| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹43.6 L+₹1.0 L (2.41%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-Finance NOT ADMITTED BEING L2 | |
| 3 | L3₹43.8 L+₹1.3 L (2.95%)Rejected-Finance 1501 BHAGWATI EMINENCE SAVITRIBAI PHULE MARG BESIDES R R PATIL GARDEN SECTION 13 NERUL E NAVI MUMBAI | RAIGAD | MAHARASHTRA | 400702 | L3 | Rejected-Finance NOT ADMITTED BEING L3 | |
| 4 | L4₹43.9 L+₹1.3 L (3.13%)Rejected-Finance | L4 | Rejected-Finance NOT ADMITTED BEING L4 | |
| 5 | L5₹47.7 L+₹5.1 L (11.9%)Rejected-Finance F 402 AMBIKA APARTMENT PLOT A 9 SECTOR 20 NERUL W NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L5 | Rejected-Finance NOT ADMITTED BEING L5 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
7 Nov 2023, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
REPAIRS REPLACEMENT OF ROOF COVERING SHEET TRUSSES FLOORING HARDSTANDING AND OTHER MISC WORKS IN INS TUNIR AT NAVAL STATION KARANJA
2023_MES_622665_1
8746/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE NW KARANJA
D and above a i
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹90,000
Yes
25 Jan 2024
11 Oct 2023
9 Nov 2023
11 Oct 2023
7 Nov 2023
24 Oct 2023
Amount
Notes : (i) The work consists of 01 job as under:- JOB (A) : TPP 23-24 Ser No. 24 (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department. ITEMS FOR JOB 'A'
Note:- The Unit Rate quoted in r/o Ser item No 1.02 to 1.71 are deemed to include for the following and nothing extra will be paid for these works: 1. Supplying, erecting and use of scaffolding upto required height (max 25 to 30m) or upto 8th floor height with necessary H-frames, pipes, couplers, buckles, bracing, top platform with support railing at top etc. at all levels of building including carriage of the materials to the location, erecting, fixing the scaffolding and dismembering the same after working and taking away the scaffolding materials etc. complete as per direction of Engineer-in-charge. 2. Supplying, erecting & use of temporary bamboo scaffolding around the building as required. The scaffolding is to be secured properly in position by bracings, ties clamps, etc. complete including providing and erecting working platform at all heights as required, including removal after completion of work all as per direction of Engineer-in-Charge.
Dismantling plain or corrugated steel sheeting ,any gauge ,thickness incl Nainital or similar pattern roof covering complete all as specified and directed
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tenstile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed
S&F pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.5mm thick of an colour having tenstile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed
Dismantling of asbestos cement (corrugated, semi-corrugated, etc.) sheets any thicknes in roof covering complete all as specified and directed
S&F Asbestos cement 6mm thick corrugated or semi-corrugated sheets in roof firxed with L-type or J-type crenked hook bolts complete all as specified and directed
S&F Asbestos cement 6mm thick in two pieces adjustable plain ridge fixed wirth L-type and J-type hook bolts complete all as specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed
S&F Steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 Grade St-240 complete all as specified and directed.
M&L for framed work such as grills, gratings,post of angle iron etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed Note:-Posts/struts of angle iron made to shape shall be welded to existing angle iron bracket of security wall, contractor shall make his own arrangement for welding for boundary wall by using gen sets or any alternative arrangement complete all as specified and as directed.
S&F framed work in doors or gates (ornamental) of angle or other section with gusset plates, rails, braces, holdfast etc, of grade Fe 410-W ( Gde E-250 ) quality A complete drill for fixing of steel sheeting or other covering . Doors, etc to be prepared by hanging and sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering , running, rails & guide) and hanging also fastening and fixing complete all as specified and directed.
S&F Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes Fe 410 W (Gde-E-250) quality-A complete all as specified and directed
M&L Painting to new or previously untreated steel surfaces including prepration applying one coat of red oxide primer with including two coats of synthetic enamel paint complete all as specified and directed
M&L for applying two coat of glossy floor guard water based paint, anti-skid, exterior grade (Platinum Series) floor coating to old unrteated concrete surface, cement plastered floors/ surface, concrete floors, cement pavers block, chequared tiles, clay tiles etc similar description of work over one coat of approved primer including necessary prepartion prior to painting on surface with hose to remove loose dust and scrub with wire brush to remove algae, fungus and moos growth complete all as specified and directed Note:- 1. Allow 7-8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed.
S&F 140 micron frosted decorative film fixing on door and window glass to reduces the amount of heat and radiation caused by the sun's rays and visible light transmittance less than 4% pane, adjuct the axact size to fit for windows and doors glass pane all as specified and directed . Make Garware sun control and 3M or equivalent as approved by GE
All as per BOQ Ser No 1.15 but textured and gradient decorative pattern film complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
M&L for highly glossy dark coloured tiles design in vertical surface 1200x600x8-10mm /900x600x8-10mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match and 3-5mm thick and 7-8 mm deep PVC spacer fixed at tiles joints over & including 10 mm thick rendering or bedding layer in cement mortar 1:6 complete all as specified and directed.
M&L for stone finish kraft cladding wall tiles 15-20mm thick (Square/ rectangular) area of each tiles n exc 0.36 Sqm etc, set and jointed in neat cement slurry and pointed in white or coloured cement to matchover & including 20 mm thick rendering or bedding layer in cement mortar 1:3 complete all as specified and directed. Note :- Design, colour and pattern as per approved by GE
M&L for 10-12 mm thick glossy finish heavy duty vitrified tiles for parking/ path etc (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and jointed in white/coloured cement to match over& including 10 mm thick screed bed in cement mortar in 1:4, complete all as specified and directed
M&L for mirror finished double charged vitrified tiles 7 to 8mm thick (square/ rectangular) area of each tile not exceeding 0.36 sqm but not exceeding 1 sqm in floors etc set and jointed in neat cement slurry and jointed in white/coloured cement to match over and 3-5mm thick and 7-8 mm deep PVC spacer fixed at tiles joints over & including 10 mm thick screed bed in cement mortar in 1:4, complete all as specified and as directed
M&L for mirror finished double charged vitrified tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.42 sqm but not exceeding 1 sqm in floors etc set and jointed in neat cement slurry and jointed in white/coloured cement to match over and including 10 mm thick screed bed in cement mortar in 1:4, complete all as specified and as directed
S&F in repair vertical/ roller blinds for windows/ door/ ventelator of any colour and pattern as approved including connected items ie. rod, hook etc and complete fitting all as specified and as directed
S&F in repair venetian blinds for windows/door/ventelator of any colour and pattern as approved including connected items ie. rod, hook etc and complete fitting all as specified and as directed
S&F PVC SHEET WALL PANELLING of thickness 5 mm consisting of panels of desired size stuck on inner frame work of 50mm wide strips of 5 mm thick Prelam PVC Sheet. The panel & strips shall be Manufactured by an ISO-9001-2008 certified Company. The strips should have in their center grove of 6 mm wide and 1 mm depth for sinking the head of the screw used to fix the strips to the wall vertially at an equal interval of 10" between two PVC strips. The PVC strips shall be fixed to the wall using 65 mm long MS Screws through the groove in the strips by using PVC fasterners. The distance between two screw shall bot be more than 200mm. A groove of 2mm may be left at the joint of two panels for aesthetic looks. The exact size of the panel and correspondingly of the grid may vary depending on the size of the wall. Optionally a strps of 5 mm thick PVC sheet of width 75 mm feathered at the edges shall be stuck at the places where two panels are joined, using solvent cement including U channel at joints of two PVC sheet on wall and corner moulding as required as per manufacturing instruction including dismantling of existing panelling complete all as specified & directed Note:- Design and pattern as per directed by GE
S&F in repair, decorative WPC sheet (Wood Plastic Composite) 24-26 mm thick having density 600Kg/Cum and fixed to wall & ceiling panelling/ cladding with self drilling screws including necessary frame of aluminium section 51x35x.55mm and 600 mm c/c 51x32x.55mm grid work and corner mouldings as required as per manufacturing instruction and complete all as pecifed & directed. Note:- Design and pattern as per directed by GE
Cleaning of non accesible concrete roof, galvalume/ asbestos sheet roof by removing unwated growth vegtations, plants, silt and waste from roof etc and removing debrish form out of MoD land complete all as specified and directed
M&L for cleaning of RCC SWT tank by dewatering removing all deposite materials like sand silt, sludge, impuritie etc, washing of side walls, scraping with iron brush to removal all type of scales, filling up cavaties by cement motar 1:1 and washing walls with lime powder complete all as specified and directed
S&F Single side writing informatory stainless steel reflecting Sign Boards size 4'x3' having with Aluminium sheet base of 2mm thickness having retro reflective tape base and front colour and matter of sign board will be furnished by Engr-in-Charge.The frame of Sign board shall be 2'' outer dia Square stainless steel pipe and having two legs of stainless steel Square pipe 9' long Each of 2'' outer dia square pipe the board shall be grouted in PCC work of size 350x350x450mm including taking down of existing complete all as specified and as directed.
M&L in repair fabrication of aluminium composite panel of 5mm thick with 0.5 mm aluminium core/skin as a tap and bottom layer, middle ;ayer 3mm thick of polythincore (LDPE) and finally with PVDF coating 28 to 32 micron and joints filed with silicon sealant and including aluminium frame of section 37.5mm x 25mm x 1.6mm fixed on the wall/ columns as a cladding and on ceiling of steel structure/ RCC celing withscrew complete incl dismantling of old decayed panels all as directed and as per manufacture's instruction, coloured/texture pattern as decided complete all as specified and as directed.
S&F 12 mm Plywood, grade BWP, type BB, fixed with adhesive & screws to timber frame work complete all as specified and directed
S&F 6 mm Plywood, grade BWP, type BB, fixed withadhesive &screws to timber frame work complete all as specified and directed
M&L in repairs cupboard, cabinate, wardrobe and kitchen, TV cabinate like similar work fabricated using 18/19 mm thick high density fibre board (HDF) exterior grade, fixed with each other using solvent adhesive and fixed to timber frame work with screw complete all as specified and directed
S&F Continuous (piano) hinges 30mm width of flaps, brass, bright finish or electrogalvanised complete all as specified and directed
S&F 'L' Bihari hydraulic 0 crank, auto hinges 180 degree openable, stainless steel hinges 125x63 mm long bright polished fix to steel chowkhat/timmer frame work with screw or nut or bolt complete all as specified and directed
S&F magnetic catcher 55x29 mm size for continuous opening and closing of doors shutter like use for door megnet lock, cupboard magnetic lock, wardrobe, and similar use incl all fitting like screw complete all as specified and directed
S&F stainless steel handle fabricated type, anodised 150mm size complete all as specified directed
S&F stainless steel 316 grade framed work fancy/ornamental type in Gates/ stair hosing work, ladders and other similar works including all or any type of welding, holdfast, locking arrangement, followed by buffering and polishing for smooth finish complete all as specified and as directed
M&L wood panel 25mm thick (premium quality) fixed in stainless steel gates and similar work with necessary screw, nuts, bolts etc exterior grade, waterproof, wood having no cracking and deformation shell and anti-scratch combining strength and durability of wood panel exterior and interior wall/ gate/ door decorative cladding, ceiling, floor, roof decking and insert in stainless steel gate/ door complete all as specified and directed
M&L for racking out joints of ceramic tiles as in wall or floor upto 6-7mm deep and repair with neat epoxy adhesive and white cement as required with pigment using chemical for quick setting and stop leakage as specified by manufacturer and making good and check up to 7 days for stop leakage complete all as specified and as directed
S&F in repair 12 mm thick vertical toughened glass including frame as in door shutters / partition with including stainless steel SS-304 patch fitting fixed with Anchor fastner, etching, pivot arrangements complete each glass panes shall be exceeding 1.5sqm, but not exceeding 2 sqm each, all edges of glass shall be diamond polished, accurate designed holes to be installed by means of steel fittings including upper patch, lower patch, lock key plate, provision of locking system, etc. Including providing "PUSH" & "PULL" sticker lables of approved design (as per site requirement). complete all as specified and as directed.
All as per BOQ item No 1.41 above but 12mm thick fully/ partily (as per site requirement) frosted high quality toughened glass with unit colour digital logo and other design/pattern like text in hindi/ english furnished by GE etc. Colour of digital logo/pattern and matter will be furnished by GE
S&F aluminium (extruded section body) hydraulically regulated designation No-3 universal type, suitable for door shutters of 851 to 1000 mm in width and of weight betwwen 61 to 80 Kg and fixed complete all as specified and directed
S&F double action floor spring hydraulically regulated made up to min 1.25 mm thick aluminium alloy sheet foundation box main body with stainless steel cover governing pivot made of brass other parts made of mild steel heavy duty & fixed, complete all as specified and as directed
S&F in repair 30 mm dia stainless steel handle of 45 cm long and fixed to toughned glass as per manufacturer's instructions. complete all as specified and as directed.
S&F in repairs stainless steel glass lock fixed to toughened glass as per manufacturer's instructions complete all as specified and as directed.
S&F in repairs stainless steel wire cloth with 8% nickle . 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple complete all as specified and directed
S&F in replacement 10 to 12mm thick plaster of paris sheets fix in ceiling with and including grid made out of angles and tees of one mm thick G I sheets fixed at not more than 45cm centre to centre in both directions. GrId secured by vertical tai of GI sheet angle at not more than 1.2m centre to centre in both directions. The veritical tai of GI sheet angle shall be fixed with M S dash through fastners of 8 mm dia. The ceiling is to be provided at different profiles like curved, flat, sunk, tapered edge and or raised mouding, the joints shall be filled with plaster of paries, necessary arrangement/cut outs hole for ceiling light as required as required number complete all as directed Note:- 1. Items rate shall be include any height of bldgs for scaffolding as all arrangement all as specified and directed by Engr-in-Charge. 2. Rate to be included for all kinds of profiles and cut outs required for light fixtures, Speakers, Smoke detector, trap doors and AC grill in the ceiling. Provision for light fittings, AC grills and diffusers have to be made at no extra cost supported with tees, Angles, etc. suitably fixed all complete as per direction. The area of these cutouts which is less than 0.6 sqmt for one unit will not be deducted while measuring the ceiling area. 3.The contractor must co-ordinate with electrical & AC contractor for working out various levels for the false ceiling & make the marking on the walls / columns before starting the false ceiling work.
All as per BOQ item no. 1.48 above but providing, making and fixing Gypsum cornice cove (inside height 150 - 200 mm and border 75 mm) or charcoal moulding strip to hide strip/cove light in ceiling or to act as pelmet for roller blinds on windows or for projector screen, etc. complete all as specified and directed
Preparing of new POP/ false ceiling surfaces and M&L for applying two coats royale luxury emulsion interior paint a luxurious smooth finish white or coloured over a coat of approved primer on walls or ceiling complete all as specified and as directed
Demolition of cement concrete in ground floor and paving not exceeding 15cm thick below or above ground level un re-inforced complete all as specified and directed. .
M&L for PCC 1:4:8 type D2 using (40mm graded stone aggregate) as in foundations, fillings & mass concrete etc complete all as specified and directed
M&L for cement concrete 1:2:4 type B2 (using 40mm graded stone aggretate) as in surface channel or drain complete all as specified and directed.
M&L for PCC (1:3:6) type C1 using 20mm graded stone aggregate in coping bed block etc including necessary form work complete all as specified and directed.
M&L PCC 1:2:4 type B2 using (40mm graded stone aggregate), 100mm thick as in flooring complete all as specified and directed
M & L PCC 1:3:6, type C2 (using 40 mm graded stone aggregate) 75 mm thick as in plinth protection without using extra cement complete all as specified and directed.
M&L for PCC of type D2, 1:4:8 using (40mm graded stone aggregate) 75 mm thick as in sub base complete all as specified and directed.
M&L PCC 1:2:4 type B1 using (20 mm graded aggregate) as in kerbing all around of tiles complete all as specified and directed.
Dismantling of stone slabs & tiles of any description or thickness in floor aprons, cills etc laid bedded & pointed in any mortar complete all as specified and directed.
M&L for Chequered cement concrete tiles 300mmx300mmx25mm thick set jointed and pointed in neat cement slurry in floors with in equal proportions & pigments with red and yellow colour over &including 20mm thick screed bed in CM 1:6 including dismantling of existing tiles of any description or thickness complete all as specified and directed
M&L 60 mm Machine pressed pre casted pressed cement concrete inter locking paver blocks with grey cement and pigment glazed coloured up to 6mm on the top in any shape and size, strenth not less than M-35 including dismantling of existing tiles of any description or thickness complete all as specified and directed
M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed
M&L Granite (of any type) work 20mm thick (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platform, verticle surfaces and any position over & including15 mm thick in cement mortar beddign in 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl chamfering and rounding of edges where required complete all as specified and directed
Demolition of pre-cast concrete block masonary built in cement mortar including all quoins, arches, pillars etc. and pre cast concrete articles complete all as specified and directed.
M&L for pre-cast cement concrete block masonry with solid blocks in 10cm in width in type B1 (1:2:4) and setting in mortar (1:6) complete all as specified and as directed
Taking down cement plaster on brick walls or stone walls etc including raking out joint, hacking for key, scrubbing down with water etc including removing debries directed for a distance max upto 500m complete all as specified and directed
M&L use for ready mix plaster for rendering 15mm thick on fair faces of brick/concrete surfaces in CM (1:4), finished even and smooth without using extra cement (WPC to be measured and paid separately) complete all as specfified and directed.
Preparation of new or previously untreated plastered surfaces of walls and M&L for applying two coats of acrylic antifungal paint exterior grade paint plain or camouflage pattern on one coat of primer complete all as specified and as directed
S&F Fire resistance BSEN 1634:1:2000 certified SS 304 grade satin finsh 1.5mm thick hollow pipe 'D' shape pull handle with 22-32 mm and c/c distance 450-600mm long including necessary fixing accessories of approved complete all as specified and directed
S&F stainless steel round and square bar, as in holdfast necessary welding and PCC 1:1.5:3 including admixture for fast settelment / strengthing of concrete followed by buffering and polishing for smooth finish complete all as specified and as directed.
S&F stainless steel round and square bar as in hinges with door/ gates necessary welding followed by buffering and polishing for smooth finish complete all as specified and as directed.
M/s S.D Construction Co
SREE HARITHA ASSOCIATES
INDIA ENGINEERS AND CONTRACTORS
Advait Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .