| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 CrAccepted-AOC NO157 14 13TH B MAIN ROAD 1ST STAGE 1ST PHASE GOKULA BANGALORE 560054 | BENGALURU URBAN | KARNATAKA | 560054 | ₹5.2 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹5.6 Cr+₹48.3 L (9.35%)Rejected-Finance WZ 487 2 MS BLOCK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | ₹5.6 Cr+₹48.3 L (9.35%) | L2 | Rejected-Finance Being not L1 |
| 3 | L3₹5.9 Cr+₹73.3 L (14.2%)Rejected-Finance | ₹5.9 Cr+₹73.3 L (14.2%) | L3 | Rejected-Finance Being not L1 |
| 4 | L4₹6.3 Cr+₹1.2 Cr (22.5%)Rejected-Finance | ₹6.3 Cr+₹1.2 Cr (22.5%) | L4 | Rejected-Finance Being not L1 |
| 5 | L5₹6.8 Cr+₹1.7 Cr (32.5%)Rejected-Finance | ₹6.8 Cr+₹1.7 Cr (32.5%) | L5 | Rejected-Finance Being not L1 |
Tender Value
₹6.0 Cr
EMD Value
₹6.2 L
Closing Date
7 Jun 2024, 6:00 pmClosed
Neeraj Mehrotra, IDSE, CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
PROVISION OF DEFICIENT INFRASTRUCTURE FOR CHILDREN SCHOOL AT AFS JALAHALLI
2024_MES_648073_1
85278/E8
Open Tender
Civil Works
Lump-sum
720 days
GE(M) AF JALAHALLI
As per tender documents
7 documents required · 7 mandatory
₹3,000
GE (M) (AF) Jalahalli
₹6.2 L
11 Jul 2024
28 Mar 2024
10 Jun 2024
28 Mar 2024
7 Jun 2024
24 May 2024
28 Mar 2024 - 10 Apr 2024
Amount
GENERALSUMMARY Note : Schedule ‘A’ Part I (Serial No 2) to be quoted by contractor under Col 6 and not prepriced by MES and prepriced rates indicates 0.00 under column 5 signifies this fact only. Schedule 'A' part II to part IX (Serial No 3 to 10) are prepriced by MES under Ser No. 2 to 5. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Design and Construction of School Building including RCC framed of minimum design mix M25, AAC/PCC block masonry, Anti Termite Treatment, Water Proofing Tratment, etc, complete as specified and shown on drawings.
Lumpsum price worked out by the contractor for “Internal Electrification ” as listed in Schedule ‘A’ Part–II representing **______________% (_______________________)* above/below the lumpsum price of Rs. 22,39,432.87 inserted by MES for Schedule 'A' Part-II.
Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’ Part–III representing **______________% (_______________________)* above/below the lumpsum price of Rs. 2,24,793.59 inserted by MES for Schedule 'A' Part-III.
Lumpsum price worked out by the contractor for “Roads” as listed in Schedule ‘A’ Part–IV representing **______________% (_______________________)* above/below the lumpsum price of Rs. 11,95,531.19 inserted by MES for Schedule 'A' Part-IV.
Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part–V representing **______________% (_______________________)* above/below the lumpsum price of Rs. 2,61,005.62 inserted by MES for Schedule 'A' Part-V.
Lumpsum price worked out by the contractor for “Area Drainage” as listed in Schedule ‘A’ Part–VI representing **______________% (_______________________)* above/below the lumpsum price of Rs 5,60,777.61 inserted by MES for Schedule 'A' Part-VI.
Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part–VII representing **______________% (_______________________)* above/below the lumpsum price of Rs.12,26,545.58 inserted by MES for Schedule 'A' Part-VII
Lumpsum price worked out by the contractor for “External Water Supply” as listed in Schedule ‘A’ Part–VIII representing **______________% (_______________________)* above/below the lumpsum price of Rs. 3,26,651.03 inserted by MES for Schedule 'A' Part-VIII
Lumpsum price worked out by the contractor for “Demolition/Dismantling” as listed in Schedule ‘A’ Part–IX representing **______________% (_______________________)* above/below the lumpsum price of Rs. 8,16,221.59 inserted by MES for Schedule 'A' Part-IX.
SCHEDULE `A' PART - X MISCELLANEOUS ITEMS - Items are not prepriced by MES and prepriced rates indicates 0.00 under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6.
Supply and fixing TPN distribution boards,Vertical type,4 Way, protection class IP-43 Double door suitable for mounting MCCB,63 Amps as incomer and MCB SPN as outgoing with min 200 Amps rating bus bar ,Concealed in wall all as specified and directed.
Supply, Hanging and connecting up energy efficient ,five star rated BLDC ceiling fan of size 1200 mm sweep complete and down rod including provision of flexible copper cable 3 core of size 0.5 sqmm from ceiling rose to fan, provision of 3 mm thick circular Bakelite sheet cover including writing MES NO. 2 CM height with synthetic enamel black paint all as specified and as directed.
Supply and fixing SMC Meter boxes ,suitable for 3 phase meter of size 485 mm x 340 mm x 185 mm with transparent lid ,single piece moulded,concealed metal hinges ,wall mounted all as specified and directed by engineer in charge .Cat part No GSMB-4834 of Sintex or equivalent.
M&L earthing complete with galvanised steel pipe electrode of size 40 mm bore,medium grade,2.5 meter length, burried directly in ground in bore 350 mm dia verticalIy to a depth not less 3.2 meter below ground level with top edge of the pipe not less than 60 cm below normal ground level connected to galvanised earth lead wire 4.0mm dia by means with bolts, nuts check nuts and washers protected by Gl light grade pipe of size 15 mm dia and connecting up with the DB as the case may be upto a maximum distance of 7.5m away from the earth electrode including test point junction, excavation, earthwork, PCC Chamber, RCC Cover(Yellow painted) with handle , watering pipe 20mm dia GI Medium grade with funnel and wire mesh, Charcoal dust , salt,Mild steel Earth marker with earthing result ,date all as per plate no.2 of SSR 2009( part-I) and as directed. Note:- Boring charges are included in the above quoted rates .
M&L for Cutting of Bituminious road/ hard standing/PCC path/wall including excavation in soft/loose soil for depth of 25cm and for width of 25cm and make smooth after work with PCC Nominal size cement concrete 1:2:4 type B1 (20mm stone aggregate) complete all as specified and directed.
M&L for Boring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine includings HDPE pipes of 80 mm dia suitable for 0.4 Mpa working pressure complete all as speified and directed.
Supply and fix for wiring of suitable size for street light fitting connection tapping from the line / connecting up from the junction box to the fitting etc with 1.5 sq mm multistranded PVC insulated conductor and non metalic PVC Rigid / flexible conduit (20mm dia) shall be measured as one unit length, all as specified and directed.
M& L for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983 and as directed. Note :- (i) Excavated approved soil shall be ribbed by using sieve to separate composite particles etc as per IS and refiiling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is than gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness only will be considered for paymet.
M&L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22, 8.5 meters including two coats of black bituminous paint planting depth and two coats of synthetic enamel paint of alternate black and red strips, 30cm high over coat of red oxide primer upto 1.5m height from GL/coping and remaining portion with red oxide primer complete all as specified and directed. Note : Necessary excavation and earth work, PCC foundation, coping etc, shall be measured and paid separately.
M&L Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55, 11 meters long confirming to IS 2713 (Part-I to III) 1980 including two coats of black bituminous paint throughout internally and externally upto planting dept and two coats of synthetic enamel paint of alternate black and red strips, 30cm high over coat of red oxide primer upto 1.5m height from GL/coping and remaining portion with red oxide primer complete all as specified and directed. Note : Necessary excavation and earth work, PCC foundation, coping etc, shall be measured and paid separately.
Supply and fix PVC cable loop box,(pole box) size inside not less than 250 mm x 200 mm x 120mm, out door type, duly fitted on bottom of RCC/ steel poles with suitable clamp, nuts, bolts & washers complete to accommodate and including one No of 6 Amps single pole MCB, & suitable alumiium busbar of 3 phase 4 wire porcelain insulated connectors for incoming and outgoing connections fixed in repairs all as specified and directed. Make : Sintex Cat Pt No:-GS-JB-2520-II/ Hensal/ Legrand
M&L for bracket made out of GI tubing light grade, 40mm dia, for street light fixing, 1.5 mtr long GI Pipe including fixing with MS Iron clamps - 2 Nos made out of size 40mmX40mmX3mm thick flat iron with top cover welded with GI Tubuing M.S. nuts, bolts 75 mm long 12 mm dia -4 Nos & flat washer (3mm thick) 01 No. for each including preparation of steel surfaces and painting with two coats of aluminium paint over one coat of red oxide to the M.S iron clamps & bracket etc complete all as specified and as directed.
Supply, install, testing and commissioning of Busber Panel board outdoor type, dust and vermin proof totally enclosed platform mounted factory made (Protection Class IP-56) having CPRI approved, front openable shutters with locking arrangements made of CRCA sheet 3.15mm thick with MS angle iron frame work, duly painted, all as specified including necessary foundation bolts grouted in PCC (1:2:4) type B1 for mounting the panel, suitable for 415 Volts, 50 Hz, three phase, 4 wire system complete internal wiring with copper conductor, the overall size of the feeder pillar box shall be suitable to accommodate in and including the following accessories :- (a) Aluminium Bus Bas chamber 4 strip on insulators of 600 Amps capacity 500 volts – 1 set. INCOMING :- (a) MCCB, FP 350Amps, 35/36 KA adjustable, Thermal, Magnetic - 1 Nos. (b) Digital multi function meter with suitable CT's (c) Indication Lamp (RYB) (Set of 3) 1 set complete all as specified as directed.
Supply, install, testing and commissioning of LT Panel board outdoor type, dust and vermin proof totally enclosed platform mounted factory made (Protection Class IP-56) having CPRI approved, front openable shutters with locking arrangements made of CRCA sheet 3.15mm thick with MS angle iron frame work, duly painted, all as specified including necessary foundation bolts grouted in PCC (1:2:4) type B1 for mounting the panel, suitable for 415 Volts, 50 Hz, three phase, 4 wire system complete internal wiring with copper conductor, the overall size of the feeder pillar box shall be suitable to accommodate in and including the following accessories :- (a) Aluminium Bus Bas chamber 4 strip on insulators of 600 Amps capacity 500 volts – 1 set. INCOMING :- (a) MCCB, FP, 350Amps, 35/36 KA, Adjustable thermal and magnetic type -1 Nos (b) Digital multifunction meter with suitable CT's OUTGOING :- (a) MCCB, FP, 63 Amps, 25 KA – 5 Nos (b) MCCB, TPN, 32 Amps, 10 KA – 1 No (c) Timer switch, 250 Volts, single phase, 20 Amps rating with contractor.
Earthing for panels and DG Sets/machinery/power equipment complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of plate not less than 1.5 m below ground level connected to and including galvanised earth strip of size 32x6 mm (up or 7.5 mtr length) and GI pipe 40 mm light grade for protection of GI earth strip by means of bolts, nuts, checknuts and washers made out of galvanised iron and connected to earth test point as shown in electrical plate No. 3 of SSR Part-1-2009 and as specified or indicated and testing on completion including excavation and earth work any in type of strata available at site, PCC (1:3:6) type C-1 for earth chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire fabric (xpm) weight not less the (4kg/sqm) funnel with GI watering pipe of 20mm bore medium grade, wire nuts and lugs complete all as speified and directed.
Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of plate not less than 1.5 m below ground level connected to and including using GI strip of size 25 X 4mm (up or 7.5 mtr length) and GI pipe 40 mm light grade for protection of GI earth wire by means of bolts, nuts, checknuts and washers made out of galvanised iron wire and connected to earth test point/Poles as shown in electrical plate No. 3 of SSR Part-1-2009 and as specified or indicated and testing on completion including excavation and earth work any in type of strata available at site, PCC (1:3:6) type C-1 for earth chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire fabric (xpm) weight not less the (4kg/sqm) funnel with GI watering pipe of 20mm bore medium grade, wire nuts and lugs complete all as speified and directed.
Supply, install, testing and commissioning of Capacitor Bank Built in LT Panel board suitable for 160KVA transformer, 3Phase 415 Volts, outdoor type made out 3.15 mm thick CRCA sheet and fixing capacitor, contractor, APFC relay and power factor meter and making bank connection using suitable size of copper wire, CTR, copper bus bar including angle iron 50x50x6m frame (bottom portion of the panel), grouted by using PCC foundation 1:2:4 type C1 with 20mm graded stone aggregate, thimbling and cable entry boxes with cable gland incld locking arrangement and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete with following :-
(a) MCCB 4 pole 200 amps of 25KA - 01 No (b) Capacitor 40 KVAR (20+10+5+5) -1 No (c) Capacitor duty contractor one step higher than capacitor-01 No (d) APFC relay-01 No (e) Power factor meter-01 No (f) MCB TP 63 amps-04 Nos (g) Indicator lamp (set of 3)-01 Set. Note - The panel shall be complete with bus bars, discharge resistors, protection HRC fuse, all internal wiring, labels, capacitor number in terms of switching process, all and above APFCR with manual overridden facility complete all as directed.
M& L for preparing bituminous surfaces of road and marking 2.5mm thick centre lines, stop lines, dashes, arrows etc and the like n.exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine alll as per manufacturers instruction complete all as specified and directed.
M&L for construction of brick massonary valve chamber of size 600x600x600 mm with angle iron frame and MS sheet cover 3mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide prime including lifting handle, locking arrangement, excavation and earth work, plastering complete all as specified and directed.
Cutting the existing pipe up to 200mm dia CI pipe and inserting 200x200x100mm tee including necessary jointing material, fittings including excavation and earth work completed all as specified and directed.
S&F of PVC connection 15mm size with PTMT nuts and washers of length 600mm complete all as specified and as directed.
S&F of 15mm bore of 2 in 1 tabs, cast copper alloy chromium plated with capstan head, screwed down, screwed for 15mm bore for CPVC pipe complete all as specified and as directed.
M/S Shiv Shakti Enterprises
UNITED TECHNO PROJECTS PVT LTD
SMLP ASPHALTS
C R R CONSTRUCTIONS
M Mohan Babu
Phoenix Infra
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .