Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹1.2 Cr+₹6.9 L (5.90%)Rejected-Finance | ₹1.2 Cr+₹6.9 L (5.90%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹1.2 Cr+₹7.1 L (6.05%)Rejected-Finance | ₹1.2 Cr+₹7.1 L (6.05%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹1.3 Cr+₹12.6 L (10.7%)Rejected-Finance 95 A GOVIND NAGAR RACE COURSE OPP GURUDWARA DEHRADUN UK PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹1.3 Cr+₹12.6 L (10.7%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹1.3 Cr+₹13.5 L (11.5%)Rejected-Finance | ₹1.3 Cr+₹13.5 L (11.5%) | L5 | Rejected-Finance Not being L1 |
Tender Value
₹1.7 Cr
EMD Value
₹2.4 L
Closing Date
7 Aug 2020, 6:00 pmClosed
CE(AF) BANGALORE
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
PROVISION OF HOT WATER SUPPLY AT TRAINEE BILLETS AT AF STN BELGAVI
2020_MES_352887_1
801465/E8
Open Tender
Civil Works
Item Rate
365 days
GE (AF) SAMBRA
AS PER NIT
8 documents required · 8 mandatory
₹1,000
GE (AF) SAMBRA
₹2.4 L
Yes
14 Sept 2020
15 Jun 2020
8 Aug 2020
15 Jun 2020
7 Aug 2020
21 Jul 2020
15 Jun 2020 - 10 Jul 2020
Amount
SCHEDULE 'A"PART-I (Hot Water Supply)Supply, installation connecting , testing & commissioning of solar water heating system with heat exchanger type of capacity 500 ltrs per day with electical backup by 3KW heating elements each 3 Phase of two numbers and thermostates, collectors of ISI marked with required numbers of flat plate collectors and laser welded tube with stainless steel hot water storage tank 500 ltr including supply and fixing of SS heat exchanger made of SS 304 pipe as per OEM inside the hot water storage tank, providing angle iron structure of reqiured size for collectors and angle iron staging for the hot water tank with required size made out of 25mmx4mm angle iron/flats duly welded, PCC work 1:2:4 Type B1 with 20 mm graded aggregate for foundation/fixing of solar water heating system including electrical connection from solar water heater to sheet metal plug top with 3 core PVC insulated sheathed multistranded copper cable as required at site complete all as specified and as directed .
Supply and fixing three layered rotational moulded polyethylene water storage tank of 500 ltrs (cylinderical vertical with closed top ) ISI Marked hoisted and fixed in position all as specified and directed.
S&F MS angle or tee sections, fixed independently, without connection plate, etc including necessary drilled holes, welded together, anchored to the roof with suitable anchor bolts of minimum 10 mm size conforming to Fe 410 Gde E - 165.for fabrication of staging of water tank and complete structure duly painted with two coats of synthetic enamel paint over and coat of red oxide primer complete all as specified and as directed.
M & L for Plain Cement concrete 1:2:4 Type B-1 using 20mm graded stone aggregate as in filling and mass contrete for grouting of angle iron structure and support of pipe including use and waste of form work and all as directed.
S&F steel water tubing 50 mm bore 'medium grade' galvanised with all GI fittings (such as bends, elbows, tees, conectors, short pieces, back nuts, unions, caps & plugs etc) fixed complete to wall and ceiling or laid in floor including cutting, threading and testing complete all as specified and directed
S&F steel water tubing 40 mm bore 'medium grade' galvanised with all GI fittings (such as bends, elbows, tees, conectors, short pieces, back nuts, unions, caps & plugs etc) fixed complete to wall and ceiling or laid in floor including cutting, threading and testing complete all as specified and directed
S&F steel water tubing 25 mm bore 'medium grade' galvanised with all GI fittings (such as bends, elbows, tees, conectors, short pieces, back nuts, unions, caps & plugs etc) fixed complete to wall and ceiling or laid in floor including cutting, threading and testing complete for hot/cold water pipe line all as specified and directed
S&F steel water tubing 15 mm bore 'medium grade' galvanised with all GI fittings (such as bends, elbows, tees, conectors, short pieces, back nuts, unions, caps & plugs etc) fixed complete to wall and ceiling or laid in floor including cutting, threading and testing complete all as specified and directed
M&L for Lagging to pipes used in internal water supply or plumbing all round with, 50mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 of pipe of internal dia 25 mm complete all as specified and directed.
M&L for Lagging to pipes used in internal water supply or plumbing all round with, 25mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 of pipe of internal dia 15 mm. complete all as specified and directed.
Supply and fixing gun-metal globe valve or gate valves 25mm with iron wheel head, screwed both ends for iron pipe ISI marked complete all as specified and directed.
Supply and fixing 16 Amps rating industrial wall mounted plug and socket 3P+N+E with MCB TP 16 Amps including 3.15 mm thick MS enclosure weather proof with front openable hinged door duly powder coated suitable for IP55 degree of protection complete all as specified and directed.
Supply and fixing geysers of 25 ltr capacity BEE 5 Star made of rust proof body to withstand pressure capacity (upto 8 bars) puf insulation and copper inner container coated with unique polymer protective coating technology to resist corrosion from hard water, including surface and vertical type thermostat and cutout and out smart three level safety against high temperature and high pressure provided with high tech adjustable thermostat and international standards multifunction valves complete including necessary anchor bolts of required size and hot & cold water connection pipes etc all as specified and as directed.
S&F stop cock, cast copper alloy screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or unions fixed of 15 mm bore dia of pipe complete all as specified and directed..
M&L for sub main wiring complete with two runs of 4 sqmm single core FRLS PVC insulated unsheathed cable, 1100 volt grade, multistranded copper conductor cable including one run of 4 sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and accessories/ PVC casing capping of suitable size and accessories on surface of wall / roof etc all as specified and as directed by Engineer -in - charge.Note: Three runs of 4 sqmm cable and one run of PVC conduit and conduit accessories will be measured and paid as one unit
S&F sheet metal enclousure for MCB DB single pole and neutral 4 way with 100 Amps rated bus bar 240 volts double door type complete all as specified and directed.
S&F MCB 4 pole 32 Amps 415 volts complete all as specified and directed.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one SPN MCB 20 Amps for water geyser.complete all as specified and directed.
S&F Bib taps of size 15 mm cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F 40 mm dia gun metal globe or Gate valve(ISI marked),with iron wheel head screwed both ends for iron pipe complete for size pipe complete all as specified and directed.
Cutting of existing GI pipes 50/40 mm dia medium grade rising pipe for tapping of proposed inlet pipe of solar water heater including necessary fittings and accessories of connection complete all as specified and as directed by Engr-in-charge
SCHEDULE 'A"PART-II (External Electric Supply ) Excavation in trenches 1.50m wide and not exceeding 1.5m deep for laying cables and getting out in hard / dense soil for laying cable/erecting poles all as specified and as directed.
All as per item No.22 here-in-before but exceeding 1.5m but not exceeding 3.0m in depth all as directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in hard / dense soil.
Supply and spread riddled earth obtained from item No 22 in trenches as in cable cushioning all as directed. Note: For the purpose of measurement only punned thickness of 18cm will be considered for payment..
Supply and laying bricks, common burnt clay sub class 'B' designation 75 as in cable protection all as specified and as directed
Removing excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as directed.
Supply and errect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.00metres long) including painting all external exposed steel surfaces with two coats of aluminium paint over a coat of zinc chrome primer and all internal surfaces & external surfaces in contact with concrete with two coats of black bituminous paint including writing MES No with synthetic enamel paint and red reflector strips on HT pole(First Grade/quality) complete all as specified and as directed. Note : Necessary excavation and earth work, PCC foundation, coping etc., shall be measured and paid separately under relevant item
M&L for Plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete.
M&L for Plain Cement Concrete 1:3:6 type C1 using 20 mm graded stone aggregate as in coping including weathering rounded/ chamfered angles and throating as directed including necessary form work. (Exposed surfaces of concrete shall be finished even and smooth without using extra cement).
Supply & installing HT 11 KV outdoor type gang operated break switch triple pole mechanically operated, vertically or horizontally mounted on insulator and steel frame with operating mechanism worked from ground level for current upto 200 amps suitable for 11000 volts grade including 9 Nos insulators and including GI pipe medium grade 25mm of suitable length and necessary arrangements for the operating mechanism complete all as specified and as directed.
Supply and fixing lightning arrestor expulsion type complete with all fittings and necessary fixing arrangements, transmission class discharge capacity 65 kilo amps for 11000 volts capacity.
Supply and fixing Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of aluminium paint over a coat of red oxide primer all specified and as directed.
M&Lfor Anticlimbing device,spikes type fabricated out of M.S. Bars (round,square and flat) including nuts,bolts,washers and welding in two halves made to shape to suit the cross section of the pole complete all as directed
S&F Disc type insulator, porcelain, vitreous 145mm high and 225mm dia ball and socket type, white , brown or green, two in series assembly for tension with tension clamps for conductors,working pressure 11000 volts complete all as specified and as directed.
Supply and fixing single pole out door drop out fuse assembly with expulsion fuse 12 Amps for 11 KV complete all as specified and directed
M&L for Aluminium conductor, steel reinforced (ACSR) fixed on poles including binding wire jumpers with clamps etc complete all as specified and as directed.
M&L vice type connectors consisting of two brass plates and two steel bolts and nuts for 2 conductors for equal or unequal sizes for non tension connections including treatment of connector and ACSR conductor with conducting jelly.
S&F cable jointing kit for 11 KV grade cable for Outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 sq mm.
M&Lfor Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25 x20 cm size all as directed.
Supply,installing & testing of transformer step down, outdoor type complete with copper wounded, standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tap changer +7.5% in steps of 2.5% each on HT side to vary secondary voltage within limit all as per IS:1180 (Part-I) 2014 with energy efficieny level 2, of capacity 200 KVA, ONAM, vector group , Dyn-II including first filling of transformer oil and all standard accessories and fittings such as LV cable entry box, lifting lugs, unidirectional rollers, oil drain valve, thermometer air release plug, breather, vent, arching horn set set etc complete all as specified and as directed by Engg-in-charge
M&L for brick masonary transformer platform of size 1.5 mtr x 1.5 mtr with height 1.2 mtr above GL Cement concrete in foundation of PCC (type D2) , 1:4:8 (using 40 mm graded stone aggregate),PCC block masonary 1:3:6 in CM (1:4) moorum filling and consolidating inside the brick work , sub base concrete with PCC 1:3:6 and 100 mm thick top PCC 1:2:4 type B2 & 15 mm plaster on side walls in 1:4 CM incl two coats of white wash complete all as specified and as directed.
S&F chain link MS galvanized fencing 30 RM length, height 2 mtr and, 3mm/4mm dia GI wire and 100x100 mm mesh, angle or Tee section (40x40x5mm) fixed independently, with connecting plates for fencing post including necessary drilled holes, bend to shape at top as directed for fencing posts of the transformer yard & mild steel round bars 10mm dia as in horizontal line wires of chain link fencing of quality Fe-290 (Gde E-165), pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar type C-1 1:3:6, complete built in cement mortar 1:6 making kerb wall of 300 mm height around the substation,Plaster on side walls1:4 CM 15mm including gate of size 2mtrX1.8mtr fabricated out of MS angle iron complete all as specified and directed complete all as specified and directed
Material and Labour for Earthing and testing complete with galvanized iron earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 M below normal ground level with top edge of earth plate at a depth not less than 1.5 M below normal ground level connected to and including GI strip 25x4 mm as earth lead by means of bolts and nuts, check nuts and washers etc made of GI & connected to high mast light/LT panel and earthing test point , earth dolly all as shown in elect plate No 3 of SSR Pt-I including all necessary earth work, excavation PCC chamber cover with handle (PCC 1:2:4) and 20mm dia GI watering pipe and 40 mm dia light grade GI for protection of earth strip ,wire mesh, funnel, charcoal dust & common salt, etc all as specified and directed.
Material and Labour for Earthing and testing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground vertically to a depth not less than 2.25 M below normal ground level with top edge of earth plate at a depth not less than 1.5 M below normal ground level connected to and including 20 x 3 mm copper strip as earth lead by means of bolts and nuts, check nuts and washers etc made of copper & connected to transformer/LT panel and earthing test point , earth dolly all as shown in elect plate No 3 of SSR Pt-I including all necessary earth work, excavation PCC chamber cover with handle (PCC 1:2:4) and 20mm dia GI watering pipe and 40 mm dia light grade GI for protection of earth strip ,wire mesh, funnel, charcoal dust & common salt, etc all as specified and directed.
Earth continuity conductor or main earthing lead beyond 7.50m fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthling etc. as required by using GI strip of size 25X4mm.
Earth continuity conductor or main earthing lead beyond 7.50m fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthling etc. as required by using copper strip of size 20X3mm.
Supplying, laying and testing under ground HT cable, XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, electric power cables (heavyduty) with stranded aluminium conductor, 11000 Volts (Earthed), grade cross sectional area 95 sq. mm x3 Core.
Supply laying & testing LT electric cable XLPE Insulated screened PVC bedded, galvanized steel strip armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade,of size 3.5 core 300 sq mm complete all as specified and directed.
All as per item No.49 here-in-before but of size 3.5 core 240 sq mm
All as per item No.49 here-in-before but of size 3.5 core 150 sq mm
All as per item No.49 here-in-before but of size 3.5 core 95 sq mm
All as per item No.49 here-in-before but of size 3.5 core 70 sq mm
All as per item No.49 here-in-before but of size 3.5 core 35sq mm
All as per item No.49 here-in-before but of size 4.0 core 25sq mm
All as per item No.49 here-in-before but of size 4.0 core 16sq mm
Supply only rubber mat of size 2mx1mx19mm, ISI marked LV grade, 1100volts grade complete all as directed.
Supply only rubber mat of size 2mx1mx10mm, ISI marked LV grade, 1100volts grade complete all as directed.complete all as directed.
Supplying , installing, testing and commissioning of LT Feeder pillar Box AC 415 V , 50 HZ 3 Phase 4 wire of suitable size for accomodating the following accessories totally enclosed self supporting structure / cubicle , fully compartmentalized type , weather proof , protection IP 54 , suitable for outdoor use , with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm , with four legs grouted to PCC (1:2:4) type B1 , foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter , changeover switch and MCCBs , with sloping canopy at top , double hinged doors at front with suitable locking arrangement , Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated , complete all as specified and directed :-
Supplying , installing, testing and commissioning of LT Feeder pillar Box AC 415 V , 50 HZ 3 Phase 4 wire of suitable size for accomodating the following accessories totally enclosed self supporting structure / cubicle , fully compartmentalized type , weather proof , protection IP 54 , suitable for outdoor use , with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm , with four legs grouted to PCC (1:2:4) type B1 , foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter , changeover switch and MCCBs , with sloping canopy at top , double hinged doors at front with suitable locking arrangement , Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated , complete all as specified and directed :-
Material and Labour for Earthing and testing complete with galvanized iron earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 M below normal ground level with top edge of earth plate at a depth not less than 1.5 M below normal ground level connected to and including 4mm GI wire as earth lead by means of bolts and nuts, check nuts and washers etc made of GI & connected to machinery/equipmen and earthing test point , earth dolly all as shown in elect plate No 3 of SSR Pt-I including all necessary earth work, excavation PCC chamber cover with handle (PCC 1:2:4) and 20mm dia medium grade GI watering pipe and 15 mm dia light grade GI for protection of earth strip ,wire mesh, funnel, charcoal dust & common salt, etc all as specified and directed.
M&L for Cutting the existing PCC/bituminous road of any description to a size not exc. 0.5m wide x 1.0m deep for crossing of cable in pipe including refilling, ramming and making top 100mm thick surface good with plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate complete all as specified and directed.
M&L for GI pipe, 100mm bore, light grade, ISI marked, for cable protection with all fittings laid in trenches all as directed.
All as per item No.67 here-in-before but of 80mm dia.
All as per item No.67 here-in-before but of 50mm dia.
All as per item No.67 here-in-before but of 40mm dia.
S&F MCCB 4 pole 63 Amps 16 KA complete all as specified and directed.
Supply and spreading in layers graded coarse aggregate 40 mm graded for transformer yard around sub-station etc complete all as directed.
ASHIRWAD ELECTRICALS
M/S SANJAY B SHARMA
M/S Manmohan Singh Anand
M/S SETHI BROTHERS
M/s S N Atiwadkar
Vinayaka Enterprises
devan enterprises
K T ASSOCIATES
M/s. VIJAY ELECTRICALS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .