Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹90.8 LAdmitted-Finance | -10.30% | ₹90.8 L | L1 | Admitted-Finance |
| 2 | L2₹93.3 LAdmitted-Finance | -7.90% | ₹93.3 L | L2 | Admitted-Finance |
| 3 | L3₹95.2 LAdmitted-Finance | -5.99% | ₹95.2 L | L3 | Admitted-Finance |
| 4 | L4₹96.2 LAdmitted-Finance | -4.99% | ₹96.2 L | L4 | Admitted-Finance |
| 5 | L4₹96.2 LAdmitted-Finance | -4.99% | ₹96.2 L | L4 | Admitted-Finance |
Tender Value
₹1.2 Cr
EMD Value
₹1.2 L
Closing Date
20 Feb 2026, 5:00 pmClosed
Executive Officer Brajrajnagar Municipality
Executive Officer Brajrajnagar Municipality At/Po-Lamtibahal, Ps-Brajrajnagar, Dist-Jharsuguda
Shopping Complex
2026_ORULB_125611_13
BRJNRM -05/2025-26
Open Tender
Civil Works - Buildings
180 days
Brajrajnagar Municipality
Please refer the tender documents
3 documents required · 3 mandatory
₹10,000
₹1.2 L
Yes
30 Mar 2026
7 Feb 2026
21 Feb 2026
7 Feb 2026
20 Feb 2026
7 Feb 2026
A) SHOPPING COMPLEX NEAR TUNNEL ROAD AT BRAJRAJNAGAR Clearing grass and removal of rubbish up to a distance of 50 metres outside the periphery of the area .
Excavation of Earth work in foundation in hard soil within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods and depositing the excavated materials within intial lead and lift, as per the direction of the Engineer-in-charge.
Supply & Filling in Foundation and Plinth with excavated materials including watering and ramming as directed by Engineer-in- charge for cum.
Filling foundation and plinth with send watered and rammed etc. complete including cost of sand.
Plain Cement concrete (1:3:6) by using 4 cm size B.H.G metal including cost, conveyence etc. complete.
R.C.C. works (M-25) in foundation, footing, beams, plinth band,footing ,base of columns,lintels, roofs, chhajas mass concrete etc. using 10 mm & 20 mm size black hard granite crusher broken chips including hoisting, lowering, laying and compacting, watering, curing for 28 days including centering and shuttering and finished the exposed surface smooth including all cost, conveyances, royalties and taxes of all materials and cost of labour with T & P required for the work etc. all complete in all respect but excluding cost of Steel and labour charges for bending and binding as per the Direction of the Engineer in charge. a) FOUNDATION, FOOTING AND BASE OF COLUMN
B)PLINTH BEAM
C)ALL KINDS OF BEAMS AND COLUMN
D) G.F SLAB,LANDING AND CHAJJA
E)G.F STAIRCASE EXCLUDING LANDING
F)LINTEL BAND
Supplying, fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specifications.
Fly ash brick masonry of size(25cmx12cmx8cm) size in Foundation & Plinth mortar (1:6) including splays, cutting circular moulding, corbelling, chamfering and similar such type of works, watering & curing including cost, conveyances, royalties taxes of all materials and cost of all labour with T&P required for the work etc. all complete in all respect as per the Direction of Engineer in charge.
Fly Ash. Brick masonry using Fly Ash. Bricks having crushing strength not less than 75 Kg. / cm2 in cement mortar (1:6) after immersing the brick for six hours in water before use in "superstructure" including splays, cutting circular moulding, corbelling, chamfering and similar such type of works, watering & curing including cost, conveyances, royalties taxes of all materials and cost of all labour with T & P required for the work etc. all complete in all respect as per the Direction of Engineer in charge.
12mm thick cement plaster (1:6) inside over brick massonary after racking out the joints watering and curing etc. complete with cost, conveyance royalties and taxes of all materials & all labour with T & P required for the work etc. all complete in all respect as per the Direction of the Engineer in charge.
16mm thick cement plaster (1:6) outside over brick walls in all floors after racking out joints including watering & curing etc. complete with cost, conveyance royalties & taxes of all materials & cost of all labour with T & P required for the work etc. all complete in all respect as per the Direction of the Engineer in charge.
6 mm thick cement plaster (1:4) ceiling including watering & curing etc. complete with cost, conveyance royalties & taxes of all materials & cost of all labour with T & P required for the work etc. all complete in all respect as per the Direction of the Engineer in charge.
Fixing tiles in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1(1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete excluding cost of precast tiles etc. all complete. vitrifed tile of size 600mm x 600mm Premium grade
Supplying, fitting and fixing tiles in dados, skirting and risers of Steps on 12mm thick cement paster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing including cost of precast tiles, labour T&P,Conveyence etc . complete required for the work as per the direction of engineer-in-charge. GROUND FLOOR
Painting 1 coats with approved cement primer on plastered surface (water bound) to after cleaning the surface including cost of conveyence and taxes of all materials including the cost of primer labour and T & P etc required for the work all complete in all respect as per direction of Engineer in charge. a)Internal Walls
b)External Walls
c)Ceiling
Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials labour T & P etc. as per direction of Engineer -In -charge. A) Internal Walls
B)Ceiling
Painting 1 coats with approved Plastic emulsion Paint of approved shades on new work to give even shade including cost of paint, cost of labour and T & P etc required for the work all complete in all respect as per direction of Engineer in charge.
Painting 1 coats to outside surface of walls etc approved shade and colour using weather coat to the surface after cleaning, including cost of conveyence and taxes of all materials including the cost of weather coat labour and T & P etc required for the work all complete in all respect as per direction of Engineer in charge.
Priming one coat with approved Red Oxide Primer on M.S. Grills in Windows, Rolling Shutters.
Painting two coats with approved Enamel Paint including cost of paint.
Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in staircase as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect.
Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.
Supplying, fitting and fixing of 5.5 mm thick hexagoanal Aluminum jally in windows as single groove, double groove and tapered clip as horizontal and vertical members for fixing of aluminum jally and jointing angle conforming to standard Aluminium sections etc. complete.
Supplying and fixing Rolling shutters of approved make, made of required size M.S laths inter locked together through their entire length and jointed together at ythe end by end locks mounted on the specially designed pipes shaft with brakets,side guides and arrangements for inside and outside locking with push and pill operation complete including the cost of providing and fixing necessary 27.5 cm long wire springs , garde no-2 and M.S top cover of required thickess for rolling shutter. all complete in all aspect as per the direction of the Engineer in charge. (80x1.25 mm M.S laths with 1.25 mm thuck top cover including providing and fixing of ball bearing for Rolling shutters as required including all cost, conveyence taxes , labour, T & P required for the work complete in all respect as per direction of Engineer in charge.
B) SHOPPING COMPLEX (FIRST FLOOR) R.C.C. works (M-25) in columns, roof beams,lintel band, roofs, chhajas mass concrete etc. using 10 mm & 20 mm size black hard granite crusher broken chips including hoisting, lowering, laying and compacting, watering, curing for 28 days including centering and shuttering and finished the exposed surface smooth including all cost, conveyances, royalties and taxes of all materials and cost of labour with T & P required for the work etc. all complete in all respect but excluding cost of Steel and labour charges for bending and binding as per the Direction of the Engineer in charge. a)ALL KINDS OF BEAMS AND COLUMN
B)F.F SLAB,LANDING AND CHAJJA
C)F.F STAIRCASE EXCLUDING LANDING
D)LINTEL BAND
Supplying, fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specifications.
Fly Ash. Brick masonry using Fly Ash. Bricks having crushing strength not less than 75 Kg. / cm2 in cement mortar (1:6) after immersing the brick for six hours in water before use in "superstructure" including splays, cutting circular moulding, corbelling, chamfering and similar such type of works, watering & curing including cost, conveyances, royalties taxes of all materials and cost of all labour with T & P required for the work etc. all complete in all respect as per the Direction of Engineer in charge.
12mm thick cement plaster (1:6) inside over brick massonary after racking out the joints watering and curing etc. complete with cost, conveyance royalties and taxes of all materials & all labour with T & P required for the work etc. all complete in all respect as per the Direction of the Engineer in charge.
16mm thick cement plaster (1:6) outside over brick walls in all floors after racking out joints including watering & curing etc. complete with cost, conveyance royalties & taxes of all materials & cost of all labour with T & P required for the work etc. all complete in all respect as per the Direction of the Engineer in charge.
6 mm thick cement plaster (1:4) ceiling including watering & curing etc. complete with cost, conveyance royalties & taxes of all materials & cost of all labour with T & P required for the work etc. all complete in all respect as per the Direction of the Engineer in charge.
Supplying, fitting and fixing vitrifed tile of size 600mm x 600mm Premium grade in floors conforming to IS 13755 laid on 20mm thick cement mortar(1:4) and filling joints with white cement of approved quality including cost of all materials, labour T&P,Conveyence etc . complete required for the work as per the direction of engineer-in-charge. FIRST FLOOR
Supplying, fitting and fixing tiles in dados, skirting and risers of Steps on 12mm thick cement paster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing including cost of precast tiles, labour T&P,Conveyence etc . complete required for the work as per the direction of engineer-in-charge. FIRST FLOOR a) vitrifed tile of size 600mm x 600mm Premium grade
b) Kota stone size minimum thickness 16mm above 0.10sqm.
Painting 1 coats with approved cement primer on plastered surface (water bound) to after cleaning the surface including cost of conveyence and taxes of all materials including the cost of primer labour and T & P etc required for the work all complete in all respect as per direction of Engineer in charge. A)Quantity referred from Inside plaster 12 mm thick Unit = Sqm
b) Quantity referred from Outside plaster 16 mm thick
c)Quantity referred from Celing plaster 6 mm thick
Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials labour T & P etc. as per direction of Engineer -In -charge. A)Quantity referred from Inside plaster 12 mm thick
B)Quantity referred from Celing plaster 6 mm thick
Painting 1 coats with approved Plastic emulsion Paint of approved shades on new work to give even shade including cost of paint, cost of labour and T & P etc required for the work all complete in all respect as per direction of Engineer in charge. A)Quantity referred from Inside plaster 12 mm thick
Painting 1 coats to outside surface of walls etc approved shade and colour using weather coat to the surface after cleaning, including cost of conveyence and taxes of all materials including the cost of weather coat labour and T & P etc required for the work all complete in all respect as per direction of Engineer in charge. A)Quantity referred from Outside plaster 16 mm thick
Priming one coat with approved Red Oxide Primer on M.S. Grills in Windows, Rolling Shutters.
Painting two coats with approved Enamel Paint including cost of paint.
Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing in 1st floor using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in staircase as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect.
Supplying, fitting and fixing of 5.5 mm thick hexagoanal Aluminum jally in windows as single groove, double groove and tapered clip as horizontal and vertical members for fixing of aluminum jally and jointing angle conforming to standard Aluminium sections etc. complete.
Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.
Supplying and fixing Rolling shutters of approved make, made of required size M.S laths inter locked together through their entire length and jointed together at ythe end by end locks mounted on the specially designed pipes shaft with brakets,side guides and arrangements for inside and outside locking with push and pill operation complete including the cost of providing and fixing necessary 27.5 cm long wire springs , garde no-2 and M.S top cover of required thickess for rolling shutter. all complete in all aspect as per the direction of the Engineer in charge. (80x1.25 mm M.S laths with 1.25 mm thuck top cover including providing and fixing of ball bearing for Rolling shutters as required including all cost, conveyence taxes , labour, T & P required for the work complete in all respect as per direction of Engineer in charge.
C) SHOPPING COMPLEX (TERRACE FLOOR) :-R.C.C. works (M-25) in columns, roof beams,lintel band, roofs, chhajas mass concrete etc. using 10 mm & 20 mm size black hard granite crusher broken chips including hoisting, lowering, laying and compacting, watering, curing for 28 days including centering and shuttering and finished the exposed surface smooth including all cost, conveyances, royalties and taxes of all materials and cost of labour with T & P required for the work etc. all complete in all respect but excluding cost of Steel and labour charges for bending and binding as per the Direction of the Engineer in charge. A)ALL KINDS OF BEAMS AND COLUMN
B) S.F SLAB,LANDING AND CHAJJA
C) LINTEL BAND
Supplying, fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specifications.
Fly Ash. Brick masonry using Fly Ash. Bricks having crushing strength not less than 75 Kg. / cm2 in cement mortar (1:6) after immersing the brick for six hours in water before use in "superstructure" including splays, cutting circular moulding, corbelling, chamfering and similar such type of works, watering & curing including cost, conveyances, royalties taxes of all materials and cost of all labour with T & P required for the work etc. all complete in all respect as per the Direction of Engineer in charge.
12mm thick cement plaster (1:6) inside over brick massonary after racking out the joints watering and curing etc. complete with cost, conveyance royalties and taxes of all materials & all labour with T & P required for the work etc. all complete in all respect as per the Direction of the Engineer in charge.
16mm thick cement plaster (1:6) outside over brick walls in all floors after racking out joints including watering & curing etc. complete with cost, conveyance royalties & taxes of all materials & cost of all labour with T & P required for the work etc. all complete in all respect as per the Direction of the Engineer in charge.
6 mm thick cement plaster (1:4) ceiling including watering & curing etc. complete with cost, conveyance royalties & taxes of all materials & cost of all labour with T & P required for the work etc. all complete in all respect as per the Direction of the Engineer in charge. FLOORING
Supplying, fitting and fixing vitrifed tile of size 600mm x 600mm Premium grade in floors conforming to IS 13755 laid on 20mm thick cement mortar(1:4) and filling joints with white cement of approved quality including cost of all materials, labour T&P,Conveyence etc . complete required for the work as per the direction of engineer-in-charge. a)TERRACE FLOOR
Supplying, fitting and fixing tiles in dados, skirting and risers of Steps on 12mm thick cement paster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing including cost of precast tiles, labour T&P,Conveyence etc . complete required for the work as per the direction of engineer-in-charge. B)TERRACE FLOOR
Painting 1 coats with approved cement primer on plastered surface (water bound) to after cleaning the surface including cost of conveyence and taxes of all materials including the cost of primer labour and T & P etc required for the work all complete in all respect as per direction of Engineer in charge. A)Quantity referred from Inside plaster 12 mm thick
B) Quantity referred from Outside plaster 16 mm thick
C) Quantity referred from Celing plaster 6 mm thick
Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials labour T & P etc. as per direction of Engineer -In -charge. A)Quantity referred from Inside plaster 12 mm thick
B) Quantity referred from Celing plaster 6 mm thick
Painting 1 coats with approved Plastic emulsion Paint of approved shades on new work to give even shade including cost of paint, cost of labour and T & P etc required for the work all complete in all respect as per direction of Engineer in charge. A)Quantity referred from Inside plaster 12 mm thick
Painting 1 coats to outside surface of walls etc approved shade and colour using weather coat to the surface after cleaning, including cost of conveyence and taxes of all materials including the cost of weather coat labour and T & P etc required for the work all complete in all respect as per direction of Engineer in charge. A)Quantity referred from Outside plaster 16 mm thick
Supplying , fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.
2.5 cm thick grading concrete (1:2:2) on roof slab with 6 mm size hard granite chips.on new work per 1 sqm.
D) ELECTRIFICATION WORKS OF SHOPPING COMPLEX:- Supplying and fixing of following sizes of PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required. i)20mm size A)G.F.
Recessed wiring to light point / exhaust fan point / with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 6 Amp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on modular GI box with modular base & cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels /HPL/ V Guard ) Group C. A)G.F
Recessed wiring to Ceiling fan point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 6 Amp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on modular GI box with modular base & cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havells /HPL/ V Guard ) Group C. A)G.F
Recessed wiring to for 5/6 amp socket outlet with 2x1.5 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked in 20mm dia non metallic PVC conduit with 6 amp ,250 V clip in type switch ISI marked mounted on modular GI box with modular base & cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havells /HPL/ V Guard ) Group C. A) G.F
Recessed wiring to for 6pin 16 amp socket outlet with 5 amp ,250 V clip in type switch ISI marked mounted on modular GI box with face plate & cover of suitable size ,with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. A) G.F
Recessed wiring to submain in 4x 6 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS -694/1990 IN 32 mm dia non metallic heavy duty PVC conduit 1.6 mm thick along with 2x4 sqmm FR-PVC insulated single core multi strand copper conducter as earth wire required. A) G.F
Recessed wiring to submain in 2x 1.5 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS -694/1990 IN 20 mm dia non metallic heavy duty PVC conduit 1.6 mm thick along with 1x1.5 sqmm FR-PVC insulated single core multi strand copper conducter as earth wire required. A) G.F
Supply and fixing of following way three pole and neutral sheet steel, MCB distribution, 415 V on surface / recess complte with tinned copper bus bar, neutral bus bar, earth bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc as required (but without MCB/RCCB/Isolator) A) G.F
Supply and fixing of following way single pole MCB with sheet steel enclosure distribution board on surface / recess complete with tinned copper bus bar, neutral bus bar, earth bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc as required (but without MCB/RCCB/Isolator) A) G.F
Supply and fixing of following rating 240 V Minature circuit breaker (mcb) having a sensitivity current upto 10KA in the existing MCB DB ISIS marked complete with connection testing and commissioning etc as required. A) G.F
Supply and fixing of following rating 240 V RCBO having a sensitivity current upto 100mA in the existing MCB DB ISIS marked complete with connection testing and commissioning etc as required. A) G.F
Supplying and making end termination with brass compression gland and aluminium lugs for the following size of PVC insulated and PVC sheathed/XLPE aluminum cable of 1.1 KV as required. i) 3.5 x 150sqmm A) G.F
Earthing with G.I earth plate 600x600x6mm thick ISI marked including accessories and providing masonary with cover plate having lockking arrangement and watering pipe etc(but without charcoal and salt) as required. A) G.F
Earthing with G.I earth plate 600x600x6mm thick ISI marked including accessories and providing masonary with cover plate having lockking arrangement and watering pipe etc(but withoutcharcoal and salt) as required. A) F.F
Extra for using charcoal and salt for GI or copper plate earth as required A) F.F
Supplying and Laying 25mmx 6mm GI earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc as required. A) F.F
Supplying and Laying 25mmx 5mm GI earth strip on surface or in recess for connection etc as required. A) F.F
Supplying and fixing of following piano type switch / socket on the existing switch box / cover including connections etc as required i)5 / 6 amp switch A) F.F
ii)15 / 16 amp switch A) G.F
iii)3 pin 5 / 6 amp socket outlet A) F.F
iv)6 pin 15 / 16 amp socket outlet A) F.F
v)S/F of Urea Ceiling Rose ISI marked. A) F.F
Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting of all sizes complete with all accessories and tube etc. directly on ceiling wall, including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required. A) F.F
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. A) F.F
Supply, Installation, Testing and Commissioning of resistance type ceiling fan regulator, in existing switch box including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor, earthing the regulator as required A) F.F
Providing and fixing of lightening conductor finial made of 25mm dia 300mm long copper tube having single prong at top with 85mm dia 3mm thick copper base plate including holes etc complete as required. A) T.F
Providing and fixing of testing joint made of 20mmx3mm thick copper strip 125 longwith 2 nos of GI bolts check nuts and spring washer etc complete as required A) T.F
Providing and fixing of copper tape 20mmx3mm thick on parapet or surface of wall for lightening conductor complete as required.( for horizontal run) A) T.F
Providing and fixing of copper tape 20mmx3mm thick on parapet or surface of wall for lightening conductor complete as required.( for vertical run) A) T.F
Reveting, sweating and soldering of copper /GI tape(with anaother copper /GI tape , base of the finial or any other metallic object) as required. A) T.F
Supplying and fixing of 16 / 18 SWG metal box of following sizes (nominal size) on surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required. A) T.F
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_580145.pdf
techsummary_580145.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 10.81 MB
BOQ_580145.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid