Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC | L1 | Accepted-AOC The lowest tenderer | |
| 2 | L2₹26.9 L+₹3.7 L (15.8%)Rejected-Finance | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹33.2 L+₹10.0 L (42.9%)Rejected-Finance 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L3 | Rejected-Finance Not the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
4 Oct 2024, 6:00 pmClosed
HQ CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
REPAIR MAINT TO UNDERGROUND OVER HEAD HT EXTERNAL ELECTRIFICATION SYSTEM ALONGWITH OTHER CONNECTED ITEMS AT MIL STN FAZILKA UNDER GE ABOHAR
2024_MES_672655_1
CA NO CWE SGNR T-48 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE ABOHAR
As per NIT
9 documents required · 9 mandatory
₹500
GE ABOHAR
₹60,000
Yes
7 Feb 2025
6 Sept 2024
5 Oct 2024
6 Sept 2024
4 Oct 2024
20 Sept 2024
Amount
Excavation in trenches any type of soil, n exc 1.5m wide and n exc 1.5m in depth, for foundation, etc or for shaft, well, cesspits, manholes , pier hole etc n exc 1.5 m in depth and getting out for laying of cable complete all as specified and directed by Engr-In-Charge.
Returning, filling in including, spreading , levelling , watering and well reamming in layers not exc. 25 cm complete all as specified and directed by Engr-In-Charge.
M&L for Sand filling under flooors, in trenches or in foundation for cable protection including and consolidation complete all as specified and directed by Engr-In-Charge.
M&L for removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for providing cement concrete type C:2, 1:3:6, using 40 mm stone aggregate as in foundation, roof, kerb or mud stops, rounded or chamfered on edges complete all as specified and directed by Engr-In-Charge.
M&L for boring hole across the road/plinth/hard standing by trench less technology method suitable for up to 100 mm bore pipe for 0.4 mpa working pressure for cable passing without damaging Road/plinth/floor complete all as specified and directed by Engr-In-Charge. Note : GI tubing shall be measured and paid under respective items.
S&F un-reinforced precast concrete cable cover class HVP type 1 with peak, size 300mmx180mmx40mm laid flat length of cover across the length of cable and old US PCC cover to be disposal off 100 mtr away from the site complete all as specified and directed by Engr-In-Charge.
Taking out old unserviceable under ground HT cable upto 185 sqmm from trenches/floor/ road/pipe/along poles including taking out old bricks PCC cable cover complete all as specified and directed by Engineer-in-charge. Note:- Excavation, earth work shall be measured and paid under respective items of BOQ.
Supplying, laying, jointing and testing XLPE insulated,screened,PVC beded, galvanised steel strip or wire armoured, electric power cables (heavy duty)with aluminium conductor HT cable 11000 volts grade with cross sectional area 95 Sqmm 3 core laid in trenches/ ducts/ along poles/ through pipes complete all as specified & directed by Engineer-in- charge. Note: Excavation & earth work shall be measured & paid under respective item of BOQ.
Laying only HT UG Cable of size 3 Core , 95 to 185 Sqmm, 11000 V grade PVC/XLPE insulated, PVC sheathed armoured conductor laid in trenches/Road/paths/ on poles through GI protection pipe complete including connection of cable at both ends with suitable size of glands, aluminium lugs complete joining, testing and commissioning including disconnecting and removing existing UG Cable complete all as specified and directed by Engr-In-Charge. Note: (a) HT UG Cable shall be laid against retrived Serviceable cable under relavent itemsof the schedule. (b) Earth work for the cable removing, laying measured and paid separately under relevent items of the schedule.
Laying only old HT cable cover full size of useful obtained from excavation against cable shifting/rerouting complete all as specified and directed by Engr-In-Charge.
S&F in replacement cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified.
S&F in replacement cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Engr-In-Charge.
S&F in replacement cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed by Engr-In-Charge.
S&F in replacement cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Engr-In-Charge.
S&F in replacement cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed by Engr-In-Charge.
M&L for fabrication of cross arms bracings supports,clamps and back plates,iron stainer, water gate, ladder for clear water tank etc as required structural steel section including nuts, bolts, washers, welding, bending, cold or hot, drilling holes for bolts in any shape or size and including two coats of synthetic enamel painting over a coat of red oxide primer complete all as specified and as directed by Engr in charge.
M&L for painting of old painted surfaces with synthetic enemel paint to steel tubular pole 9/11 mtr long including clamps,brackets,chanels,cross arms,bracing support and supporting pipe of cables etc including zebra painting at bottom up to 1.5 mtr above from the PCC couping and writing pole No with white paint complete etc complete all as specified and directed by Engr-In-Charge.
S & F GI tube light grade galvanised of size 100 mm with all fitting and fixed to wall and celling or laid in floors/under road etc complete all as specdied and directed by Engineer-in- Charge.
S & F GI tube light grade galvanised of size 80 mm with all fitting and fixed to wall and celling or laid in floors/under road etc complete all as specdied and directed by Engineer-in- Charge.
S & F GI tube light grade galvanised of size 50 mm with all fitting and fixed to wall and celling or laid in floors/under road etc complete all as specdied and directed by Engineer-in- Charge.
S&F in replacement of pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 150 mm height,150 mm dia for 11000 volts grade complete all as specified and directed by Engr-In-Charge.
Taking out old unserviceable an S&F shakle porcelain, vitreous, white, brown or green insulator including one galvanised mild steel straps, washers, insulator bolts, washers and nuts, 150 mm height,150 mm dia for 11000 volts working pressure grade and with galvanised steel section straps in mm 38x5 with 20mm dia of bolts complete all as specified and directed by Engr-In-Charge.
Supply and fix tinned copper drop out fuse barrel types suitable for HT 11 KV line of sizes 5 Amps to 60 Amps complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement of ACSR conductor, steel rainforced of required size or guage complete all as specified and directed by Engineer-in-charge.
Supply and fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed by Engr-In-Charge.
Supply & install in replacement 11 KV air break gang operated triple pole out door type gang operated air break switch mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level with 09 Nos insulators outdoor type triple pole suitable for vertical operation provided with locking arrangement consisting of MS channel HT post type insulator high pressure heavy tined copper alloy contact assembly suitable for 400 Amps, including air break switch suitable for 11 KV, 400 Amps mounted on 09 Insulators with drop out fuse unit, operating rod 25mm dia GI medium grade pipe complete all as specified and directed.
Material and labour non linear resistor type surge arrester (lightening arrestors) confirming to IS 3070 (Part 1) having voltage rating 12 KV, rated frequency-50 HZ, nominal discharge current capacity 65 Kilo amp (Heavy duty) complete with all fittings, suitable for 11KV, 3-Phase, earthed distribution system complete all as specified.
M&L for filling of aggregate for loose filling of size 40 mm to 80 mm graded brocken stone aggregate pices complete all as specified and directed by Engineer-in-charge.
Supplying and laying synthetic rubber insulated mats 2.5 mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed by Engineer-in-Charge.
M&L for disconnecting HT & LT side cables of follwing indoor/outdoor transformer of capacity 50 KVA to 400 KVA and earth strip from body and neutral of transformer mounted on two pole/four pole structure/staging/sub stn and taking down the transformer manually/using mechanical means and lifting loading and transportation to MES store yard/site to civil workshop for repair and opening of covers,draining out existing transformer oil,lifting of core,cleaning oil tank using chemicals,cleaning of core after removing HT/LT winding,re-assembling of new HT/LT windings with core varnishing heating and bringing back the same after repairs to the same point all as specified and directed by Engineer-in-charge. Note: (i) Rewiding of HT/LT coil any type/material, dehydration of transformer oil reassembling after repair etc.will be measured and paid seperately under relevant item of the schedule. (ii) Spare part shall be deemed to included in the quoted rate of the above items. (iii) Contractor have to install and fix the repaired transformer within 15 days from date of handed over to contractor, if contractor fails to fix and install the transformer within said time period penalty of Rs. 500 /per day will be charged from the contractor for the delay caused and will be deducted from payment. (iv) Contractor have to supply the transformer of same capacity (transformer taken for the repair) to the MES for uninterruption of electric supply. Transportation, installation and connection of the same will be arrange by the contractor. All charges are deemed to be included in the item rate quoted by contractor.
M&L for re-winding of 11 KV HT/LT coils with super enemelled best quality copper wire of existing guage with superior quality insulation material for transformer of capacity upto 400 KVA complete all as specified and directed by Engineer-in-charge. Note : The rewinding of transformer shall be done only after the inspection and certifiaction by representative of GE declaring the old winding of transformer as unserviceable in writing.
Supply and fixing in replacement of ceramic LV bushing as per existing size/model complete with bushing stud (brass metal) for transformer of capacity 50 KVA to 200 KVA complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of ceramic LV bushing as per existing size/model complete with bushing stud (brass metal) for transformer of capacity 315 KVA to 400 KVA complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of ceramic HV bushing as per existing size/model complete with bushing stud (brass metal) for transformer of capacity 50 KVA to 200 KVA complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of ceramic HV bushing as per existing size/model complete with bushing stud (brass metal) for transformer of capacity 315 KVA to 400 KVA complete all as specified and directed by Engineer-in-charge.
Dehydration and filteration of exisitng transformer oil for transformer of any capacity using centrifugal plant to eliminate foreign particals and to improve die electric strength not less than 40 KV for one minute in 2.5 mm electrode gap as per relevant IS and to bring the acidity within the permissible limit complete all as specified and directed by Engineer-in-charge. Note: (i) Transformer oil required for toping up shall be measured and paid for seperately under respective item of BOQ. (ii) Oil sample are to be collected from top and bottom of the tank and test results to be submitted by the contractor for each sample before and after dehydration and filteration. (iii) Dehydration and filteration of transformer oil shall be carried out by the dehydration machine at site.
Supply and topping up to filling of fresh transformer oil conforming to IS-335 having die electric strength not less than 50 KV in existing transformer installed at different locations complete all as specified and directed by Engineer-n-charge.
Supplying and refixing in replacement silica gel cork breather rubberised gasket, 5mm thick including silica gel for transformer of capacity 50 KVA to 400 KVA complete all as specified and directed by Enginer-in-charge. Note : Colour of silica gel should be deep sky blue.
Taking out old unserviceable drain cocks from the transformers and Supply and fix new gun metal gate valve 25 mm bore along with brass/ gun metal dummy cap with rubbber washers as required at site complete all as specified and directed by Engr-In-Charge.
M & L for preparation of old painted surfaces of 11KV/433V step down transformers of capacity 50 KVA to 160 KVA including removing oilly and greasy spots, cleaning stains, spots with thinner and applying two coats of synthetic enamel paint in all sides by using spray machine including white wash to transformer foundation plinth and lettering MES NO/SM No, capacity, year of installation, serial No in block letters with white paint complete all as specified and directed by Engr-In-Charge.
All as per Ser item No 40.00 above but transformer of capacity exceeding 160 KVA but not exceeding 300 KVA complete all as specified and directed by Engr-In-Charge.
All as per Ser item No 40.00 above but transformer of capacity 315 KVA to 400 KVA complete all as specified and directed by Engr-In-Charge.
Supply only aluminium lugs suitable for cable of size 50 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 70 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 95 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 120 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 150 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 240 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 300 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium lugs suitable for cable of size 400 Sqmm complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable MCCB 400 Amps and supply and fiux MCCB 400 Amps, 415 volts, TPN, 25 KA breaking capacity and thermal maganetic release type complete all as speified and directed.
S&F in replacement of old unserviceable MCCB 250 Amps and supply and fix MCCB 350 Amps, 415 volts, TPN, 25 KA breaking capacity and thermal maganetic release type complete all as speified and directed.
S&F in replacement of old unserviceable MCCB 200 Amps and supply and fix MCCB 250 Amps, 415 volts, TPN, 25 KA breaking capacity and thermal maganetic release type complete all as speified and directed.
S&F in replacement of old unserviceable MCCB 160 Amps and supply and fix MCCB 200 Amps, 415 volts, TPN, 25 KA breaking capacity and thermal maganetic release type complete all as speified and directed.
S&F in replacement of old unserviceable MCCB 63 Amps and supply and fix MCCB 160 Amps, 415 volts, TPN, 16 KA breaking capacity and thermal maganetic release type complete all as speified and directed.
Material and Labour for Framed work of Fe 410-W (Gde-E- 250) quality-A as in doors or gates or panels or other section with gusset plates, rails, braces, sheets, panels etc., with complete, drilled, welding for fixing of steel sheeting or other covering the doors/hinges/panels covers, etc. to be prepared for hanging or sliding with and including hooks and hinges , locking arrangement or hanging door fittings and hanging with fastening and fixing complete as in LT/HT Panel, DB boxes panels including painting of two coats of enamel paint over one coat of zinc coating primer complete all as specified and directed by Engr-In-Charge.
M&L for repair and maint of HT Air break GOD switch to removing carbon/burnt accessories and replacement of unservceable male and female contacts assembly ,belts, back connector plates including treatment with conducting jelly of contact points and removing/replacement of unserviceable jumpering with new ACSR conductor jumpers duly load test the HT UG/OH lines jumpering position/points and provision for required minor spares like screws, nuts, bolts, washers and links are inclusive complete all as specified and directed by Engr-In-Charge. Note: Male and female contact, belt/jumper, MS jumper carrier, back connector plate will be measured and paid separately under relevant item of BOQ.
Supply and fixing of Male contacts/moving contact blade with arching horn having brass contacts suitable for 11 KV Airbreak switch GOD of 200/400 amps rating including galvanised iron bolts,nuts and washers for fixing on post insulators or any other complete all as specified and directed by Engr-In-Charge.
Supply and fixing of female contacts spring loaded brass contacts suitable for 11 KV Airbreak switch GOD of 200/400 amps rating including galvanised iron bolts,nuts and washers for fixing on post insulators or any other complete all as specified and directed by Engr-In-Charge.
Supply and fixing of tinned copper braided flexible belt or jumper 200 Amps/400 Amps suitable for 11 KV GOD including galvanised iron bolts,nuts and washers for fixing complete all as specified and directed by Engr-In-Charge.
Supply and fixing of MS jumper carrier for carrying copper braided belt suitable for 11 KV GOD including galvanised iron bolts, nuts and washers for fixing complete all as specified and directed by Engr-In-Charge.
Supply and fixing of back connector plate suitable for 11 KV GOD including galvanised iron bolts, nuts and washers for fixing complete all as specified and directed by Engr-In-Charge.
M&L for detection of an type fault in HT UG cable(laid in soil at plane area or soil or trenches) with the help of cable fault locator machine with carrying vehicle will be brought by cable fault detection agencies. Span of faulty cable will be trace out by the agencies by meggering HT cable . Note : (i) Detection of fault in one span of length and successful rectification by technicians will be measured as each job. (ii) Technicians will be employed by the contractor. (iii) Earth work and taking out will be measured and paid seprately. (iv) Material for repair and replacement will be measured and paid seprately.
Supply and fix self adhesive reflective radium stickers 5 meter roll , 75 mm wide around the street light poles 1.5 above ground level complete all as specified and directed by Engr-In-Charge.
Cleaning of bushes and grass, cutting the branches of trees if any over ramps and tappered surfaces of two/ four pole structures, transformer yards, lT Panel areas and making good surfaces as existing complete all as specified and directed.
M&L for cable route marker made out of non corroded iron plate with stem of 0.60m long for grouting into the ground including HT cable by engraving / painting complete fixed in PCC including excavation and RF and removing complete all as specified and directed.
Material and labour for routine preventive / breakdown maintenance & repairing of 11KV (Drawout / non drawout trolly type) Vacuum Circuit Breaker (VCB) doing the follwing work :- (i) Taking out VCB trolly from panel and carry out the cleaning dust / durt / any type of spark, general maintenance, oiling, greasing the mechanical / electrical parts such as spring charging motor mechanism, gears, lever spring, operating rod, male & female electric contacts (Jaw contact assembly), bus bar shutter, tightening of nuts and bolts, cleaning any type of arc/ burning patch. (ii) Repairing / Checking the AC/DC wiring, circuit including control fuses, CT & PT fuse and circuit jack, on/off push button, all type of commanding electric tripping / closing coils, all type of IDMT numerical / degital / analog relays, indicating lamp, voltmeter, ammeter, PF meter, gear box mechanism and springs etc., (iii) Relacement and testing of defective / unservisible electrical / mechanical parts. (iv) Reinserting the VCB in panel and setting of all types of relays as per load. (v) Doing all type of standard tests and calibration of different type of relays such as Over current & earth fault relay, Trip circuit supervision relay, Master trip relay, Fuse failure relay. Digital multifunction relay, Auxilary relay for Buch, WTI, OTI trip & alarm, Auxilary relay for PRV trip & MOG Alarm by injucting artificial electric load in the form of overload, short circuit current , and earth fault for tripping function & testing of all relays complete in all respect all as specified and submetting testing report as directed by Engineer-in-Charge.
Notes :- (i) Unserviceable items required to be replaced shall be measured and paid separately. (ii) Minor parts such as oil, grease, rust/ carbon cleaner, Nut/ bolts, wires is included in the unit rate quoted above. (iii) Unit rate quoted against this item shall include the engineer, electrian & labour required for repair / replacement of unserviceable spare parts. (iv) The above work shall be carried out only and only by the OEM (existing make of equipment) Engineer, Electrian. No local / any other ageny, Company Engineer , dealer will be allowed to carryout the work. Engineer will come directy from OEM (existing make of equipment). Contractor will submit the evidance in this regard and will take permission before starting the work. (v) All the mechanical, electrical parts / relays / coils to be replace will be of same make and type as per existing installed on site. (vi) The contractor shall check the existing system of VCBs for maintenance of VCB parts before quoting the tender. (vii) The maintenace of VCB once measured will not be paid again in this contract if any other type of fault come after the servicing. Only spare parts will be paid. No any other type of labour/ Electrian / Engineer cost will be paid saperatly (viii) As the VCB is a critical equipment from the safety point of view for the electric supply system. If any fault comes in the VCBs the contractor will have to attend and rectify the same with in 48 Hrs .Failing to attend the fault within given time a panelty will be imposed @ 1000 / day till the rectification of fault.
Taking down old unserviceable Circuit spout connection R,Y & B 400 A from VCB breaker and supply and fix new Circuit spout connections 100A/ 200A /400 A Capacity replaced by unseriveable one make and model all as per existing complete all as specified and directed by Engr-In-Charge.
Supply and fix Isolating socket contact for 100Amps/200Amps/400Amps Capacity in operation of 11KV VCB all as per existing make and model installed at site complete all as specified and directed by Engr-In-Charge.
Supply and fix VCB Bushing for socket contact for 100Amps/200Amps/400Amps Capacity in operation of 11KV VCB all as per existing make and model installed at site complete all as specified and directed by Engr-In-Charge.
Supply and fix Conductor stud for socket contact for 100Amps/200Amps/400Amps Capacity in operation of 11KV VCB all as per existing make and model installed at site complete all as specified and directed by Engr-In-Charge.
Supply and fix in replacement Electro mechanical based fuse failure relay, 3 pole , Vx 110 AC 50 Hz, type of Make and model all as per existing installed and as directed and specified by Engineer-in-Charge.
Supply and fix in replacement Electro mechanical based Triping relay, Vx 24-27 V, DC type of Make and model all as per existing installed & directed and as specified by Engineer-in-Charge.
Supply and fix in replacement Electro mechanical based Trip circuit supervision relay, 3 pole, Vx 24-27 V, DC, type of Make and model as per existing installed and as directed and specified by Engineer-in-Charge.
Supply and fix in replacement Electro mechanical based Auxiliary relay, 3 pole , Vx1 110-125 V, AC type of Make and model all as per existing installed directed and as specified by Engineer-in-Charge.
Supply and fix in replacement Tripping coil along with solenoid operating on 24 V DC, R 1.7Ω +-5% as per existing make and model installed on site in 11 KV rating VCB.
Supply and fix in replacement closing coil along with solenoid operating on 24 V DC, R 1.7 Ω +-5% as per existing make and model installed on site in 11 KV rating VCB.
Supply and fix in replacement Spring charging motor operating on 220 V AC / DC supply, FL Watts 150, type PMR 5 of make and model as per existing installed on site in 11 KV rating VCB.
Supply and fix in replacement high voltage Porcelain material H.R.C CT / PT ( Current transformenr / Potential transformer) fuse 11 KV rating of make and model all as per existing of suitable length and diameter to be install in 11 KV rating VCB.
Supply and fix in replacement DC power pack of capacity 7AH, 220 / 110 V AC incoming and 24 V DC outgoing all as per existing make and model installed in 11 KV VCB
Supply and fix in replacement Breaker control Switch Three position :-Trip, close and neutral control switch (TNC) for operation of 11KV VCB all as per existing make and model installed on site.
Supply and fix in replacement three phase, 4 digit Digital type ammeter meter having indicators for each phase, accuracy class 0.5, to be install in 11KV VCB as per existing model installed specification.
Supply and fix in replacement three phase, 4 digit Digital type voltmeter meter having indicators for each phase, accuracy class 0.5, to be install in 11KV VCB as per existing model installed specification.
Supply and fix in replacement HRC fuse link type NSD type FA 02 Amps to 20 Amps, 500 V complete all as specified and directed.
Supply and fix in replacement LED pilot lamp Indicator working on AC/ DC power supply on any voltage to be install in 11 KV VCB in any colour as per requirement on site & as per existing make and model installed on site.
Supply and fix in replacement three phase, Digital type power factor meter having indicators accuracy class 0.5, to be install in 11KV VCB as per existing model installed specification.
Supply and fix in replacement Ammeter / Voltmeter Switch, four position :R ,Y, B and off position slelection for operation in 11KV VCB all as per existing make and model installed on site.
Supply and fix in replacement push button NO / NO type for operation in 11 KV VCB all as per existing model installed on site and directed and specifiec by Engineer-in-Charge.
Supply and fix in replacement Bridge Rectifier Diode all as per installed in 11 KV VCB all as per specified and directed by Engineer-in-Charge.
Supply and fix in replacement Epoxy support Insulator 40mm dia, 11KV, single holes of 12mm dia type, 150mm long as per existing make & model. specified and directed by Engineer-in-Charge.
S&F in replacement of CT ( current teansformer) type BWP3, STC 18.4 KA for 1 sec, core 1 :15VA class 0.5, core 2 : 15VA class 5P10, copper wound, P1/P2 type of ratio 100-50/5-5A, 50 Hz as per IS-2705/1992, Ins. Class B, suitable for 11 KV VCB Panels to be installed as per existing model and directed and specified by Engineer-in-Charge.
S&F in replacement of PT ( Potential transformer) suitable for 11 KV VCB Panel, copper wound, P1/P2 type of ratio 11000/110 Volt as per IS 2705-1992, Ins. Class B, 50 Hz, Str-25 KA / 1 Sec, to be installed all as per existing make and model or as directed by Engineer-in-charge.
Supply and fix in replacement LV plug connector suitable for 11 KV VCB controlling all as per existing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement male & female Jaw contact set of rating 11 KV, 800 Amps to be install in 11KV VCB all as per existing installed and specified and directed by Engineer-in-Charge.
Supply and fix in replacement HT vaccum interrupted assembly bottel with flex connection suitable for 11 KV VCB 100Amps/200 Amps/400 Amps capacity for RYB phases as per existing installed make and model complete all as specified and as directed by Engineer-in-Charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron earth strip 25x4mm thick fixed by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia upto 3m height above ground level and watering pipe 20mm dia GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6), type C-2, using 40mm graded stone aggregate, cast iron cover, wire meah etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and direcrted by Engr-in-charge. Notes:- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) GI strip connecting upto pump,Gen set,LT panel and DBs earth connection is included in this item. (iii) GI pipe 40 mm dia protection pipe shall be provided upto Ground level.
N.R.Builders (BID ID -3127494)
Singla Electricals (BID ID -3127488)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .