sqmm 3 core conforming to latest IS and ISI marked laid in trenches complete all as directed .
S & F cable route indicators made out of PCC block of size 30 x 80 x10 cm marked "MES HT CABLE" 1/6 of the PCC block to be grounded in ground level completed all as specified and directed.
M & L for 40 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in floor finishing even and smooth with using extra cement and making impression of expanded metal, whilst concrete is green over 100 mm thick PCC (1:4:8) type D-2(using 40 mm graded stone aggregate) with and including to make the road surface making good as per existing surface etc complete all as specified and directed by the Engineer in Charge.
Demolition for cement concrete/road in ground floor and paving n. exc 15 cm thickness below or above ground level including removal of rubbish to a distance exc 1.50 Km and n.exc 5.00 Km etc complete all as specified
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm
Switch Air break gang operated triple pole mechanically operated out door with all fitting/accessories mounted on and including 11 KV HT porcelain insulator vertical mounting with drop out fuses having 12 Nos insulators,triple pol and steel channel frame GI operating rod 25 mm dia of suitable lenght with operating mechanism worked from ground level vertically operated including 7 lever naval lock for operating handle complete suitable for current rating 200 Amps HT 11 KV working pressure, including taking down old unserviceable switches air break, complete all as specified and as directed. Make: /BHEL/PACTIL/Japuria brothers
Supply and fixing in replacement of HT feeder pillar box outdoor type factory made weather and vermin proof made out from 3.15 mm sheet supported with legs all across the panel made of angle iron 50x50x5 mm of size 1.2 mtrx1 mtrx1 mtr with 3 Nos required length Aluminium bus bar of size 40x10mm or 400 Amps for 11 KV , 11 KV post Insulator 6 Nos duly drilled hole for HT Cable connection including front and rear side openable with locking arrangment suitable for 11 KV HT and provision for incoming and out going HT cable connection including painting with two coats of smoke gray synthetic enamels paint over a coat of red oxide primer complete and providing security fence XPM jally type of 2 mtr height from ground level square type all rounded 2.5 mtr length with 9nos angle iron of 25x25x5mm of hight 2.25mtr (2mtr above ground 0.25 mtr under ground) including necessary location gate of same XPM jally all as specified and directed . Note:- Feeder piller box shall be mounted on brick platform built in PCC not less then 60 cm above ground level with suitable PCC foundation rendering 15 mm in CM (1:6), applying two coats and cement base paints and XPM jally supported on 9 nos angle iron with concrete base.
Dismantling concrete poles/ struts, any size complete all as specified and as directed
Dismantling existing unserviceable ACSR conductor of any size all as specified and directed.
Dismantling cross arms of MS channels or angle sections etc complete all as specified and directed.
Dismantling insulator any type, any size complete all as specified and directed
Supply, fixing, connection and testing of HT overhead lines on existing/new poles with XLPE insulated, Screened PVC bedded Aerial Bunch cable 11 KV (E), 95 Sqmm x 3 core having bunch of three single core cable duly twisted with each other around insulated steel messenger wire of size 1x70 sqmm throughout the length the cable should confirm to IS: 8130-1984, IS:398 (Part-IV)-1994, IS:7098 (Part-II)-2011 & IS: 5831-1984 with up to date amendments including provn of holding pole clamps/ pole mounting support clamps, end termination, connnetor all types, nut & bolts, anchor clamps on each existing/new pole with proper protection to the cable and other protective materials/accessories as required at poles complete all as specified and directed.
Supply and erect of steel tubular swaged pole complete with mild steel base plate 6 mm thick of size 300mm x 300mm finial taper plug, bolts,nuts and wqaqshers type 410 SP-55 (11 mtr long) including drilling of hole of adeuate size and painted with two coat of aluminium paint over a coat of red oxide on exterior surface and two coat of black bituminous paint to portion embeeded in concrete painting five alternate black/white bands of 300 mm height each at lower portion upto 1.5 mtr height complete all as specified and as directed Note: Excavation, earth work and PCC for foundation to be measured and paid separately.
PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate in foundation of electric poles including necessary from work and exposed surfaces finished fair without using extra cement complete all as specified and directed by Engineer-in-Charge
PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in bands, coping, bed plates etc including slightly rounded or chambered angles complete all as specified and directed by Engineer-in-Charge
Note:- Deduction for Schedule of credit (Sch 'A' Part-II) to be made of ₹ 129830.00 from the total quoted amount of BOQ while accepting the bid. Details of schedule of credit is given in tender documents.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
BOQ_836442.xls
BOQ • 1.37 MB
TENDER39.pdf
Tender Documents • 0.76 MB
Download all tender documents and submit your bid