Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Quoted amount | |
| 2 | L2₹17.9 L+₹74,585 (4.34%)Rejected-Finance | L2 | Rejected-Finance Not Eligible | |
| 3 | L3₹21.5 L+₹4.3 L (24.7%)Rejected-Finance | L3 | Rejected-Finance Not Eligible |
Tender Value
₹19.6 L
EMD Value
₹39,100
Closing Date
3 Jan 2023, 6:00 pmClosed
GE (AF) PURNEA
GE AF PURNEA, P.O - CHUNAPUR AIR FIELD, DIST- PURNEA BIHAR, PIN CODE- 854303
SPECIAL REPAIR TO BLDG NO. P33 PARACHUTE WAY AT AIR FORCE STATION PURNEA UNDER GE AF PURNEA
2022_MES_567669_1
8001/E8
Open Tender
Civil Works
Item Rate
180 days
PURNEA
Please Refer Tender Documents
6 documents required · 6 mandatory
₹500
GE (AF) PURNEA
₹39,100
Yes
2 Feb 2023
6 Dec 2022
5 Jan 2023
6 Dec 2022
3 Jan 2023
20 Dec 2022
Amount
M&L for non skid coloured tiles (square/rectengular) 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface with and including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 complete all as specified and as directed.
M&L for 100 mm thick cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregates) as in floor and finished surface even and fair complete all as specified and as directed.
M&L 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite with and including over screed bed or bedding layer of mortar 20mm thick in cement mortar (1:4), with and including necessary moulding full round complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 sqm each, with and including cutting holes for taking out hold fasts or dismantling brick work complete all as specified and as directed. Note:- Holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 sqm but n exc 4.0 sqm each, with and including cutting holes for taking out hold fasts or dismantling brick work complete all as specified and as directed. Note:- Holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.
Taking down shutters of any description not exceeding 1 sqm each complete all as specified and as directed.
S&F powder coated (minimum thickness of powder coating 50 micron) aluminum frames for doors, windows, ventilators with one or more rebates including jointing cleats for fixing etc. complete all as specified and as directed.
S&F powder coated (thickness of powder coating not less than 50 micron) aluminium door of approved design complete all as specified and directed with all fixing arrangement including providing and fixing aluminium door handle, aluminium tower bolts, mortice lock 6 lever (Make - Harrison/Godrej) one on each door and aluminium Powder coated tower bolts 200 mm long (03 Nos on each shutters) and 5 mm thick tinted glass pane of glazed shutter along with aluminium glazing beading of size 19.00 mm x 17.5 mm x 0.70 mm @ weight of 0.097 Kgs per RM including rubber gasket on both side complete alongwith neoprene lining. The member shall be made out of extended aluminium sesction comprising of :- (Size of the door shall be as per site requirement) (a) Door frame of size 95.25 mm x 44.50 mm x 1.70 mm @ 1.301 Kg/RM. (b) Shutter vertical member 85 x 44.50 x 1.56 mm @ 1.39 Kg per RM. (c) Shutter top member 83.50 x 44.50 x 1.54 mm @ 1.139 Kg per RM. (d) Shutter bottom member 101.60 x 44.50 x 1.60 mm @ 1.301 Kg per RM. (e) Shutter lock rail member 83.50 x 44.50 x 1.54 mm @ 1.139 Kg per RM. Note:- The actual measurement of area shall be taken and wastage shall be included in the rates. Above sections are from make -JINDAL/INDAL/HINDAICO/WALCO extruion. The contractor is at liberty to choose high section from approved make with minor variation in sizes and weight as approved. However nothing extra shall be paid for over size and over weight section also.
S&F aluminium powder coated (thickness of powder coating not less than 50 micron) frame and window shutters (glazed, wire gauge and grill) side hung with aluminium window frame or chowkhat 1.5 mm thick aluminium powder coated of size 100 mm x 44.5 mm and window shutter frames glazed and wire gauze (middle, top rail, bottom rail) and styles 1.5 mm thick aluminum powder coated of size 44.5 x 44.5 mm including powder coated aluminium grill 50 mm x 50 mm aparture and all fitting such as rubber gasket, aluminium glazing clips, locking cabinet, 4 mm thick tinted glass pane for glazed shutters, stainless steel wire mesh for gauge shutter and hook and eye for each shutter fixed with rubber gasket and glazing clip/aluiminium beads aluminium tower bolt 75 mm 02 Nos each shutter, aluminium butt hinges 75 mm 02 Nos in each shutter aluminium handle 100 mm 01 No in each shutter including all accessories complete all as specified and as directed.
S&F aluminium powder coated frame (thickness of powder coating not less than 50 micron), ventilator shutters (glazed, wire gauge and grill) side hung with aluminium window frame or chowkhat 1.5 mm thick aluminium powder coated of size 100 mm x 44.5 mm and ventilator shutter frames glazed and wire gauze (middle, top rail, bottom rail) and styles 1.5 mm thick aluminum powder coated of size 44.5 x 44.5 mm including powder coated aluminium grill 50 mm x 50 mm aparture and all fitting such as rubber gasket, aluminium glazing clips locking cabinet, 4 mm thick tinted glass pane for glazed shutters, stainless steel wire mesh for gauge shutter and hook and eye for each shutter fixed with rubber gasket and glazing clip/aluiminium beads aluminium tower bolt 75 mm 02 Nos each shutter, aluminium butt hinges 75 mm 02 Nos in each shutter aluminium handle 100 mm 01 No in each shutter including all accessories complete all as specified and directed.
S&F powder coated aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete as per requirement and direction.
S&F mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing; frame work for water tanks and similar work conforming to Fe 290 Gd E-165 complete all as specified and as directed.
S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and as directed.
S&F 3mm thick figured glass, pin head type or frosted and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and as directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of apreture 1.40mm and fixed with stainless steel wire wire staple complete all as specified and as directed.
M&L for plain, solid, straight chowkats and frames of 2nd class hard wood, wrought, framed rebated on the soild, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and as directed.
Demolition of brick/stone masonry built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and as directed.
M&L for providing cement concrete (1:2:4) type B0 (using 12.5mm graded stone aggregates) as in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles and throating complete all as specified and all as directed.
M&L for providing 50 mm thick cement concrete (1:3:6) type C-1 (using 20mm graded crushed stone aggregates) as in plinth protection, finished even and smooth without using extra cement and with and including providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed.
M&L for AC designer composite ceiling board 4mm thick in 600mmx600mm panel confirming to IS-14682 type-B category-3 with and including powder coated GI frame work with size of grid 605mm x 605mm for seemless ceiling comprising of GI perimeter, holdfast & suspenders and all accessories complete all as specified and as directed.
M&L for preparation of new wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
M&L for preparation of steel and iron surfaces of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chromate primer complete all as specified and as directed.
M&L for applying 3mm thick (min) layer of cement base wall care putty on walls to give uniform surface complete all as specified and as directed. NOTE:- Before applying of wall care putty complete removal of existing treatment shall be carried out as directed and approved by Engr-in-charge.
M&L for applying two coats of white washing as on ceiling including preparation of new/old plastered surfaces complete all as specified and as directed.
M&L two coats of oil bound distemper on walls including preparation on new/old surfaces over coat of primer complete all as specified and as directed. .
M&L for two coats of weather proof exterior emulsion paint (Camouflage pattern) over a coat of primer including preparation of new plastered surfaces of any description complete all as specified and as directed. Note:- Camuflage pattern shall be approved by GE.
Dismantling asbestos cement (corrugated or semi corrugated, etc) sheets as in roof covering complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete as all specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F MS flat iron as in wind ties etc conforming to Fe 410-0 or Fe 310-0 including clamps complete all as specified and as directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position and in unframed work complete all as specified and as directed.
S&F rolled section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, eaves board framing work, tank staging work etc conforming to Fe- 410-W complete all as specified and as directed.
S&F vinyal flooring 4mm thick coloured polyvinyl chloride resin suspension grade is the basic raw material for forming PVC compound. PVC resin then is mixed with chemical like Calcium, Stearate, Hydrocarbon wax, Titanium Dioxide, Calcium Carbonate, Acrylic processing aids. Further addivities like impact modifiers, pigments, Epoxy plasisizer, lubricants, chemical blowing agent etc. are added. The purpose of adding the chemicals and addivities is to impart cellular and resistance to fading by light rays. These chemical are mixed in the desired proportion and shall be used in the formulation of PVC material and free from smooth extruction of PVC profiles complete and as per manufactures instructions and directed.
Taking down carefully copper/alluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
M&L for point wiring concealead type with suitable PVC conduit of 1.5 sqmm size single core multi stranded copper conductor unsheathed PVC insualted 1100 V grade FRLSH cable drawn into and including PVC conduit adequate width and length with accessoris and fittings like bend, elbows, crosses, wall crossing etc for one light /fan point controlled by one switch including sunken type pressed steel box suitable for modular switches, sockets outlet and regulators etc and with continuous single core cable 1.5 sqmm copper conductor PVC insualted, unsheathed as earth wire connected to earth dolly and to be connected boxes of suitable sizes for mounting to fittings etc, complete all as specified and as directed. Note- Modular switch and socket base plate shall be measured and paid seperately under respective items of BOQ.
Description all as per ser item No 36.00 here-in -before but 1.5 sqmm copper conductor for 3 pin 5 Amps socket outlet on independent (Multiple) boards controlled by one switch with one No earth continuity copper conductor of size 1.5 sqmm complete all as specified and as directed. Note- Modular switch and socket base plate shall be measured and paid seperately under respective items of BOQ.
Description all as per item No. 36.00 here-in -before but 2.5 sqmm copper conductor for 3 pin 15 Amps socket outler on independent (Multiple) boards controlled by one switch with one No earth continuity copper conductor of size 2.5 sqmm complete all as specified and as directed. Note- Modular switch and socket base plate shall be measured and paid seperately under respective items of BOQ.
M&L for modular switch piano, flush type one way 6 amps 1 module complete all as specified and as directed.
M&L for modular switch piano, flush type one way 16 amps 1 module complete all as specified and as directed.
M&L for modular socket, 6A-2/3 pin combination 2 module complete all as specified and as directed.
M&L for modular socket, 6A/16A-2/3 pin combined 2 module complete all as specified and as directed.
M&L for modular bell push, flush type, 5 Amps complete all as specified and as directed.
S&F modular white cover plate with frame, 1 module complete all as specified and as directed.
S&F modular white cover plate with frame, 3 module complete all as specified and as directed.
S&F modular white cover plate with frame, 6 module complete all as specified and as directed.
Taking down old unserviceable sub main wiring of copper/alluminium conductor complete all as specified and as directed.
S&F submain concealed PVC conduit wiring with 3 run of single core FRLSH, 6 Sqmm (Nominal area) PVC insulated, unsheathed, multistanded copper conductor cable 1100 Volts grade drawn through and including PVC non-metalic conduit of suitable size, medium grade (ISI marked) with all fittings and fixing accessories on roof, wall, ceilings etc complete all as specified and as directed. Note:- Three runs of 6 Sqmm cable and one run of PVC conduit in wall/ceiling shall be measured as one length.
Taking out old unserviceable DB any size and any capacity complete all as specified and as directed.
S&F double door sheet metal enclsoures TPN DB 4 way with 200 amps rated bus bar 415 volts complete all as specified and as directed.
S&F double door sheet metal enclosures SPN DB 8 way with 200 Amps rated bus bar 240 Volts complete all as directed.
S&F MCCB TPN 415 volt, 63 Amps, breaking capacity 16 KA complete all as specified and as directed.
S&F isolator/MCB SPN 240 volt, 40 Amps 'C' curve complete all as specified and as directed.
S&F MCB SP 240 volt, 6 to 32 Amps, C-curve complete all as specified and as directed.
M&L for ceiling rose, 3 phase/ PVC /Polycarboante, isolated body complete all as specified and as directed.
M&L for bell Multy Music type or ding dong single pole 230 Volt complete all as specified and as directed.
S&F modular fan regulatior stepped type electronic 2 module complete all as specified and as directed.
M&L for PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 150 mm x 100 mm and 50 mm deep complete all as specified and as directed.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 240 volt complete all as specified and as directed.
M&L for modular metal flush box 1/2 module complete all as specified and as directed.
M&L for modular metal flush box 3 module complete all as specified and as directed.
M&L for modular metal flush box 6 module complete all as specified and as directed.
Taking out old unserviceable ceiling/exhaust fan any size and any capacity complete all as specified and as directed.
S&F exhaust fans AC single phase 230/ 240 V of size 380 mm sweep ,900 rpm with louver complete all as specified and as directed. MAKE:-HAVELLS (MODEL-TURBO FORCE SP) or equivalent make of USHA,ORIENT,BAJAJ.
S&F ceiling fan, energy saving 5 star rating complete with three blades, down rods accessories, 230 V,1200 mm sweep complete all as specified and as directed. MAKE:-HAVELLS (MODEL-ES40) or equivalent make of USHA,ORIENT,BAJAJ.
S&F Air Circulator fans 230 volts single phase oscillating 600 mm sweep suitable for wall mounting including all fixing accessories and fixing arrangement complete all as specified and as directed. MAKE:-HAVELLS (MODEL-TURBO FORCE) or equivalent make of USHA,ORIENT,BAJAJ.
Supply and fixing LED lights fitting 1x 22W, 220V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. MAKE:-HAVELLS ,CAT PART NO-LUMILINE+BS22WLED865SPCSS or equivalent make of BAJAJ, CENTURY LED LTD (BRAND MAGIK) ,/ CROMPTON GREEVES CONSUMER ELETRCIALS LTD / EVEREADY INDUSTRIES INDIA LTD
Taking up old unserviceable security light fitting/LED tube light fittings any size & type from the building including taking out old GI pipe bracket complete all as specified and as directed.
Supply and fix LED security light fitting 35Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp, bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. MAKE:-HAVELLS ,CAT PART NO-ENDCITYLITPLAT+SL35WLED757SASYBOPCWOSPD or equivalent make of BAJAJ, CENTURY LED LTD (BRAND MAGIK) ,/ CROMPTON GREEVES CONSUMER ELETRCIALS LTD / EVEREADY INDUSTRIES INDIA LTD
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.MAKE:-HAVELLS ,CAT PART NO-DROPDOWNFLAT2X2PLR36WLED830S or equivalent make of BAJAJ, CENTURY LED LTD (BRAND MAGIK) ,/ CROMPTON GREEVES CONSUMER ELETRCIALS LTD / EVEREADY INDUSTRIES INDIA LTD
Taking up old unserviceable lightening protection rod with cable/strip of any size & type and connected items from the roof/wall complete all as specified and as directed.
S&F safe lightening protection rod (Early Streamer Emission Lightening Conductor), fully autonomous having lower series of energy collecting electrodes, upper series of spark- generating electrodes, an inbuilt micro controller for detection of lightening down ward leader and releasing upward leader at that very precise moment to ensure nuisance free, fail safe, real need based operation any and every time in all type of lightening i.e.Positive/ Negative /UP/Down, sealed in a stainless steel housing fixed at the centre of its central rod which has full electrical connectivity direct up to earth point, having gain in triggering time not less than 60 micro sec giving 107 Meters radius, Level IV, High/Medium/Standard Protection complete all as specified and as directed.
Supply and Erection of a mast ASM45 (4.5m long) suitable for ESE Technology based lightening protection installation, mechanically robust, good corrosion and fire resistant, GI/ MS Painted, alongwith guying kit, foundation and other accessories required for installation of the mast complete all as specified and as directed.
Supply and fixing Thor mast coupler suitable for ASM45 complete all as specified and as directed.
Supply & installation of 'A.L.I.C.E' digital (ASHLOK"s) lightening strike counter electromechanical) in weather proof box of IP66 grade protection along with clamps etc complete all as specified and as directed.
Supply and fixing SLPR accessories provided in box complete all as specified and as directed.
M&L for earth continuty conductor or main earthing lead fixed to wall on batten or recess or burried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthig etc as required with copper strip of 20 x 3 mm with saddle & fixing screw etc for roof conductor and down conductor above ground complete all as specified and as directed.
M & L for earthing complete with copper earth palte electrode (600 x 600)mm x 3.15mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below ground level connected to galvanized iron copper strip (20 x 3) mm by means of bolts, nuts, check buts and washers of galvanized rion and steel complete all as shown in electrical plate No 3 and connected to earth test point including necessary excavation in any type of soil, earth work, chamber cover, wire mesh, funnel, test point, GI protection pipes 32 mm dia,and watering pipe 20mm dia with necessary salt and charcoal etc complete and testing on completion complete all as specified and as directed.
MSRAMANUJSINGHSONS
M/S.M.S.Devi.Const.Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .