Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC | L1 | Accepted-AOC Awarded being lowest bidder | |
| 2 | L2₹34.7 L+₹4.1 L (13.3%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹35.3 L+₹4.6 L (15.0%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹39.5 L+₹8.8 L (28.8%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
₹29.8 L
EMD Value
₹59,560
Closing Date
27 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Balance work of CA No GE(N)/ANR/70 of 2020-2021 Proviso of certain sanctioned work in the area of AGE B/R II under GE (N) Ahmednagar
2021_MES_484412_1
8578 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Yes
₹59,560
Yes
4 Dec 2021
28 Oct 2021
29 Nov 2021
28 Oct 2021
27 Nov 2021
15 Nov 2021
60 days
Amount
Excavating in trenches n exc 1.5 m deep and 1.5 m wide and getting ing out in any type of soil etc complete all as specified and directed by Engineer-in-Charge
All as per item No 1 (here-in-before) but in hard / dense soil
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation /mass concrete etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC M25 using 20mm graded stone aggregate (1:1:2) as in foundation, footing, plinth beams, and mass concrete etc complete all as specified and directed by Engineer-in-Charge
Formwork to sides of concrete foundation, footings and plinth beams, and similar work etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC M25 using 20mm graded stone aggregate as in columns etc complete all as specified and directed by Engineer-in-Charge
Formwork to sides of columns for rough finished sufaces etc complete all as specified and directed by Engineer-in-Charge
Formwork to slab not exc 200mm thick for rough finished sufaces etc complete all as specified and directed by Engineer-in-Charge
Formwork to edges of roofs horizontal or sloping and similar work exc 10cm and n.exc 20cm wide for rough finished surfaces etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC M25 using 20mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs and the like etc complete all as specified and directed by Engineer-in-Charge
Formwork to sides of roof beams, beam including support, overhangs for rough finished surface, etc complete all as specified and directed by Engineer-in-Charge
Formwork to chajjas for rough finished surfaces etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC M25 using 20mm graded stone aggregate as in beams, lintels over 1.5 m span etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC M25 using 20 mm graded stone aggregate as in in Chhajjas etc complete all as specified and directed by Engineer-in-Charge
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire ( annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed by Engineer-in-Charge
All as per item No 15 (here-in-before) but 6 to 8mm dia TMT bars
All as per item No 15 (here-in-before) but TMT bars 5mm dia and over up to and incl 10mm dia in stirrups, spacers and binder
M & L for Pre-cast cement concrete solid blocks, exc. 10 cm in width type C-1 (1:3:6) using 20 mm graded stone aggregates and setting in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering 10mm thick in cement and sand mortar (1:6) on any type of face of brick work or concrete surfaces, finished surfaces even and smooth without using extra cement and applying sagol finish etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering 15mm thick in cement and sand (1:4) on any type of face of brick work or concrete surfaces finished surfaces even and smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge
M&L for providing water proofing treatment on roofs as per manufacturer's instructions and as specified after taking down/out as existing at site :- (a) Cleaning the newly plastered surfaces with wire brushes and applying a coat of bituminous primer @ 0.25 ltrs/sqmts and allow to dry. (b) Applying and laying torch APP polymer modified bituminous membrane 3 mm thick with non woven polyester matt as reinforced weighing not less than 3 kg/sqmts with white gravel/mineral finished by thermo fusion process incl applying one coat of aluminium paint.
M&L for rendering 10mm thick in cement and sand mortar (1:3) on roof mixed with and including WPC @ 3% by weight of cement and finished the surface even and smooth without using extra cement. Note :- Water proofing compound shall be measured and paid separately under relevant item of this BOQ
Supply only integral water proofing compound etc complete all as specified and directed by Engineer-in-Charge
M & L for preparation of newly plastered surface of wall and apply two coats of OBD over 2 mm thick Birla white putty finished with roller finish etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of plastered surface and applying 3 coats of white wash on ceiling etc complete all as specified and directed by Engineer-in-Charge
M&L for preparing new plastered surface of wall applying two coats of cement paint over one coat of primer etc complete all as specified and directed by Engineer-in-Charge
Supply and fix steel windows with side hung double shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded etc complete all as specified and directed by Engineer-in-Charge
Supply only MS guard bars 10 mm welded to steel window / ventilators etc complete all as specified and directed by Engineer-in-Charge
M&l for preparing new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer exc 10 cm width or girth etc complete all as specified and directed by Engineer-in-Charge
S&F 3 mm thick ordinary quality plain steel glass glazing with oil putty in square not exceeding 0.5 sqm in each pane etc complete all as specified and directed by Engineer-in-Charge
M&L for moorum filling in floors or paving laid in layers n.exc. 15cm thick spread leveled and rammed including watering etc complete all as specified and directed by Engineer-in-Charge
M&L for hardcore of gauge exc 63mm but n.exc 100mm, deposited, spread and leveled rolled in layers n.exc 15 cm thick, watered and rammed to a true surface etc complete all as specified and directed by Engineer-in-Charge
M&L for 75mm thick PCC (1:3:6) type C-2 (40mm graded stone aggregate) as in plinth protection etc complete all as specified and directed by Engineer-in-Charge
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) in sub base etc complete all as specified and directed by Engineer-in-Charge
M&L for machine cut kota stone slab flooring 20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete over and including screed bed 15mm thick in cement and sand mortar (1:4) surface finished even and fair etc complete all as specified and directed by Engineer-in-Charge
All as per item No 35 (here-in-before) but in skirting 10 mm thick rendering in cement and sand mortar (1:3) etc complete all as specified and directed by Engineer-in-Charge
S&F 35mm thick plain framed, paneled shutter( two panel) with lock rail and panel of 9mm BWP commercial plywood. The size of rail and stile as per IS:1003 (Part I) kiln seasoned and chemically pressure treated etc complete all as specified and directed by Engineer-in-Charge
S&F pressed steel frames of size 105 mm X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed by Engineer-in-Charge
Returning, filling including spreading leveling, watering and well ramming in layers n.exc 25cm in soft/loose etc complete all as specified and directed by Engineer-in-Charge
Removing excavated (soil) material n.exc 50m and depositing where directed at a level n. exc 1.5m above the starting point etc complete all as specified and directed by Engineer-in-Charge
M&L preparation of new wooden surfaces of any description over 10mm width of girth & applying two coats of synthetic enamel paint over one coat of pink primer etc complete all as specified and directed by Engineer-in-Charge
S&F 100 mm size butt hinges ,medium weight, cold rolled mild steel and fixed etc complete all as specified and directed by Engineer-in-Charge
S&F of 150 mm long mild steel barrel tower bolts, stove enameled, with bright bolt and Fixed etc complete all as specified and directed by Engineer-in-Charge
S&F of 150 mm long mild steel barrel pressed handles oval type stove enameled black etc complete all as specified and directed by Engineer-in-Charge
S&F of 300mm mild steel, sliding door bolts, plate type stove enameled black with bright bolt not less than 12mm with and incl a minimum of 6 bolts and nuts four on bolt plate and two on staple plate and fixed etc complete all as specified and directed by Engineer-in-Charge
Dismantling of stone slab & tiles of any description in floor, laid, bedded & pointed in any mortar. In any situation etc complete all as specified and directed by Engineer-in-Charge
Excavating over areas, n exc 1.5 m deep and getting out in any type of soil etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC (1:2:4) type B1 using 20 mm graded stone aggregate in floor basement and similar work etc complete all as specified and directed by Engineer-in-Charge
Cutting holes into or through cement concrete slabs,chajjas, etc.reinforced or otherwise n exc 100 Sqcm etc complete all as specified and directed by Engineer-in-Charge
M&L for non - skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles as in floor etc laid over and including screed bed 15 mm thick in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge
All as per item No 50 (here-in-before) but in skirting or in vertical surface over 10 mm thick rendering in cement and sand mortar (1:4) etc complete all as specified and directed by Engineer-in-Charge
S&F 10 mm thick POP decorative ceiling (Gypsum anhydrous)3D model to flat surface over and including, boarders and lining as approved by GE/ Engr-in-Charge with anodised aluminium snap grid frame work for false ceiling etc complete all as specified and directed by Engineer-in-Charge
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by Engineer-in-Charge
M&L raking out joints/ pointing from stone walls, random rubble or polygonal rubble uncoursed or brought up to courses in cement and sand mortar or cement lime mortar including existing paint/ cement base paint etc incl scrubbing, washing the surface with water before plastering etc complete all as specified and directed by Engineer-in-Charge
M&L for keyed pointing to random or polygonal rubble, uncoursed or brought up to course in cement and sand mortar (1:4) etc complete all as specified and directed by Engineer-in-Charge
M & L for preparation of new surface of wall and applying three coats white wash etc complete all as specified and directed by Engineer-in-Charge
M & L for preparation of old surface of wall and applying one coat white wash etc complete all as specified and directed by Engineer-in-Charge
Running welding in repairs thickness of metal to be welded n' exc 6 mm etc complete all as specified and directed by Engineer-in-Charge
S & F 16 to 18 mm thick Dholpur stone wall cladding gang saw cut with machine cut edges, uniform colour of each stone size not exc 0.25 sqm fixed with adhesive upto any height in patches to match with existing ones incl making V groove at top and bottom of stone and drilling hole for fastener, polishing, rubbing & including silicon treatment etc complete all as specified and directed by Engineer-in-Charge
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil etc complete all as specified and directed by Engineer-in-Charge
S&F steel ventilator with top hung shutter including hinges, steel peg stay etc complete all as specified and directed by Engineer-in-Charge
M&L for galvanized mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanized wire cloth etc complete all as specified and directed by Engineer-in-Charge
M&L for Non - skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry over & including 15mm thick screed bed and pointed in white or coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge
M & L coloured glazed ceramic tiles in vertical surface 300x 200 mm x 7 mm thick set and jointed in neat cement slurry on 10mm thick backing coat in cement and sand mortar (1:3) on skirting, and pointed in white or colour cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge
S&F 35 mm thick IInd class hardwood factory made glazed & skeleton shutters open rebated and prepared to receive glass gauge, divided into square or rectangles with plain chamfered or rounded mitered & rebated slash bars including beads mitered for securing glass wire gauge etc complete all as specified and directed by Engineer-in-Charge
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat molded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing. etc complete all as specified and directed by Engineer-in-Charge
S&F solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing etc complete all as specified and directed by Engineer-in-Charge
S&F of 125x 60 mm size steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed by Engineer-in-Charge
S&F Vitreous China urinals, bowl type flat back size 465x 355x 265 mm white (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs wash hand basin vitreous China white, flat back type of size 550 X 400 mm pedastal type including pedastal, CP waste chain and plug and porcelain stopper, waste pipe, a pair of brackets,or errecting stand and PVC connection all as specified and directed. Make :- Cat Part No 10098 of Hindware or equivalent in makes in mentioned in list of makes in Appendix `C'
Supply and fix in repairs vitreous China white squatting pan, Orissa pattern of size 580 X 440 mm width with integral foot rest set in cement concrete including flush pipe and connecting to trap / flushing cistren complete all as specified and directed.Make :- Cat Part No C0117 Of Parryware or Cat Part No 20042 of Hindware or equivalent in list of makes in Appendix `C'
Cutting chases for concealed water tubing etc complete all as specified and directed by Engineer-in-Charge
M & L for 15 mm bore GI tubing medium grade with all fitting and fixed complete on walls and ceilings or laid in floors etc incl taking down old, etc complete all as specified and directed by Engineer-in-Charge
M & L for 20 mm bore GI tubing medium grade with all fitting and fixed complete on walls and ceilings or laid in floors etc incl taking down old, etc complete all as specified and directed by Engineer-in-Charge
S & F PVC connections 15 mm size with PTMT nuts of length 450 mm etc complete all as specified and directed by Engineer-in-Charge
S&F of swivel shower with arm of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms)
Supply and fixing in repairs stop valve cast copper alloy, fancy type screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fix of size 15 mm bore Make:- (Cat part No MOR 1320(Orintal series) of MARC or equivalent in makes mentioned in list of makes in Appendix `C'
S&F for 20 mm dia float valve with brass body etc complete all as specified and directed by Engineer-in-Charge
S&F tubular towel rail, 20 mm dia D type, 60 cm long between flanges etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repair bib tap, 15 mm bore CP cast copper alloy with crutch or butterfly handle screwed down for iron pipe or for brass ferrule all as directed.Make:- (Cat part No MOR 1020 A(Orintal series) of MARC or equivalent in makes mentioned in list of makes in Appendix `C'
Supply and fix 15 mm bore pillar tap, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe all as directed.Make:- (Cat part No MOR 1010(Orintal series) of MARC or equivalent in makes mentioned in list of makes in Appendix `C'
M&L cast iron floor/Nahani trap with grating 75mm dia including jointing to waste pipe fixed in cement concrete type (1:2:4) type B1 using graded stone aggregate including removing old traps etc complete all as specified and directed by Engineer-in-Charge
M&L for grating doom 100mm dia PTMT etc complete all as specified and directed by Engineer-in-Charge
S&F in repair 600mm x 450 mm beveled edge mirror etc complete all as specified and directed by Engineer-in-Charge
S&F of 40 mm bore low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and directed by Engineer-in-Charge
S&F of 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls etc complete all as specified and directed by Engineer-in-Charge
S&F of 75 mm bore PVC (SWR) bends with access door etc complete all as specified and directed by Engineer-in-Charge
S&F of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls etc complete all as specified and directed by Engineer-in-Charge
S&F of 110 mm bore PVC (SWR) bends with access door etc complete all as specified and directed by Engineer-in-Charge
M&L for Reinforced concrete pipes 150 mm bore, class NP2, laid and jointed complete with collars etc complete all as specified and directed by Engineer-in-Charge
M&L for Concrete bed to drain pipes in PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) including packing under and haunching against the sides of pipes after they are laid tested etc bore of pipe 150mm dia etc complete all as specified and directed by Engineer-in-Charge
Material and labour for PCC (1:3:6) type C1 using 20 mm graded stone aggregates as in coping including weathering, slightly rounded or chamfered angles and throating and necessary form work etc complete all as specified and directed by Engineer-in-Charge
Material and labour for plain cement concrete in PCC (1:3:6) type C1 using 20 mm graded aggregates in surface benching in manholes, channel etc complete all as specified and directed by Engineer-in-Charge
M&L for reinforced precast cement concrete cover slab, (1:2:4) type B1 using 20 mm graded stone aggregates including necessary form work for manhole covers etc. set in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mitered/stopped ends etc complete all as specified and directed by Engineer-in-Charge
M&L for 60mm thick machine pressed pre-cast , PCC M-35, rubber molding, glossy finish interlocking tiles conforming to IS 15658 of 2006 ,over and including 30 mm thick sand cushion & joints filled with sand etc complete all as specified and directed by Engineer-in-Charge
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 etc complete all as specified and directed by Engineer-in-Charge
S&F of Expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanized steel staples supplied and fixed complete to wood or steel members etc complete all as specified and directed by Engineer-in-Charge
M&L for pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, coloure and design as approved by GE etc complete all as specified and directed by Engineer-in-Charge
S&F of Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 etc complete all as specified and directed by Engineer-in-Charge
Welding in repairs n. exc 2.5 cm in length, thickness of metal to be welded n. exc 6 mm etc complete all as specified and directed by Engineer-in-Charge
Excavation in post holes ( or similar holes) each not exc 0.5, cum getting out in soft/loose soil, returning , filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25 cm, watering and removing surplus soil to a distance not exc 50 metre and making good surface etc complete all as specified and diected by Engineer-in-Charge
S&F framed bracket of angles or tees with web and flanges cut to shape, drilledandcountersunk for screw, including bending and welding angles as necessary gusset plates rivertting etc not exc 10 Kg each brackets, conforming to Fe-410 or Fe-310-0(Brackets over 10 Kg each to be measured under "Structural Steel") etc complete all as specified and directed by Engineer-in-Charge
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of CI/pressed steel terminal switch box and white bakelite plastic laminated top sheet cover and fixed with brass screws cup washer for fixing witches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth & connecting to earth dolly for the following, etc complete all as specified and directed by Engineer-in-Charge. Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, bulkhead lights, bldg security light etc
One light point controlled by one, one way switch single pole
One fan point controlled by one, one way switch single pole
One 3 pin 5 Amps socket out let on independent board.
One 3 pin 5 Amps socket out let on same board.
All as per Item No 104 here-in-before but 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket out let on independent board
S&F Switch Piano Flush type 230/250 Volt, 5 Amps single pole one way, all as specified and directed
S&F bell push, switch flush type, 5 Amps etc complete all as specified and directed by Engineer-in-Charge
S&F bell, AC, 230 volts single pole etc complete all as specified and directed by Engineer-in-Charge
S&F stepped type electronic fan Regulator flush type on the existing phenolic laminated etc, as reqd single pole 240 volts grade 100 watts heavy duty ISI marked etc complete all as specified and directed by Engineer-in-Charge
S&F switch socket combination multi purpose 2 in 1, 6 pin 5 Amps, flush type ISI marked etc complete all as specified and directed by Engineer-in-Charge
S&F switch socket combination 5 in 1, 5 Amps/15Amps, flush type ISI marked etc complete all as specified and directed by Engineer-in-Charge
S&F ceiling rose surface bakelite 65mm x 50mm three etc complete all as specified and directed by Engineer-in-Charge
S&F lamp holder PVC/Polycarbonate type with cord grip cap suitable for pendant fittings etc complete all as specified and directed by Engineer-in-Charge
S&F in replacement double door Sheet metal enclosures factory made DBs 8 way, 240 volts protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 100 A copper Busbar, With Neutral bar, Earthbar and Cable lies for Cable management, Fully shrouded, Neutral bars, Prefitted masking sheet complete all as specified and as directed. Make: Legrand, Cat No. : 507611 or equivalent in makes mentioned in list of makes in Appendix `C'
S&F Isolators of the under mentioned type and rating and fixing in DBs (DBs measured and paid for separately) Note :- Make of the isolator should be the same as that of DB) for thre following :-
Supply & fixing MCB , SP, AC, 240 volts of 06 to 32 Amps, 10 KA Capacity, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed. Make: Legrand, Cat No. : 4085-87 to 90,92,93,94,95 or equivalent or equivalent in makes mentioned in list of makes in Appendix `C'
Supply & fixing MCB, SPN, AC, 240 volts of 32-63 Amps, 10KA Capacity, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed. Make: Legrand, Cat No. : 4086-17 to 20 or equivalent in makes mentioned in list of makes in Appendix `C'
S&F tube light fitting & Supply & fix LED tube light aling with fixture, 20W
M&L Earthing complete with galvanized earth plate electrode 600x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvenised earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 5 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work PCC(1:3:6) type C-1 pit with precast RCC Cover slab 40 mm thick in PCC(1:2:4) type B-0 reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe complete all as spfd and as directed. connected to earthing list point all as specified and as directed.
S&F sub main wiring with two single core PVC insulated,unsheathed, FRLS stranded copper conductor cable 6 Sqmm with 6 Sqmm PVC insulated, unsheathed, FRLS stranded copper conductor cable as earth wire drawn through in and incl PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) Note: Two run of 6 sq.mm cable i.e for one run for phase, one run for neutal with one run of 6 sq.mm cable for earth and one run of PVC Casing & caping shall be measured as one unit
S&F LED bldg security light 30W IP 65 all as complete as directed by Engr-in-charge Make : Cat NO LSTS-30-CDL-M or equivalent in makes mentioned in list of makes in Appendix `C'
Supply and fix in replacement industrial type switch socket for Geyser with 20 Amps MCB etc complete all as specified and directed by Engineer-in-Charge. Make : Legrand Cat No. 6078 41 20 A SP complete or equivalent in makes mentioned in list of makes in Appendix `C'
Supply and fix heavy duty exhaust fan, 300 mm sweep, 900 RPM, 230 V, 50 Hz with fixing of fan duly grouted in bolts and connecting with 3 core flexible copper cable of size 1.5 Sqmm all as directed including making holes in wall/window etc complete all as specified and directed by Engineer-in-Charge
Supply and fix Water heater storage type, electric, capacity 25 litre, BEE 5 star rated including water supply connection etc complete all as specified and directed by Engineer-in-Charge
Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 5000 CuM per hour (or nearest size).Plastic/PVC Body etc complete all as specified and directed by Engineer-in-Charge
Supply and fix water cooler electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour etc complete all as specified and directed by Engineer-in-Charge
Supply & fix fans ceiling complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated etc complete all as specified and directed by Engineer-in-Charge
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core etc complete all as specified and directed by Engineer-in-Charge
Excavation in trenches not exceeding 1.5 metre wide & not exceeding 1.5 meter in depth for foundation, laying of cable or pipe and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engr-in-charge.
Returning, filling in trenches in soft/loose soil in layers n.exc. 25 cm after laying of cables including spreading, levelling, wtering, and well ramming complete all as directed by Engr-in-Chrage.
Removing surplus excavated soil to a distance n.exc. 50 metre and depositing where directed at a level n.exc.1.5 metre high from the starting point all as directed by Engr-in-Chrage.
M & L for sand cushioning with dry and clean sand over and under the under ground cable in trenches , ducts for cable protection incliding levellling and consodilation complete all as specified and directed by EIC. Note : Punned thickness shall be measured.
Supplying and laying un-reinforced precast concrete cable cover,Class LV, Type I, flat, size 250 mm x 150mm x 40mm all as specified and as directed by Engr-in-charge.
M/s AG PATHAN
OM SAI ASSOCIATES
M/s. N D Karande
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .