AE_KCESD_II
OFFICE OF THE ASSISTANT ENGINEER Kolkata Central Electrical Sub Division II PWDte
SITC of one number 05 persons capacity 340 Kg load passenger lift at Bangiya Sahitya Parishad 243/1 Acharya Prafulla Chandra Road Kolkata 700006 Electrical Installation work
2026_WBPWD_5016483_1
WBPWD/AE/21/Q/KCESD/II of 2026-27
Open Tender
ELECTRICAL WORKS M/R
Item Rate
7 days
Bangiya Sahitya Parishad
SITC of one number 05 persons capacity 340 Kg load passenger lift at Bangiya Sahitya Parishad 243/1 Acharya Prafulla Chandra Road Kolkata 700006 Electrical Installation work
4 documents required · 4 mandatory
₹4,809
Office of the AE_KCESD_II
19 Aug 2026
8 Jul 2026
24 Aug 2026
8 Jul 2026
22 Aug 2026
14 Jul 2026
14 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling the existing damaged wiring , cables, switch and depositing the same to the concerned authority, including mending good damages neatly. ( Wiring with necessary arrangements-300 mtr. 4 core 50 sqmm cable-50 mtr , 4 core 35 sqmm cable-50 mtr,100A TPNSFU-1 nos ).One new existing 6 way VTPNMCBDB and 4 way HTPNMCBDB at lift place is to be shifted after dismantling the existing connection and refixing of the same from 5 mtr distance of the existing location including necessary connection. Existing newly laid 4 core 70 sqmm cable which feed the power to the 6 way VTPNMCBDB will be removed from the existing location and then reconnected to the VTPNMCBDB. (Considering 1 Skilled, 02 nos Semi-Skilled & 2 Nos Unskilled) | 1 | Job | - | - |
| 2 | Supply & Delivery of 1.1KV grade 4 core 16 sqmm XLPE insulated Aluminium Ar. cable ( Make -Gloster/ RR cable/ Havells/ polycab) (From existing light Panel 63A MCCB to RCCB incoming power connection for lift) | 140 | mtr | - | - |
| 3 | Laying of 4 core 16 sqmm cable on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting. | 140 | mtr | - | - |
| 4 | S & F compression type brass cable gland complete with brass gland, brass ring & rubber ring for dust & moisture proof entry of XLPE/PVC armoured cable.incl.finising the end as follows a.) 4 core 16 sq. mm. | 2 | Each | - | - |
| 5 | Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment (Legrand ) 4 Way | 1 | nos | - | - |
| 6 | Supplying and fixing of 40A 300mA FP RCCB (Legrand 411887) in existing four pole SS enclosure including necessary connection and earthing attachment. | 1 | nos | - | - |
| 7 | Supplying and fixing double-door(2+8 way) SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make -Legrand/Schneider/ABB)
Incoming - DP MCB Isolator 40A -1.
Outgoing 6 A -32 A SPMCB-8 nos | 1 | nos | - | - |
| 8 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works.
(a) 20 mm size. | 60 | RM | - | - |
| 9 | Supply and fixing of 19 mm dia. 1.6mm thick GI conduit (ISI medium)(inner surface should be smooth) complete with fittings such as necessary bends, tees, inspection box, circular box saddles etc. as necessary on ceiling/beam/wall bound with 22SWG G.I. binding wire including supplying and drawing 1X18 SWG G.I. wire as fish wire inside the pipe having colour paint at one face fastened at the load point end of the G.I. pipe with fish wire on ceiling . for passing copper wires. | 475 | mtr | - | - |
| 10 | Wiring with 1.1 KV grade single core PVC insulated stranded Copper wire in GI
conduit and painting Wiring with 1.1 KV grade single core PVC insulated stranded Copper wire in GI conduit and painting
3x1.5 sqmm wire in 19 mm conduit incl. S&F 2x10 SWG GI ECC | 40 | mtr | - | - |
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.66 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.46 MB
BOQ_5086008.xls
BOQ • 0.35 MB
2911.pdf
Tender Documents • 0.51 MB
DC4.pdf
PDF • 0.66 MB
DC3.pdf
PDF • 0.66 MB
DC2.pdf
PDF • 0.66 MB
DC21.pdf
PDF • 0.66 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .