Loading…
Loading…
Tender ID
Tender Value
₹30.3 Cr
EMD Value
₹60.6 L
Closing Date
24 Mar 2026, 2:00 pmClosed
ADARSH KUMAR SINGLA
Hisar PHED No. 2
Upgradation of 2nd Existing Water Works Kheder Distt. Hisar providing sewerage network system providing sewerage network system
2026_HRY_505044_1
2026789CE7D0 B0B0 48FC 8EA5 9427E3903128565PUH
Open Tender
Civil Works
Works
730 days
KHEDAR KHEDAR KHEDAR
As per DNIT
3 documents required · 3 mandatory
₹20,000
₹60.6 L
Yes
13 Mar 2026
25 Feb 2026
24 Mar 2026
25 Feb 2026
24 Mar 2026
25 Feb 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: EE PHED-2 Hisar
DNIT Name :KHEDAR :DNIT for i) Upgradation of W/S Scheme in Village Khedar “Const. of 2.00 MLD WTP , Laying of 600 mm i/d RCC Np2 I/C, Repair of B/W.,Const. of 1 No. RCC SandS Tank 175x95x1.22 m.,Const. of 3 No.RCC CWT16x10x1.22 m. Each, Const. of 335 m.B/ W ,Dismentling of 120 m. B/Wall,Laying of Pipe Line , Rest. of Damaged H.H. Conn. and Prov. new water Connection ii) Prov. Sew. System “Const. of 2.50 MLD STP, MPS ,Const. of Staff Quarter 440 sft at STP and MPS , 98x98x3.05 m.,Laying of 350 mm i/d 20 mtr RCC NP3 Sludge Sump to Pond ,Laying of HDPE pipe 315 mm o/d 1750 m.,Laying of Sewer Line 200mm to 600mm, Const. of Brick Masonry Manhole, Inspection Chamber for 2 Houses connection including B/w,C.Conc. Path and Road, House hold Sewerage connection and restoration of street etc. Pumping Machinery, Electrical Panel, Specials of P/M ,OandM for 6 year as per letter issued by HEWP vide memo no. 11296-11352 PHE/HEWP dated 10/02/2026. and all other works contingent thereto
Contract No: 01662-246249
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description NS Item Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder in Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1.1 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately): 350 mm i/d Each Excess(+) Full Conversion INR
1.2 Less Credit of Old Bricks Nos. Excess(+) Full Conversion INR
1.3 Provision for constructed of SCADA based water purification plant of 2.00 MLD including Pumping machinery, filter bed, desktop, remote panels, raw water and clear water PLC, Electric panel for water works, starter for raw water pumping sets and clear water pumping sets, Electric panel for boosting stations including Instrumentation i.e Venturi flume - Ultrasonic type open channel flow meter, Range : 0-5 mtrs, Turbidity meter - Range : 0-500 NTU, Online pH meter - Range : 0-14 pH, Residual chlorine analyzer - Residual chlorine analyzer for chlorination system, Level Transmitter - Ultrasonic type level transmitter- Range: 0-8 mtrs, Output: 4-20 mAmps, Loss of Head Transmitter - Ultrasonic type level transmitter, Range : 0-5 mtrs, Output: 4-20 m Amps, Raw wate intake - Ultrasonic type level transmitter, Range - 0-5 mtrs, Output: 4-20 m Amps, Magnetic flow meter at outlet - Hard Rubber Liner, SS316L Electrode, Remode Electronics, 4-20 m Amps with local display with SCADA system complete in all respects and necessary provision for the same has been made in the estimate........... Job Excess(+) Full Conversion INR
1.4 `Supplying, erection, testing and commissioning of Horizontal centrifugal pumping set for clear water of reputed make i.e Compton, Greeves, Kirloskar etc. complete in all respects as per satisfaction of the Engineer in charge. `3500 LPM x 40 Mtr. Head (1W plus 1S).... Nos. Excess(+) Full Conversion INR
1.5 ANNEXURE BUILDING :- Construction of HT/LT Panel room, PLC room, Centrifuge house, blower room and Lab cum office building including doors, window and fitting with toilet block including sanitary fittings etc. as per drawing approved by SE at MPS and STP, 250 Sqm covered are built up with RCC framed structure and brick work finished with vitrified glaze tiles flooring, powder coated aluminum frame made with 10 gauge sheet heaving size 100 mm x 45 mm for chowkhat frame, 75mm x 45mm for door frame and 45mm x 45mm for window frame with 5mm thick glass AIS/Saint Gobain/Modi Float complete in all respects as per approved DNIT Sqm Excess(+) Full Conversion INR
1.6 CCTV CAMERAS :- Providing and Installing 6 CCTV Cameras ( 4 Cameras for STP, 2 Cameras for MPS) complete as per satisfaction of the Engineer- in- Charge, within 90 hours of signing the Agreement along with 90 days recording (DVR), 32 inch LED Screen, 16 Channel DVR at STP Site and 8 Channel DVR at MPS Site with connectors, cables, poles and power supply with online real- time output facility. The cameras at both the sites l.e. MPS and STP shall be synchronized at STP site complete in all respects as per approved NIT. At STP and MPS Site- 1 No. PTZ speed dome 360 degree 50 x zoom camera, 3 No. 12 mm lens size, 1 Nos. 3.6mm lens size. Make: - CP Plus Internet Protocol minimum 5 MP WDR, Night vision color mode 2.4.2 12 mm very focal with extra IR, CCTV Cameras should be installed and commissioned before starting of the work complete in all respect Job Excess(+) Full Conversion INR
1.7 MPS ( MAIN PUMPING STATION ) a) Design, construction, erection, testing and commissioning of MPS and following components: b) RCC Inlet chamber, screening chamber, collecting tank, wet well sump suitable for 2.50 MLD average flow with peak factor 3 including providing and installing 5 No. non clog sewage submersible pump set i.e. 1 No. of 5300 LPM, 2 No. 1800 LPM and 2 No of 900 LPM having minimum head of 20.00 m. equipped with suitable LT panel board, all safety devices automatic capacitor bank and suitable size submersible cable complete in all respect as per approved NIT. c) K9 DI pipes of suitable dia at MPS including welding and screwing of flanges, ISI marked DI fittings, sluice valves, non returning valves as per requirements even for bye-pass arrangements complete in all respects as per approved NIT. d) 3 No. Cl Gear operated sluice gate with SS spindle (SS 410) and seats (SS304) (2Nos. for screen and 1 No. for partition of collecting tank) as per design complete in all respect as per approved NIT. e) Supply and installation of 2 Nos. mechanical coarse screens suitable for 2.50 MLD average flow with peak factor of 3.0 complete in all respects as per approved NIT: f) All the infrastructure except construction of staff quarter, boundary wall and worked covered under schedule-1A ( HSR-items ) and path ways/roads required to be executed at site to make the MPS functional is included in the scope of work for lump-sump job complete in all respects as per approved NIT. g) All the pumping machinery, panel board, Level sensor etc. shall be controlled by PLC and SCADA and shall be synchronized with PLC panels at MPS and STP site through broadband internet facility. h) The size and quantities of all the above components will be as per approved structural/ Hydraulic/ Mechanical/ Electrical design to be approved by department before actual execution of work complete in all respects as per approved NIT Job Excess(+) Full Conversion INR
1.8 Providing and fixing Cast Iron Detachable Joints class-25 marked with IS: 8794 for use with asbestos cement pressure pipes complete with 2 Nos. rubber rings marked with IS:5382 and IS:10292 and appropriate number of nut and bolts marked with IS:1363 including carriage, loading, unloading etc. complete in all respects to the satisfaction of the engineer-in-charge. (Excavation will be paid separately) 350mm i/d CID Joints Each Excess(+) Full Conversion INR
1.9 SEWAGE TREATMENT PLANT A ) SEWAGE TREATMENT PLANT a) Design, construction, erection, testing and commissioning of 2.50 MLD capacity Sewage Treatment Plant based on Sequential Batch Reactor (SBR) Technology complete in all respect including landscaping, MCC Panel room, all other contingent i.e. Electrical, Mechanical, piping and Instrumentation work with PLC and SCADA arrangement for STP integrated with MPS including furniture and laboratory equipments as per detail given in the bid document and following components complete in all respects as per approved NIT. b) Supply and installation of 2 Nos. fine screens of suitable size for 2.50 MLD average flow with peak factor of 3.0 complete in all respects as per approved NIT. c) 2 Nos. High Mast of 9 mtr. Gl octagonal pole of 4 mm thickness (T=100mm, B=200mm, Base plate= 320x320x20mm), window at 500 mm from base plate with 6 No LED suitable size, outdoor type energy, efficiency lamps on each pole, 20 No. LED outdoor light with 7m. high GI pole along Road/path including all accessories complete in all respects as per approved NIT. d) Supply and installation of 1 No. 3.65 m wide main gate of MS and 1.25 m wide wicket gate at STP to the entire satisfaction of Engineer-in-charge (Total weight not less than 500kg) complete in all respects as per approved NIT. Providing and installing 2 Nos. centrifuges (1Working plus 1 Stand bye) including centrifuge feed pump all fittings, instrumentations, electric panel board etc. as per design including packing dry sludge in 20 Kg. bag and supplying the same in market Kisan Sewa Kendra or as directed by Engineer- in charge within the lead as pointed at clause 4.4.4 of the DNIT, complete in all respects as per approved NIT. B) ONLINE OUTLET EFFLUENT WATER QUALITY MONITORING SYSTEM b) Supply, installation, testing and commissioning, operation and comprehensive annual maintenance of effluent quality monitoring system at 2.50 MLD STP at KHEDAR for online (Continuous) measurement of PH, Total Suspended Solids (TSS), Chemical Oxygen Demand (COD), Biological Oxygen Demand (BOD) by single analyzer with various sensors (spectral measurement in the UV-VIS range 200-720mm) performing reagent and chemical free analysis with automatic cleaning of censor, signal cables and power cables, local data acquisition and display of data on continuous basis for up linking the data to CPCB, HSPCB and PHED. TUV approved complete in all respect as per Central Pollution Control Board (CPCB) guidelines for online continuous monitoring system for effluent and as contained in scope of work in the DNIT complete in all respects as per approved NIT. a) Multi-parameter measuring converter, for connecting upto 18 intelligent sensors Scope including 8 analog inputs/Outputs (4 inputs and 4 outputs) (o/4-20 Ma), wide range power supply optical COD/BOD and TSS probe with spectral processing of the UV-VIS range for measurement in the outlet/ effluent of plant of 2.50 MLD capacity STP at village KHEDAR with integrated with automatic cleaning complete in all respects as per approved NIT. b) Robust digital pH/ ORP sensor for pH/ORP electrodes, with built-in pre-amplifier and temperature sensor with Automatic Temperature compensation (ATC) cable length 100 Meter (minimum) complete in all respects as per approved NIT. c) Sensor adapter cable for all intelligent sensors, with IP68 water proof connection to intelligent sensors net system cable length 100 Meter (minimum) complete in all respects as per approved NIT. d) Data Transfer to CPCB, HSPCB and PHED Servers complete in all respects as per approved NIT. e) Providing GSM, 3G, 4G, 5G Modem with mobile network connectivity including network complete in all respects as per approved NIT… Job Excess(+) Full Conversion INR
2.1 Less Credit of old Brick Bats Cum Excess(+) Full Conversion INR
2.2 Credit of old clear water pumping machinery of size 3000LPM X 40M HEAD (45 BHP) Nos. Excess(+) Full Conversion INR
2.3 Operation and maintenance of 1 No. water treatment plant 2.00 MLD capacity (At 2nd water works) proposed STP of 2.50 capacity proposed MPS, laying of sewer line, mainholes, inspection chamber for 6 year Defect liability cum maintenance period (after 3month trial run) as per letter issued by the project director HEWP vide memo no. 11296-11352 PHE/HEWP dated 10/02/2026. (Operation and maintenance will be charged to the A/mtc. Estimate) complete in all respect as per approved NIT. Job Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Select, At Par, Excess (+), Less (-) IOCL
Tender Inviting Authority: EE PHED-2 Hisar
DNIT Name :KHEDAR :DNIT for i) Upgradation of W/S Scheme in Village Khedar “Const. of 2.00 MLD WTP , Laying of 600 mm i/d RCC Np2 I/C, Repair of B/W.,Const. of 1 No. RCC SandS Tank 175x95x1.22 m.,Const. of 3 No.RCC CWT16x10x1.22 m. Each, Const. of 335 m.B/ W ,Dismentling of 120 m. B/Wall,Laying of Pipe Line , Rest. of Damaged H.H. Conn. and Prov. new water Connection ii) Prov. Sew. System “Const. of 2.50 MLD STP, MPS ,Const. of Staff Quarter 440 sft at STP and MPS , 98x98x3.05 m.,Laying of 350 mm i/d 20 mtr RCC NP3 Sludge Sump to Pond ,Laying of HDPE pipe 315 mm o/d 1750 m.,Laying of Sewer Line 200mm to 600mm, Const. of Brick Masonry Manhole, Inspection Chamber for 2 Houses connection including B/w,C.Conc. Path and Road, House hold Sewerage connection and restoration of street etc. Pumping Machinery, Electrical Panel, Specials of P/M ,OandM for 6 year as per letter issued by HEWP vide memo no. 11296-11352 PHE/HEWP dated 10/02/2026. and all other works contingent thereto
Contract No: 01662-246249
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1 Item Description BI01010001010000000000000515BI0100001112
1.01 HSR Items for DNIT Name :KHEDAR :DNIT for i) Upgradation of W/S Scheme in Village Khedar “Const. of 2.00 MLD WTP , Laying of 600 mm i/d RCC Np2 I/C, Repair of B/W.,Const. of 1 No. RCC SandS Tank 175x95x1.22 m.,Const. of 3 No.RCC CWT16x10x1.22 m. Each, Const. of 335 m.B/ W ,Dismentling of 120 m. B/Wall,Laying of Pipe Line , Rest. of Damaged H.H. Conn. and Prov. new water Connection ii) Prov. Sew. System “Const. of 2.50 MLD STP, MPS ,Const. of Staff Quarter 440 sft at STP and MPS , 98x98x3.05 m.,Laying of 350 mm i/d 20 mtr RCC NP3 Sludge Sump to Pond ,Laying of HDPE pipe 315 mm o/d 1750 m.,Laying of Sewer Line 200mm to 600mm, Const. of Brick Masonry Manhole, Inspection Chamber for 2 Houses connection including B/w,C.Conc. Path and Road, House hold Sewerage connection and restoration of street etc. Pumping Machinery, Electrical Panel, Specials of P/M ,OandM for 6 year as per letter issued by HEWP vide memo no. 11296-11352 PHE/HEWP dated 10/02/2026. and all other works contingent thereto BI01010001010000000000000515BI0100001113 Nos 207477903 Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.70 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.98 MB
BOQ_583769.xls
BOQ • 0.28 MB
1F4BOQZ137661.pdf
Additional Documents • 6.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .