| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.7 CrAdmitted-Finance | -21.99% | ₹2.7 Cr | L1 | Admitted-Finance |
| 2 | Rejected-Technical AT PLOT NO 16 SWEETY COMPLEX P O GANGA NAGAR BHUBANESWAR KHURDA 751003 | BHUBANESWAR | KHURDA | ODISHA | 751003 | - | - | - | Rejected-Technical The bidder doesnt fulfills the minimum eligibility and qualifying criteria as per DTCN clause 111 and is found Dis-qualified |
Tender Value
₹3.5 Cr
EMD Value
₹3.5 L
Closing Date
30 Mar 2026, 5:00 pmClosed
CCE Phulbani RandB Circle Phulbani
Office of the CCE Phulbani RandB Circle Phulbani District Kandhamal PIN 762001
Addition and Alteration works for Construction of 300 bedded New Hospital Building at DHH Boudh
2026_EICCL_127177_1
CCE_R and B_PLB_22 of 2025_26
Open Tender
Civil Works - Buildings
180 days
Boudh
Please Refer Tender Documents
3 documents required · 3 mandatory
₹10,000
₹3.5 L
Yes
17 Apr 2026
16 Mar 2026
31 Mar 2026
16 Mar 2026
30 Mar 2026
16 Mar 2026
16 Mar 2026 - 26 Mar 2026
CIVIL WORK: First class Fly ash Brick masonry using bricks of size 23cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix (1:4) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
Ground floor
Providing and fixing 100mm thick dry wall partition with impact resistance board upto ceiling height consisting of GI frame and 2x12 mm thick tapered edge calcium silicate board having density 900kg/cum including providing and fixing of frame work made of special section power pressed/roll form of GI sheet with zinc coating of 120gms/sqm consisting of floor and ceiling channel 50mm wide having equa; flanges of 32 mm and 0.55 mm thick , fixed to the floor and ceiling at the spacing of 610mm centre to centre with dash fastener or metal screws with nylon plugs and the studs 48mm wide having one flanges of 48m and other flanges of 50mm and 0.55 mm thick fixed vertically within flanges of floor and ceiling channelk and placed at a spacing of 610mm centre to centre by 6mm dia bolts and nuts including fixing of studs along 98mm overall thiuckness parttion with 12mm thick double skin calcium silicate board with calcereous and siliceous material reinforced with collulose fibre manufactured through autoclaving process including all cost, conveyance, royalties and cost of all labours,labour cess, T&P etc complete as per specification & direction of the Engineer-in-charge.
Ground floor
First Floor
FIXED GLASS PARTITION Providing and fixing of 12mm thick less toughened Glass partition with dorma premium (911298) PT 90 Side connector and PT 80GLASS TO GLASS CONNECTOR WITH SILICONE 12MM Clear toughened glass with cutout and hole, including perimeter sealing of glass to glass joints with silicon sealant, etc asper drawing and specification including the cost of all material, T & P etc all complete as per the direction of Engineer-in-charge.
Ground floor
RCC M-25 using 12 mm. to 20 mm. (½” to ¾”) size (20 mm. not to exceed 25%) hard crusher broken granite stone aggregate of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with all cost, conveyance, royalties, taxes of all materials with all labour,labour cess and T & P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position and as per the direction of the Engineer-in-charge.
Lintel
Ground floor
Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with all cost, conveyance, royalties, with cost of all labour,labour cess, T&P and scaffolding required for the work etc. complete in all respect as per direction of the Engineer-in-charge .
Ground floor
Providing and laying Corridor Heavy duty Vitrified floor tiles 16mm thickness, siz-600x600 mm 1st quality of VARMORA, JOHNSON, KAJARIA or equivalent approved make, colours & shades laid on 20 mm thick cement mortar 1:4 (1cement: 4coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction of EIC at all floors and all heights including cost of all materials, labour, labour cess, T&P etc. required for the work all complete as per direction of the Engineer-in-charge
Ground floor
Providing and laying matt finish vitrified Germ-Free floor tiles 600x600 mm (thickness to be specified by the manufacturer) using approved quality tile of repute make such as VARMORA, JOHNSON, KAJARIA or equivalent colours & shades laid on 20mm thick cement mortar 1:4 (1cement : 4coarse send) including pointing the joints with white cement and matching pigments, etc. complete as per direction of EIC at all floors and all heights. including cost of all materials, labour, labour cess, T&P etc. required for the work all complete as per direction of the Engineer-in-charge
Ground floor
Providing & fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer ) minimum thickness 5mm using approved quality tile of repute make VARMORA, JOHNSON, KAJARIA or equivelent in all colours, shades except burgundy,bottle green, black of size 300x600 in skirting & dados over 12mm thick bed of cement mortar 1:3 (1cement: 3coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete as per direction of EIC. in all floors and all heights etc. complete including cost of all materials, labour , labour cess, T&P etc. required for the work all complete as per the direction of the Engineer-in-charge
Ground floor
Providing and fixing Dressed seasoned sal wood work in frames at any locations including doors, windows, cupboard, clerestory and other frames fixing in position including cost of hinges, M.S flat (30mm x 6mm) hold fasts lugs or dash fasteners of required dia and length as per drawing/ specifications at all floors and all heights including cost of all materials, labour, labour cess, T&P etc required for the work all complete as per the direction of the Engineer- in- Charge.
Ground floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with I mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete as per direction of Engineer in charge.
Ground floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
METAL FIRE DOOR Providing and fixing ISI Marked un-insulated fire rated door confirming to IS 3614: 2021, & tested to IS17518, and shall carry a shall be for 120minutes integrity only. Material shall be galvanised steel conforming to IS 277, made out of minimum 1.2 (18 SWG) for both frame and shutter, G.l. sheet (zinc coating 120 gsm/sqm). Frame shall be 125 x 55 grooved profile with built in rebate for fire rated smoke seal. Frame shall be mitered and field assembled. EPDM smoke seal to be provided along with frame as standard. Door shutter shall be double skin of 46mm thick with required fire rating and with vision panel. The infill material shall be resin bonded honeycomb core. All doorset shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks and door closers. The door stiles should be interlocked, for pairs of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite, minimum 5mm clear fire rated glass of size 150 x 750mm (max 0.12sq.mt) on both shutters, fixing with clipon arrangement. All frame and door shutter shall be finished polyster powder coated to minimum 50microns, of approved colour as per the direction of the engineer incharge Cost of double leaf doorset shall include following hardware and acressories as a complete assembly. SS ball bearing hinges of 55304 grade of size 100x75x3mm, 1no Fire rated mortise dead lock, 55mm BS, 20mm sq. forend, including escutheion, sss as per EN 12209 with both side key cylinder on active leaf and 2nos flush bolt on the inactive leaf in case of double leaf door along with dust proof socket at bottom, 1pairs Pull handle D type, 22dia, CTC 300mm, back toback per leaf, with spindle, SS 304, SS finish. 1no of Door closer with spring size of EN 2-4, as per EN1154 and CE marked per leaf. Suitable anchor fastners for fixing on different type of wall construction as per manufacturer recommendation. Once frames is installed it shall be filled with fire rated PUF. Manufacturer test certificates shall covers complete door set as a un-latched assembly with a valid test certificate not exceeding 5 years from the date of issue of report.for more info refer doors details drawings, including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per direction of Engineer-in-Charge.
Ground floor
GLASS DOOR Providing and fixing of 12mm thick clear toughened Glass frameless door with dorma premium fittings Dorma premium (9111198) unilite package BTS 75,UL PT 10 with cover,UL US 10Luck with cover and PT 24,Dorma premium(9137121) H Type handle 450mm, 12mm clear toughened glass with cutout and hole, including the cost of all materials hardware fittings ,cost of all labour,conveyance,loading,unloading,T&P,etc complete as per the direction of engineer-in-charge.
Ground floor
UPVC OPENABLE DOOR Supplying, fitting and fixing of Openable UPVC doors with door frame of approved make with make with 6mm thick glass of approved quality complete with frame. shutters and all Fitting and fixtures etc.
Ground floor
Toilet Cubicles Providing & fixing Greenlam Sturdo Essentia Collection- Serene Restroom Cubicle (of following standard dimension which includes 600mm door size width) self-supporting 12mm thick compact laminates made out of, urea free, thermosetting phenolic resins treated Kraft papers as core material and Amino plastic resin treated decor papers on the finish surface, conforming to latest and applicable IS: 2046-1995, EN 438:2016 and NEMA LD3-2005 quality standards with Antivirus, Antibacterial and Antifungal properties (conforming to ISO 21702:2019, JIS Z2801:2010 and ASTM G21-2015 standards respectively) to fulfil the applicable requirements of indoor air quality certifications for Greenguard-Gold standards.This also includes providing and fixing in position necessary hardware made out of Nylon Polyamide grade 6 & Aluminium alloy grade 6063-T6 powder coated finish in black and other available color hardwares as per manufacturer’s specifications & Architects instructions like (1) Self closing hinges in Nylon Polyamide grade 6 in gloss finish in available colors (2) Soft closing thumb turn lock made in nylon polyamide grade 6 in gloss finish in available colors (3) Single Coat hook in nylon polyamide grade 6 in gloss finish,available in similar available colors (4) U & F- profiles in Aluminium alloy grade 6063-T6 with powder coating in available colors (5) Nylon polyamide grade 6 Adjustable Leg (6) Top rail along with Nylon Polyamide grade 6 with end cap is a Round D shaped extrusion made of Aluminium alloy grade 6063-T6 with Powder Coating in available colors, (7) Rubber, (8) Screws & wall Plugs ( SS- 316 ). The top fitting should consist of Matt finish aluminium alloy grade 6063-T6 in avilable colors , which will get fixed on pilasters with SS Screws, All screws will of 316 Grade in stainless steel . All pilasters are supported by grade- 6 Nylon Polyamide Thermoplastic palm design pedestal footing with non corrosive steel inserts. The base anchored to the floor with grade 316 satin finish stainless steel screws with push fit capping at a clearance height of 150mm. Toilet Cubicle with standard dimension of 1995mm Height x 1000mm Width x 1500mm Depth, which includes 600mm door size width).
Ground floor
Roller Blinds Supplying & Fixing of Roller Blinds by fixing powder coated top channel, bottom channel with bottom end cap, control unit and good quality of 0.60mm thick fabric of approved design and quality etc, complete.
Ground floor
Frosted Film glass 5mm thick Supply and pesting of frosted film on the glass . Rate including all cost of material ,conveyance, Loading - unloading labour etc. including all cost, conveyances of all materials and cost of all labour with T&P etc, complete as per specification & direction of Engineer-in-charge.
Ground floor
Supplying of M.S. Grills/shutter of approved quality and design to windows and openings and staircase railing and parapet railings etc including making holes in walls and RCC structures or wood work etc in proper position making good the damages of walls or RCC or other structures complete including bending or cutting sizes or grooves in chowkhats with all cost and conveyance of all materials labour , labour cess with T&P required for the work and royalities etc.complete (including screws) in all respect in all floors as per the direction of Engineer-in-Charge .
Ground floor
Supplying, Providing, Fabricating, Assembling, hoisting, erecting and placing in position MS Built-up section/ Tubular Structure (MS) confirming to IS 2062 Grade Yst 250-350, Tubular Structure:- made from steel hollow sections, ISI marked from SAIL/ RINL/ TATA/ JINDAL, confirming to IS 1161/4923, Grade Yst 310, thickness upto 10mm) in the profile shape as per drawings with special plate connector, pinion joints, Plates, hollow sections, etc and applying a coat of epoxy primer, and including Preparation of detailed fabrication and erection drawings of Structural steel work from design drawings issued by Engineer- in- charge and incorporation of Engineer-in-Charge’s comments on same, transportation from fabrication yard, cutting, threading, machining, leads and lifts upto all heights, tools and plants and necessary scaffolding etc. required for all operations involved to make structure of Metal sheet roofing . The tubular structure system with plate connectors, pinion joints, etc must be sustained up to 250 km/hour wind pressure. The structure has to be provided as per conceptual drawings of metal shade.The work is to be executed as per technical specification and direction of Engineer-in-Charge. Note : The executor/Fabricator should provide shop drawings along with design calculation before execution of the structure and after completion of the work should give structural stability cerificate of the structure.
Ground floor
METAL SHEET ROOFING Zinc Allum Specification - Providing and fixing 0.5mm thick Zinc Allum sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 6.5 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 metre or as desired by Engineering-charge. The sheet shall be fixed using self-drilling / self-tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. etc. complete as per specification & direction of the Engineer-in-charge.
Ground floor
Priming one coat with water Bound Cement primer of approved make and shade including sand papering, cost of scaffolding, staging charges with cost, conveyance, taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge.
Ground floor
Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including sand papering, cost of scaffolding, staging charges with cost, conveyance, taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge.
Ground floor
Wall painting two coats with plastic emulsion paint of approved make and shade on new work including sand papering, cost of scaffolding, staging charges with cost, conveyance, taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge.
Ground floor
Providing and fixing false ceiling at all height with integral densified ICD bioguard calcium silicate reinforced with fiber and natural filler with bioguard coating false ceiling size 595x595 mm, of approved texture design and pattern having acoustical NRC 0.50 as per IAS8225.1987, Light Reflection 85% minimum non-combustible as per BS:476 (part 4), fire performance as per BS: 476 (part 6&7), humidity resistant of 100% thermal conductivity /0.043W/MK as per ASTMS 18:1991 in true horizontal lever suspended on inter locking metal T grade of hot dipped galvanized iron section 0.33mm thick galvanized @120gm per sq.m. including both side comprising of main tee runner size 24x38mm of the 3.00mtr, crosstee of size 24x32x1.200 and other crosstee 0.600mtr, making structure for the ceiling part. including all cost, conveyances of all materials and cost of all labour, labour cess with T&P etc, complete as per specification & direction of the Engineer-in-charge.
All Floors
Providing and fixing Aluminium anti micro bacterial Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/ sqm (both side inclusive), fixing with clip in tiles into spring T with : 12.54.1 Aluminium anti micro bacterial Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending including all cost, conveyances of all materials and cost of all labour with T&P etc, complete as per specification & direction of Engineer-in-charge.
All Floors
Dismantling brick or stone masonry in lime or cement mortar above 3m height including stacking the useful materials for reuse and removing the debris within 50m lead etc complete as per specification & direction of Engineer-in-charge.
First Floor
Second Floor
Third Floor
Fourth Floor
Removing old lime or cement plaster from walls including raking out joints 12mm deep and removing the debris within 50m lead. etc complete as per specification & direction of Engineer-in-charge.
First Floor
Second Floor
Third Floor
Fourth Floor
Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead etc complete as per specification & direction of Engineer-in-charge.
Ground floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Dismantling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debris within 50m lead etc complete as per specification & direction of Engineer-in-charge.
Eye(C&E)
PH WORKS Supplying all materials , labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipes conforming to IS: 15778 and G.I pipe fittings of the following nominal bore with clamps including making good the wall,ceiling and floor ,testing all complete as per P.H. specification and direction of Engineer-in-charge
25mm dia PVC ASTM pipe (sch-80)
32mm dia PVC ASTM pipe (sch-80)
Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.
15mm dia CP angle stop cock (Con-CHR-053KN Jaquar make)
15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make)
Elbow Tap
25mm dia brass full way valve (Shakti make)
32mm dia brass full way valve (Shakti make)
40mm dia brass full way valve (Shakti make)
15mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make)
125mm CP grating
15mm size C.P. flange
Coat Hook
supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge.
Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge
Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge.
Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.
110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B)
110mm U-PVC ‘P’ Trap(Ori Plast/Finolex/Supreme Make)
110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make)
110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make)
110mm U-PVC HR Bend(Ori Plast/Finolex/Supreme Make)
110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make)
110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Plain shoe bend(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make)
Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge
10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make )
Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge
European water closet with 'p' trap plain(Hindware/Parryware/Neycer make)
Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge
Counter basin(560x450)Hindware-No.10095
Supplying all materials, labour, T&P for fitting & fixing plain edge kitchen/wall sink of all standard sizes with a pair of bracket, C.P. waste, trap & P.V.C. waste pipe & painting brackets including supply of cement concrete & mortar etc. all complete. 24” x 18” x 10” sink
Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge
25mmx600mm long CP towel rail
Towel ring
Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge.
600mmx125mm plate glass shelf with CP/NP guard rails.
Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge.
600mmx450mm size B.E mirror (swivelled type)
Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge
Inside size 76cmx76cmx46cm with 18” dia RCC MH cover
Supplying all materials labour T&P filling sand in lavatories well watered and rammed including lead of materials to work site.
Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size 40cmx40cm special printed series to be pre-approved by the Engineer-in-charge )
Ceramic tile 60cmx60cm
Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size 25cmx33cm special plain / printed series to be pre-approved by the Engineer-in-charge )
Glazed tile 60cmx30cm
Granite
Supplying & fitting fixing of unplasticised Poly vinly chloride (UPVC ) (FENESTA/ NCL/ VEKA LTD) Casement Door series dully manufactured using UPVC reinforced profile of 60mmx55mmx2.5mm for outer frame
Supplying all materials, labour, T&P for distampering two coats to wall with distamper of approved shade on new work to give an even shade including cost of distamper.
Supplying all materials, labour, T&P and providing fitting and fixing Water cum storage etc all complete as per approved drawing , specification and direction of the Engineer in charge
Purifier water storage cum Hot,Cold,Normal
Ext. S/D Portion
Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge
100mm dia P.V.C. pipe
150mm dia P.V.C. pipe
Supplying all materials.labour.T&P and providing brick work in foundation and plinth with KB bricks having curshing strength not less than 75 kg/sqcm with dimensional tolerance+ 8% in cement mortar ( 1:3 ) including watering,curing,cost of all materials,conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer in charge.
Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
Medical Grade copper pipe with required copper fittings, All pipes shall be drawn half hard temp., solid drawn, seamless, phosphorous deoxidised, non-arsenic and degreased copper pipe conforming to EN BS: 13348:2008/ASTM B819 standard ,EN 1057:1996 (originally BS 2871-1971 Part 1 (Table X) and chemical composition as per BS-6017 of 1981 table 2, The supplies of copper pipe would be accompanied with manufacturers test certificate for the physical properties of copper pipes and their Chemical composition. The supply of pipes be further substantiated with inspection certificate from the third party like Lloyds Register. etc. complete as required.
Copper Pipe 12 MM X 0.7 OD
Copper Pipe 15 MM X 0.9 OD
Copper Pipe 22 MM X 0.9 OD
Copper Pipe 28 MM X 0.9 OD
Copper Pipe 42 MM X 1.2 OD
Copper Pipe 54 MM X 1.2 OD
Copper Pipe76 MM X 1.2 OD
Isolation Ball Valve 12 MM (MAKE:-MATRIX)
Isolation Ball Valve 28 MM (MAKE:-MATRIX)
Isolation Ball Valve 42 MM (MAKE:-MATRIX)
Ms Support Structure with fabrication For Medical Gas Pipelines (Oxygen , Vaccum , Surgical Air , Medical Air , CO2 , Nitrus Oxide) from central medical gas plant to main building & riser in overhead system which will be connect from gas plant to main building . The details are given below. 1. Minimum height of overhead structure 17/20 Ft 2. Weidgth 1/1.5 Mtrs 3. Structural Strength as per the civil drawing , as per the distance according to civil drawing . 4.Pipeline Support system which will be covered by perforated GI tray . (Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as per direction of EIC)
EI WORKS HVAC WORK Inverter based VRV/ VRF System Outdoor Units Supply,Installation, Testing and Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling only, having all hermetically sealed inverter type Scroll Compressor(s) microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. The unit shall deliver the rated capacity at AHRI Conditions and work even at 49°C ambient temperature without tripping. The unit shall be suitable to work on 380-415 V, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. MS/GI powder coated stand with vibration isolation pads.The ODU shall have low noise condenser fans with external static pressure of the outdoor unit shall be more then 75 Pa to avoid hot air recirculation, auto address setting, automatic refrigerant charging,blue fin treated condensor coil for corrosion resistant, auto check function for connection error and complete with indoor and outdoor units with individual controller and with fittings etc. .The Unit should have free phase technology so that unit can work in case of phase reversal also without tripping of units.ISEER should be greater than equal to 7.4 for cooling capacity less than 40kWr, ISEER should be greater than equal to 7.5 for cooling capacity more than equal to 40kWr and less than 70kWr and ISEER should be greater than equal to 7.6 for cooling capacity more than equal to 70kWr.The deration chart of outdoor from factory head should be submitted before procurement.Make: Mitshubishi/ TRANE/O-GENERAL/Daikin
SITC of ODU Connecting Kit with other accessories as per the direction of Engineer-in-charge.Make: Mitshubishi/ TRANE/O-GENERAL/Daikin
SITC of AHU connecting kit with other accessories as per the direction of Engineer-in-charge.Make: Mitshubishi/ TRANE/O-GENERAL/Daikin
Supply, Installation,Testing and Commissioning of following minimum capacity 4-way VRV Cassette Type Indoor ceiling mounted unit equipped with cord less remote , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump, cassette grill, insulation, necessary supports, vibration isolation,fire resistant metal box protection for indoor unit PCB etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. The cost is inclusive of Refnet joints. Make: Mitshubishi/ TRANE/O-GENERAL/Diakin
11TR 3200 CFM 6RD, ESP-65MM, FM AHU
18TR 5000 CFM 6RD, ESP-65MM, FM AHU
24TR 6500 CFM 6RD, ESP-65MM,FM AHU
Refrigerant Piping Supply & Installation of interconnecting following sizes of refrigerant copper pipe work of following outer diameter, insulated with 25mm thick Class- O fire rated closed cell electrometric Nitrile rubber tubular insulation between each set of indoor & outdoor units . The pipe dia upto 25 shall be soft seamless & above 25mm dia shall be hard seamless . All piping inside the room shall be properly fixed/supported with suitable size of clamp/ M.S. hanger and all external piping shall run in GI. cable tray etc. as reqd. Make of insulation-K Flex/Armacell/Vidoflex/Eurobatex/Isoline Make of pipe-Rajco/Mandev/Maxflow
41.3 mm with 1.43 mm thick
34.9 mm with 1.21 mm thick
28.6 mm with 1.00 mm thick
22.2 mm with 0.8 mm thick
19.1 mm with 0.8 mm thick
12.7 mm with 0.8 mm thick
15.9 mm with 1.00 mm thick
9.5 mm with 0.8 mm thick
6.4 mm with 0.8 mm thick
Supply & Installation of interconnecting following sizes of refrigerant copper pipe work of following outer diameter, insulated with 25mm thick Class- O fire rated closed cell electrometric Nitrile rubber tubular insulation between each set of indoor & outdoor units . All external piping(which are exposed to external environment such as terrace etc.) shall be provided with factory laminated GC Cloth & then shall run in perporated hot dip galvanized GI. cable tray with cover etc. as reqd. Make of insulation-K Flex/Armacell/Vidoflex/Eurobatex/Isoline Make of pipe-Rajco/Mandev/Maxflow
41.3 mm with 1.43 mm thick
34.9 mm with 1.21 mm thick
19.1 mm with 0.8 mm thick
15.9 mm with 1.00 mm thick
Drain Piping Providing & fixing of PVC Pipe complete with fittings, supports as per specifications and duly insulated with 9 mm thickness Class O of closed cell nitrile rubber/XLPE as per direction of Engineer-in-charge & specifications enclosed as reqd.
50 mm dia
40 MM dia
32 mm dia
Control & Transmission Wiring
Providing & fixing control cum transmission wiring of 2 core x 1.0 sqmm shielded copper cable in suitable conduits between indoor and out door unit. Make-Polycab/KEI/Finolex/RR Kabel/Gloster/Havells
Supply of Gas Charging for the entire circuit(R410A)
Air Distribution Supply, Manufacturing, fixing,testing and commisioning of GI ducting(180 GSM) complete with supports,dampers etc.as per specifications. MakeTATA/SAIL/JINDAL
22 Gauge
24 Gauge
Insulation work
Supply,installation,testing and commissioning of duct thermal insulation of Following Capacities , Make of insulation-K Flex/Armacell/Vidoflex/Eurobatex/Isoline . - with 25mm thick Class- O fire rated Nitrile Rubber with factory laminated GC CLOTH to provide the sufficient mechanical protection. The fibre glasscloth shall be factory laminated. The adhesive shall be SR 98 or equivalent sourced from OEM of nitrile rubber insulation.
Supply ,& Fixing of antimicrobial Accoustic Insulation 15 mm thick of Class- O fire rated open cell nitrile rubber(180 kg/m3). Make of insulation-K Flex/Armacell/Vidoflex/Eurobatex/Isoline
Supply ,& Fixing of Flexible weather proof PVC canvas connection
Supply, erection, testing & commissioning of Aluminium powder coated grills/diffuser with VCD having flange all around.Make-Glenstorm/Airflow/Systemaire
Supply, erection, testing & commissioning of Aluminium powder coated grills/diffuser without VCD having flange all around.Make-Glenstorm/Airflow/Systemaire
Supplying,fixing of hot dip galvanized GI unperforated cable trays with cover having horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 600mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
Supplying,fixing of hot dip galvanized GI unperforated cable trays with cover having horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 450mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
ELECTRICAL WORK Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole and earth metal enclosed plug top along with 32 amps. C-series, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge Make-Legrand/Schneider/Siemens/ABB ISI marked as approved,All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.(for equipement only at required area)
BDBS & MCBS Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 /ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.
4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years
Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, MCB . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 years..
Supplying and fixing 63Amps 4P 415 volts MCB, C Series, 10 kA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.Warranty on MCB is 1 year.
(Earthing) INSTALLATION
Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
CABLING AND END TERMINATION MAIN AREA Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.
3.5core x 240 sq mm
3.5core x 150 sq mm
4core x 16 sq mm
Supply & Laying of 5 corex 10Sqmm Copper Armoured XLPE Cable.Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster
LAYING OF CABLE
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 400 SQ. MM From 120 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
3.5 core x240 sq mm
3.5 core x150 sq mm
4 core x16sq mm
PANELS MAIN HVAC PANEL S/I/T&Commissioning of LT outdoor floor mounted cubical type electrical main panel (forHVAC circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. )as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 SPD 40kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 60X10MM Separate Aluminium Earth bus bar should be installed.All the feeders shall have ON/OFF/TRIP indication In commer- 01 numberof 630A 4P MCCB(40% I n rated-100% I n rated) with ROM 36kA with adjustable Micro processor Release with Ics=100% Icu. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula)with shunt trip.with axulary for BMSWith On/Off/Trip Indication. Busbar- 04 numbers of 700Amps 50kA aluminium busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going- 6 numbers of 200A 4P Icu=100%Ics, LSIG MCCB with micro processor based release with 25KA along with 250A 4P contactor with axularies , ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula))With On/Off/Trip Indication (ii) 01 set of 3 ph digital type Voltmeter (Make-Siemens/Schneider /ABB/ Legrand ). (iii)01 set of 3 ph digital type AmmeterA(Make-Siemens/Schneider/ABB/Legrand) with CTs 800/5A 3 nos class 1 type(Make-KAPPA /AE)
HVAC ODU PANEL,COM. S/I/T&Commissioning of LT outdoor floor mounted cubical type electrical main panel (forHVAC circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. )as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 SPD 40kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 40X10MM Separate Aluminium Earth bus bar should be installed.All the feeders shall have ON/OFF/TRIP indication In commer- 01 number of 200A 4P MCCB,25 Ka with under voltage,over voltage ,current,earth fault protection ( Make-LEGRAND-DPX3 DB/ Siemens-3VA Model/ Schneider- CVS/ ABB Formula) Busbar- 04 numbers of 300Amps Aluminium busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going- (i) 63A 4P RCBO,300MA 4 NOS FOR OUT DOOR UNIT ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB200) Out going- (i)32A 4P RCBO,300mA 4NOS FOR OUT DOOR UNIT ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB200) Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication
CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER
Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
Supply and laying of 630 sqmm single core Al armoured cable 3 run per phase.Make-Polycab/KEI/Finolex/Havells/RR Kabel/Gloster
Supply and fixing of outdoor type 2000A 50 ka LT ACB EDO TYPE ACB Micro Processer Based with Breaking capacity - Icu= Ics= Icw= 50kA for 1 sec having LSING Protection with Display-Current Metering with Last Trip Record Data. with metering unit and 2200 A Al busbar for connecting 5 nos 400 sqmm 3.5 core Al armoured cable with all accessories as per the direction of Engineer-in-charge.Make-Schneider(NW) / ABB (E max 2 )/ Siemens (3WT)/ Legrand(DMX3)
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
techsummary_584844.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.83 MB
BOQ_584844.xls
BOQ • 0.64 MB
DTCN_DHH_Boudh.pdf
Tender Documents • 5.49 MB
Download all tender documents and submit your bid