| 1 | L1₹15.5 LAccepted-AOC | ₹15.5 L Quoted ₹15.9 L | L1 | Accepted-AOC lowest bidder |
| 2 | L2₹16.1 L+₹24,100 (1.52%)Rejected-Finance 203 NABIL APARTMENT ASHOK NAGAR OPP HATHIKHANA ANAJ MARKET TULSIWADI ROAD KARELIBAUG VADODARA 390018 GUJARAT | VADODARA | GUJARAT | 390018 | ₹16.1 L+₹24,100 (1.52%) | L2 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | FAIZA ENTERPRISE L2 | SWASTIK INFRA L1 |
|---|---|---|---|---|---|
| 1.00 | Supply and charge refrigerant gas R-407 in AC plant, of any capacity complete all as specified and directed by Engineer-in-charge. | 216 | KG | 1,100 ₹2,37,600 | 900 ₹1,94,400 Lowest |
| 2.00 | M&L for servicing & repair to pan type humidifier of 15KW SS 304 sheet welded by replacement of worn out parts & make fully functional in all aspects complete all as specified and directed by Engineer-in-charge. | 2 | EACH JOB | 2,000 ₹4,000 Lowest | 19,000 ₹38,000 |
| 3.00 | M&L for servicing & repair of fire damper complete with smoke detector /thermistor and actuator as required for operation .fire damper shall be spring activated on melting fusiable link & replacement of worn out parts & make fully functional in all aspects complete all as specified and directed by Engineer-in-charge. | 2 | EACH JOB | 1,000 ₹2,000 Lowest | 10,500 ₹21,000 |
| 4.00 | M&L for servicing of PACKAGE TYPE 14 TR unit including cleaning of filters by cleaning with chemical solution as required at site , blower motor greasing fan belt tensioning , cleaning of indoor cooling coil of package unit & replacement of worn out nut bolts etc. complete all as specified and directed by Engineer-in-charge. | 2 | EACH JOB | 10,000 ₹20,000 | 3,500 ₹7,000 Lowest |
| 5.00 | M&L for opening end covers of condenser unit including cleaning of condenser of AC plant by circulating descaling compound by using high pressure pump after discaling including and cleaning the condensor coil by chemical and cleaning with nylone brush according to scale condition for copper tubes and refixing end covers, replacement of gasket set, worn out nut bolt & washers etc complete all as specified and directed by Engineer-in-charge. Note - descaling job is carried out twice in tendor and paid speratly for each time | 16 | EACH JOB | 10,000 ₹1,60,000 | 3,000 ₹48,000 Lowest |
| 6.00 | Supply and replacing of compressor oil for compressor as per site requirement complete all as specified and directed by Engineer-in-charge. | 60 | LTRS | 300 ₹18,000 | 200 ₹12,000 Lowest |
| 7.00 | M&L for servicing of AHU of AC plant including cleaning of filters by cleaning with chemical solution as required at site complete all as specified and directed by Engineer-in-charge. | 2 | EACH JOB | 1,500 ₹3,000 Lowest | 2,000 ₹4,000 |
| 8.00 | Disconnecting the electrical connection & taking down the burnt out motor of capacity 10 HP from AC Plant and transporting to workshop for repair, dismantling the motor & taking out burnout copper winding and rewinding the same with super enamelled copper wire as per existing guage including replacement of bearings & correcting minor defects, reassembling, incl any machinary works such as welding, grinding, tuning, polishing etc and transporting motor from workshop to site, reinstalled at site, reconnecting, testing and commissioning complete complete all as specified and directed by Engineer-in-charge. | 2 | EACH JOB | 15,000 ₹30,000 | 9,000 ₹18,000 Lowest |
| 9.00 | All as per iem No.8.00 here-in-before above but of capacity 7.5HP motor of pump set/compressor motor/ cooling tower/ blower motor, 3 Phase, 450 Volts | 2 | EACH JOB | 12,000 ₹24,000 | 7,000 ₹14,000 Lowest |
| 10.00 | All as per iem No.8.00 here-in-before above but 5 HP motor for pump set/ Compressor motor/blower motor/cooling tower motor, 3 Phase, 450 Volts | 2 | EACH JOB | 10,000 ₹20,000 | 6,000 ₹12,000 Lowest |
Tender Value
₹17 L
EMD Value
₹34,000
Closing Date
21 Jul 2026, 6:00 pmClosed
CWE (A) Jaisalmer
HQ CWE ARMY JAISALMER 345001 RAJASTHAN
REPAIR AND MAINTENANCE OF AC PLANTS AUDITORIUM AND NAVY UNDER GE (A) JAISALMER
2026_MES_773738_1
84444/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
JAISALMER
AS PER NIT
8 documents required · 8 mandatory
₹500
GE ARMY JAISALMER
₹34,000
Yes
16 Sept 2026
20 Jun 2026
23 Jul 2026
20 Jun 2026
21 Jul 2026
4 Jul 2026
20 Jun 2026 - 25 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and charge refrigerant gas R-407 in AC plant, of any capacity complete all as specified and directed by Engineer-in-charge. | 216 | KG | - | - |
| 2 | M&L for servicing & repair to pan type humidifier of 15KW SS 304 sheet welded by replacement of worn out parts & make fully functional in all aspects complete all as specified and directed by Engineer-in-charge. | 2 | EACH JOB | - | - |
| 3 | M&L for servicing & repair of fire damper complete with smoke detector /thermistor and actuator as required for operation .fire damper shall be spring activated on melting fusiable link & replacement of worn out parts & make fully functional in all aspects complete all as specified and directed by Engineer-in-charge. | 2 | EACH JOB | - | - |
| 4 | M&L for servicing of PACKAGE TYPE 14 TR unit including cleaning of filters by cleaning with chemical solution as required at site , blower motor greasing fan belt tensioning , cleaning of indoor cooling coil of package unit & replacement of worn out nut bolts etc. complete all as specified and directed by Engineer-in-charge. | 2 | EACH JOB | - | - |
| 5 | M&L for opening end covers of condenser unit including cleaning of condenser of AC plant by circulating descaling compound by using high pressure pump after discaling including and cleaning the condensor coil by chemical and cleaning with nylone brush according to scale condition for copper tubes and refixing end covers, replacement of gasket set, worn out nut bolt & washers etc complete all as specified and directed by Engineer-in-charge. Note - descaling job is carried out twice in tendor and paid speratly for each time | 16 | EACH JOB | - | - |
| 6 | Supply and replacing of compressor oil for compressor as per site requirement complete all as specified and directed by Engineer-in-charge. | 60 | LTRS | - | - |
| 7 | M&L for servicing of AHU of AC plant including cleaning of filters by cleaning with chemical solution as required at site complete all as specified and directed by Engineer-in-charge. | 2 | EACH JOB | - | - |
| 8 | Disconnecting the electrical connection & taking down the burnt out motor of capacity 10 HP from AC Plant and transporting to workshop for repair, dismantling the motor & taking out burnout copper winding and rewinding the same with super enamelled copper wire as per existing guage including replacement of bearings & correcting minor defects, reassembling, incl any machinary works such as welding, grinding, tuning, polishing etc and transporting motor from workshop to site, reinstalled at site, reconnecting, testing and commissioning complete complete all as specified and directed by Engineer-in-charge. | 2 | EACH JOB | - | - |
| 9 | All as per iem No.8.00 here-in-before above but of capacity 7.5HP motor of pump set/compressor motor/ cooling tower/ blower motor, 3 Phase, 450 Volts | 2 | EACH JOB | - | - |
| 10 | All as per iem No.8.00 here-in-before above but 5 HP motor for pump set/ Compressor motor/blower motor/cooling tower motor, 3 Phase, 450 Volts | 2 | EACH JOB | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
TENDER_84444.pdf
Tender Documents • 3.38 MB
BOQ_866369.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .