Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹16.5 L+₹1.1 L (7.18%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
29 Jan 2021, 6:00 pmClosed
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
REPAIR TO CULVERT, DRAINS, SECURITY FENCING, GATE, PATH/ HARDSTANDING AND ALLIED WORKS IN K NALLAH, SURANKOTE AREA UNDER STN HQ KG UNDER GE 881 EWS
2020_MES_406679_1
GE/PNH-68/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹28,000
Yes
17 Feb 2021
24 Dec 2020
30 Jan 2021
24 Dec 2020
29 Jan 2021
7 Jan 2021
Amount
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion in concrete, brick work, masonry etc and making good disturbed ground, complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion in natural ground and making good disturbed ground and preparing post holes for providing new posts in any type of soil complete all as specified and directed.
Taking down carefully old galvanised stranded steel barbed of any description from old RCC or steel pole (each line wire to be measured) and removing frim site, complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically described (reinforement cut as required to facilitate demolition), complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and directed.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
Taking down cement plaster of any description on stone or brick walls etc including racking out joints, hacking for key scrubbing down with water etc.complete all as specified and directed.
Excavation in post holes each not exceeding 0.5 cum getting out in any type of soil, returning, filling in, including spreading, leveling, watering and well ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface, complete all as specified and directed.
M&L for Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations filling and mass concrete, complete all as specified and directed.
M&L for Mild steel work as in posts and struts in fencing including cuttings, tops to shapes, as directed, drilling, holes, notching for wire etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. fixed and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F Galvanised, 2 strand steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including securing and tying at crossings with and provision of galvanized (zinc coating 60 gram) mild steel wire, staple or steel pins, etc complete all as specified and directed.
Supply only Chain link MS galvanisd (zinc coating 60gram) fencing, any size or type, complete all as specified and directed. Note:-Type / size of fencing holes / dia of chain link fenching shall be as approved by GE. The weight of chain link fencing shall be calculated for payment as per actual weight or standard weight as per SSR which ever is less.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire, complete all as specified and directed.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation etc for shafts, wells,cesspits, man holes, pier holes etc not exceeding 10 sqm on plan and not exceeding 1.5m depth and getting out in any type of soil, complete all as specified and directed.
Returning, filling in surplus spoil including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) type B-1, 1:2:4 (20 mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc and in similar works, complete all as specified and directed.
M&L for RCC (nominal mix) type B-1 (1:2:4) using 20mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts, complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter to be rough finished surfaces of concrete complete all as specified and directed.
Form work to sides of pillars, posts, struts piers, columns and stanchions and similar worksfor rough finished surface of concrete complete all as specified & directed.
S&F TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified and directed.
M&L for TMT bars, 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia, complete all as specified and directed.
M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups spaces and binders cut to length bent to shape and binding with MS wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for Mild steel screw bolts 16-20mm dia at neck, machine made, with hexagonal or square heads at one end and screwed the other, or screwed both ends; each screwed and to be fitted with washers and one hexagonal or square nut, length of bolt exc 15cm and n exc 22.5cm long, complete all as specified and directed.
S&F Concertina coil fencing with punched tape made to shape as directed having dia exc 450mm but nexc 600mm put on top of wall in between angle iron Y shaped post and secure with necessary binding wire complete all as specified and directed.
M&L for Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius, built in cement mortar (1:6), complete all as specified and directed.
M&L for Walling of random rubble stone masonry brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and directed.
All all as per item No.28 above, but except stone complete all as specified and directed
M&L for Boulder filling hand packed tightly (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level, complete all as specified and directed.
M&L for Rendering 20mm thick on other than fair faces of brick or stone masonry wall surfaces in cement mortar 1:4 and finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 15mm thick cement plaster rendering in CM 1:4 on fair faces of bricks or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:6 on other than fair faces of brick or stone masonry wall surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Raking out joints / pointing to random rubble or polygonal rubble uncoursed or brought up to courses build in cement mortar, complete all as specified and directed.
M&L for Raised pointing to random rubble masonary, or polygonal rubble, uncoursed or brought upto courses in cement mortar 1:4, complete all as specified and directed.
M&L for Applying three coats of white wash including preparation of newly plastered surfaces of wall complete all as specified and directed.
M&L for Preparation of newly plastered or unplastered surfaces of wall and applying two coats of cement base paint, complete all as specified and directed.
S&F Mild steel work conforming to Fe-290 (Gde E-165) as in grills, gratings etc. with ends of bars shouldered and/ or rivetted or forged into spikes; framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works, complete all as specified and directed.
M&L for Applying two coats of synthetic enamel paint of Ist quality over a coat of red oxide primer to new or previously untreated steel surfaces over 10cm width or girth including preparation of surfaces, complete all as specified and as directed.
M&L for Pre-cast cement concrete block masonry 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) with solid blocks, exc. 10cm in width and setting in cement mortar 1:4, complete all as specified and directed.
M&L for Plain cement concrete 1:3:6 type C-1(using 20mm graded crushed stone aggregate) as in surface channels and drains, complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopper ends etc complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base floor finishing surface even and fair, complete all as specified and directed.
M&L for Chequered cement concrete tiles 300x300x 25mm thick, set & jointed in neat cement slurry in floors and pointed with equal proportion of white and grey cement and no pigments, laid over and including 20mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for RCC (nominal mix) 1:2:4, type, B-1 (using 20mm graded crushed stone aggregate), as in slab supported on walls, columns in floors, roofs, landings, balconies and in shelves, complete all as specified and directed.
Form work to soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for rough finished surfaces of concrete, complete all as specified and directed.
M&L for PCC 1:2:4, type, B-1 (using 20mm graded crushed stone aggregate), as in coping, plinth band, bed block PCC blocks for hold fast including rounded or chamfered angle as directed including necessary form work etc., complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring/path etc, complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block (reflective type) any shape and size confirming to IS-15658-2006 of 60mm thickness M-35 grade, laid jointed & pointed with grey cement and pigments, complete all as specified and directed by Engr-in-Charge.
Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed
PVC (SWR) pipes 110mm dia any length single socketed as in weep holes, laid in trenches/floors, complete all as specified and directed.
Precast cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregates) as in bond stones walling, bed plates, anchorage blocks etc and set in cement mortar 1:6, complete all as specified and as directed.
S&F Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M/S KEWAL KRISHAN SANJEEV KUMAR VAID
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .