Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹35.2 L+₹3.1 L (9.72%)Rejected-Finance | L2 | Rejected-Finance BEING OTHER THAN L1 | |
| 3 | L3₹39.4 L+₹7.3 L (22.9%)Rejected-Finance MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | L3 | Rejected-Finance BEING OTHER THAN L1 | |
| 4 | L4₹46.2 L+₹14.2 L (44.2%)Rejected-Finance CHATAI SHEEP WARD NO 07 NEW MARKET ROAD AHIWARA DURG CHHATTISGARH 490036 | DURG | CHHATTISGARH | 490036 | L4 | Rejected-Finance BEING OTHER THAN L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Enlisted in Cat b (iii) |
Tender Value
₹32.1 L
EMD Value
₹54,180
Closing Date
5 May 2021, 6:00 pmClosed
GE EAST AGRA
Garrison Engineer East Agra, Gwalior House, 62 Taj Road Agra Cantt
OUTSOURCING FOR MANNING OPERATION OF RANI LAXMI BAI AND GWALIOR ROAD 33 11 KV MAIN RECEIVING STATIONS UNDER GE EAST AGRA
2021_MES_436375_1
9350/E8
Open Tender
Civil Works
Item Rate
335 days
AGRA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE EAST AGRA
₹54,180
Yes
5 Jun 2021
15 Apr 2021
12 May 2021
15 Apr 2021
5 May 2021
29 Apr 2021
Amount
Note: Please refer schedule 'A' notes given on serial page No. 13 to 15 before quoting the tender.
M & L for providing operational staff for operation and manning and routine maintance, minor repair and upkeep of 33 KV RLB MRS 4 MVA Main receiving Station, 33 KV switch yard, having 33 KV outdoor VCBs, indoor remote control panels, 11 KV incoming/outgoing VCBs and OCBs by deputing operating staff in 3 shifts, recording of parameters in log sheet, maintaining of all type of tripping record of 33 KV VCBs including all incoming and outgoing feeders of complete sub Stn, labour for repair of minor defects as and when required and servicing of all fixed and moving parts of isolator, VCBs, drop out fuses etc, including carrying out all tests of transformer and Earth Resistance value of all equipments during once in 3 months and maintaining complaint record in complaint register and detailment of complaint staff complete all as specified and directed by Engr -in-charge. The details of minimum staff in each shifts are as under:-
SBA/Skilled electrician - 01 No
Brief of Sub Station (a) Transformer 3.15 MVA, 33/11KV - 02 Nos (b) Transformer 63 KVA, 33/.433 KV - 01 Nos (c) 33 KV switch yard -01 No (d) 11 KV VCBs -13 Nos (e) 33 KV in door remote control panel - 03 Nos (f) 33 KV outdoor VCBs - 03 Nos (g) Battery Bank 30 volt DC-01 No having 02 volt 45 AH battery -15 Nos
M & L for providing operational staff for operation and manning and routine maintance, minor repair and upkeep of 33 KV Gwl Road MRS, 3 X 3.15 MVA Main receiving Station, 33 KV switch yard, having 33 KV outdoor VCBs, indoor remote control panels, 11 KV incoming/outgoing VCBs and OCBs by deputing operating staff in 3 shifts, recording of parameters in log sheet, maintaining of all type of tripping record of 33 KV VCBs including all incoming and outgoing feeders of complete sub Stn, labour for repair of defective parts as and when required all fixed and moving parts of isolator, VCBs, drop out fuses etc, including carrying out all tests of transformer and Earth Resistance value of all equipments during once in 3 months and maintaining complaint record in complaint register and detailment of complaint staff complete all as specified and directed by Engr -in-charge. The details of minimum staff in each shifts are as under:-
SBA/Skilled electrician- 01 No
Brief of Sub Station (a) Transformer 3.15 MVA ,33/11KV - 03 Nos, (b) 33 KV switch Yard - 01 Nos, (c) 11 KV VCBs - 10 Nos, (d) 33 KV indoor remote control panel - 03 Nos, (e) 33 KV outdoor VCB - 03 Nos, (f) Battery Bank 30 volt DC-01 Nos having 2 volt 45 Ah battery -15 Nos
M & L for providing operational assistance / trained helper for tradesman for operation of 33 KV Main MRS / Electrician working on day to day maintenance to over head lines, UG cables, transmission, distribution systems, electrical controls, street lights etc including carrying ladder, area cleaning etc as per site requirement or as directed by Engineer-in-charge for 33 KV RLB MRS and 33 KV Gwl Road MRS
NOTE FOR ITEM 2.00, to 3.00 (i) Carefully monitoring of 33 KV take over point of TOP and also carefully monitoring of all the GODOs in the 33/11 KVA yard. (ii) Monitoring of battery charging bank for DC supply to numbers of relay and motors of VCB to ensure tripping. (iii) To monitor all power and distribution transformers connected to main transformer. (iv) To switch On/OFF the security lights at MRS complex as per time Schedule fixed by Engineer-in-Charge. (v) In case of any major fault in the equipments which is beyond the control of the operator, he will immediately intimate the same to the Engineer-in-Charge/JE. (vi) The operator shall monitor and Maintain records of load/power factor complaint etc in detail and submit complete details to Engineer-in-Charge/JEs for resolution, urgent complaints if any will immediately be intimated to Engineer-in-Charge/JEs (vii) The contractor shall arrage 3 mobile set with Cell facility for intercommunication with all above 3 teams, bill of these mobile shall be bear by contractor. (viii) The department can deploy above staff to other location, with department DEL under GE (E) Agra as per site requirement but number of staff shall not be less than specified in Item No 2,3,&4 above. (ix) Electrcian should have minimum 3 year experience in handling of HT/LT electrical switch gear. (x) All sraff deployed by contractor shall wear half reflective jacket having self glow strip and marking as directed by Engineer in Charge/GE. (xi) Necessary T&P such as magger, ladders, hand gloves, palir, screw driver, discharge rod etc required for day to day requirements of electrician/ helpershall be arrange by the Contractor. (xii) Cleaning of MRS and surrounding area including vegetation, grass with help of shawls, grass cutter etc necessary T&P and safety equipment shall be arrange by the Contractor.( xii ) Recovery from contractor:-a. Recovery Rs 500.00 per day for non production of adequate tools/safety equipement. B. Recovery Rs 1600/- per shift against absentee of /electrician/operators and Rs 1500/- per shift for helper.
virendera singh
DURGAI ELECTRICALS
M/S SANTOSH CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .