Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
8 Feb 2021, 11:30 amClosed
SO1 (Works )
ARTC and School 3 rd mile, Dimapur
REPAIR/MAINT OF DISTRIBUTION NETWORK OF EXTG 500 KVA TRANSFORMER INSTALLED AT ARCH AND REPLACMENT OF GENR WIRING AT SHOKHUVI
2021_ARMHA_612021_1
ARTC/DGAR/SKV/66 of 2020-21
Open Tender
Electrical Works
Works
ARTC and School 3rd mile dimapur
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
FCI Aravali Gypsum and Minerals India Limited
Exempted
1 Mar 2021
25 Jan 2021
9 Feb 2021
25 Jan 2021
8 Feb 2021
25 Jan 2021
25 Jan 2021 - 8 Feb 2021
Amount
REPAIR/MAINT WORKS
Supply, installation, testing & commissioning of factory made cubical flour mounted outdoor distribution feeder pillar box with built-in APFC 100 KVAR for 500 KVA transformer , totally enclosed dust and vermin proof, front side opening with locking arrangement made of angle iron frame work of size 50mmx 50mmx6mm thick and 2.00 mm thick MS sheet duly powder coated , suitable for 800 amp capacity aluminum bus bar , size of the panel board should be not less than 2250 (W)x1600(W) x 900 mm (D) with stand height of 450 mm and internal wiring should be copper multistrained conductor including cooper Nuts& bolts, terminal Lugs comprising as follows:-
Dismantling of existing UNSV LT feeder pillar panel complete incl disconnection of wiring complete with necessary connection complete with taking out subject panel board incl UNSV UG cable and deposted to store yard of ARCH at Shokhuvi.
Earthing of machinery/equipment Installed at power house/substation, using 25 x 3 mm copper strip and copper plate of size 300 x 300 x 3 mm, as earth electrode.
Dismantling of existing distribution feeder incl re- Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above upto 400 sq. mm Cable.
Supply and fix double compression copper stain less steel gland for fixing armoured cable in panel of size cable of size 3 .5 core 400 SQMM size
but for cable of size 3.5 core 95 sq mm to 120 sqmm size
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit and all connected works 1.5 sq.mm. FR PVC insulated copper conductor singlecore cable etc as required and as directed at site. (92 Qtrsx3 Points (2x light pts and 1xfan Points)
Wiring for circuit/ submain wiring along with earth wire with the 1.5 Sqmmx 3 wires FR PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit as required (main DB to User DB)
S/F MCB DB 12 way SPN,240 Volts complete
S/F MCB SP 6 Amps,240 Volts AC complete
Supplying and fixing DP PVC Box enclosure on surface/ recess along with 6 amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing PVC batten/ angle holder including connection etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
CENTURY ENTERPRISES
SHUBHAM CENTRE
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .