| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 LAccepted-AOC 4 107 EDAYARPALAYAM KUNIYAMUTHUR COIMBATORE 641 008 | COIMBATORE | TAMIL NADU | 641008 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹3.9 L+₹19,327.45 (5.28%)Rejected-AOC | L2 | Rejected-AOC REJECTED |
Tender Value
₹5 L
EMD Value
₹5,000
Closing Date
25 Sept 2024, 3:00 pmClosed
Assistant Commisssioner,West Zone
West Zone, Coimbatore Corporation
Sinking of New Borewell at Indhira Nagar in Ward no 74 of West Zone.
2024_MAWS_481741_36
E4/WESTZONE/2024
Open Tender
Civil Works
Works
90 days
West Zone, Coimbatore Corporation
As per the tender document attached
4 documents required · 4 mandatory
₹0
₹5,000
14 Dec 2024
9 Sept 2024
26 Sept 2024
9 Sept 2024
25 Sept 2024
9 Sept 2024
Amount
Provision for Geologist from the TamilNadu Agricultural University for inspecting the site and for making the borewell point as per departmental officers instructions etc. complete .
Drilling of borewell 180 mm dia vertical bores depth as directed by the departmental officers including labour charges for inserting causing pipe assembling in the drilled holes including welding, jointing, grouting the casing pipe etc.,as per departmental officers instructions etc. complete .
Supply of 180 mm dia (inner) PVC casing pipe suitable wall thickness including erection and welding including the cast of coupling etc complete.
Drilling of borewell 165 mm dia vertical bores depth as directed by the departmental officers including labour charges for inserting causing pipe assembling in the drilled holes including welding, jointing, grouting the casing pipe etc.,as per departmental officers instructions etc. complete .
Supply and delivery of borewell 10 HP submersible pumpset at the characteristics head of 125x225m double cable motor compactable with star delta panel board only with vertical type with all accessories with latest FS 8034 year 2014-2015 in general for the following duty conditions the pumpset should have diagonally balanced bronze impler and stainless shaft for motor as per departmental officers instructions etc. complete .
Labour for the erection of submersible pumpsets in borewell including fixing and jointing submersible cable with proper claps upto the starter to the required depth and also fixing of riser pipes to the required depth values erection clamps, pressure gauge as per departmental officers instructions etc. complete .
Supply and fixing of Designing Fabrication Powder coating assembling wire ,testing and supply of double door type EB Metering star delta type panel board 3ph/63A 1no.(Rain Proof Model) as per Dept. Instruction etc. complete.
Supply for 4mm²x3 core copper insulated flat cable as per departmental officers instructions etc. complete .
Supply and delivery of the following Well water materials approved brand as per list with ISI marking and an approved by corporation officers.
50mm GI pipe B Class
50mm GI Heavy coupling
50mm GI Bend
50mm GI elbow
50mm GI Coupling
50mm GM Non return valve
50x300mm GI nipple
50x450mm GI nipple
50x600mm GI nipple
50mm Gm Gate valve
50mm Hex Nipple
borewell cover
50mm dia flange set
50mm borewell clampset
63mm dia pipe 6Kg/cm2
63mm PVC elbow
63mm PVC Tee
63mm PVC end cap
63mm PVC FTA
Solvent cement
Shellock Bottel
Supply of Electrical Arrangements materials etc., Complete
Arial Board For EB
EB service pipe set (32 mm dia GI B class 3 mtrs length)
Supply run of 4x6 sq mm (7.20) copper wire
63 Amps Fuse Carrier
Providing Ground Earthing arrangements by excavating 0.15 mm dia earth upto 3.05 mtr depth using agur piling machine and installing 2" dia Galvanised iron pipe of length 3.05 mtr is to bury vertically deep into the excavated ground as the base of the ground connector with 75 mm GI Flanges welded on.the flanges that are use have six holes which are used for wiring with copper wire ,the entire area surrounding the pipe is filled with layers of Charcoal,Salt and sand as earth reactivation compound including all cost etc complete.
Earth work excavation for foundation in all kind of soils and sub soils to full depth as directed by the department officers except hard rock inclusively of shoring strutting and balling out wter wherever necessary and refilling the sides of foundation with excavated earth work in layer of 15cm thick well rammed and consolidated and depositing the surplus earth with in the compound in places shown by the depatment oddicers with initial lead of 10 meters and initial lift of 2 meters including cost pf all labour charges etc., complete as per standard specification 23 &24 VI (S2) VII.9,10
Plain cement concrete 1:4:8 (one cement, four sand and eight aggregates) using 40mm ISS HBG metal including cost and conveyance of all materials and labor charges for mixing, laying and curing etc, complete as per SS
Brick work in cement mortar 1:5 mix (one cement five sand) using II class ground molded bricks chamber burnt bricks of size 9" X 4 1/2" X 3" for the following including curing etc., completed.
Plastering in Cement Mortar 1:5 mix 12mm thick
Supply of RCC precast slab 150mm thick in C.C. 1:1.5:3 mix using 20m baby jelly including water curing,moulding charges etc., complete. Size of slab and volume of concrete 2.00*0.45*0.15 = 0.135m3
Supplying, fabricating and placing in position TMT/CTD rods for all RCC works including cost of steel and binding wire also in all floors complete complying with standard specification
Earth work excavation in all soil including refilling
Laying and jointing of pvc pipes and specials
R.Senthilkumar Civil Engineering Contractor (BID ID -1143278)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .