| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-AOC | ₹12.2 L Quoted ₹13.0 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹13.5 L+₹53,160 (4.10%)Rejected-Finance | ₹13.5 L+₹53,160 (4.10%) | L2 | Rejected-Finance Not a lowest Tender |
| 3 | L3₹13.5 L+₹53,870 (4.16%)Rejected-Finance | ₹13.5 L+₹53,870 (4.16%) | L3 | Rejected-Finance Not a lowest Tender |
| 4 | L4₹13.8 L+₹88,110 (6.80%)Rejected-Finance | ₹13.8 L+₹88,110 (6.80%) | L4 | Rejected-Finance Not a lowest Tender |
| 5 | L5₹14.6 L+₹1.7 L (12.9%)Rejected-Finance | ₹14.6 L+₹1.7 L (12.9%) | L5 | Rejected-Finance Not a lowest Tender |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
30 Sept 2022, 6:00 pmClosed
GE AF Adm Area Gwalior
GE AF Adm Area Gwalior 474020
REPAIR/MAINT OF LT CABLE JOINT, SERVICE CONNECTION AND OTHER CONNECTED WORKS AT AF STN GWALIOR
2022_MES_551117_1
8235/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
AF Stn Gwalior
As per tender documents
7 documents required · 7 mandatory
₹500
GE AF Adm Area Gwalior
₹40,000
Yes
9 Jan 2023
10 Sept 2022
8 Oct 2022
10 Sept 2022
30 Sept 2022
24 Sept 2022
Amount
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as directed.
Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I
Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection all as specified and directed by Engineer-in-Charge.
Laying only old retrieved serviceable bricks for cable protection with axis of the bricks perpendicular to the axis of the cable of any description as obtained from dismantling of the cable complete all as specified and directed by the Engineer-in-Charge.
Disconnecting, taking out and removing old existing unserviceable underground, LT cable of any description and in any position complete including taking down protection pipe etc all as specified and directed for the following sizes:
(a) 10 Sqmm to 25 Sqmm any core
(b) 35 Sqmm to 70 Sqmm, 3½ core
(c) 95 Sqmm to 150 Sqmm, 3½ core
(d) 185 Sqmm to 300 sqmm, 3½ core
Laying, jointing and testing XLPE / P.V.C insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade of any description and any make laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge for the following sizes :-.
(a) 10 Sqmm to 25 Sqmm any core
(b) 35 Sqmm to 70 Sqmm, 3½ core
(c) 95 Sqmm to 150 Sqmm, 3½ core
(d) 185 Sqmm to 300 sqmm, 3½ core
(NOTE : (i) Old retrieved cables received in serviceable condition from taking down shall be used in the work. (ii) Additional quantity of LT cable, if any required, for replacing the defective portion of cable retrieved from dismantling /taking out, shall be measerd and paid under relevent item of sch.
Supply, laying, jointing and testing XLPE/ P.V.C insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade of any description and any make laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge for the following sizes :-Make:-HAVELLS/ Gloster/Polycab/CCI.
(a) 16 Sqmm, 4 core
(b) 25 Sqmm, 4 core
(c) 35 Sqmm, 3.5core
(d) 50 Sqmm, 3.5 core
(e) 70 Sqmm, 3.5 core
(f) 95 Sqmm, 3.5 core
(g) 120 Sqmm, 3.5 core
(h) 150 Sqmm 3.5 Core
(j) 185 Sqmm 3.5 Core
M&L in repair jointing & testing for provision of straight through joints, heat shrinkable, suitable for XLPE, LT Cable, 1100 Volts grade, for the following sizes of cables all as specified and directed by the Engineer-in-Charge. (MAKE : M.SEAL/DENSON/ MAHINDRA CHEMICALS/3M, REPL)
(a) 10 Sqmm to 16 Sqmm any core
(b) 25 Sqmm to 50 Sqmm, 3½ core
(c) 70 Sqmm to 120 Sqmm, 3½ core
(d) 150 Sqmm to 185 Sqmm, 3½ core
(e) 240 Sqmm to 300 Sqmm, 3½ core
M&L for Boring of hole under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia sutable for 0.4 mpa working pressure. all as specified and directed by Engineer-in-Charge. (NOTE : Pipes shall be laid minimum 1.00 mtr below/under existing road surfaces/taxi track / apron /floors etc)
Dismantling and Taking out old unserviceable GI pipe and Supplying, laying & jointing GI water tubing, 40 mm bore,light grade (ISI marked) as in sleeving etc laid in trenches / ducts / horizontal bore hole complete all as specified and directed by Engineer-in-Charge. (MAKE : TATA/JINDAL/TT SWASTIK)
Ditto as per item no. 12 above but GI tubing 50 mm bore.
Ditto as per item no. 12 above but GI tubing 80 mm bore.
Ditto as per item no. 12 above but GI tubing 100 mm bore.
Taking down existing LT cable from pole/ LT panel / board/feeder pillar box etc., cutting out over heated / burnt / unserviceable and portion of cable, preparation of cable end of required length retrieved from rings/loops incluiding necessary excavation and earth work all as required at site etc. and fixing and connecting the cable in position properly by providing suitable new aluminium lugs and suitable GI nuts, bolts & washers etc. all as directed by the Engineer-in-Charge for the following sizes of cable :-
(a) 10 Sqmm to 25 Sqmm cable of any core
(b) 35 Sqmm to 70 Sqmm cable of any core
(c) 95 Sqmm to 150 Sqmm cable of any core
(d) 185 Sqmm to 300 Sqmm cable of any core
S&F in repair new PVC insulated, served with inner seathed pvc tape weather proof stranded aluminium conductor cable twin core 6sqmm size for connecting from overhead conductor complete all as specified & directed.
Description of item as above but of size 10sqmm
Description of item as above but of size 16sqmm
Supply only PVC electrical insulation tape 25Rm complete all as specified and directed.
M&L for hard core broken stone/boulders of gauge n.exc. 63mm, deposited, spread and levelled in layers n.exc. 15cm thick, to a true surface at the places complete all as specified and directed.
Taking down old unserviceable and S&F flourocent board 8'x2' made out of 24gauge GI sheet and front with acrylic sheet total enclosed with computerized letter writtings of size not less than 100mm as directed by Engr-in-charge and inside with 4' long 2Nos of 18W LED tube light fittings complete with time control switch, MCB & battery backup with timer and board incl writing, with complete service connection of 2.50Sqmm 3core copper seathed cable 10mtr long incl protection pipe service connection from the pole by means of 40mm dia light grade pipe to the board incl excavation, returning filling and removing out surplus soil complete all as specified and directed. Make: Havells/CG/Bajaj
S&F MCCB 630Amp 4Pole, 36KA, 415V, 50Hz with thermal setting between 70 to 100% adjustable type and connecting up in the existing panel location incl taking out existing unserviceable MCCB complete all as specified and directed. Make: L&T/Havells/Schnieder
S&F MCCB 400Amp 4Pole, 36KA, 415V, 50Hz with thermal setting between 70 to 100% adjustable type and connecting up in the existing panel location incl taking out existing unserviceable MCCB complete all as specified and directed. Make: L&T/Havells/Schnieder
S&F MCCB 250Amp 4Pole, 36KA, 415V, 50Hz with thermal setting between 70 to 100% adjustable type and connecting up in the existing panel location incl taking out existing unserviceable MCCB complete all as specified and directed. Make: L&T/Havells/Schnieder
S&F MCCB 200Amp 4Pole, 36KA, 415V, 50Hz with thermal setting between 70 to 100% adjustable type and connecting up in the existing panel location incl taking out existing unserviceable MCCB complete all as specified and directed. Make: L&T/Havells/Schnieder
S&F MCCB 100Amp 4Pole, 36KA, 415V, 50Hz with thermal setting between 70 to 100% adjustable type and connecting up in the existing panel location incl taking out existing unserviceable MCCB complete all as specified and directed. Make: L&T/Havells/Schnieder
S&F on load change over switch, 4pole, with advance neutral 100Amp, 415V, 50Hz confirming to IS:13947 Part-3 connecting up in the existing panel location incl taking out existing unserviceable change over switch complete all as specified and directed. Make: L&T/Havells/Schnieder
lodhi builders
m/s A.A brothers
KPELECTRICAL AND AUTOMATION
M/S Amit Traders
m/s anil traders
M/s Mahesh Engineering Works
M/s KKPARASHAR
Om Electricals
M/s Yashika Enterprises
Lall Electronics
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .