| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L1 | Accepted-AOC Ok | |
| 2 | L2₹39.6 L+₹1.1 L (2.84%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹40.7 L+₹2.2 L (5.68%)Rejected-Finance WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹41.2 L+₹2.6 L (6.81%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹41.8 L+₹3.3 L (8.47%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹43.4 L
EMD Value
₹86,840
Closing Date
29 Dec 2022, 6:00 pmClosed
GE E/M BASE HOSPITAL DELHI CANTT
GE E/M BASE HOSPITAL DELHI CANTT-110010
REPAIR WORK OF UNSV PARTS OF DG SETs, TRANSFORMER, BOREWELLs, WATER SUPPLY INSTALLATION ETC AND OTHER MISC E/M WORKS AT CGDA AND CENTRAD UNDER GE E/M BASE HOSPITAL DELHI CANTT-10
2022_MES_566855_1
GE/BH-86/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE E/M BASE HOSPITAL DELHI CANTT
Class D Category b(i)
8 documents required · 8 mandatory
₹500
GE E/M BASE HOSPITAL DELHI CANTT
₹86,840
Yes
4 Feb 2023
9 Dec 2022
31 Dec 2022
9 Dec 2022
29 Dec 2022
23 Dec 2022
Amount
M&L for synchronising 750 KVA DG Set with 250 KVA DG set to obtain optimum power output and efficiency including Supply, fixing, connecting the following items complete all as specified and as directed:- (i) MFM Meter EM6400NG RS 485 - 02 Nos (ii) Voltage Monitoring relay VMRD2 - 01 No (iii) Illuminated push button for PLC fault reset with NO element - 01 No (iv) Battery Charger 230V AC/24V DC, 16A - 01 No (v) PLC Programming (micro Logic 1400) - 01 No (vi) Control wiring with 2.5mm, 8 core copper armoured Wire - 20 RM (Approx) (vii) Control wiring with 1.5mm single core copper armoured Wire - 90 RM (Approx) with all accessories.
Comprehensive maintenance and repair 750 KVA DG Set with AMF of CGDA including replacement of defective parts/fitting including all required electrical and mechanical Spares required for comprehensive maintenance during the entire contract period complete all as specified & directed. Make- Cummins
Comprehensive maintenance and repair 250 KVA DG Set with AMF of CGDA including replacement of defective parts/fitting including all required electrical and mechanical Spares required for comprehensive maintenance during the entire contract period complete all as specified & directed. Make- Cummins
Comprehensive maintenance and repair 160 KVA DG Set with AMF of fire fighting including replacement of defective parts/fitting including all required electrical and mechanical Spares required for comprehensive maintenance during the entire contract period complete all as specified & directed. Make- Kirlosker
Note Item No. 02 to 04 (6 Plan + 4 Nos Breakdown visit If require. In a Calendar year and covered panel side, contactor, relay, battery charger, under voltage relay, over voltage relay, and engine side fuel filter, oil filter, air filter-1set , self starter, hose pipe set, clip, controller etc. for each DG sets including service charges for 11 month each DG set
Calibration of injector, PT pump and repair of turbo including minor spare parts installation, testing and commissioning complete all as specified & directed.
S&F in replacement fuse base suitable for cylindrical/DIN type HRC/HBC fuse link type 630/400 A for AMF panel for 750 KVA DG Set complete all as as specified and as directed. Make : L&T Cat Part No SF94437 or Equivalent Model of Siemens/Schneider
S&F in replacement fuse base suitable for cylindrical/DIN type HRC/HBC fuse link type 630/400 A for AMF panel for 160/250 KVA DG Set complete all as as specified and as directed. Make : L&T Cat Part No SF94435 or Equivalent Model of Siemens/Schneider
S&F in replacement power contactor series CK- 3 pole, AC control 600 A, suitable for AMF panel of 750 KVA DG Set complete all as as specified and as directed. Make : L&T Cat Part No CK10CE311 or equivalent Model of Seimens/Schinder
S&F in replacement power contactor series CK- 3 pole, AC control 250 A, suitable for AMF panel of 250 KVA DG Set complete all as as specified and as directed. Make : L&T Cat Part No CK 08CA311 or equivalent Model of Seimens/Schinder
S&F in repair Panel indicator 220 V for main ON/OFF indicator complete all as specified & directed. Make: L&T/Seimens/Legrand
S&F in repair single Phase Preventer as per sample complete all as specified & directed. Make : Minilec Model No VSP-2 or Equivalent Model of L&T/Seimens
S&F in repair Engine Starting Relay as per sample at site complete all as specified & directed. Make Minilec/L&T/Seimens
S&F in repair On-Delay timer of 230 VAC, Range: 0 to 30 sec complete all as specified & directed. Make:L&T Cat No ST803280000 or equivalent Model of BCH/Seimens/Legrand
S&F in repair Under Voltage relay 240/415 Volt as per sample at site complete all as specified & directed. Make: L&T Cat No SL92720B000/SL92720D000 or Equivalent Model of BCH/Seimens/Legrand
Supply, laying & connecting in repair single core, copper conductor, PVC insulated, unsheathed, 1100 V grade (FRLS), 56/0.30, flexible, 4 Sqmm complete all as specified & directed.
Supply, laying & connecting in repair single core, copper conductor, PVC insulated, unsheathed, 1100 V grade (FRLS), 84/0.30, flexible, 6 Sqmm complete all as specified & directed.
Supply and Topping up in replacement inhibitor corrosion (Coolant), green/red, suitable for DG Sets 160 KVA to 750 KVA capacity complete all as specified & directed. Make: Servo/IOC/HP/Castrol/BP
Supply and Topping up in replacement Lubricant oil 20W/40, multigrade, suitable for DG Sets 160 KVA to 750 KVA capacity complete all as specified & directed. Make: Servo/IOC/HP/Castrol/BP
M&L for maintenance & repairing of 1.1 KV, LT ACB panel including dusting, oiling, setting of over current and earth fault relay, if required, laid and servicing like all mechanical function including replacement of no volt coil tripping device complete all as specified and as directed.
M&L for repair to transformer 1000 KVA, 11 KV at CGDA to arrest oil leakage comprising of following operations complete all as specified and as directed: - (a) Disconnecting of transformer main supply input & output. (b) Opening up, top, cover, taking out transformer oil. (b) S&F in repair Porcelien LT 1.1 KV Brass rod & gasket (brass rod 40mm) - 04 Nos (c) S&F in repair Porcelien HT 11 KV Brass rod & gasket (brass rod 16mm) - 03 Nos (d) S&F in repair Silica Gel and Breather - 01 Nos (e) S&F in repair rubber cork sheet 3'x2'x6'mm - 01 No Note:- Transformer oil shall be measured and paid separately under respective item of this Schedule.
S&F in repair Thermostate for Oil Temperature for 1000 KVA Transformer complete all as specified and as directed.
S&F in repair Thermostate for Weinding Temperature for 1000 KVA Transformer complete all as specified and as directed.
S&F in repair HT Bushing with insulator for 1000 KVA Transformer complete all as specified and as directed.
S&F in repair LT Bushing with insulator for 1000 KVA Transformer complete all as specified and as directed.
S&F in repair Insulation material for 1000 KVA Transformer complete all as specified and as directed.
M&L for removing oil leakage from terminal input/output, conservator top cover oil indicator, tab changer, bachhlotz relay (gasket Sheet) packing for 1000 KVA Transformer complete all as specified and as directed.
M&L for Repair to transformer 500 KVA 11 KV at CENTRAD to arrest oil leakage. (a) Disconnecting of transformer main supply input & output comprising of following operations complete all as specified and as directed: - (a) Opening up, top, cover, taking out transformer oil. (b) S&F in repair Porcelien LT 1.1 KV Brass rod & gasket (brass rod 40mm) - 04 Nos (c) S&F in repair Porcelien HT 11 KV Brass rod & gasket (brass rod 16mm) - 03 Nos (d) S&F in repair Silica Gel and Breather - 01 Nos. (e) S&F in repair Rubber cork sheet 3'x2'x6'mm - 01 Nos Note:- Transformer oil shall be measured and paid separately under respective item of this Schedule.
S&F in repair Thermostate for Oil Temperature for 500 KVA Transformer complete all as specified and as directed.
S&F in repair Thermostate for Weinding Temperature for 500 KVA Transformer complete all as specified and as directed.
S&F in repair HT Bushing with insulator for 500 KVA Transformer complete all as specified and as directed.
S&F in repair LT Bushing with insulator for 500 KVA Transformer complete all as specified and as directed.
S&F in repair Insulation material for 500 KVA Transformer complete all as specified and as directed.
M&L filtration and refilling of Transformer oil & alike for various equipment installed at CGDA and CENTRAD through filtration machine to achieve required di-electric strength 50 kVA complete to entire satisfaction of Engr-in-Charge complete all as specified and as directed. Note:- (a) Quoted rate shall deemed to including testing of oil before filtration and after filtration of transformer, OCB & other equipment.(b) Result before filtration & after filtration of oil (Test Certificate) shall be submitted by the contractor to Engr-in-Charge before claiming of RAR/ Final bill.
Cleaning of fuel tank made of MS sheet of 750 KVA DG Set of 1000 Litre capacity approx, by draining out fuel in a separate container, taking out all silt/ dirt deposition inside the tank, cleaning it completely by manual labour and necessary T&P and refitting and connecting with fuel pipes with DG sets all as per site requirement complete all as specified and as directed.
All as per Ser item No. 36.00 here-in-before but for 250 KVA DG Set of 360 Litre capacity complete all as specified and as directed.
S&F in repair battery, SMF, 12 Volt, 180AH capacity complete all as specified and as directed. Make Exide Express or equivalent Model of Luminous/Amara Raja/Okaya/Amron/Tata Green
S&F in repair battery charger suitable for 750 KVA DG set with charging capacity 48 Volt DC complete all as specified and as directed. Make:- TEKNIKA/Kirloskar/Exide
S&F in repair battery lead with stranded copper conductor of size 95/70 Sqmm, single core, PVC insulated, flexible, 0.6 M long along with battery terminal for positive and stator terminal duly soldered complete all as specified and as directed.
M&L for topping up of transformer oil for transformers/Voltage stabilizer installed at different location CGDA complete all as specified and as directed. Make:- SAVITA/IOC/ POWER/ Servo/HP/Castrol/BP
M&L for painting of transformer of capacity 1000 KVA by scrubbing & removing of old paint & re-painting the same using one coat of synthetic enamel paint of existing colour complete all as specified and as directed.
S&F in repair ammeter digital type 0-100 Amp, including necessary connection complete all as specified and as directed.
S&F in repair Volt meter digital type 0-500 Volts including necessary connection complete all as specified and as directed.
S&F in repair 100 Amp MCCB TPN, 25 KA, adjustable thermal setting, 0.8-1.0x IN thermal release, including necessary copper cable & flexible PVC conduit for internal connection for distribution complete all as specified and as directed. Make L&T Cat No SL97209000 or equivalent Model of Make mentioned in PS.
All as per item No. 45.00 here in before but 125 Amp, MCCB, TPN, 35 KA, complete all as specified and as directed. Make L&T Cat No SL 986070000 or equivalent Model of Make mentioned in PS.
All as per item No. 45.00 here in before but 150/160 Amp, MCCB, TPN, 35 KA, complete all as specified and as directed. Make L&T Cat No SL 986080000 or equivalent Model of Make mentioned in PS.
All as per item No. 45.00 here in before but 200 Amp, MCCB, TPN, 35 KA, complete all as specified and as directed.
All as per item No. 45.00 here-in-before but 400 Amp, MCCB, TPN, 35 KA, complete all as specified and as directed. Make L&T Cat No SL 978840000 or equivalent Model of Make mentioned in PS.
All as per item No. 45.00 here-in-before but 630 Amp, MCCB, TPN, 35 KA, complete all as specified and as directed. Make L&T Cat No SL 9945320000 or equivalent Model of Make mentioned in PS.
S&F in repair fuel pipe set suitable for 750KVA, 160 KVA, 82.5 KVA, DG set 20 KVA & 10 KVA DG set complete all as specified and directed.
M&L in repair Cable jointing kit for 11 KV (Earthed) grade cable, suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 Sqmm, for outdoor termination, heat shrink type joint, with jointing material and accessories complete all as specified and directed.
M&L in repair Cable jointing kit for 11 KV (Earthed) grade cable, suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 Sqmm, for indoor termination, heat shrink type joint, with jointing material and accessories complete all as specified and directed.
Supply, laying and connecting in repair 6 Sqmm, 2 Core XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade, LT UG electric cable with stranded aluminium conductor including lugs, glands etc, laid in trenches or fixed on wall or drawn through in GI pipe complete all as specified and as directed.
Supply, laying and connecting in repair 10 Sqmm, 2 Core XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade, LT UG electric cable with stranded aluminium conductor including lugs, glands etc, laid in trenches or fixed on wall or drawn through in GI pipe complete all as specified and as directed.
Supply, laying and connecting in repair 25 Sqmm, 3.5 Core XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade, LT UG electric cable with stranded aluminium conductor including lugs, glands etc, laid in trenches or fixed on wall or drawn through in GI pipe complete all as specified and as directed.
Disconnection of terminal of LT cable and locating, pin point fault in LT cable 1100V grade of any size including to & pro hire charge of special T&P complete all as specified and as directed.
Disconnection of terminal of HT cable and locating, pin point fault in HT cable 11000V grade of any size including to & pro hire charge of special T&P complete all as specified and as directed.
S&F in repair single phase under voltage relay 20-110V AC/DC CT Secondary 5A complete all as specified and as directed. Make L&T Cat Part No MV12AA00X00 or equivalent Model of Seimens/Schinder or any other Make mentioned in PS.
S&F in repair 3 Phase over current, earth fault relay 20-110V AC/DC 4 No programmable complete all as specified and as directed. Make L&T Cat Part No MC31AAXX000 or equivalent Model of Seimens/Schinder or any other Make mentioned in PS.
S&F in repair 3 Phase over current , earth fault relay 20-110V AC/DC CT Secondary 5A complete all as specified and as directed. Make L&T Cat Part No MRP11A50X00 or equivalent Model of Seimens/Schinder or any other Make mentioned in PS.
Supply only in repair Rubber mat 1 mtr x 2 mtr x 19 mm (HT), Tensile Strength for Temp (-10 to 55 DEG. C, 15N/Sqmm (Min), Elogation at Break For Temp (-10 to 55 DEG. C -250 DEG% MIN, Insulation Resistence in water -10,00,000 M ohm (min) Approved by IS 15652/2006, B.I.S+CPRI+ERDA Approved complete all as specified and as directed. Make- Joyti/ Dunlop/ CEAT
Supply only in repair Rubber mat 1 mtr x 2 mtr x 10 mm (LT) Tensile Strength for Temp (-10 to 55 DEG. C, 15N/Sqmm (Min), Elogation at Break For Temp (-10 to 55 DEG. C -250 DEG% MIN, Insulation Resistence in water -10,00,000 M ohm (min) Approved by IS 15652/2006, B.I.S+CPRI+ERDA Approved complete all as specified and as directed. Make- Joyti/ Dunlop/ CEAT
S&F in repair ultra Heavy duty Contactor capacitor duty for Power capacitor in KVAR advance APP technology, lower operating losses 0.35W/KVAR complete all as specified and as directed. Make Make L&T Cat Part No LTXL or equivalent Model of Seimens/Schinder or any other Make mentioned in PS.
Supply in Repair Hand Gloves seamless suitable for working pressure 1100 Volts and tested up to 11000 Volts complete all as specified and as directed.
S&F in repair Fuel indicator Flexi pipe external DHPP 'N' tank for suitable DG Set length of flexiable pipe as existing complete all as specified and as directed.
S&F in repair EP 26-12, 12 Volts, Acid Lead battery, dimension 175x175x166(mm) complete all as specified and as directed. Make Exide Powersafe Plus or equivalent Model of Luminous/Amara Raja/Okaya/Amron/Tata Green
M&L for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, Exc 500 Litre and not exc 1000 Litres Tank capacity complete all as specified and as directed.
M&L for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, Exc 1000 Litre and not exc 5000 Litre Tank capacity complete all as specified and as directed.
M&L dewatering, cleaning of under Ground reservoir, 35000 Litre capacity, with high pressure jet to remove all mosses, algae and dirt and removal of dirty water alongwith sludge machines/industrial vacuum cleaners and disposal of the same at safe distance including scrubbing of internal surface by steel wire brushing, removing the dirt completely using industrial vacumm cleaner and sterilizing the complete internal surface of the tank by using ISI mark, grade I, bleaching powder and marking the date of cleaning using synthetic enamel paint in white colour over black background in six stages cleaning process, as specified here in after complete all as specified and as directed: - (i) Dewatering the tank with portable submersible pump set with flow rate of 30,000 Litres per Hour. (ii) Removal of left over dirty water and sludge with special sludge removal pump set having capacity up to 1.7 lakh Litres per Hour. (iii) Cleaning of wall, ceiling and floor by high pressure rotary water jet with the help of German equipment which create pressure of 80-120. (iv) Removing of remaining sludge from the floor with the help of industrial vaccum cleaner. (v) Spraying of non toxic biodegraded, eco friendly, anti bacterial agent certified by a Govt approved lab to disinfect the tank from harmful pathdons. The dose utilise shall be as per OECD guide No 432. (vi) Treatment of inside tank be exposing UV radiation to kill the suspended or floating bacterial remaining in the tank.
All as per item No 70.00 here in before but cleaning of under Ground Sump of 20,000 Litres capacity complete all as specified and as directed.
All as per item No 70.00 here in before but cleaning of under Ground Sump of 65000 Litres capacity complete all as specified and as directed.
Supply, installation, testing and commissioning in repair submersible pump set, electric driven, 415 Volt, TP, suitable for 200 mm dia bore well casing pipe complete, 5WHP, including 40 mtrs long submersible cable of size 6 Sqmm, three core and suitable starter complete all as specified and as directed.
S & F in repair 50 mm bore, galvanised iron tubing, medium grade with all fittings like sockets, elbows, bends, Tees, unions, short pieces etc. laid in trench, in any length including taking down old water tubing complete all as specified and as directed. Note: Necessary Excavation and earth work shall be measured & paid separately
All as per item No 74.00 here in before but 40mm bore pipe complete all as specified and as directed.
All as per item No 74.00 here in before but 32mm bore pipe complete all as specified and as directed.
All as per item No 74.00 here in before but 25 mm bore pipe complete all as specified and as directed.
All as per item No 74.00 here in before but 20mm bore pipe complete all as specified and as directed.
All as per item No 74.00 here in before but 15mm bore pipe complete all as specified and as directed.
S&F in repair gun metal gate/glob valve heavy duty (ISI marked) with iron wheel head screwed both ends, suitable for 15 mm bore iron pipe including testing complete all as specified & directed.
All as per item No 80.00 here in before but suitable for 20mm bore pipe complete all as specified and as directed.
All as per item No 80.00 here in before but suitable for 25mm bore pipe complete all as specified and as directed.
All as per item No 80.00 here in before but suitable for 32mm bore pipe complete all as specified and as directed.
All as per item No 80.00 here in before but suitable for 40 mm bore pipe complete all as specified and as directed.
All as per item No 80.00 here in before but suitable for 50 mm bore pipe complete all as specified and as directed.
S & F in repair 40 mm bore, galvanised iron tubing, heavy grade, both end threaded and duly welded with heavy duty GI Sockets complete all as specified and as directed.
Lifting & Lowering of existing Submersible pump set, repairing pump set with taking out carefully of 18 Nos. column pipe of 50/80 mm size, each length of 3 mtr with flange joints, repairing/ welding all as required at site to column pipe, including proper fixing and connecting of cable with pump set and column pipe and making connection with existing starter complete all as required at site, as specified and as directed. Note:- Flange type joint with Jointing material like Flange, nut-bolts, gasket sheet etc shall deemed to be included in quoted rate.
Supply, laying & connecting in repair flat, 3 core, copper conductor PVC insulated & PVC sheathed cable 1100 Volts grade, size 10 Sqmm, laid in and including 40 mm dia PVC conduit fixed to wall/ in duct complete all as specified and as directed.
Supply, installation, testing and commissioning in repair non clog single phase dewatering pump, Vertical, Monoblock, submersible pump sets, IP 68 Protection, class F, BI- directional Mechanical Seal, 1.1 HP DN 50mm, upto 480 LPM, with built in thermal overload protection and float switch, free flow impellers, Suitable for pumping surface water, rain water, waste water containing solids, drainage of sumps liable to flood, agricultural pits and canals with the following specifications complete all as specified and as directed:- (i) Cast iron- pump casing (ii) cast iron - impeller (iii) Rotor Shaft- Chrome Steel Make- CG/ KSB/ Kilosker or make mentioned in PS.
All as per item No 89.00 here-in-before but 1 HP/0.75 KW, DN 35mm, 1.8-10.8m, upto 400 LPM complete all as specified and as directed. Make CG Cat No STPM12 or equivalent model of KSB/ Kilosker or make mentioned in PS.
Supply, installation, testing and commissioning in repair Induction Motor, Three phase, 415V, 50x40mm, Head -46.0, 3.7KW/5HP, 50 HZ complete all as specified and as directed. Make Kirlosker Cat No KDS 550++ or equivalent model of KSB/ CG or make mentioned in PS.
Supply, installation, testing and commissioning in repair Centrifugal Monoset Pump, Three phase, 415V, 65x50mm, RPM -2880, 2 pole, Head -46.0 Mtr, 3.7KW/5HP, 50 HZ complete all as specified and as directed. Make CG Cat No MBHH5Z or equivalent model of KSB/ Kilosker or make mentioned in PS.
Supply, installation, testing and commissioning in repair submersible pump set, electric driven, 415 Volt, TP, suitable for 150/200 mm dia bore well, casing pipe complete up to 3 WHp including 40 Mtrs long submersible cable of size 6 Sqmm, three core and suitable starter complete all as specified and as directed.
Supply, installation, testing and commissioning in repair submersible pump set, electric driven, 36 Uf, 440 Volt, 2780 RPM, Suitable for 40 mm Dia pipe, Head Max 12Mtr, Maximum Discharge 12000 LPH, Max Solid Size 38mm, up to 1.5 WHP, including 10 mtrs long submersible cable of size 2.5 Sqmm, three core and suitable starter complete all as specified and as directed.
Supply and fix in replacement LED decorative post of lantern 35 Watt fittings including all accessories complete fixing accessories and clamp including 4 metre height black painted galvanized pole, fixed in position including necessary PCC work and excavation as per manufactuer's instruction all as specified and directed by Engr-in-Charge. Make:- For fitting CG , cat part No:- LPTOI-45- CDL/ T or equivalent in Philips, GE, Havell's
S&F in repair/ replacement MCCB 630 Amp Three pole , 50 KA Adjustable thermal & fixed magnetic setting ICS 75% of Icu, suitable for installation inside Panel including addition alteration to existing copper/ aluminium busbar system all as specified and directed By Engr-in-Charge. Make Havells:IHLLFCT0630 or equivalent Model of make L&T/ Schneider Note:- (i) Quoted rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 630 Amp four pole , 50 KA suitable for installation inside Panel including addition alteration to existing copper/ aluminium busbar system all as specified and directed By Engr-in-Charge. Make Havells:IHLLNFC0630 or equivalent Model of make L&T/ Schinder Note:- (i) Quoted rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 400 Amp Three pole , 50 KA suitable for installation inside Panel including addition alteration to existing copper/ aluminium busbar system all as specified and directed By Engr-in-Charge Make Havells:IHLLNFCT0400 or equivalent Model of make L&T/ Schneider Note:- (i) Quoted rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 400 Amp four pole, 50 KA suitable for installation inside Panel including addition alteration to existing copper/ aluminium busbar system all as specified and directed by Engr-in- Charge Havells:IHLLNFCF0400 or equivalent Model of make L&T/ Schinder Note:- (i) Quoted rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 250 Amp three pole , 50 KA suitable for installation inside Panel including addition alteration to existing copper/ aluminium busbar system all as specified and directed By Engr-in-Charge Havells:IHLLNFCT0250 or equivalent Model of make L&T/ Schneider Note:- (i) Quoted rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 250 Amp four pole , 50 KA suitable for installation inside Panel including addition alteration to existing copper/ aluminium busbar system all as specified and directed By Engr-in-Charge Havells:IHLLNFCF0250 or equivalent Model of make L&T/ Schneider Note:- (i) Quoted rate include the addition/ alteration in busbar system.
S&F in repair/ replacement MCCB 200 Amp Three pole , 50 KA suitable for installation inside Panel including addition alteration to existing copper/ aluminium busbar system all as specified and directed By Engr-in-Charge Havells:IHLLNFCT0200 or equivalent Model of make L&T/ Schneider Note:- (i) Quoted rate include the addition/ alteration in busbar system.
S&F in Repair/ replacement MCCB 200 Amp four pole , 50 KA suitable for installation inside Panel including addition alteration to existing copper/ aluminium busbar system all as specified and directed By Engr-in-Charge Havells:IHLLNFCF0200 or equivalent Model of make L&T/ Schneider Note:- (i) Quoted rate include the addition/ alteration in busbar system.
S&F in repair/ replacement MCCB 125 Amp Four pole , 50 KA suitable for installation inside Panel including addition alteration to existing copper/ aluminium busbar system all as specified and directed By Engr-in-Charge Havells:IHLANECF0125 or equivalent Model of make L&T/ Schinder Note:- (i) Quoted rate include the addition/ alteration in busbar system.
S&F in repair/ replacement MCCB 100 Amp Four pole , 36 KA suitable for installation inside Panel including addition alteration to existing copper/ aluminium busbar system all as specified and directed By Engr-in-Charge Havells:IHLANECF0100 or equivalent Model of make L&T/ Schinder Note:- (i) Quoted rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 160Amp four pole, 27 KA suitable for installation inside Panel including addition alteration to existing copper/ aluminium busbar system all as specified and directed By Engr-in-Charge Havells:IHLANECF0160 or equivalent Model of make L&T/ Schneider Note:- (i) Quoted rate include the addition/ alteration in busbar system.
Supply and fixing in repair of digital grounding device 1 phase, residual current 0.001 (Amps) each set digital home electrical equipment and components and supply circuit protection devices and accessories digital grounding device 1 phase mode of protection 3 modes 1 phase 3 wire capacity 12 frequency 60 Hrtz reference capacity 170pf maximum continuous 255 volts, 275 impulse response time less than 25 mode of protection 3 modes 1 phase 3 wire residual voltage 8/20 mocro sec;1.59 kva maximum leakage current 20, frequency 60 herts feerency capacitytance at 1 kHz 1700 PH maximum surge current 8/20 micro second, ka input voltage 240 volt ; ISO 9001, ISO 14001. (With All Accessories) complete all as specified & directed. Make- SN Engineering/ Protrat/ Enjesco
Supply and lay in replacement of Pipe PVC( UPVC) class “A” conforming to IS 13592 including special, OD 75mm dia complete all as specified & directed.
Supply and lay in replacement of Pipe PVC( UPVC) class “A” conforming to IS 13592 including special, OD 65 mm dia complete all as specified & directed.
Supply and lay in replacement of Pipe PVC( UPVC) class “A” conforming to IS 13592 including special, OD 50 mm dia complete all as specified & directed.
Supply and fixing in replacement of Pipe PVC valves class “A” for UPVC pipe of OD 50 mm dia complete all as specified & directed.
Supply and fixing in replacement of Pipe PVC valves class “A” for UPVC pipe of OD 65 mm dia complete all as specified & directed.
Supply and fixing in replacement of Pipe PVC valves class “A” for UPVC pipe of OD 75 mm dia complete all as specified & directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation/ fixing pole/ laying cable and pipe line etc or for man hole etc not exc 10 sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick using excavated soil complete all as specified and directed.
Removing excavated Soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for providing dry river sand as in sand cushioning to under ground electric cable including punning down of sand in layer complete all as specified and directed by Engr-in-Charge. Note: for measurement purpose punned thickness of sand only will be considered.
Supply and Laying burn brick size 225 mm X 113 mm X 75 mm etc complete all as specified and directed.
Supply, installation and testing in replacement of online electrostatic non-chemical water treatment system with electrically operated control panel to be fixed on sub header line suitable for 200 TR AC Plant. The outer casing shall be of 304 grade stainless steel with both ends flanged and capable preventing scale formation. The same shall be suitable for water flow rate 3000 LPM each dia of pipe 6” / 150 MM in condenser circuit. The work includes cutting of existing GI/MS sub header and providing mild steel flange heavy duty and joining with reducer, nut & bolts, gaskets at both ends with welding and modification in existing system complete as reqd and complete all as specified & directed. MAKE: ‘Scale-off’ Model No. 7011 by M/s Weldon Engineers (India) OR equivalent Model of Make Hydrokon/ Dolphin Note:- (i) The installation & testing shall be carried out in the presence of rep of OEM and contractor has to submit test report duly signed by the Rep of OEM & Engr-in-Charge. (ii) The contractor has to upload a concent letter or MOU from any OEM i.e Scale-off (M/s Weldon Engineers (India) / Hydrokon/ Dolphin for the same failing which Financial Bid will not be opened.
A B K Enterprises
Flint India
J.P. Enterprises
D P ENTERPRISES
Shiv Enterprises
Iconic Engineers
SANJEEV ENTERPRISES
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .