| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹25.0 LAccepted-AOC 34 1 12 2F SAINIK VIHAR DEORI ROAD AGRA UP 282007 | AGRA | UTTAR PRADESH | 282007 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹26.9 L+₹1.0 L (3.95%)Rejected-AOC | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹27.6 L+₹1.7 L (6.47%)Rejected-AOC 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L-3 | Rejected-AOC L-3 |
| Sl No | Description | Qty | Unit | M/S OM Enterprises L1 | LUCKY SALES CORPORATION L2 | GUPTA ENGINEERING WORKS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Disconnecting electric connection of Split/Window/cassette type air conditioner ,watercooler/Deep freezer of any capacity from any height and taking down/ keep aside servicing the same cleaning inside, cleaning of fins by means of airblower and water with pressure jet , cleaning of air filter, remove dust from body, tightening of loose nut bolt, washer, rubber gasket,tightening of loose wiring, loose connection and repair of parts, wornout nutbolt, washers, gasket,valves,temperature sensor,swing motor etc and necessary cutting, welding/soldering works with replacement of rusted body with new MS/GI Sheets of suitable size and making the applience fully functional and re-assembling and re-installation in same/other position and testing complete all as specified and directed.
Note: (i) .All the repairs shall be carried out at MES store yard including transportation of equipment shall be contractor's own arrangment.(ii) All new parts will be measured and paid as supply only under the respective item 2.00 to 5.00 listed herein below. | 186 | Each Job | 600 ₹1,11,600 | 300 ₹55,800 Lowest | 450 ₹83,700 |
| 2.00 | Supply only starting/running capacitor of 5 to 30 mfd capacity for compressor of Window/Split Type ACs( 1.5 TR/2.0 TR) complete all as specified and directed. | 30 | Each | 140 ₹4,200 Lowest | 360 ₹10,800 | 150 ₹4,500 |
| 3.00 | Supply only starting/running capacitor of 30 to 80mfd capacity for compressor of Window/Split Type ACs( 1.5 TR/2.0 TR) complete all as specified and directed. | 25 | Each | 150 ₹3,750 Lowest | 330 ₹8,250 | 200 ₹5,000 |
| 4.00 | Supply only starting/running capacitor upto 5mfd capacity for Fan motor of Window/Split Type Acs ( 1.5 TR/2.0 TR) complete all as specified and directed. | 15 | Each | 50 ₹750 Lowest | 70 ₹1,050 | 50 ₹750 Lowest |
| 5.00 | Supply only remote hand set of window/split type air conditioner of capacity 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and directed. | 12 | Each | 250 ₹3,000 Lowest | 450 ₹5,400 | 300 ₹3,600 |
| 6.00 | Supply and fixing in repair temperature sensor for 1.5 TR / 2 TR window/split type AC of any type complete all as specified and directed. | 4 | Each | 200 ₹800 Lowest | 200 ₹800 Lowest | 250 ₹1,000 |
| 7.00 | Supply and fixing in replacement Air Filter suitable for Window/Split type Acs of 1.5 TR/2.0 TR Capacity complete all as specified and directed. | 15 | Each | 100 ₹1,500 Lowest | 150 ₹2,250 | 100 ₹1,500 Lowest |
| 8.00 | Supply and fixing in repair brass suction/discharge valve of size 1/4 ",3/8",1/2", 5/8" suitable for 1.5TR/2.0TR of split AC/window AC complete all as specified and directedd | 20 | Each | 250 ₹5,000 | 150 ₹3,000 Lowest | 300 ₹6,000 |
| 9.00 | Supply and fixing of drain pipe of 3 mtr length suitable for split type air conditioner of 1.5/2.0 TR of existing make complete all as specified and directed. | 15 | Each | 100 ₹1,500 Lowest | 150 ₹2,250 | 150 ₹2,250 |
| 10.00 | Supply and fixing in replacement compressor shut off valve of suitable size for window/split AC up to 2.00 TR capacity complete all as specified and directed. | 10 | Each | 120 ₹1,200 Lowest | 275 ₹2,750 | 150 ₹1,500 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
14 Feb 2026, 6:00 pmClosed
GE I RnD Delhi
MILITARY ENGINEER SERVICES GARRISON ENGINEER I RND LUCKNOW ROAD TIMARPUR DELHI 110054
REPAIR MAINTENANCE TO SUMMER APLLIANCES INCLUDING DESERT COOLERS WATER COOLERS AND OTHER CONNECTED ITEMS AT ADRDE AGRA AND REPAIR MAINTENANCE OF GEYSER CEILING FANS EXHAUST FANS AND INTERNAL ELECTRIC SUPPLY AT ADRDE AGRA UNDER GE I RnD DELHI
2026_MES_749848_1
GE/RND/T-36/AGR/2025-2026
Open Tender
Civil Works
Item Rate
240 days
Agra
As per tender documents
2 documents required · 2 mandatory
₹500
GE I RnD Delhi
₹60,000
31 Mar 2026
23 Jan 2026
16 Feb 2026
23 Jan 2026
14 Feb 2026
7 Feb 2026
Disconnecting electric connection of Split/Window/cassette type air conditioner ,watercooler/Deep freezer of any capacity from any height and taking down/ keep aside servicing the same cleaning inside, cleaning of fins by means of airblower and water with pressure jet , cleaning of air filter, remove dust from body, tightening of loose nut bolt, washer, rubber gasket,tightening of loose wiring, loose connection and repair of parts, wornout nutbolt, washers, gasket,valves,temperature sensor,swing motor etc and necessary cutting, welding/soldering works with replacement of rusted body with new MS/GI Sheets of suitable size and making the applience fully functional and re-assembling and re-installation in same/other position and testing complete all as specified and directed. Note: (i) .All the repairs shall be carried out at MES store yard including transportation of equipment shall be contractor's own arrangment.(ii) All new parts will be measured and paid as supply only under the respective item 2.00 to 5.00 listed herein below.
Supply only starting/running capacitor of 5 to 30 mfd capacity for compressor of Window/Split Type ACs( 1.5 TR/2.0 TR) complete all as specified and directed.
Supply only starting/running capacitor of 30 to 80mfd capacity for compressor of Window/Split Type ACs( 1.5 TR/2.0 TR) complete all as specified and directed.
Supply only starting/running capacitor upto 5mfd capacity for Fan motor of Window/Split Type Acs ( 1.5 TR/2.0 TR) complete all as specified and directed.
Supply only remote hand set of window/split type air conditioner of capacity 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and directed.
Supply and fixing in repair temperature sensor for 1.5 TR / 2 TR window/split type AC of any type complete all as specified and directed.
Supply and fixing in replacement Air Filter suitable for Window/Split type Acs of 1.5 TR/2.0 TR Capacity complete all as specified and directed.
Supply and fixing in repair brass suction/discharge valve of size 1/4 ",3/8",1/2", 5/8" suitable for 1.5TR/2.0TR of split AC/window AC complete all as specified and directedd
Supply and fixing of drain pipe of 3 mtr length suitable for split type air conditioner of 1.5/2.0 TR of existing make complete all as specified and directed.
Supply and fixing in replacement compressor shut off valve of suitable size for window/split AC up to 2.00 TR capacity complete all as specified and directed.
Supply and fixing of Swing motor suitable capacity for 1.5 TR / 2 TR window/split type ACs of any type/model complete all as specified and directed.
Supply and fixing in repair of copper tubing 1/4", 1/2",3/8" dia complete all as specified and directed.
M&L for detection and rectification of leakages in refrigerant line by nitrogen gas to find out leakage in window / split type AC(1.5/2.0TR),water cooler/Deep freezer/Refrigerator of any model/make and ensuring the complete systems leak proof flushing out nitrogen gas including charging/Topup of refrigerant gas R-134A / R 22/R-32 or any other refridgerant gas as required with appropriate quantity including testing for smooth functioning and re-assembling and re-installation in same/other position complete all as specified and directed.
S&F in repair of PCB for indoor/Outdoor unit of Inverter Split ACs of any type of capacity 1.5/2.0 TR including removal of old PCB complete all as specified and directed.
S&F in repair of PCB for window AC 1.5/2.0 TR Inveter ACs of any type and capacity including removal of old PCB complete all as specified and directed.
M&L for dismantling of defective PCB of window/Split AC of 1.5/2.0 TR capacity of any make & type and refixing after repairing the PCB to ensure proper functioning of the AC complete all as specified and directed.
S&F in replacement Thermostat Switch as per exsisting size & model of Window/Split 1.5 TR/2.0 TR Capacity including taking out unserviceable Thermostat Switch from AC complete all as specified and as directed.
S&F in replacement of Thermostat sensor of AC (Window/Split Type) 1.5 /2.0 TR and removal of unserviceable Thermostat sensor from AC complete all as specified and as directed.
M&L for removing burnt wiring kit of window /spilt type ACs, water cooler replace with best quality new wiring kit suitable type of PVC insulated copper conductor cable including thimbles sleeves of suitable size & shape complete all as specified and directed.
S&F in repair of PVC blower of Split Type AC 1.5/2.0 TR Capacity of approved Make and required Size to suit existing AC incuding removal of unserviceable blower complete all as specified and as directed.
All as per item No 20.00 above but for window AC ( 1.5/2.0TR)
M&L for taking down of window/Split type AC of any capacity or model from any height/ any floor up to three storey building and shifting to another location in the same or other building and refixing at New Location including testing of leakage and charging/top up of specified gas as per the make of the AC and make it fully functional again at new location complete all as specified and directed.
S&F in repair of cooling coil complete with fins made of copper suitable for Window type AC (1.5/2.0 TR) as per existing model/size including removing of old cooling coil complete all as specified and directed.
All as per item No 23.00 above but for split AC ( 1.5/2.0TR)
M&L for dismantling of unserviceable/worn out reciprocating/hermetically sealed unit compressor from Deepfreezer/Refrigerator and replacement with new one compressor, suitable for existing model/make including brazing with suction and discharge line, checking the system for leak proof and inclduing charging of refrigerant gas R-134 A /R-32 or required type in appropriate qty after making vaccum the complete system and testing for proper functioning complete all as specified and directed.
M&L in replacement of Strainer with Capillary tube/capillary tube of Window/ Split Type AC 1.5 /2.0TR Capacity including taking out unserviceable Capillary Tube from AC complete all as specified and as directed.
Supply and fixing of PVC nylon imbraided pipe15 mm dia for condensed water drain fitted on wall including all fittings complete all as specified and directed.
S&F in repair of foam insulation heavy duty for 1.5TR/2.0TR split ACs refrigerant line as per exsisting size complete all as specified and directed.
M&L for refrigerent gas charging (Top up)with required quantity of refrigerant R-22/R 32/R 407/R 410 or any other refrigerent as per the requirement in window & split ACs,water cooler,Deep freezer,Refrigerator of any capacity and make for its smooth functioning after carrying out vaccum and pressure test including necessary soldering/brazing to prevent leakage all as specified and directed.
Taking out defective condenser fan motor from window type AC of capacity 1.5/2.0 TR transporting defective motor of any make &Type/ capacity from site at any height to contractor workshop dismantling the burnt winding & rewinding the blower motor with the required size of super enameled copper winding wire of suitable gauge including insulation, varnishing, greasing, testing complete and transporting to back to site and refixing complete all as specified and directed.
All as per item No 30.00 above but for condenser fan motor of split AC (1.5/2.0TR)
All as per item No 30.00 above but for blower fan motor of split AC ( 1.5/2.0TR)
Dismantling of defective condensing unit ( outdoor unit) of spilt type AC of 1.5 TR capacity and supply & fixing new condensing unit complete with compressor, condensing coil, coil frame, wiring kit and running capacitor, relay, condensing motor with blade complete all as specified and directed.
M&L in replacement of Starting Relay of AC (Window/Split Type) 1.0/1.5 TR/2.0TR Capacity including taking out unserviceable Relay from AC complete all as specified and as directed.
Taking down defective condenser fan motor of 1.5/2.0 TR Split AC S&F new condenser fan motor as per exsisting make/model with copper winding complete all as specified and as directed by Engineer-in-Charge.
Dismantling of defective indoor unit of 1.5 TR capacity split type AC and supply & fixing new indoor unit of the same capacity with blower motor, front grill and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required all as specified and directed.
S&F in repair of condensing coil complete with fins made of copper suitable for Window type AC (1.5/2.0 TR) as per existing model/size including removing of old condencing coil complete all as specified and directed.
All as per item No 37.00 above but for split AC ( 1.5/2.0TR)
S&F in repair of stand mounting bracket (heavy duty) for split AC (1.5/2.0TR) made of 2mm thick high steel power coating for rust prevention suitable for wall/floor mounted out door AC unit,including fixing with suitable fasteners on exsisting location/building (upto three storey) complete all as specified and as directed.
Taking down defective condenser fan motor of 1.5/2.0 TR window AC and S&F new condenser fan motor as per exsisting make/model with copper winding complete all as specified and as directed by Engineer-in-Charge.
Taking down defective condenser fan blade of 1.5/2.0 TR window/split AC and S&F new condenser fan blade as per exsisting make/model with copper winding complete all as specified and as directed.
S&F Sheet metal enclosure with socket plug top and MCBs single pole with a two pin and earth plug and socket complete with one single pole MCB of "C" series of capacity 20 Amp including taking out the old one complete all as specified and directed.
M&L metal clad Industrial plug top ISI mark 2 pin with earth 250 Volts including taking down old one complete all as specified and directed.
Supply and fixing in repair MCB SP 16-32Amps rating of 'C' series to be housed in industrial socket complete all as specified and directed.
S&F sub main wiring using approved colour coding (Phase-red, Neutral-black, Earth-green) complete with 2 x single core FRLS PVC insulated and unshealthed stranded copper conductor cable 4 Sqmm as current carrying conductor and one run of 4.0 Sqmm as earth contunity conductor, voltage rating 1100 volt, ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with standard accessories including taking down old one complete all as specified and directed. Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and PVC conduit shall be measured as one unit.
M&L Metal clad Industrial socket ISI mark with earth 250 Volts including taking down old one complete all as specified and directed.
M&L for dismantling of unserviceable/worn out hermetically sealed unit compressor from window AC and replacement with new one compressor, suitable for existing model/make of capacity 1.5/2 TR window type AC including brazing with suction and discharge line, checking the system for leak proof and inclduing charging of refrigerant gas R-134 A /R 22 /R-32 in appropriate qty after making vaccum the complete system and testing the AC for proper functioning complete all as specified and directed.
All as per item No 47.00 above but for split AC ( 1.5/2.0TR)
S & F of plywood 12 mm thick prelaminated,BWR, grade 1, one side decorative teak veneers and other side commercial veneered finished fixing in small pieces around window AC to make air tight on wall/window including necessary carpenter work complete all as specified and directed.
S&F of reverse cycle solenoid valve in split type AC 1.5 / 2 TR capacity with necessary extension to suction/ discharge copper tubing & toggle switch complete all as specified and directed.
S&F of 05 KVA wall mounted type stabilizer for automatic operation single phase naturally air cooled indoor type designed for input variation between 170Vto 285V and with output voltage stabilizer at 230V with accuracy of +/-2.5% complete and taking out old unserviceable stabilizer complete all as specified and directed.
S&F in repair of PCB with high & low voltage cut off suitable for 4 KVA/5 KVA voltage stablizers of any make complete all as specified and directed.
S&F in repair of power transfromers suitable for voltage stablizers of capacity 4/5 KVA complete all as specified and directed
M&L for removing the desert cooler from its existing position at any height from stand or pillar, removing the side panels, taking out unsv wood wool pads or loose pads including supporting jali(HDPE plastic /steel wire mesh)and disposed to a distance not exceeding 50 metres away as directed by EIC and spray painting with synthetic enamel paint of approved color (inside and outside) including one coat of black japan paint in side the base of tank tank after preparation of old painted surfaces and reassembling and fixing in position including oiling and greasing of fan kit, water pump motor, refixing wood wool pad secured with new HDPE soft mesh complete all as specified and directed.
Taking down of unserviceable detachable type perforated side panel from exsisting desert coller S&F new perforated side panel made out 22 gauge PGI sheet suitable for desert cooler over all size of 0.750x0.750x0.910 mtr complete all as specified and directed.
S&F in replacement of unserviceable wood wool pads with supreme quality white wood wool (set of three) in repair including PVC pipe pieces 03 Nos of required length & dia for connection of water distributor/ elbows of desert coolers of complete all as specified and directed.
Supply and fixing in replacement of supreme quality white wood wool in loose suitable for industrial desert cooler complete all as specified and directed.
S&F in replacement of unserviceable honeycomb wooden wool pads with supreme quality honeycomb pad (set of three) in repair including PVC pipe pieces 03 Nos of required length & dia for connection of water distributor/ elbows of existing coolers(Plastic body) complete all as specified and directed.
Taking out defective exhaust fan of 16"/18"of any make from desert/industrial cooler and transporting it to contactor's workshop, opening of fan motor , taking out rotor, cutting out the burnt winding ,cleaning the slots and rewinding of the same with the existing size of super enameled copper winding wire including insulation varnishing, greasing, painting reassembling testing and fixing in position complete all as specified and directed.
Taking out defective desert cooler fan of capacity upto 300watt, 1500rpm capacity from desert cooler rewinding of the same with the existing size of super enameled copper winding including varnishing, greasing, painting reassembling testing and fixing in position complete all as specified and directed.
S&F in repair of switch piano flush button single pole one way 15 Amp, 240 Volts in desert cooler conforming to IS 3854 ISI marked.
Taking down unserviceable exhaust fan (heavy duty) of 16"/18" sweep size,2800 rpm from desert cooler, supply and fixing new exhaust fan (copper winding) of same capcity complete with fan blade ,fixing in the same position by providing new nut, bolts, washer, MS frame/side arms and rubber pads etc including testing complete all as specified and directed.
Taking down unserviceable exhaust fan of Plastic desert coooler of existing type(Symphony silenzo 120i model), supply and fixing new exhaust fan (copper winding) of same capcity complete with fan blade ,fixing in the same position by providing new nut, bolts, washer, side arms and rubber pads etc including testing complete all as specified and directed.
Supply and laying or fixing or passing two core 4 sqmm stranded conductor through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armouredwith galvanised steel wire or tape and overall PVC sheathed and taking out old unseriviceable wire complete all as specified and directed.
S&F in repair of Polycarbonate Plug top 3 pin 6 Amp complete all as specified and directed.
S&F in repair of Polycarbonate Plug top 3 pin 16 Amp complete all as specified and directed.
Supply and fixing in renewal of desert cooler submersible pump having power of 18/20W,and out put 1200 Ltr/hr single phase 230 Volt AC, (ISI marked) suitable for evaporating type desert cooler including fixing clamp inside the desert cooler complete all as specified and directed
Supply and fixing in renewal of desert cooler submersible pump having power of 40W & 3500 Ltr/Hr output, single phase 230 Volt AC, (ISI marked)suitable for Industrial type cooler including fixing clamp inside the Industrial type cooler complete all as specified and directed
Taking down unserviceable exhaust fan frame S&F and fan frame and supporting Leg for exhaust fan including nut, bolts, washer Rubber, clamp etc complete Set complete all as specified and directed.
S&F in repair of capacitor upto 4.5 Mfd for desert cooler fan complete all as specified and directed.
S&F of plywood 6mm thick, cut to shape as required on site fixing around wall/ window/ cooler opening with and including necessary nuts & bolts/ screws complete all as specified and directed.
Supply and fixing in repair of steel multi wing exhaust fan blade set of best quality as per existing type and size of 16"/18" sweep heavy duty for desert cooler complete all as specified and directed.
Taking down unserviceable fresh air fan motor (Fan kit) from desert cooler and supply and fixing new fresh air fan kit of copper winding (150-300Watt),1500 RPM,230 Volts single phase as per exiting sample/ size and fixing in same position by providing new nut, bolts, washer, MS frame/side arms and rubber pads etc including testing complete all as specified and directed.
Supply and fixing in replacement of evaporator coil ISI marked suitable for water cooler of any make/type/ capacity including all fixing accessories and making connection / detecting leakage and gas charging etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair of starting/running capacitor upto 30Mfd for blower motor of water cooler having capacity of 40/80 & 60/120 ltr complete all as specified and directed.
S&F in repair of starting/ over load Relay for Water Cooler having capacity 40/80 and 60/120 Litres of any make including removing unserviceable relay complete all as specified and directed.
M&L for removing of perished body of desert cooler over all size 0.750x0.750x0.910 mtr from existing site and replace the same with new body made out of 22 gauge PGI sheet by means of fabrication welding/ jointing having tank size Approximately 0.750x0.750x0.230 mtr and front grill made out of 26 gauge PGI sheet 0.460x 0.460mtr size for air flow direction, 03 Nos perforated sheet side panels size Approximate 0.680x0.610mtr of each and also having electric control panel consisting two nos 5amp switch, one rotary speed regulator switch complete and duly painted with two coats of synthetic enamel paint over one coat of primer internally and externally including fixing the exiting fan kit & Pump motor received from old unserviceable Desert Cooler including all electrical connections, testing and commisioning complete all as specified and directed.
Taking out the unserviceable sealed compressor unit from water cooler and S&F New Sealed compressor unit of existing sample, suitable for 40/80 Ltr &60/120 Ltr capacity of water cooler replace with new compressor (duly tested) and checking the complete system for leak proof and including charging of refrigerant gas R-134 a in appropriate quantity and testing for smooth functioning complete all as specified and directed.
Taking out defective water cooler blower motor any make/size from cooler upto 60/120 ltr capacity , cutting out the burnt winding cleaning the slots and rewinding of the same with the existing size of super enameled copper winding wire including greasing, reassembling complete all as specified and directed.
S&F in replacement of steel body desert cooler fan regulator of existing type and size including removing old regulator complete all as specified and directed.
S&F in repair of thermostat switch /relay suitalbe for water cooler having capacity 40/80 and 60/120 Litres of any make including removing unserviceable one complete all as specified and directed.
S&F in repair of condenser coil(copper tubing) for Water Cooler having capacity 40/80 and 60/120 Litres of any make including removing unserviceable condenser coil complete all as specified and directed.
Taking out the burnout blower motor from water cooler and S&F New single phase blower motor (copper winding) of existing sample/size suitable for 40/80 Ltr & 60/120 Ltr capacity of water cooler complete all as specified
S&F in replacement defective push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed.
S&F in replacement steel waste water tray suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed.
Material and labour for disconnecting electric connection, taking down/ keep aside the outdoor unit of VRF type AC having power supply upto 10 KW including stabilizer of any make and capacity,servicing the same as cleaning inside, by mean of cleaning of filter, remove dust from body, tightening of loose nut bolt, washer, rubber gaskit and tightening of loose wiring, loose connection, replacement of wornout, nutbolt, washers, gaskits etc and necessary cutting, welding/ soldering works with replacement of rusted body parts with new MS/GI Sheets of suitable size and made functional the equipment fully and Re-installation in position and testing complete all as specified and directed.
Taking down ceilling fan/exhaust/air circulating fan of any size or make by disconnecting electric connection and removing from site for rewinding,servicing, painting of fans and refixing the same position or complete all as specified and directed.
Cleaning, washing, greasing, oiling and varnishing of ceiling fan/exhaust fan/air circulator fan of any size and make complete all as specified and directed.
M&L for opening and rewinding with super enamelled copper winding wire of existing size of ceiling fan 1200/1400 mm sweep complete all as specified and directed. Note : Cost of transportaion from site to workshop in deemed to be includedin quoted rates.
All as per ser item No 89.00 here-in-before but for exhaust fans/wall mounted fan of any size (200mm/250mm/450 mm) sweep.
M&L for replacement of defective ball bearing for ceilling fan of 1200/1400 mm sweep size (Bearing make/size SKF-6201/6202/ or equivalent) complete all as specified and directed.
M&L for replacement of defective capacitor of size 2.5/3.5 mfd for any type of fans suitable for 250 V including making connection complete all as specified and directed.
M&L for replacement of flexible copper conductor cable 3 core PVC insulated & PVC sheathed 1100 Volts grade size of cable 23/0.0076 complete all as specified and directed.
M&L for painting of ceilling fans any make of size upto 1400 mm at site with one coat of superior quality synthetic enamelled spray paint of approved make by spraying, filling cavities with filler after preparation of surface and wirting letter as per existing such as (MES AC12345) with black systhetic enameled paint 1" high on both sides of fans all as specified and directed.
S&Fin repair of Metal Exhaust fan AC single phase 230 volt of size 380 mm sweep, with minimum 1300 RPM with louvers and shutter connecting up including provision of cable from ceiling rose complete all as specified and directed.
S&Fin repair of Metal Exhaust fan AC single phase 230 volt of size 450 mm sweep with minimum 2400 RPM heavy duty with louvers and shutter connecting up including provision of cable from ceiling rose etc complete all as specified and directed.
S&Fin repair of wall mounted fans 230 volts with minimum 1300 RPM single phase oscillating 250 mm sweep suitable for wall mounting complete all as specified and directed.
S&Fin repair of PVC ventilation fan, working on single phase, 230 Volts, 50 Hz of sweep 200 mm with louvers with minimum 1300 RPM complete including fixing arrangement, grouting of Bolts in wall etc all as specified and directed. Note :- For the item 97.00 to 98.00 : Old unservicealbe fans shall be deposited in MES store yard.
Taking down existing unserviceable/old point wiring concealed/surface including fitting fixtures ,ceiling roses, pendant/angle holders, regulators, sockets,switches but excluding PVC conduit etc complete all as specified and directed
Material and labour for point wring ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with FRLS PVC insulated and unshealthed stranded copper conductor cable 1.5 sqmm single core conforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537(part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of suitable thickness including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primer with top cover 3 mm thick bakelight laminated sheet with brass screws and Cup washer with all assessories including FRLS PVC insulated and unshealthed stranded copper conductor cable 1.5 sqmm single core in green colour as earth wire connected to earth dolly complete all as specified and directed .
One light/fan/exhaust fan point/call bell point controlled by 1 No,one way 5/6 Amp switch.
One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on same board along with other switches ,fan regulator etc.
One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on independent board.
One light point controlled by two 2-way switches
Material and labour for point wring ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with FRLS PVC insulated and unshealthed stranded copper conductor cable 1.5 sqmm single core conforming to IS 694 in existing conduit including FRLS PVC insulated and unshealthed stranded copper conductor cable 1.5 sqmm single core in green colour as earth wire connected to earth dolly complete all as specified and directed . NOTE: PVC conduit, Pressed steel Sunk box and phenolic laminated sheet if required ,measured and paid seperatly.
One light/fan/exhaust fan/call bell point controlled by 1 No,one way 5/6 Amp switch.
One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on independent board.
Material and labour for point wring ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete for one socket outlet 15 Amp on independent board with FRLS PVC insulated and unshealthed stranded copper conductor cable 2.5 sqmm single core conforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537(part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primer with top cover 3 mm thick bakelight laminated sheet with brass screws and Cup washer with all assessories including FRLS PVC insulated and unshealthed stranded copper conductor cable 2.5 sqmm single core in green colour as earth wire connected to earth dolly complete all as specified and directed .
Material and labour for point wring ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete for one socket outlet 15 Amp on independent board with FRLS PVC insulated and unshealthed stranded copper conductor cable 2.5 sqmm single core conforming to IS 694 in existing conduit including FRLS PVC insulated and unshealthed stranded copper conductor cable 2.5 sqmm single core in green colour as earth wire connected to earth dolly complete all as specified and directed .
S&F switch piano flush button single pole two way 6 Amp, 240 Volts conforming to IS 3854 ISI marked .
S&F switch piano flush button single pole one way 6 Amp, 240 Volts conforming to IS 3854 ISI marked.
S&F for socket outlet, 5 Pin, 6 Amp flush type conforming to IS 1293 ISI marked including.
S&F for socket outlet, 3 Pin, 15 Amp flush type conforming to IS 1293 ISI marked including taking down old one.
S & F ceiling rose, surface Bakelite,isolated body three terminals including taking down old one. complete all as directed.
S&F Electronic fan regulator steped type (flush type) 240 volt ,50Hz ,single phase on existing phenotic laminated sheet including taking down old one and connecting complete all as specified and directed.
S& F forcast iron /pressed steel terminal rectangular box 60mm deep of following size for mounting switches,sockets ,regulator etc. with 3mm thick plastic laminated sheet cover of size rectangular complete including taking down old one.
All as per item No. 112.00 here in before but for size 150x75mm
All as per item No. 112.00 here in before but for size 150x150mm
All as per item No. 112.00 here in before but for size 200x150mm
All as per item No. 112.00 here in before but for size 200x250mm
S&F rigid medium PVC conduit of 25 mm dia exclusive of boxes out inclusive of all tees, bends, elbows, reducers, bell mouth tubes and fixing accessories such as coulers locknuts, saddles, pipe hooks of size including cutting of shape and flushed in wall where requiired and repairs.
S & F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthed stranded copper conductor cable 6 sqmm as current carrying conductor and one run of 6.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm with standard accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 6 sqmm all as specified and directed including taking down old one Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.
Supply & fix ventilation fan, working on single phase, 230 Volts, 50 Hz of sweep 200 mm with louvers with minimum 1300 RPM complete including fixing arrangement including grouting of Bolts in wall etc all as specified and as directed. Note:- Unserviceable fan deposited in MES store.
S&F sheet metal enclosures (MCB Distribution board) when MCB’s to be used single pole and neutral 8 ways 220 volt with 200 amps rated bus bar, double door with bus bar neutral link earth bar, Din rail, necessary blanking plated, including fixing DB flush in wall complete with making good disturbed surfaces as per existing specified and directed including taking down old one.
S&F MCB’s single pole, 10 KA ,6 Amp to 30 Amp 240 Volts,and of ''B'' series with required wiring connections and lugs etc including taking down old one complete all as directed.
S&F MCB’s single pole and neutal,32 Amp to 40 Amp 240 Volts,and of ''B'' series with required wiring connections and lugs etc including taking down old one complete all as directed.
S & F Decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient,18 watt,50 Hz including taking down the old fitting
S & F bulkhead light 10 watt suitable for outdoor application including taking down the old fitting.
M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire of 4 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe medium grade 15 mm bore for protection of GI wire from earth electrode to test point /machinery / equipment. supplying and laying charcoal dust comman salt PCC (1:2:4) type B1 using 20 mm graded stone agregrate chamber and RCC cover 54 cm X 54cm x50 mm thick (1:2:4) type B-1 using 20 mm stone agrigrtae ) reinforced with 8 mm dia TMT bars @ 75mm C/C both ways with mild steel handle 12 mm dia, using round bar ,PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No-3 of SSR part-1 including testing and taking out the old one complete all as specified and directed Note - Cost of GI wire and GI protection pipe up to a distance 7.5 M shall be included in quated rate of above Items.
S & F decorative, wall mounting, champagne gold finish fixture with plastic body suitable and including 9 W LED lamp B22 base complete including taking down the old holder complete all as directed by engg in charge.
S & F in repair LED bulb 9 W complete all as directed.
S & F Decorative ultra slim round profile 2 feet LED lighting fixture ,10 W ,with extruded polycarbonate, environmental friendly, energy efficient including taking down the old fitting
S & F in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten complete all as directed.
S&F in repair modular switch single pole one module 6 Amp
S&F in repair modular socket single pole two module 6 Amp
S&F in repair modular switch single pole one module 15/16 Amp
S&F in repair modular socket single pole two module 15/16 Amp
S & F in repair modular white cover plate with frame 4 module complete all as directed by engg in charge.
S & F in repair modular white cover plate with frame 6 module complete all as directed by engg in charge.
S & F in repair modular white cover plate with frame 8 module complete all as directed by engg in charge.
S & F in repair switch socket combination 2 in 1 , 5 & 15 amps complete all as specified and directed all as directed by engg in charge.
S & F TPN DBs DPX3 MCCB DBs suitable for DPX3 MCCB 160 Amps as incomer and 24 Nos MCB SP as outgoing 415 Vol,50Hz 8 way including taking down the old one complete all as specified and directed.
S & F MCCB TPN 160 Amp 415 V ,25 KA ,thermal magnetic type ,suitable for ICU between 80%-100%. Including connection with copper lugs including taking down old one complete all as directed.
Supply and fix in repair of 1.5 Sq mm FR LSH PVC insulated Single core multi strand copper wire complete all as specified and directed.
Supply and fix in repair of 2.5 Sq mm FRLS PVC insulated Single core multi strand copper wire complete all as specified and directed.
Supply and fix in repair of 4.0 Sq mm FRLS PVC insulated Single core multi strand copper wire complete all as specified and directed.
Supply and fix in repair of 6.0 Sq mm FRLS PVC insulated Single core multi strand copper wire complete all as specified and directed.
Supply and fix nylone sleeve, SIZE 50MM complete all as specified and directed.
Supply and fix nylone sleeve, SIZE 38MM complete all as specified and directed.
Supply and fix gypsum screw, size 50mm complete all as specified and directed.
Supply and fix gypsum screw, size 38mm complete all as specified and directed.
Supply and fix 5 -in-1, 6 Amp,240V, SS Combined unit with box (surface type) with two fixing holes incl fixing rawal plug & screws complete all as specified and directed.
Supply and fix 5 -in-1, 6/16 Amp,240V, SS Combined unit with box (surface type) with four fixing holes incl fixing rawal plug & screws complete all as specified and directed.
S&F in replacement of PVC connection pipe, 600 mm long with brass Nut with rubber washer suitable for hot/cold water complete all as specified and directed.
S&F in replacement of Plug Top 15 Amps complete all as specified and as directed.
Supply and fix in repair heating element 1500 watts capacity in round/ triangular shape bottom(Cup shape ) with rubber gasket and fixing to existing geyser complete all as specified and directed.
Supply and fix in repair brass geyser inlet/outlet assembly suitable for 25 Ltr capacity gyser including nuts, washers, check nuts and all connected items, complete all as specified and directed.
Supply and fix in replacement thermostat suitable for adjusting the temperature from 0 degree centigrade to 80 degree centigrade for 25/50 Ltr geyser including LED indicator lamp complete
Supply and fix in repair copper inner tank suitable for geyser of capacity 25 ltr with 6/9 numbers of holes all as specified and directed.
Syupply and fix in repair cover outer complete including top and bottom suitable for 25 Ltr capacity gyser of any make, shape and size as per existing but gauge of sheet not less than 22 SWG all as specified and directed.
S & F heavy duty steel bedded PVC polythene connection with 15mm dia 450mm long with CP brass nuts and leads PVC washer 02 Nos on each ends for Hot water including taking out the old one complete all as specified and directed.
S & F heavy duty steel bedded PVC polythene connection with 15mm dia 450mm long with CP brass nuts and leads PVC washer complete for Cold water complete including taking out the old one all as specified and directed.
M&L painting of complete outer body of storage type geyser of capacity 25 to 50 litres with two coat of synthetic enameled paint including preparing surface and including writing of MES No with black paint complete all as specified.
M&L GI tubing 15 mm dia medium grade ISI Marked, laid in trench/floor or fixed on wall with all fixing accessories etc all as required and directed.
Supply and replacement of Rubber Gasket flange as per site requirement for 25/50 ltr geyser including taking out the old one
S&F stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete of 15 mm dia including taking out old UNSV all as specified and as directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
TDR.pdf
Tender Documents • 1.42 MB
BOQ_839791.xls
BOQ • 0.95 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .