Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.6 CrAccepted-AOC F 2 87 88 SEC 11 ROHINI DELHI 85 | 85 | ₹2.6 Cr | 1 | Accepted-AOC ok |
| 2 | 2₹2.7 Cr+₹16.4 L (6.40%)Rejected-Finance 5A 24 ANSARI ROAD DARYA GANJ NEW DELHI 110002 | CENTRAL | DELHI | 110002 | ₹2.7 Cr+₹16.4 L (6.40%) | 2 | Rejected-Finance Higher than the Lowest one |
| 3 | 3₹2.8 Cr+₹28.2 L (11.0%)Rejected-Finance | ₹2.8 Cr+₹28.2 L (11.0%) | 3 | Rejected-Finance Higher than the Lowest one |
| 4 | 4₹4.9 Cr+₹2.3 Cr (90.6%)Rejected-Finance B 85 1 NEAR SECTOR 4 BLOCK B SURYA VIHAR GURUGRAM HARYANA 122001 | GURUGRAM | GURUGRAM | HARYANA | 122001 | ₹4.9 Cr+₹2.3 Cr (90.6%) | 4 | Rejected-Finance Higher than the Lowest one |
Tender Value
₹3.9 Cr
EMD Value
₹8.0 L
Closing Date
5 Nov 2022, 3:05 pmClosed
Executive Engineer Electrical /NGZ
MUNICIPAL CORPORAIONOFFICE OF DELHI OFFICE OF THE EXECUTIVE ENGINEER (ELECT)/NGZ ROOM NO -219, II ND FLOOR, ZONAL OFFICE BUILDING, DHANSA STAND , NAJAFGARH, NEW DELHI-110043
Part A Provision of street lights poles from Rewla Bus stand to Rewla khanpur village chowk, Rewla to Tajpur village Galibpur village to Sarangpur Galibpur road in ward no. 40S. Part B Providing and Fixing Kharkhdinahar, Raghopur, Pandwal underNGZ
2022_SDMC_132791_1
EE/Elect/Najafgarh Zone/2022-23/11
Open Tender
Electrical Works
Item Rate
180 days
Najafgarh Zone
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
₹8.0 L
Office of the Chief Engineer Electrical 10th Floor
2 Jan 2023
20 Oct 2022
7 Nov 2022
20 Oct 2022
5 Nov 2022
20 Oct 2022
27 Oct 2022
Amount
Part - A
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm and ID-51 mm nominal)
Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump,DG set etc.including form work etc. as req.
Supplying and fixing of light class GI pipe of 50 mm dia.(nominal) 3 meter length along the pole for protection of underground cable as req.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:- 2x 10 sqmm
Fabrication, supply and erection of following size flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full vertical window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor- 4 nos. and shorting links on DIN channel i/cpdg and fixing DIN channel of suitable length, 6 Amp. SMeterCB C characteristics, earth stud, cable support clamp suitable for upto 4x25 sqmm cable. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS. 7.0 mtr height, 3 mm thick, bottom dia of 130mm and top dia of 70mm base plate of size 225 x 225 x 12 mm thick
Providing and laying in position M25 grade reinforced cement concrete foundation of size 600 mm (L) x600 mm wide and 1200 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 1160 mm long(approx)-8 nos. and reinforcement of cold twisted bars of 8 mm dia- 1600 mm (approx) -8 nos.(with 150 mm spacing) as required with supplying and positioning of 4 nos. foundation bolts 20mm dia, 750 mm long, J type i/c 2 nos. template anchor plates of size 225mmx225mmx3mm and providing DCW HDPE for cable entry and exit as required for 7m and 8 mtr pole.
Fabrication, supplying and fixing class B galvanised double overhang arm bracket made out of 250mm long galvanised top tube with cap and 1000mm long 40 mm dia galvanised pipe with tightening bolts complete as required.
Fabrication, supplying and fixing class B galvanised single overhang arm bracket made out of 250mm long galvanised top tube with cap and 1000mm long 40 mm dia galvanised pipe with tightening bolts complete as required.
Providing and laying of HDPE PIPE 40mm outer dia with PN rating 4 by hand/manual method conforming toIS 4984.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and fixing of stainless steel name plate of size 6 x 8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required.
Part - B
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
Supplying and fixing of light class GI pipe of 50 mm dia.(nominal) 3 meter length along the pole for protection of underground cable as req.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( with charcoal/ coke and salt ) as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as req .
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Fabrication,Supplying,Installation,testing,Commissioning of 12 mts.high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick (Single dip ) inside and out sides and suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circufrential weld. It should also included accessories for High Mast head frame ,2 point suspension system with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. flood light luminaries luminaries symmitrically and its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L)X1m (W)X2m deep i/c excavation of earth i/c excavation of earth, providing cutting, bending and placing in position, rewinforcement of cold twisted bars of 12 mm dia -2100 mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of 4 nos foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for high mast considering The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c,4Nos S.P MCB,63Amp.DPIsolator etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. galvanized as per relevant IS.
Supply of XLPE insulated,PVC sheathed Al.conductor Armoured Cable Conforming to IS 7098/1988 of following Sizes (a) 2 X 10 SQmm
Providing and laying of HDPE PIPE 40mm outer dia with PN rating 4 by hand/manual method conforming toIS 4984.
ACE ENGINEERS BUREAU
SACHDEVA ELECTRICALS
Shanti Electrical Co.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .