| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹38.0 L+₹2.1 L (5.84%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹38.7 L+₹2.8 L (7.66%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹38.9 L+₹3.0 L (8.36%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹42.5 L
EMD Value
₹85,000
Closing Date
13 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Bharatpur
GE Kanjoli line Bharatpur-321026
Spl repair to Bldg No P-76 and P-77 at Sewar fort in Bharatpur Mil Stn
2024_MES_666817_1
8403/E8
Open Tender
Civil Works
Item Rate
180 days
GE Bharatpur
As per NIT
7 documents required · 7 mandatory
₹500
GE Bharatpur
₹85,000
Yes
16 Oct 2024
24 Jul 2024
16 Sept 2024
24 Jul 2024
13 Sept 2024
7 Aug 2024
25 Jul 2024 - 6 Aug 2024
Amount
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Dismantling of timber scantling 40 Sqcm and over in section in any position as in unframed work complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
Demolition of brick work or stone/boulder masonary, built in cement mortar including all quoins,arches,pillars,etc. complete all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortor bedding (but not backing) removing the rubbish outside MD land complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
Taking up or down 25mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
Taking down chowkats or frames (without taking of shutter from the frame) exc. 1.5 Sqm each and not exc 4 Sqm each complete all as specified and directed.
Taking down Shutters of any description exc 2 sq. m each each complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
S & F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws and including valleys and gutters complete all as specified and directed.
M & L for rolled mild steel work in roof trusses (framed )purlins crane gantries , rafts and fastening and heavy brackets framming including cutting to ded length required drilling fitting welding or connecting with nut bold providing and fittings (beams tee,angle channel and or flat sections) etc quality confirming to Fe-290 (Gde-E-165). complete all as specified and directed.
S&F for Anodised aluminium snap grid frame work for false ceiling, 605 x 605 mm in size complete all as specified and directed.
S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed
S&F Fibre insulation boards, ordinary type complete all as specified and directed.
M&L Brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L for Walling of random rubble, uncoursed as in uncoursed, well bonded, bedded and solidly hearted built in CM 1:6 complete all as specified and directed.
M&L for Raised pointing to random or polygonal rubble, uncoursed or brought upto courses in CM 1:3 complete all as specified and directed.
M&L for PCC in 1:4:8 type D2 (using 40mm graded agg) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for PCC 100mm thick in 1:2:4 type B2 (using 40mm graded agg) as in flooring, complete all as specified and directed.
M&L Cement concrete type C-2 1:3:6 (using 40mm graded crushed stone aggregates) as in 75 mm thick plinth protection , finished surfaces even and smooth without using extra cement, complete all as specified and directed.
M&Lfor Non skid coloured tiles 7 to 8 mm thick square /rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match incl screed bed 15mm thick in CM (1:6) complete all as specified and directed.
S&F for Glazed ceramic coloured tiles in vertical surface 450 x 300 mm 7-8 mm thick white set and jointed in neat cement slurry and pointed in white cement to match incl 10mm thick rendering in cm 1 :4 as backing coat, even and fair to receive tiles etc all as specified and as directed
S&F 15mm bore Tubes,'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 20mm bore Tubes,'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 25mm bore Tubes,'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
S&F in repair solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specifications & drawings complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawingspecification and drawing complete all as specified and as directed
S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
M&L in repair for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for preparation new or previously untreated steel surfaces of any description not otherwise described exceeding 10 cm width or girth and applying two coat of synthetic enameled paint over a coat of red oxide incl. cleaning glass,joinery etc. of drop & splashes complete all as specified and directed.
S&F 100mm size butt hinges medium weight cold rolled mild steel and fixed (ISI Marked) complete all as specified and directed.
S&F 150mm long aluminium handles, cast type, anodised complete all as specified and directed.
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed
S&F 125mm size butt hinges heavy weight cold rolled mild steel and fixed (ISI Marked) complete all as specified and as directed
S&F 300 mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
S&F 150mm long Cast iron or malleable cast iron handles, cast type, stove enamelled black complete all as specified and directed.
Factory made steel window with side hung shutteers including projecting type hinges with steel handle and steel peg stay complete with glazing bars dovetailed or welded (Note :- Mild steel wire cloth shall be measured and paid separately under respective items) complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges,steel peg stay, handle complete all as specified and directed.
S&F Mild steel semi barrel tower bolt, riveted or spot welded type with back plates, with bright bolt and open staple, and fixed complete all as specified and directed.
S&F 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.
M&L for 10mm thick rendering on fair faces brick work or concrete surfaces in cement mortar 1:6 finished surfaces even and smooth (without using extra cement) complete all as specified and directed.
M&L for rendering in two layers (i.e) CM 1:6, 10mm thick as first layers and CM 1:4, 5mm thick as 2nd layer wtih water proofing compund on stone masonry surfaces or surfaces other than fair face of brick or on concrete surfaces finished even and smooth without using extra cement complete all as specified
M&L for preparation of newly plastered or unplastered surfaces of walls and applying three coats of white wash on walls upto 4th floor including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premises clean and tidy complete all as specified and directed.
M&L for preparation of newly plastered or unplastered surfaces of walls and applying two coats of cement base paint on walls upto 4th floor including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premises clean and tidy complete all as specified and directed
M&L for preparation of old decorated surfaces plastered or unplastered on walls including cornices , pilasters by brooming down or steel wire brushing , scraping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of white wash on walls upto 4th floor including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premises clean and tidy complete all as specified and directed
M&L for preparation of old plastered or unplastered surfaces of walls including cornices , pilasters by brooming down or steel wire brushing , scraping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy/spots and applying one coat of Cement Base Paint on walls upto 4th floor including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premises clean and tidy complete all as specified and directed.
S&F in repairs vitreous china squatting pan water closet ‘orrisa’ pan size 580x440mm incl. Integral foot rest including cement concrete bedding etc complete all as specified complete all as specified and dircted
S&F in repair bib cock with wall flange,cast copper alloy, fancy type chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm dia of pipe complete all as specified and dircted
S&F in repairs Angular stop cock with adjustable wall flange, cast coper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions, and fixed for bore 15mm bore of pipe complete all as specified and dircted
S&F in repair Vitreous China wash basin, wliile, flat back, size 580x450irun (for Hospilal use) including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed.
S&F in repairs pillar taps, fancy type, with capstan heads, chromium plated, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shank and fly-nut, screws for iron pipe and fixed for 15mm dia of pipe complete all as specified and directed.
Supply & fixing in repair PVC valve less Symphonic action type L flushing cistern, 10 Litre Capacity,white with inlet,ball valve, float and handle incl bracket in repair complete all as specified and directed.
S & F in Repairs Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern incl fixing with fushing cistern complete all as specified and directed.
S&F in repair PVC connection 15mm dia with PTMT nut of length 450mm long complete all as specified and directed.
Supply & fixing in repair cast iron nahani trap 75mm outlet dia with grating including jointing to waste pipe fixed in cement concrete type B-1(1:2:4) complete all as specified and directed.
S&F in repair grating doom 100mm dia of PTMT (Minimum weight 25 gms) in repairs complete all as specified and directed.
S & F in repair Ball valves 25 mm bore high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball screwed for iron pipe & fixed.(Minimum weight15mm-142gms / 20mm-210gms / 25mm-455gms / 40mm-690gms) complete all as specified and directed.
S & F in repair Nipple suitable for HDPE water tank 25 mm bore . (mimimum weight 15mm-38gms / 20mm-45gms / 25mm-65gms) complete all as specified and directed.
S & F in repair 25 mm bore Gun-metal, glabe or gate valves, with iron wheel head, screwed both ends for iron pipe & fixed complete all as specified and directed.
S & F in repair 20 mm bore Gun-metal, glabe or gate valves, with iron wheel head, screwed both ends for iron pipe & fixed complete all as specified and directed.
S&F in repair Soap dish, any type, fixed to plugs with chromium plated brass screws in the wall complete all as specified and directed.
S&F in repair Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and dircted
S&F Rotational moulded polyethylene water storage tanks 500 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including Dismantling water tanks and removing to store complete all as specified and dircted
M&L 75mm thick PCC type C-2 1:3:6 (using 40mm graded stone aggregate) as in sub base, complete all as specified and as directed.
M&L for 60mm thick Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 M-35 Grade with no grey cement & pigment complete all as specified and directed.
M&L for sand cussioning under the interlocking tiles complete all as specified and as directed.
M&LSealing of cracks by applying two coats of Hydroseal IPN Resin & Hardener or equvalent in the grooves with spray gun or suitable brush in proportion of 1.0 Resin (I.P.N) :1 Hardner (I.P.N) by weight. and filling the cracks with the Hydroseal putty in the proportion of 1.0 Resin (I.P.N) :1.0 Hardener (I.P.N) : 4.0 Admixture Q.S. by weight and applying top coat of Hydroseal IPN Resin & Hardner in proportion of 1.0 Resin (I.P.N) :1 Hardner (I.P.N) by weight complete all as per manufacture's instructions complete all as specified and directed.
M&L Pressure shortcreting 25mm thick in cement concrete 1: 1: 2 (Nominal mix) including necessary scaffolding to all affected area of RCC structure/brick work/stone masonry work up to 18.75 m height complete including scaffolding as required complete all as specified and directed.
M&L Drilling 16mm dia holes in old concrete/brick/stone work upto depth not less than 150mm cleaning the holes by blower and injecting grouting chemical of make-HILTI or equvalent product HY-150 or equivalent into the holes all as per manufactures instructions complete all as specified and directed.
Excavating in trenches n exc 1.5 m wide and n exc 1.5m in depth, for foundation, etc and getting out in soft/loose soil complete all as specified and directed.
Removing excavated material to a distance n.exc 50m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed.
Returning , filling in, incl spreading leveling, watering and well ramming in layers n.exc 25cm in soil complete all as specified and directed.
M & L for cement concrete 1:4:8 type D 2 using 40 mm .graded aggregate in foundation complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, built in cement or cement lime mortar including all quoins, arches, pillars, etc, but exceeding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M/L brick work with sub class B brick straight or curved on plan exc. 6 M mean radius built in cement mortar 1:6 complete all as specified and directed.
S&F in repair 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/floor complete all as specified and directed.
S&F in repair 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/floor all as complete all as specified and directed.
S&F 110 mm dia PVC (SWR) bends any length any type complete all as specified and directed.
S&F 75 mm dia PVC (SWR) bends any length any type complete all as specified and directed.
S&F 110mm PVC (SWR) branch piece double (double Y) equal or unequl complete all as specified and directed.
S&F 100mm Cowls (with 3 stays), riveted to and including 15 cm length of flue pipes complete all as specified and directed.
M&L for providing precast reinforced cement concrete of type B1 (1:2:4) (using 20 mm graded stone aggregate) as in covers for drain set in cement mortar (1:4) complete all as specified and directed.
M&L for TMT bars 10mm dia and over cut to length bent to shape required incl cranking, bending spirally for hoping for colums, or ren work, hooping ends and binding with and incl mild steel wire annealed, not less than 0.9mm dia complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, bell,socket or power) complete fittings such as switches, ceiling roses, pendents, holders,regulators, sockets etc removing materials for taking credit and making good disturbed surfaces of wall, floor & ceiling etc.
Dismantling of old U/S sub main wiring and service wire of any size & make.
Dismantlingof old U/S rusted main switch/DB of any size capacity and make.
M&L point wiring complete with 1.5 Sqmm 02 x single core multistranded copper conductor of 1100 volts grade PVC pre insulated FRLS and unsheathed cable enclosed in rigid PVC conduit pipe size not less than 20mm dia with all PVC accessories such as Tee, bend, collar, elbow, square junction box etc fixed on the concealed surface of wall/ceiling by means of PVCsleevel/dash fastners with cadmium plated screws including suitable size SS / MS shunken/metal flush box for mounting of flush type/modular fittings like switches, sockets, fan regulator etc including 1.5 Sqmm PVC insulated but unsheathed copper earth continuity conductor (in green color) to common earth and connedcted to earth dolly complete all as specified and directed for the following :-
One light point controlled by one way switch.
One ceiling fan/wall fan/exhaust fan point controlled by one way switch.
One 3 pin 6 Amp socket point outlet on the same board with other switches
One 3 pin 6 Amp socket point outlet on the independent board
All as per item No 93 above but with multi stranded copper conductor cable 2.5 Sqmm size for 3 pin 16 Amps switch socket outlet on independent board including 2.5 Sqmm copper cable PVC insulated FRLS unsheathed copper continuous earth wire including connecting to common earth dolly.
S&F ceiling rose surface bakelite three terminal ISI marked including suitable size of PVC board .
S&F switch piano flush button single pole one way 6 Amps 230 volt grade.
S&F modular type Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type multi purpose flush type 230 volt
S&F modular type switch, 15 Amp flush type, complete all as specified and directed.
S&F modular socket 3 pin 15/16 Amps flush type, complete all as specified and directed.
S & F Lamp holder, PVC/polycarbonate type with cord grip cap suitable for pendant fitings all as specified and directed.
S&F modular type electronic fan regulator EME type 450 watt .
M&L submain wiring complete with 2X 4 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor and one run of 4 Sqmm copper cable for earth continuity conductor and including rigid PVC conduit with all PVC accessories fixed on concealed surface complete.
Distribution board factory made and tested made of sheet metal enclosure powder coated suitable for mounting the MCB 240 volt of the following DBs in
4 way TPN with 200 amps rated busbar 415 volts (double door type).
8 way SPN with 200 amps rated busbar 240 volts (double door type).
S&F MCCB/MCB 415/240 volts fixed in DB's of the undermentioned type and rating. Note: Make of MCCB/MCB should be same of DB.
MCB TPN 63 Amps, 415 volts,Category- C curve, 10kA rapturing capacity ( ISI marked IS-8828)
MCB SP 6-32 Amps, 240 volts,Category- C curve, 10kA rapturing capacity ( ISI marked IS-8828)
MCB SPN 40 Amps, 240 volt,Category- C curve, 10kA rapturing capacity ( ISI marked IS-8828)
Supply and fixing in repair LED 20 watt LED tubelight fitting retro fit type 4 feet long with replacable rod complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V, 50 Hz, complete all as specified and directed.
S & F street light GI bracket of 0.6 mtr long made out of 40mm dia light grade GI pipe bend to shape of 120 degree end welded at required including 02 Nos MS clamp of FL 40 x 6mm including nuts bolts & washers complete necessary fixing arrangements on pole as directed.
Supply & fix 35/36 watts LED street light fitings new generation energy saving ,environmental friendly ,long life,versatile pressure die cast aluminium IP66 with 10KV surge protection road way,luminaire with high power LED as light source and suitable drivers etc and connecting with 2 x 1 sq mm multistranded PVC insulated copper conductor from fittings to the ceiling rose and fixing to complete all as specified and directed.
S&F exhaust fan of 250 mm sweep 900 rpm with suitable size of louvers , connecting wire PVC insulated twisted flexible 0.5 sqmm copper conductor including all standard accessories complete all as specified and as directed by Engineer -in-charge
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame & louvers , connecting wire PVC insulated twisted flexible 0.5 sqmm copper conductor including all standard accessories complete all as specified and as directed by Engineer -in-charge
Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm buried directly in the ground vertically to depth not less than 3 Mtr below the ground level with the top edge of earth plate, depth not less than 2.25 Mtr below the ground level connected to connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts and washers protected by GI tubing light grade 40 mm dia uptoTest point 20 mm dia watering pipe with funel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates chamber 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and shown in electrical plate No.3 of SSR Part-I including earth work in any type of soil ,removal of surplus sil and providing charcol dust & salt layers all around the earth plate upto 15 cm all as required specified & directed by engr in charge ( Note:- Up to 7.5 Mtr length of pipe of 40 mm dia and GI wire shall be deemed to be included in unit rate quoted by tenderer GI pipe and GI wire beyond 7.5) will be measured separately under respective item.
Excavation in trenches, n. exc 1.5 Mtr wide and n. exc 1.5 Mtr in depth for foundation/laying of cable and getting out in soft/loose soil.
Removing of excavated soil to a distance n. Exc 50 Mtr and depositing where directed at a level n. Exc 1.5 Mtr above the starting point
Returning, filling in including spreading, levelling, watering and well ramming in layers n. Exc 25 cm thick.
Supply & laying 20mm GI pipe medium grade with all fittings laid in trenches in old/new position as directed . Note: Item rate to be quoted include the rate of connection to main DI pipe line with clamp & fittings.
Supplying & fixing gun metal gate valves with iron wheel head,screwed both ends for iron pipe, ISI Marked, as per IS: 778 of 20 mm bore complete all as specified and as directed .
Demolition of Concrete in ground floors and pavings not exc 15cm thick( below or above ground floors) complete all as specified and as directed.
M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm. Note : Punned thickness shall be measured
Supply and laying of sub class 'B' bricks in trenches over cables for protection cover across the length of cable complete all as specified and directed.
M&L for driling hole in hard standing / road for laying of pipe for protection of cable etc by adopting method of horizontal manual drilling (trenchless technology) without disturbing the top surface or cutting and making good the disturbed surface to the existing surface.
Supply and laying in replacement of GI tube light grade 40 mm bore complete.
Supply laying testing and comminssioning of XLPE insulated LT U/G cable heavy duty , 1100 volts grade armoured and PVC sheathed with multistranded aluminium conductor 35 Sqmm 3.5 core sizes in trenches /passing through pipes/ on poles etc complele all as specified and directed.
B R ENTERPRISES (BID ID -3095043)
M/s Ranaji Construction Co (BID ID -3090794)
Tulsi Enterprises (BID ID -3088966)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .